Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2022_PS-2203001 thru PS-2203500_ - PS-2203097
PublicWorks
>
- PUBLIC SERVICES
>
PERMITS & DEVELOPMENT
>
Encroachment(EP)/Driveway(DW) Permits
>
2022
>
PS-2203001 thru PS-2203500
>
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2022_PS-2203001 thru PS-2203500_ - PS-2203097
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/24/2023 11:58:26 AM
Creation date
4/24/2023 11:54:32 AM
Metadata
Fields
Template:
Permits_Development
DocName
PS-2203097
Category07
Encroachment(EP)/Driveway(DW) Permits
Year2
2022
Notes2
Drake Ave., Hinkley Ave., Anteros Ave. and Main St. (See Attached DWGS for Exact Locations)
Address
1602 E. Lafayette St., Stockton,CA 95205
Application
California Water Service
Type
Trench;Bell Hole;Bore(up to 12 inch Dia)
Supplemental fields
Cross Ref
PWP730077
Type (2)
Encroachment Permit (EP)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
t6 <br />n <br />Right Lane Closure (TA-22b)mod <br />Pedestrian Control (TA-28/TA-29) <br />Utility Access & Repair <br />ROnD <br />E Main Street CLOKSED <br />EA <br />Job/P.O. # wz0-3 1}N� <br />F 1 � <br />— — -Drake Ave — <br />~_______EMainStreet <br />4— Design Speed 35WH <br />-- — — — — — — — — — — — — — — — — — <br />L=WS' <br />60 <br />L=WS <br />M4 -IOL <br />R11-4 <br />WORKING HOURS <br />8:30 AM to 3:30 PM <br />Use With TCP #EMS1, General Notes <br />And Legend, At All Times. <br />Maintain Access To All Residents, Businesses, Pedestrians <br />And Emergency Vehicles At All Times. <br />Horner Avenue a� <br />A <br />A14 -10R a <br />San Joaquin County Will Be Notified 48 Hours Prior to <br />Any Road Closure with Location, Date & Duration. All <br />Closure Will Be Reopened During Non Working Hours. <br />I t <br />1! <br />III 41t <br />1;1 <br />oETouR <br />; <br />Q <br />ROAD <br />Q <br />ROAD <br />WEAK <br />Q <br />14 <br />t <br />CLOSED <br />M4 -10R <br />WORK <br />�. <br />W20-1 <br />adi <br />R11-2 <br />G <br />w20-1 <br />Z <br />LANE <br />100 <br />FAS <br />/QG <br />t <br />ANE <br />ANE <br />iytC3DCLOSED <br />%W16-1� <br />CLOSED <br />ag 1 <br />c30 <br />Buffer Zone <br />C30 <br />Mer in a er 245' <br />J&0 <br />FF-------------� <br />H— <br />— — <br />— — — — — — — — — — — <br />-------------� <br />y <br />y <br />y <br />y <br />�1 Maintain 10+ 1 htP <br />Maintain 10+ Clear Lane <br />Clear Lane ° a 00 <br />m Q <br />n <br />tR. <br />p W20-1 = W20-1 <br />1 1yt <br />NOTICE: <br />Remove Or Reduce Control <br />Zone When Work Area No Longer <br />ffects That Area Of The Roadway <br />Shau/der Taper Eturrer Cone Spacing SI SI <br />10'-11'-12' Space Ta er Carl lWait Forl lWalt For <br />so' -ss' -so' 200' 30' s' Escort Escort <br />69'-75'-82' 250' 35' 17' <br />89'-98'-107' 305' 40' 20' F WORKAREA <br />I iu 1 2000' 1700'-770'-840'1 350'-385'-420-1 233'-257'-280' 730' 1 70' 1 35' <br />the, — rhe orad'Peed Limit se—pith (, f, t width of path If t,,v,l) b.M1,11 11,111 in, <br />START GATE= <br />West Valley Construction <br />DURATION= <br />2655 E. Miner Ave DWG= Lane Closure <br />Stockton, CA 95205 DATE= 412512022 <br />Tel:209-639-1107 Fax: 209-639-1107 <br />DRAW/NG NOT TO SCALE <br />Pedestrian monitor shall stop pedestrian(s) until <br />edestrian path has been re-established. maximum <br />length of delay shall not exceed two (2) minutes. <br />No pedestrians shall be directed into travel way <br />TRAFFIC CONTROL PLAN *_ <br />V1 <br />i;t <br />--OPTIONAL <br />'FLAG AS NEEDED OR <br />II <br />PREPARED <br />TO STOP <br />C9A W33 <br />-4 <br />NOTE: Use single or multiple flaggers <br />with C9A & 1413-4 signage spaced at <br />See ChartA) in all directions from won <br />area in addition to the plan to slow or <br />stop traffic. flaggers to be competent, <br />trained and qualified per CayOshd <br />regulations. Flaggers to maintain visua <br />and/or radio contact at all times. Signa <br />shall be placed in flashing RED mode. <br />EMS7 ITrench &Traffic <br />SUPPLY <br />SERVICE I SALES RENTAL <br />976 - 920 - 3304 <br />West Valley Construction <br />Citv Of Stockton <br />F ~ <br />------------------- <br />+.- <br />+— <br />y —i <br />------------------- <br />0 <br />R3-4 <br />Dost NO U-TURN signage <br />as needed, required or <br />directed when sufficient <br />turn radius can not <br />be maintained <br />I t <br />�7 ' <br />Q <br />t <br />0 ROAD <br />WORK <br />EA <br />1 W20 <br />T5 <br />11tj <br />00' <br />9 <br />Q ROAD <br />O HEA <br />W20-1 <br />1 <br />U <br />Legend <br />• +/- Cones <br />CH Arrowboard (Single) <br />i Sign Symbol <br />® Type 3 Barricade <br />® work Area <br />rte- /f1 <br />Manifest <br />59 x +/- Gems <br />10 x W20 1 Read WorkAhead <br />3 x C30 Lane Closed <br />3 x M410R Detour Right <br />2 x W203 Read Closed Ahead <br />1 x Arrowboard (Single) <br />1 x M4t0Loemur Left <br />1 x M410RDET0UR-RICHT <br />1 x R11-2 Road Closed <br />1 x R11-0 Road Closed to Thor Tragic <br />Ix R31 No Right Tum <br />1 x W11/1&1 Share The Road <br />1 x W20 2 oetourAhead <br />W205L <br />ENGINEERS DISCLAIMER: THIS PLAN IS A DRAFT FOR IMPLEMENTATION AT THE DIRECTION OF OTHERS. IT WAS PREPARED IN CONFORMANCE WITH TRAFFIC CONTROL STANDARDS ESTABLISHED BY MUTCD & LOCAL AUTHORITIES. <br />FEILD ADJUSTMENTS MAY BE REQUIRED BY LOCALIZED AND/OR TEMPORARY TRAFFIC CONDITIONS. PREPARER ASSUMES NO LIABILITY FOR ANYACCIDENT INJURY OR DEATH OCCURING FROM THE USE OF THIS PLAN UNLESS SITE SPECIFIC SERVICES ARE PROVIDED. <br />