My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2022_PS-2203001 thru PS-2203500_ - PS-2203134
PublicWorks
>
- PUBLIC SERVICES
>
PERMITS & DEVELOPMENT
>
Encroachment(EP)/Driveway(DW) Permits
>
2022
>
PS-2203001 thru PS-2203500
>
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2022_PS-2203001 thru PS-2203500_ - PS-2203134
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/27/2023 9:13:56 AM
Creation date
4/27/2023 9:11:37 AM
Metadata
Fields
Template:
Permits_Development
DocName
PS-2203134
Category07
Encroachment(EP)/Driveway(DW) Permits
Year2
2022
Notes2
W/S of Gettysburg Pl. 113' N/O Douglas Rd.
Address
12687 S. Manthey Rd., Lathrop,CA 95330
Application
SEFNCO
Type
Aerial Work
Supplemental fields
Cross Ref
PWP7110005
Type (2)
Encroachment Permit (EP)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
—TABLE 6C-2 2014 CALIFORNIA MUTCD- <br />-STOPPING SIGHT DISTANCE AS A FUNCTION OF SPEED— <br />SPEED' <br />(MPH) <br />DISTANCE <br />(FT) <br />20 <br />115 <br />25 <br />155 <br />30 <br />200 <br />35 <br />250 <br />40 <br />305 <br />45 <br />360 <br />50 <br />425 <br />55 <br />495 <br />60 <br />570 <br />65 <br />645 <br />70 <br />730 <br />75 <br />820 <br />* Posted speed limit, off—peak 85th—percentile speed <br />prior to work starting, or other anticipated <br />operating speed <br />—TABLE 6C-1 2014 CALIFORNIA MUTCD- <br />-RECOMMENDED ADVANCE WARNING SIGN SPACING— <br />ROAD TYPE <br />SPEED <br />(S) <br />MPH <br />DISTANCE <br />A <br />BETWEEN <br />B <br />SIGNS <br />** <br />C <br />ORBAN— 25 MPH OR LESS ... <br />10D <br />FEET <br />100 <br />1DD FEET <br />100 <br />FEET <br />URBAN— MORE THAN 25 MPH TO 40 MPH *** <br />250 <br />FEET <br />250 <br />250 FEET <br />250 <br />FEET <br />URBAN— MORE 4D MPH rrr <br />350 <br />FEET <br />250 <br />350 FEET <br />35D <br />FEET <br />RURAL <br />5DD <br />FEET <br />250 <br />5DD FEET <br />5DD <br />FEET <br />EXPRESSWAY/FREEWAY <br />1000 <br />FEET <br />1500 FEET <br />264D <br />FEET <br />** The column heading a, b, and c are the dimensions shown in figures 6H-1 <br />through 6H-46. The A Dimension is the distance from the transition or point of <br />restriction to the first sign. The B dimension is the distance between the first <br />and second signs. The C dimension is the distance between the second and third <br />sign. (The •'flsrt sign" is the sign in a three—sign series that is closest to ttc <br />zone. The 'third sign" Is the sign that is furthest upstream from the ttc zone.) <br />*** Posted speed limit, off—peak 85th—percentile speed prior to war starting, or <br />other anticipated operating speed in mph <br />MINIMUM RECOMMENDED CHANNELING DEVICE AND SIGN SPACING <br />SPEED <br />(S) <br />MPH <br />DIMENSION A <br />SIGN <br />SPACING <br />FT <br />DIMENSION B DIMENSION C <br />MERGING SHIFTING <br />TAPER TAPER <br />(L) (L/2) <br />FT FT <br />DIMENSION D <br />SHOULDER <br />TAPER <br />(L/3) <br />FT <br />DIMENSION E <br />BUFFER <br />SPACE <br />FT <br />MAXIMUM <br />CHANNELIZER <br />SPACING IN <br />TAPER <br />FT <br />MAXIMUM <br />CHANNELIZER <br />SPACING IN <br />TANGENT <br />FT <br />25 <br />100 <br />125 65 <br />30 On (100ft) per lane <br />158 <br />25 <br />50 <br />30 <br />250 <br />180 90 <br />60 <br />205 <br />30 <br />60 <br />35 <br />250 <br />245 125 <br />82 <br />257 <br />35 <br />70 <br />40 <br />250 <br />320 160 <br />107 <br />315 <br />40 <br />80 <br />45 <br />350 <br />540 270 <br />180 <br />378 <br />45 <br />90 <br />50 <br />350 <br />600 300 <br />200 <br />446 <br />50 <br />100 <br />55 <br />500 <br />660 330 <br />220 <br />520 <br />50 <br />100 <br />60 <br />500 <br />720 360 <br />240 <br />598 <br />50 <br />100 <br />65 <br />500 <br />780 390 <br />260 <br />682 <br />50 <br />100 <br />70 <br />500 <br />840 420 <br />280 <br />771 <br />50 <br />100 <br />*TAPER LENGTHS LISTED ARE VALID FOR 12' OFFSET OR LESS <br />THIS IS A COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIAL <br />DESIGN: REV DESCRIPTION DATE <br />1 SEFNCO 9/26/22 <br />DRAWN BY: <br />GENERAL TRAFFIC CONTROL NOTES <br />TRAFFIC CONTROL PLAN SHALL CONFORM TO THE MOST CURRENT CALIFORNIA MANUAL ON <br />UNIFORM TRAFFIC CONTROL DEVICES (CAMUTCD) AND STATE STANDARD PLANS <br />NO LANE CLOSURES PERMITTED BEFORE 9:OOA AND AFTER 3:OOP. <br />ALL AFFECTED RESIDENTS, BUSINESSES, AGENCIES, AND SCHOOLS SHALL BE GIVEN A 72 <br />HOURS NOTICE PRIOR TO THE START OF WORK AND THEIR ACCESS SHALL BE MAINTAINED AT <br />ALL TIMES. <br />TEMPORARY NO PARKING SIGNS SHALL BE POSTED 48 HOURS PRIOR TO START OF WORK. <br />ALL CONFLICTING SIGNS, STRIPING OR PAVEMENT MARKINGS SHALL BE COVERED OR REMOVED <br />AND REPLACED WHEN WORK IS COMPLETED, <br />TRAFFIC DIRECTION THROUGH A SIGNALIZED INTERSECTION SHALL BE CONDUCTED BY A CITY <br />OF MODESTO UNIFORMED POLICE OFFICER OR A COMMUNITY SERVICE OFFICER ONLY. SHOULD <br />WORK REQUIRE A SIGNAL TO BE OVERRIDDEN, ARRANGEMENT SHALL BE MADE WITH THE CITY <br />POLICE DEPT AND TRANSPORTATION ENGINEERING DEPT AT LEAST 14 DAYS PRIOR TO START <br />OF WORK. <br />—TABLE 6C-3 2014 CALIFORNIA MUTCD- <br />-TAPER LENGTH CRITERIA FOR TEMPORARY TRAFFIC CONTROL ZONE— <br />TYPE OF TAPER <br />2 <br />APPROVED: <br />3 <br />APPROVED: <br />4 <br />APPROVED: <br />5 <br />GENERAL TRAFFIC CONTROL NOTES <br />TRAFFIC CONTROL PLAN SHALL CONFORM TO THE MOST CURRENT CALIFORNIA MANUAL ON <br />UNIFORM TRAFFIC CONTROL DEVICES (CAMUTCD) AND STATE STANDARD PLANS <br />NO LANE CLOSURES PERMITTED BEFORE 9:OOA AND AFTER 3:OOP. <br />ALL AFFECTED RESIDENTS, BUSINESSES, AGENCIES, AND SCHOOLS SHALL BE GIVEN A 72 <br />HOURS NOTICE PRIOR TO THE START OF WORK AND THEIR ACCESS SHALL BE MAINTAINED AT <br />ALL TIMES. <br />TEMPORARY NO PARKING SIGNS SHALL BE POSTED 48 HOURS PRIOR TO START OF WORK. <br />ALL CONFLICTING SIGNS, STRIPING OR PAVEMENT MARKINGS SHALL BE COVERED OR REMOVED <br />AND REPLACED WHEN WORK IS COMPLETED, <br />TRAFFIC DIRECTION THROUGH A SIGNALIZED INTERSECTION SHALL BE CONDUCTED BY A CITY <br />OF MODESTO UNIFORMED POLICE OFFICER OR A COMMUNITY SERVICE OFFICER ONLY. SHOULD <br />WORK REQUIRE A SIGNAL TO BE OVERRIDDEN, ARRANGEMENT SHALL BE MADE WITH THE CITY <br />POLICE DEPT AND TRANSPORTATION ENGINEERING DEPT AT LEAST 14 DAYS PRIOR TO START <br />OF WORK. <br />—TABLE 6C-3 2014 CALIFORNIA MUTCD- <br />-TAPER LENGTH CRITERIA FOR TEMPORARY TRAFFIC CONTROL ZONE— <br />TYPE OF TAPER <br />TAPER LENGTH (L)* <br />Merging Taper <br />at least L <br />Shifting Taper <br />at least 0.5 L <br />Shoulder Taper <br />at least 0.33 L <br />One lane, Two—way traffic taper <br />30 PH 100ft Maximum <br />Downstream Taper <br />30 On (100ft) per lane <br />—TABLE 6C-1 2014 CALIFORNIA MUTCD- <br />-FORMULAS FOR DETERMINING TAPER FENGTH— <br />Where: L= taper length in feet <br />W= width of offset in feet <br />S= posted speed limit, or off—peak 85th—percentile <br />speed prior to work starting, or the anticipated operating <br />speed in km/h (mph) <br />IMPORTANT NOTICE <br />Section # 4216/4217 of the Government Code requires a <br />Dig Alert Identification Number to be Issued before a <br />"Permit to Excavate" will be valid For your Dig Alert I.D. <br />CALL TOLL FREE <br />48 HOURS BEFORE YOU DIG <br />UNDERGROUND SERVICE ALERT <br />1-800-227-2600 <br />LEGEND <br />PORTABLE FLASHING BEACON (P.F.B.) <br />H TYPE III BARRICADE W/SIGN <br />>=( TYPE II BARRICADE W/SIGN <br />• CHANNELIZING DEVICE <br />Z TRAFFIC CONE WITH CLIP ON SIGN <br />Z TYPE I W/SIGN <br />EXISTING SIGN <br />OSIGNALIZED INTERSECTION <br />*� FLASHING ARROW BOARD <br />HIGH LEVEL WARNING DEVICE (FLAGTREE) <br />FLAGGER <br />TARSAL TOW AWAY NO STOPPING ANY TIME <br />® EXISTING DRIVEWAY <br />WORK ZONE (ACTIVITY AREA) LIMITS <br />y DIRECTION OF TRAFFIC (NOT PAVEMENT MARKING) <br />TCP General Notes end Tables <br />�+++'• <br />Call <br />PROJ#: 1176188 <br />SPEED LIMIT (S) <br />TAPER LENGTH (L) <br />FEET <br />40 mph or less <br />L=WS'/60 <br />0 mph or more <br />L=W6 <br />Where: L= taper length in feet <br />W= width of offset in feet <br />S= posted speed limit, or off—peak 85th—percentile <br />speed prior to work starting, or the anticipated operating <br />speed in km/h (mph) <br />IMPORTANT NOTICE <br />Section # 4216/4217 of the Government Code requires a <br />Dig Alert Identification Number to be Issued before a <br />"Permit to Excavate" will be valid For your Dig Alert I.D. <br />CALL TOLL FREE <br />48 HOURS BEFORE YOU DIG <br />UNDERGROUND SERVICE ALERT <br />1-800-227-2600 <br />LEGEND <br />PORTABLE FLASHING BEACON (P.F.B.) <br />H TYPE III BARRICADE W/SIGN <br />>=( TYPE II BARRICADE W/SIGN <br />• CHANNELIZING DEVICE <br />Z TRAFFIC CONE WITH CLIP ON SIGN <br />Z TYPE I W/SIGN <br />EXISTING SIGN <br />OSIGNALIZED INTERSECTION <br />*� FLASHING ARROW BOARD <br />HIGH LEVEL WARNING DEVICE (FLAGTREE) <br />FLAGGER <br />TARSAL TOW AWAY NO STOPPING ANY TIME <br />® EXISTING DRIVEWAY <br />WORK ZONE (ACTIVITY AREA) LIMITS <br />y DIRECTION OF TRAFFIC (NOT PAVEMENT MARKING) <br />TCP General Notes end Tables <br />�+++'• <br />Call <br />PROJ#: 1176188 <br />CONSTRUCTION TYPE: SPLICE <br />SYSTEM: <br />SHEET: 4 OF 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.