My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2021_PS-2102001 thru PS-2102500_ - PS-2102021
PublicWorks
>
- PUBLIC SERVICES
>
PERMITS & DEVELOPMENT
>
Encroachment(EP)/Driveway(DW) Permits
>
2021
>
PS-2102001 thru PS-2102500
>
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2021_PS-2102001 thru PS-2102500_ - PS-2102021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/1/2023 10:21:38 AM
Creation date
5/1/2023 10:10:33 AM
Metadata
Fields
Template:
Permits_Development
DocName
PS-2102021
Category07
Encroachment(EP)/Driveway(DW) Permits
Year2
2021
Notes2
Manthey Road S/O Yettner Road, Stockton
Address
1325 J Street, Sacramento,CA 95814
Application
US Army Corps of Engineers
Type
Road Widening,Driveways & Turn Lanes
Supplemental fields
Cross Ref
PWP760036
Type (2)
Encroachment Permit (EP)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
F <br />0 <br />g <br />d <br />c <br />n <br />o <br />v <br />E E <br />w <br />W <br />r <br />d co <br />c <br />r <br />v <br />c <br />W <br />d <br />e <br />0 <br />N <br />N <br />g <br />C <br />v <br />v <br />B <br />g <br />0 <br />m <br />0 <br />1 2 3 4 5 6 7 8 9 10 <br />0 SOLICITATION SET 15 OCT 21 <br />NO REVISIONS DATE <br />J <br />1104*4 <br />BUBBLER HEAD <br />BESIDE - l\ <br />INSTALLED BESIDE <br />ROOTBALL \ <br />PVC ELL (SxT) <br />LATERAL LINE <br />ISOMETRIC VIEW <br />v <br />PEA GRAVEL, 2 <br />CU FT MIN <br />NOTES: 2" MAX <br />1. USE TEFLON TAPE ON ALL <br />THREADED FITTINGS <br />2. DRAIN PIPE SHALL BE <br />INSTALLED 2" MAX BESIDE ^o <br />ROOTBALL OF ALL TREES cli °qo° <br />3. REFER TO LEGEND FOR ° <br />QUANTITY OF BUBBLERS <br />PER TREE; EXACT <br />PLACEMENT OF SECTION VIEW <br />BUBBLERS IN FIELD <br />TREE BUBBLER ASSEMBLY <br />PLASTIC GRATE, IF NO <br />TREE GRATE <br />ROOTBALL <br />I-SCH 40 PVC TEE OR ELBOW <br />FINISH GRADE <br />ROOTBALL <br />ADJACENT HARDSCAPE, <br />SEE PLANS <br />BUBBLER HEAD, TYP <br />4" PERF DRAIN PIPE, <br />MIN 10" LONG <br />LATERAL LINE <br />PVC TEE OR ELL, TYP <br />TREES SUPPLIED WITH TOPS TOO LARGE <br />FOR TRUNKS TO SUPPORT SHALL BE <br />PRUNED AS DIRECTED BY OWNER'S <br />REPRESENTATIVE TO REDUCE CROWN <br />WEIGHT. DO NOT REMOVE LATERALS <br />ALONG TRUNK <br />STAPLE TREE TIE WIRE TO POST TO <br />PREVENT TIE FROM SLIPPING <br />SEE SPECS FOR TIE -TYPE; SHALL BE <br />INSTALLED EQUAL ON BOTH POSTS AT <br />PROPER HEIGHT, DEFINED AS WHERE THE <br />TREE WILL RESUME UPRIGHT STANCE IF <br />PULLED TO ONE SIDE <br />SEE SPECS FOR STAKE TYPE; SET 30" INTO — <br />GRADE OR UNDISTURBED SUBGRADE A <br />MINIMUM OF 12" BELOW ROOTBALL; PLACE <br />STAKES PERPENDICULAR TO PREVAILING WIND <br />CROWN OF ROOTBALL SET V-2" ABOVE <br />FINISH GRADE; DO NOT PENETRATE <br />ROOTBALL WITH STAKING; ROOT FLARE <br />SHALL BE ABOVE GRADE AND VISIBLE <br />NATIVE SOIL <br />3" HIGH WATERING BASIN —III—I <br />WITH MULCH; SEE SPECS III -1-1 II (— <br />PREPARED PLANTING MIX BACKFILL, J <br />SEE SPECS Iiia <br />LIGHTLY TAMPED NATIVE SOIL SUPPORT <br />TO PREVENT SETTLING <br />3x SIZE OF ROOTBALL IN COMPACTED SOILS <br />MIN 2x SIZE OF ROOTBALL OTHERWISE <br />NOTE: <br />1. MULTI -TRUNKED TREES OR THOSE SUPPLIED WITH WELL -TAPERED, STRONG TRUNKS <br />WHICH WILL STAND ALONE, MAY BE INSTALLED WITH MINIMUM STAKING & TIES <br />2. FOR BALL-AND-BURLAPPED TREES: REMOVE ALL TWINE, ROPE, AND WIRE FROM <br />ROOTBALL, REMOVE BURLAP FROM TOP HALF OF ROOTBALL, PLACE TREE IN POSITION <br />3. FOR BOX TREES: KNOCK BOARDS FREE FROM BOTTOM OF BOX, PLACE TREE IN <br />POSITION, REMOVE METAL STRAPS; GENTLY KNOCK REMAINING BOX SIDES AWAY <br />FROM ROOTBALL <br />4. TREES WITH BOUND OR ENCIRCLING ROOTS WILL BE REJECTED <br />5. REMOVE ALL STRAPS, WIRE, AND SIMILAR DEBRIS FROM TREE WELL PRIOR TO <br />BACKFILLING <br />6. SEE ROOT BARRIER DETAIL <br />TREE PLANTING <br />ADJACENT <br />PAVING, SEE <br />PLAN <br />FINISH GRADE <br />PVC SCH 40 ELBOW <br />PVC SCH 80 NIPPLE <br />IN FINAL POSITION; <br />RISER SHALL BE AT <br />A 450 ANGLE <br />PVC TEE— <br />(SxSxT) OR <br />ELBOW (Si <br />SPRINKLER NOZZLE <br />POP-UP BODY ASSEMBLY; <br />INSTALL z" ABOVE FINISH <br />GRADE AT TURF, 4" ABOVE <br />FINISH GRADE AT SHRUBS & <br />GROUNDCOVER <br />PVC SCH 80 NIPPLE, SIZE <br />AS REQUIRED <br />PVC SCH 40 STREET ELL <br />:RAL LINE (SEE PLANS) <br />SCH 40 STREET ELL <br />NOTES: <br />1. USE TEFLON TAPE ON ALL THREADED FITINGS - 121" WRAPS MAX <br />2. IRRIGATION HEADS TO BE 6" FROM PAVING FOR TURF AREAS <br />POP-UP SPRAY HEAD <br />ar, <br />`+ <br />x <br />O <br />W <br />2 <br />of <br />W <br />a <br />o <br />It <br />a <br />Of <br />O <br />LL <br />❑ <br />W <br />W <br />W <br />z <br />a <br />ro <br />(V <br />N <br />NOTES: <br />1. INSTALL PER MANUFACTURER SPECIFICATIONS <br />2. INSTALL AT EACH TREE LOCATION IMMEDIATELY <br />ADJACENT TO HARDSCAPE <br />3. IDENTIFY BARRIER LOCATIONS FOR APPROVAL PRIOR <br />TO INSTALLATION <br />TOP OF ROOT BARRIER <br />MUST BE AT LEAST 1" <br />ABOVE GRADE <br />SIDEWALK OR CURB, <br />SEE HARDSCAPE PLANS \ <br />ROOT BARRIER, SEE SPECS <br />SOIL BACKFILL <br />ROOT BA R R I E R <br />NTS <br />SET TOP OF POTTING <br />SOIL 1-2" ABOVE <br />FINISHED GRADE <br />FINISH te <br />GRADE <br />III III BACKFILL WITH PREPARED <br />—III - —III=III <br />TOPSOIL/AMENDED NATIVE <br />MULCH, �; III :;': ,' SOIL <br />SEE �= = — ROOTBALL;LOOSEN <br />SPECS = GENTLY, CUT MATTED OR <br />ENCIRCLING ROOTS <br />III=III III III- , <br />NATIVE OR COMPACTED SOIL <br />2X WIDTH OF SCARIFY BOTTOM & SIDES OF <br />ROOTBALL HOLE PRIOR TO PLANTING <br />NOTES: <br />1. FOR BALL-AND-BURLAPPED SHRUB: REMOVE BINDINGS, FOLD BURLAP DOWN <br />FROM TOP 1/3 OF ROOTBALL, SPREAD ROOTS EVENLY PRIOR TO PLACEMENT <br />2. FOR CONTAINER -GROWN SHRUB: REMOVE CONTAINER FROM ROOTBALL AND <br />GENTLY LOOSEN AND SPREAD ROOTS EVENLY PRIOR TO PLACEMENT <br />SHRUB PLANTING <br />NTS <br />PLANT ONE HALF OF <br />SPECIFIED SPACING WHEN <br />ADJACENT TO EDGE <br />PAVING OR LAWN EDGE, TYP <br />NOTES: <br />1. ALL GROUNDCOVER SHALL BE PLANTED (a) EQ TRIANGULAR SPACING OR OC SPACING AS SPECIFIED ON THE <br />PLANTING PLAN <br />2. LOCATE GROUNDCOVER ONE HALF OF SPECIFIED SPACING DISTANCE FROM ANY CURB, SIDEWALK, OR OTHER <br />HARD SURFACE, UNLESS OTHERWISE SPECIFIED <br />GROUNDCOVER PLANTING <br />NTS <br />Number <br />CONSULTANTS: CONSULTANT: ARCH ITECTSIENGINEERS: <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />10 <br />F <br />E <br />D <br />C <br />B <br />A <br />Drawing <br />Project Title <br />Station Number <br />Office of <br />VA Livermore Realignment and <br />sao <br />640.23 <br />640.423 <br />ARCHITECTURE( MECHANICALIELECTRICAU CMLISURVEYOR: FIRE PROTECTION: <br />PLUMBING: <br />NOSCApf <br />Qq_\ �- C07* <br />PLANTING AND IRRIGATION DETAILS <br />Closure - Manthey Rd. Offsite and <br />Construction <br />Building Number <br />S CRIORD SIGN/ I <br />COMMUNICATIONS/ MEDICAL GaynerEngineels Sarldis Jensen Hughes Inc. <br />EQUIPMENT/ MASTER PLAN 1133 Post Street 8369thShet 2950BusNrkAvenue, Ste. 225 <br />�� c <br />ti <br />`= N 5 ti � <br />Onsite Revisions <br />and Facilities <br />Location Stockton (French Camp) <br />San Joaquin County, CA <br />Drawl number <br />"� <br />LANDSCAPE San Franclsco,CA 94109 OaNand, CA 94607 Walnut Creek CA 94597 <br />ENVIRONMENTAL <br />ASSESSMENT: STRUCTURAL: GEOTECHNICAL: COST ESTIMATING: <br />signature — <br />z-za-z3 <br />N Renewal 0/15/2021e * <br />Date <br />rgT�OF <br />Management <br />HDR Architechae,Inc. 37755 Bealenkoe Street Suite 500 432Engineers 2111aSWCorbett#200 300 California5treet,Suite400 <br />201 California Street, Suite 1500 San Francisco, CA 94105 Portland, OR 97239 San Francisco, CA 94104 <br />CAL\FO��\p <br />Date Checked by Drawn <br />LD100 <br />U.S. Department <br />`//�*of <br />San Franasco, CA 94111 <br />7 5 OCT 2021 AC AYS <br />v„ Veterans Affairs <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />10 <br />F <br />E <br />D <br />C <br />B <br />A <br />
The URL can be used to link to this page
Your browser does not support the video tag.