Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2023_PS-2300501 thru PS-2301000_ - PS-2300788
PublicWorks
>
- PUBLIC SERVICES
>
PERMITS & DEVELOPMENT
>
Encroachment(EP)/Driveway(DW) Permits
>
2023
>
PS-2300501 thru PS-2301000
>
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2023_PS-2300501 thru PS-2301000_ - PS-2300788
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/26/2023 9:18:49 AM
Creation date
4/26/2023 9:16:13 AM
Metadata
Fields
Template:
Permits_Development
DocName
PS-2300788
Category07
Encroachment(EP)/Driveway(DW) Permits
Year2
2023
Notes2
S/S of Tehama Dr. 320' S/O Kristen Ct.
Address
4125 Northgate Blvd.,Sacramento,CA 95834
Application
Tak Communications Ca Inc.
Type
Bore (up to 12 inch Dia); Bore Pits
Supplemental fields
Cross Ref
PWP7110005
Type (2)
Encroachment Permit (EP)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
GENERAL NOTES <br />• ALL GENERAL NOTES SHALL APPLY TO ALL DRAWINGS, PLANS AND DETAILS. <br />• CONTRACTOR SHALL NOTIFY UNDERGROUND SERVICE ALERT (USA), AT LEAST 48 <br />HOURS (AND NOT MORE THAN 14 DAYS) PRIOR TO THE START OF CONSTRUCTION <br />BY CALLING (800) 227-2600. <br />• CONTRACTOR SHALL POTHOLE/HAND DIG AND VERIFY ALL UNDERGROUND <br />UTILITIES PRIOR TO THE START OF CONSTRUCTION. ALL UTILITY LOCATIONS ON <br />PLANS ARE APPROXIMATE, CONTRACTOR MUST VERIFY. <br />• CONTRACTOR SHALL VERIFY ALL FOOTAGES ON SITE, PRIOR TO THE START OF <br />CONSTRUCTION. ALL DIMENSIONS SHOWN ON PLANS ARE APPROXIMATE. <br />• CONTRACTOR SHALL KEEP ACOPY OF APPROVED PLAN(S)AND PERMIT(S) AT THE <br />JOB SITE AT ALL TIMES AND PRESENT IT TO AN AUTHORIZED AGENT OF THE <br />CITY/COUNTYAND/OR LAW ENFORCEMENT UPON REQUEST. <br />• CONTRACTOR SHALL ENSURE THAT ANY EXISTING FACILITIES DAMAGED OR <br />REMOVED SHALL BE REPLACED IN KIND OR BETTER, INCLUDING BUT NOT LIMITED <br />TO REPLACING EXISTING STRIPING AND REMOVING UNNECESSARY "USA' <br />MARKINGS. <br />• CONTRACTOR SHALL WORK ONLY DURING APPROVED HOURS, UNLESS OTHERWISE <br />APPROVED IN WRITING BY THE "CITY/COUNTY ENGINEER." <br />• CONTRACTOR SHALL PERFORM ALL WORKAND TRAFFIC CONTROL IN ACCORDANCE <br />WITH THE CITY/COUNTYAND STATE OF CALIFORNIA STANDARD PLANS AND <br />SPECIFICATIONS, AND CURRENT CALIFORNIA DEPARTMENT OF TRANSPORTATION <br />"MANUAL OF TRAFFIC CONTROLS AND MAINTENANCE OF HAZARD ZONE" AND <br />"MANUAL OF WARNING SIGNS, LIGHTS AND DEVICES" FOR USE IN PERFORMANCE OF <br />WORK UPON HIGHWAYS. FLASHING ARROW SIGNS SHALL BE REQUIRED FOR ALL <br />LANE CLOSURES. <br />• CONTRACTOR SHALL ENSURE ALL WORK PERFORMED IS IN ACCORDANCE WITH <br />REGULATIONS AND STANDARDS SET BY ANY AND ALL REGULATORY AGENCIES <br />HAVING JURISDICTION AT THIS WORK SITE, INCLUDING BUT NOT LIMITED TO THE <br />STATE OF CALIFORNIA PUBLIC UTILITY COMMISSION (CPUC), THE STATE OF <br />CALIFORNIA OCCUPATIONAL SAFETYAND HEALTH ACT (CAL OSHA), THE COUNTY <br />AND THE CITY. <br />• ALL WORK SHALL BE ACCESSIBLE AND SUBJECT TO INSPECTION BY THE <br />CITY/COUNTY ENGINEER AND/GRAN AUTHORIZED AGENT OF COMCAST. <br />• CONTRACTOR SHALL NOTIFY BUSINESS ESTABLISHMENTS/OWNERS AFFECTED BY <br />THE WORKAT LEAST 72 HOURS IN ADVANCE OF CONSTRUCTION. <br />• CONTRACTOR SHALL NOTIFY THE PUBLIC WORKS INSPECTOR 48 HOURS IN <br />ADVANCE OF WORK COMMENCING. <br />THIS IS A COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIAL <br />REV DESCRIPTION DATE <br />DESIGN: CITYRISE <br />DRAWN BY: <br />APPROVED: <br />APPROVED: <br />APPROVED: <br />SYMBOLS <br />o EXISTING IRRIGATION VAULT <br />D <br />NEW COMCAST POWER SUPPLY <br />® <br />NEW COMCAST LOW PROFILE <br />m B <br />POWER SUPPLYW/METER <br />Q <br />NEW COMCASTVAULT <br />m <br />NEW COMCAST PEDESTAL <br />® <br />BORE PIT <br />FOC <br />POTHOLE <br />SO <br />NEW RISERATTACHED TO POLE <br />® <br />EXISTING POLE <br />Isi <br />EXISTING COMCAST VAULT <br />® <br />EXISTING COMCAST PEDESTAL <br />o EXISTING IRRIGATION VAULT <br />D <br />EXISTING UTILITY VAULT/PEDESTAL <br />pQ <br />GAS/WATER VALVE <br />C/L <br />TREE/BUSHES <br />J <br />IMPORTANT NOTICE <br />Section # 4216/4217 of the Government Code requires a <br />Dig Alert Identification Number to be issued before a <br />'Permit to Excavate' will be valid For your Dig Alert I.D. <br />CALL TOLL FREE <br />48 HOURS BEFORE YOU DIG <br />UNDERGROUND SERVICE ALERT <br />1-800-227-2600 <br />TRANSFORMER <br />STREET LIGHT <br />TRAFFIC SIGNAL COMBINATION <br />FIRE HYDRANT <br />MONUMENT <br />CATCH BASIN <br />STORM DRAIN MANHOLE <br />WATER MANHOLE <br />SANITARY SEWER MANHOLE <br />SEWER CLEAN OUT <br />ELECTRIC MANHOLE <br />UNIDENTIFIED MANHOLE <br />WATER METER <br />GAS METER <br />549685 <br />LINETYPES <br />CL <br />PROPOSED TRENCH/BORE ROUTE <br />PROPOSED OVERLASH ROUTE <br />PROPOSED OVERPULL ROUTE <br />EXISTING COMCAST ROUTE <br />EXISTING TELEPHONE SYSTEM <br />EXISTING TV SYSTEM <br />EXISTING GAS SYSTEM <br />EXISTING ELECTRICAL SYSTEM <br />EXISTING JOINT TRENCH <br />EXISTING IRRIGATION SYSTEM <br />EXISTING SANITARY SEWER <br />EXISTING STORM DRAIN <br />EXISTING WATER LINE <br />EXISTING FENCELINE <br />ROADWAY CENTER LINE <br />PROPERTY LINE <br />RIGHT OF WAY LINE <br />/_1:1:10 AV I_1% I [SIM <br />COMCAST <br />COMCAST <br />PL <br />PROPERTY LINE <br />C/L <br />CENTER LINE <br />PUE <br />PUBLIC UTILITY EASEMENT <br />(E) <br />EXISTING <br />R/W <br />RIGHT OF WAY <br />FOC <br />FACE OF CURB <br />SO <br />EXISTING STORM DRAIN <br />MIN <br />MINIMUM <br />SS <br />EXISTING SANITARY SEWER <br />MAX <br />MAXIMUM <br />T <br />EXISTING TELEPHONE <br />DWY <br />DRIVEWAY <br />W <br />EXISTING WATER <br />(N) <br />NEW <br />E <br />EXISTING ELECTRIC <br />(T) <br />TEMPORARY <br />G <br />EXISTING GAS <br />CNDT <br />CONDUIT <br />EDP <br />EDGE OF PAVEMENT <br />BOW <br />BACK OF WALK <br />LOG <br />LIP OF GUTTER <br />LEGEND, GENERAL NOTES <br />13625 HARTLEY LN <br />CONSTRUCTION TYPE: BORE, PLACE NEW VAULT. <br />SYSTEM: SAN JOAQLIN COUNTY <br />NODE: <br />SHEET: CD -0 <br />