| 1. CONTRACTOR SHALL BECOME FAMILIAR WITH PROJECT SURROUNDINGS, WORKING CONDITIONS, 
<br />AND SITE LIMITATIONS AND WILL INCLUDE ALLOWANCES IN THEIR BID TO COVER ANY PROJECT 
<br />CONSTRAINTS. 
<br />2. CONTRACTOR SHALL BE RESPONSIBLE FOR ADHERING TO AND COMPLYING WITH LOCAL 
<br />GOVERNING AGENCY PERMIT RESTRICTIONS, WHICH MAY AFFECT ALLOWABLE WORKING HOURS AND 
<br />NOISE LEVELS. 
<br />3. CONTRACTOR SHALL PROVIDE TRAFFIC CONTROL AS REQUIRED BY APPLICABLE LOCAL GOVERNING 
<br />AGENCY AND SHALL SUBMIT A TRAFFIC CONTROL PLAN PER CALTRANS STANDARDS TO 
<br />GOVERNING AGENCY (AS REQUIRED) PRIOR TO CONSTRUCTION. 
<br />4. CONTRACTOR SHALL APPLY CALIFORNIA STORMWATER QUALITY ASSOCIATION (CASQA) BEST 
<br />MANAGEMENT PRACTICES TO PREVENT WATER AND SEDIMENT FROM ENTERING NAVIGABLE 
<br />WATERWAYS. THE CONTRACTOR IS RESPONSIBLE FOR IDENTIFYING AND INSTALLING THE 
<br />APPLICABLE AND APPROPRIATE BMPs IDENTIFIED IN THE CASQA - STORMWATER BEST 
<br />MANAGEMENT PRACTICES HANDBOOK AVAILABLE ONLINE AT WWW.CABMPHANDBOOKS.COM. SOME 
<br />OF THE REQUIRED PRACTICES MAY OR MAY NOT BE SHOWN ON THIS SITE PLAN. 
<br />5. CONTRACTOR TO CONTACT "UNDERGROUND SERVICE ALERT" 48 HOURS PRIOR TO ANY 
<br />EXCAVATION. 
<br />6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXACT LOCATION AND 
<br />DEPTH OF ALL EXISTING UTILITIES. 
<br />7. TRENCH TO BE SHORED IN ACCORDANCE WITH CALIFORNIA OSHA REGULATIONS. 
<br />8. PLACE A CONTINUOUS WIRE AND STRIP OF DETECTOR TAPE OVER ALL PIPES AND EXTEND UP 
<br />INTO ALL VALVE BOXES. TRACER WIRE IS REQUIRED ON ALL PIPE. (SEE LATEST REVISION OF 
<br />DRAWING CW -850). 
<br />9. SEE LATEST REVISION OF DRAWING CW -435 FOR TYPICAL THRUST BLOCK INSTALLATION. 
<br />10. FACILITIES SEPARATION: 
<br />A) WATER MAIN SHALL BE INSTALLED AT LEAST 10 FEET HORIZONTALLY FROM AND ONE FOOT 
<br />VERTICALLY ABOVE ANY PARALLEL PIPELINE CONVEYING SEWAGE (UNTREATED, PRIMARY, OR 
<br />SECONDARY), DISINFECTED SECONDARY RECYCLED WATER, OR HAZARDOUS FLUIDS. 
<br />B) WATER MAIN SHALL BE INSTALLED AT LEAST 4 FEET HORIZONTALLY FROM AND ONE FOOT 
<br />VERTICALLY ABOVE ANY PIPELINE CONVEYING TERTIARY RECYCLED WATER OR STORM 
<br />DRAINAGE. 
<br />C) AT CROSSINGS, WATER MAIN SHALL BE CONSTRUCTED NO LESS THAN 45 -DEGREES TO AND 
<br />AT LEAST ONE FOOT VERTICALLY ABOVE ANY PIPELINES INDICATED IN A AND B ABOVE. 
<br />D) NO CONNECTION JOINTS SHALL BE MADE IN THE WATER MAIN WITHIN EIGHT (8) HORIZONTAL 
<br />FEET OF CROSSING ANY PIPELINES INDICATED IN A AND B ABOVE. 
<br />E) WATER MAIN SHALL NOT BE INSTALLED WITHIN 100 HORIZONTAL FEET OF ANY SANITARY 
<br />LANDFILL, WASTEWATER DISPOSAL POND, OR HAZARDOUS WASTE DISPOSAL SITE. 
<br />F) WATER MAIN SHALL NOT BE INSTALLED WITHIN 25 HORIZONTAL FEET OF ANY CESSPOOL, 
<br />SEPTIC TANK, SEWAGE LEACH FIELD, SEEPAGE PIT, UNDERGROUND HAZARDOUS MATERIAL 
<br />STORAGE TANK, OR GROUNDWATER RECHARGE PROJECT SITE. 
<br />11. WHEN ASSEMBLING A PVC C-900 PIPE TO AN IRON FITTING (PUSH -ON OR MECHANICAL JOINT), 
<br />REMOVE ALL BUT 1/4 INCH OF THE FACTORY -MADE BEVEL FROM THE SPIGOT END OF THE 
<br />PIPE PRIOR TO INSTALLATION. 
<br />12. VALVE CANS AND COVERS SHALL BE PLACED OVER ALL VALVES. COVERS SHALL BE SET TO 
<br />EXISTING FINISHED GRADE AND RESET IF NECESSARY ONCE THE STREET IS AT FINAL GRADE. 
<br />(SEE LATEST REVISION OF DRAWINGS CW -14 AND CW -439). 
<br />13. NO VALVE COVERS ARE TO LIE IN SIDEWALKS, CROSS GUTTER, CURB OR DRIVEWAYS. EACH 
<br />SERVICE SHOULD ALSO BE LOCATED TO PROVIDE PROTECTION TO THE METER BOX FROM 
<br />VEHICLE TRAFFIC AND PARKING. 
<br />14. PROTECT UNDERGROUND FLEXIBLE COUPLINGS, BARE STEEL, MJ x MJ SLEEVES, AND ALL BOLTS 
<br />(INCLUDING STAINLESS STEEL) AS FOLLOWS: 
<br />A) THE ENTIRE AREA OF THE FITTING MUST BE DRY AND FREE OF DUST, DIRT, AND OTHER 
<br />FOREIGN MATTER. RUST OR OTHER FOREIGN MATTER MUST BE REMOVED BY SCRAPING OR 
<br />WIRE BRUSHING. WIPING WITH A DRY CLEAN CLOTH MAY BE NECESSARY TO REMOVE THE 
<br />PARTICLES FROM BRUSH CLEANING. ANY OIL OR GREASE MUST BE REMOVED BY USING A 
<br />LOW RESIDUE, VOLATILE PETROLEUM SOLVENT BEFORE APPLICATION OF GREASE AND 
<br />WRAPPING. 
<br />GENERAL 
<br />NOTES: 
<br />BLOWOFF (EXISTING) 
<br />8 
<br />LIMITS OF CWS OWNERSHIP FOR EACH HYDRANT: 
<br />B) 
<br />THE EXPOSED AREA SHOULD BE COATED WITH 
<br />A HEAVY COATING OF METALGUARD 301 
<br />31. O 
<br />= INDICATES FIRE HYDRANT (STOCKTON) 
<br />LEGEND: 
<br />1. CONTRACTOR SHALL BECOME FAMILIAR WITH PROJECT SURROUNDINGS, WORKING CONDITIONS, 
<br />AND SITE LIMITATIONS AND WILL INCLUDE ALLOWANCES IN THEIR BID TO COVER ANY PROJECT 
<br />CONSTRAINTS. 
<br />2. CONTRACTOR SHALL BE RESPONSIBLE FOR ADHERING TO AND COMPLYING WITH LOCAL 
<br />GOVERNING AGENCY PERMIT RESTRICTIONS, WHICH MAY AFFECT ALLOWABLE WORKING HOURS AND 
<br />NOISE LEVELS. 
<br />3. CONTRACTOR SHALL PROVIDE TRAFFIC CONTROL AS REQUIRED BY APPLICABLE LOCAL GOVERNING 
<br />AGENCY AND SHALL SUBMIT A TRAFFIC CONTROL PLAN PER CALTRANS STANDARDS TO 
<br />GOVERNING AGENCY (AS REQUIRED) PRIOR TO CONSTRUCTION. 
<br />4. CONTRACTOR SHALL APPLY CALIFORNIA STORMWATER QUALITY ASSOCIATION (CASQA) BEST 
<br />MANAGEMENT PRACTICES TO PREVENT WATER AND SEDIMENT FROM ENTERING NAVIGABLE 
<br />WATERWAYS. THE CONTRACTOR IS RESPONSIBLE FOR IDENTIFYING AND INSTALLING THE 
<br />APPLICABLE AND APPROPRIATE BMPs IDENTIFIED IN THE CASQA - STORMWATER BEST 
<br />MANAGEMENT PRACTICES HANDBOOK AVAILABLE ONLINE AT WWW.CABMPHANDBOOKS.COM. SOME 
<br />OF THE REQUIRED PRACTICES MAY OR MAY NOT BE SHOWN ON THIS SITE PLAN. 
<br />5. CONTRACTOR TO CONTACT "UNDERGROUND SERVICE ALERT" 48 HOURS PRIOR TO ANY 
<br />EXCAVATION. 
<br />6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXACT LOCATION AND 
<br />DEPTH OF ALL EXISTING UTILITIES. 
<br />7. TRENCH TO BE SHORED IN ACCORDANCE WITH CALIFORNIA OSHA REGULATIONS. 
<br />8. PLACE A CONTINUOUS WIRE AND STRIP OF DETECTOR TAPE OVER ALL PIPES AND EXTEND UP 
<br />INTO ALL VALVE BOXES. TRACER WIRE IS REQUIRED ON ALL PIPE. (SEE LATEST REVISION OF 
<br />DRAWING CW -850). 
<br />9. SEE LATEST REVISION OF DRAWING CW -435 FOR TYPICAL THRUST BLOCK INSTALLATION. 
<br />10. FACILITIES SEPARATION: 
<br />A) WATER MAIN SHALL BE INSTALLED AT LEAST 10 FEET HORIZONTALLY FROM AND ONE FOOT 
<br />VERTICALLY ABOVE ANY PARALLEL PIPELINE CONVEYING SEWAGE (UNTREATED, PRIMARY, OR 
<br />SECONDARY), DISINFECTED SECONDARY RECYCLED WATER, OR HAZARDOUS FLUIDS. 
<br />B) WATER MAIN SHALL BE INSTALLED AT LEAST 4 FEET HORIZONTALLY FROM AND ONE FOOT 
<br />VERTICALLY ABOVE ANY PIPELINE CONVEYING TERTIARY RECYCLED WATER OR STORM 
<br />DRAINAGE. 
<br />C) AT CROSSINGS, WATER MAIN SHALL BE CONSTRUCTED NO LESS THAN 45 -DEGREES TO AND 
<br />AT LEAST ONE FOOT VERTICALLY ABOVE ANY PIPELINES INDICATED IN A AND B ABOVE. 
<br />D) NO CONNECTION JOINTS SHALL BE MADE IN THE WATER MAIN WITHIN EIGHT (8) HORIZONTAL 
<br />FEET OF CROSSING ANY PIPELINES INDICATED IN A AND B ABOVE. 
<br />E) WATER MAIN SHALL NOT BE INSTALLED WITHIN 100 HORIZONTAL FEET OF ANY SANITARY 
<br />LANDFILL, WASTEWATER DISPOSAL POND, OR HAZARDOUS WASTE DISPOSAL SITE. 
<br />F) WATER MAIN SHALL NOT BE INSTALLED WITHIN 25 HORIZONTAL FEET OF ANY CESSPOOL, 
<br />SEPTIC TANK, SEWAGE LEACH FIELD, SEEPAGE PIT, UNDERGROUND HAZARDOUS MATERIAL 
<br />STORAGE TANK, OR GROUNDWATER RECHARGE PROJECT SITE. 
<br />11. WHEN ASSEMBLING A PVC C-900 PIPE TO AN IRON FITTING (PUSH -ON OR MECHANICAL JOINT), 
<br />REMOVE ALL BUT 1/4 INCH OF THE FACTORY -MADE BEVEL FROM THE SPIGOT END OF THE 
<br />PIPE PRIOR TO INSTALLATION. 
<br />12. VALVE CANS AND COVERS SHALL BE PLACED OVER ALL VALVES. COVERS SHALL BE SET TO 
<br />EXISTING FINISHED GRADE AND RESET IF NECESSARY ONCE THE STREET IS AT FINAL GRADE. 
<br />(SEE LATEST REVISION OF DRAWINGS CW -14 AND CW -439). 
<br />13. NO VALVE COVERS ARE TO LIE IN SIDEWALKS, CROSS GUTTER, CURB OR DRIVEWAYS. EACH 
<br />SERVICE SHOULD ALSO BE LOCATED TO PROVIDE PROTECTION TO THE METER BOX FROM 
<br />VEHICLE TRAFFIC AND PARKING. 
<br />14. PROTECT UNDERGROUND FLEXIBLE COUPLINGS, BARE STEEL, MJ x MJ SLEEVES, AND ALL BOLTS 
<br />(INCLUDING STAINLESS STEEL) AS FOLLOWS: 
<br />A) THE ENTIRE AREA OF THE FITTING MUST BE DRY AND FREE OF DUST, DIRT, AND OTHER 
<br />FOREIGN MATTER. RUST OR OTHER FOREIGN MATTER MUST BE REMOVED BY SCRAPING OR 
<br />WIRE BRUSHING. WIPING WITH A DRY CLEAN CLOTH MAY BE NECESSARY TO REMOVE THE 
<br />PARTICLES FROM BRUSH CLEANING. ANY OIL OR GREASE MUST BE REMOVED BY USING A 
<br />LOW RESIDUE, VOLATILE PETROLEUM SOLVENT BEFORE APPLICATION OF GREASE AND 
<br />WRAPPING. 
<br />COUNTY OF SAN JOAQUIN NOTES: 
<br />TRENCH CUT POLICY 
<br />GENERAL REQUIREMENTS 
<br />A. RESURFACING REQUIREMENTS SPECIFIED IN THIS POLICY ARE IN ADDITION TO THE TRENCH RESURFACING 
<br />REQUIREMENTS SPECIFIED BY COUNTY STANDARD DRAWING NO. R-29. 
<br />B. FOR THE PURPOSE OF THIS POLICY, "SURFACING AGE" IS DEFINED AS THE AGE OF THE MOST RECENTLY 
<br />COMPLETED ROADWAY SURFACING, INCLUDING CONSTRUCTION, RECONSTRUCTION, OR MAJOR OVERLAY. 
<br />C. WHERE THE APPLICATION OF SEAL COAT IS REQUIRED, A TYPE II SLURRY SEAL WILL BE USED IN ACCORDANCE 
<br />WITH STATE STANDARD SPECIFICATIONS, SECTION 37-2. 
<br />D. THE PERMITTEE MUST POST A ONE-YEAR MAINTENANCE BOND OR CASH DEPOSIT, IN AN AMOUNT SPECIFIED BY 
<br />THE DEPARTMENT. 
<br />E. ALL PAVEMENT MARKINGS DESTROYED OR OBLITERATED MUST BE REPLACED IN KIND BY THE PERMITTEE. TYPICAL 
<br />PAVEMENT MARKINGS INCLUDE, BUT ARE NOT LIMITED TO, LANE LINES, RAISED PAVEMENT MARKERS, AND 
<br />MISCELLANEOUS DELINEATORS. 
<br />F. THE PERMITTEE IS RESPONSIBLE FOR SURVEY MONUMENTS DISTURBED BY TRENCHING AND IS REQUIRED TO FILE 
<br />A CORNER RECORD AND TO REESTABLISH THEM USING A LICENSED LAND SURVEYOR AFTER THE TRENCH 
<br />RESTORATION IS COMPLETED. 
<br />G. FUNCTIONAL CLASSIFICATION AND PUBLIC WORKS PROJECT ADVERTISING SCHEDULES ARE REFERENCES FOR THIS 
<br />POLICY. 
<br />H. TO FACILITATE SCHEDULING AND PLANNING, PUBLIC WORKS STAFF WILL MAKE AVAILABLE THE MOST CURRENT 
<br />PROJECT ADVERTISING SCHEDULE AT THE MONTHLY UTILITY COORDINATION MEETING AND MAKE IT AVAILABLE TO THE 
<br />PUBLIC, AT THE PERMITS COUNTER, IN JANUARY EACH YEAR. 
<br />COLLECTORS, ARTERIALS AND EXPRESSWAYS 
<br />A. RESURFACING AGE LESS THAN THREE (3) YEARS: NO PAVEMENT CUTS. EXCEPTIONS MAY BE APPROVED WITH 
<br />ACCORDANCE WITH SECTION 2-5.04 EXCEPTIONS. 
<br />B. SURFACING AGE THREE (3) YEARS AND OVER: 
<br />1. LONGITUDINAL TRENCH CUTTING IN PAVED SHOULDER AREAS: 
<br />THE ENTIRE SHOULDER OF THE ROAD IS TO BE RESURFACED. THE EXISTING SURFACING ADJACENT TO 
<br />THE TRENCHED AREA SHALL BE PLANED TO ACCOMMODATE THE OVERLAY IN A MANNER THAT DOES 
<br />NOT CAUSE DRAINAGE CONCERNS. THE NEAREST PAVEMENT CUT SHALL BE A MINIMUM OF THREE (3) 
<br />FEET FORM THE EDGE OF PAVEMENT OR THE REMAINING PAVEMENT SHALL ALSO BE REMOVED AND 
<br />REPLACED. (SEE COUNTY STANDARDS DRAWING NO. R-37). 
<br />2. LONGITUDINAL TRENCHES WITHIN TRAVELED LANES: 
<br />THE ENTIRE TRAVELED LANE WHERE THE TRENCH IS LOCATED IS TO BE RESURFACED WITH ONE(1) 
<br />INCH 
<br />ASPHALT CONCRETE OVERLAY. THE EXISTING SURFACING ADJACENT TO THE TRENCHED AREA SHALL BE 
<br />PLANED TO ACCOMMODATE THE OVERLAY IN A MANNER THAT DOES NOT CAUSE DRAINAGE CONCERNS. 
<br />THE OVERLAY SHALL BE IN ACCORDANCE WITH STATE STANDARDS SPECIFICATIONS SECTION 39. 
<br />AGGREGATE GRADATION SHALL BE CONSISTENT WITH THE EXISTING SURFACING MATERIAL. (SEE COUNTY 
<br />NOTE: 
<br />BEST LOCATION FOR WATER MAIN TO BE DETERMINED IN THE FIELD BY CONTRACTOR AND CAL 
<br />WATER REPRESENTATIVE. TOPOGRAPHY, UTILITIES & DIMENSIONS SHOWN ARE APPROXIMATE. 
<br />CONTRACTOR SHALL FIELD VERIFY EXACT LOCATION OF ALL EX. UTILITIES PRIOR TO EXCAVATION & 
<br />ADJUST MATERIAL AS REQUIRED FOR ACTUAL ALIGNMENT. ALL NEW MAIN INSTALLATION SHALL MEET 
<br />THE CALIFORNIA REGULATIONS RELATED TO DRINKING WATER, TITLE 22 CHAPTER 16 ARTICLE 4 
<br />SECTION 64572 "WATER MAIN SEPARATION" REQUIREMENTS & CWS CO. STANDARDS. 
<br />ABANDONMENT NOTE: 
<br />THE CONTRACTOR IS RESPONSIBLE TO ABANDON ALL PIPE ENDS BY 
<br />PLUGGING WITH BRICK AND MORTAR. ABANDON ALL GATE VALVES BY 
<br />REMOVING COVER, CUT CASING DOWN TO SUBGRADE, AND BACKFILL 
<br />VALVE CASING WITH CEMENT SLURRY TO FILL ALL VOIDS, AND 
<br />REPLACE BASE ROCK & PERMANENT AC PAVEMENT PER GOVERNING 
<br />AGENCY'S REQUIREMENTS. 
<br />STANDARDS DRAWING NO. R-37). 
<br />3. CROSS -CUTTING: 
<br />CROSS -CUTTING IS ALLOWED AT A MINIMUM INTERVAL OF 150 FEET. AT EACH CROSS -CUT LOCATION, A 
<br />MINIMUM OF TEN (10) FEET ON EACH SIDE OF TRENCH SHALL BE PLANED AND RESURFACED WITH ONE 
<br />(1) INCH ASPHALT CONCRETE. IF CROSS -CUTS ARE WITHIN THE 150 FT MINIMUM INTERVAL, THE ENTIRE 
<br />SECTION BETWEEN THE FIRST AND LAST CROSS -CUT SHALL BE PLANED AND RESURFACED WITH ONE (1) 
<br />INCH ASPHALT CONCRETE. (SEE COUNTY STANDARDS DRAWING NO. R-36). 
<br />4. THE CONDITIONS DESCRIBED IN PARAGRAPHS 1, 2 & 3 ABOVE WILL NOT APPLY IF RESURFACING IS 
<br />SCHEDULED WITHIN TWO YEARS. 
<br />LOCAL ROADS 
<br />A. SURFACING AGE UNDER THREE (3) YEARS: NO PAVEMENT CUTS ALLOWED. EXCEPTIONS MAY BE APPROVED IN 
<br />ACCORDANCE WITH SECTION 2-5.04 EXCEPTIONS. 
<br />B. SURFACING AGE THREE (3) TO FIVE (5) YEARS: 
<br />1. LONGITUDINAL CUTS ARE PERMITTED. A SEAL COAT IS REQUIRED FOR THAT HALF OF THE ROADWAY 
<br />CONTAINING THE TRENCH. (SEE COUNTY STANDARDS DRAWING NO. R-37). 
<br />2. CROSS -CUTTING IS ALLOWED UNDER THE SAME CONDITIONS AS SECTION 2-5.02(B)(3). IF CROSS -CUTS 
<br />OCCUR WITHIN THE 150 FEET INTERVAL, RESURFACING MAY BE SUBSTITUTED WITH A SLURRY SEAL 
<br />FOR THAT HALF OF THE ROAD WAY. (SEE COUNTY STANDARDS DRAWING NO. R-36). 
<br />EXCEPTIONS 
<br />EXCAVATION IS PROHIBITED IN NEWLY RENOVATED COUNTY ROADWAYS FOR THREE (3) YEARS AFTER A NOTICE OF 
<br />COMPLETION HAS BEEN FILED FOR A ROADWAY IMPROVEMENT PROJECT, OR A NEW ROADWAY HAS BEEN ACCEPTED. THE 
<br />DIRECTOR OF PUBLIC WORKS MAY APPROVE EXCEPTIONS THAT ARE IN THE BEST INTEREST OF THE PUBLIC, INCLUDING 
<br />BUT NOT LIMITED TO: 
<br />A. AN EMERGENCY THAT ENDANGERS LIFE OR PROPERTY. 
<br />B. FOR REPAIR OR MODIFICATION TO PREVENT INTERRUPTION OF ESSENTIAL UTILITY SERVICE. 
<br />C. FOR RELOCATION WORK THAT IS MANDATED BY COUNTY, STATE OR FEDERAL LAW. 
<br />D. FOR SERVICE FOR BUILDING WHERE NO REASONABLE MEANS OF PROVIDING SERVICE EXISTS. 
<br />E. FOR POTHOLING TO VERIFY UTILITY DEPTH OR LOCATIONS. 
<br />F. FOR TRENCHLESS EXCAVATIONS GREATER THAN THREE FEET IN DEPTH OF COVER OVER THE UTILITY FACILITY, AND 
<br />NOT REQUIRING A SIGNIFICANT SURFACE INCISION GREATER THAN INDUSTRY BORE PIT STANDARDS. 
<br />EXCEPTIONS MUST BE REQUESTED AND SUBMITTED IN WRITING TO THE DEPARTMENT. PAVEMENT OF A NON REFUNDABLE 
<br />PROCESSING FEE IS ALSO REQUIRED. EXCEPTIONS WILL BE REVIEWED USING THE DEPARTMENTS ACTION APPROVAL 
<br />PROCESS, WHICH REQUIRED THE RECOMMENDATION OF A DEPUTY DIRECTOR. 
<br />ABANDON IN PLACE 
<br />WITHIN THIRTY (30) DAYS AFTER SERVICE OF A 45 DAY NOTICE FROM SAN JOAQUIN COUNTY PUBLIC WORKS TO 
<br />RELOCATE, CHANGE GRADE, CONSTRUCT, USE, MAINTAIN, CHANGE OR MODIFY ANY STREET IMPROVEMENTS OR 
<br />COUNTY -OWNED UTILITY FACILITIES, CALIFORNIA WATER SERVICE SHALL AT ITS SOLE COST AND EXPENSE, BEGIN THE 
<br />NECESSARY WORK TO REMOVE THEIR ABANDONED FACILITIES IN CONFLICT. 
<br />POTHOLE AND VERIFY: 
<br />CONTRACTOR WILL BE RESPONSIBLE FOR THE 
<br />VERIFICATION OF EXACT DEPTHS AND LOCATION OF 
<br />ALL EXISTING UTILITIES AND PROPOSED FACILITIES IN 
<br />THE FIELD PRIOR TO COMMENCING WORK. LOCATIONS 
<br />SHOWN ON THE PLANS AREA APPROXIMATE AND FOR 
<br />GENERAL INFORMATION ONLY. 
<br />NOTE: 
<br />TIE-IN ALL EXISTING (LONG/ SHORT) SERVICE TO 
<br />PROPOSED CWS PIPE AFTER INSTALLATION. 
<br />PIPELINE CROSSING INFORMATION 
<br />AT WATER MAIN CROSSINGS IN CONFLICT WITH OTHER FACILITIES: 
<br />WHEN THE WATER MAIN IS IN CONFLICT WITH EX. FACILITIES OR PROPOSED FACILITIES THAT REQUIRE MORE 
<br />THAN A 2 FOOT ADJUSTMENT FROM THE NOMINAL 4 FEET OF COVER, A FABRICATED STEEL CEMENT MORTAR 
<br />LINED AND CEMENT COATED OFFSET SHALL BE INSTALLED AT THE CROSSING PER CWS CO. STANDARDS. 
<br />*DESIGNATES CL&C OFFSET REQUIRED 
<br />PER CWS REPRESENTATIVE DIRECTION, FOR UNANTICIPATED CONFLICTS FOUND DURING CONSTRUCTION THAT 
<br />REQUIRE ADJUSTMENT OF NEW MAIN FROM THE NOMINAL 4 FEET OF COVER, A FIELD BUILT VERTICAL OFFSET 
<br />MAY BE CONSTRUCTED. SEE REVERSE KICKER DETAIL IF FIELD CONSTRUCTING VERTICAL OFFSETS AROUND 
<br />CROSSINGS. �\ 
<br />\ ,( INDICATES A SANITARY SEWER (SS) OR STORM DRAIN (SD) CROSSING. 
<br />PIPELINE CROSSINGS �SHALL BE INSTALLED OVER SS AND SD CROSSINGS PER GENERAL NOTE 10. PIPELINE 
<br />SHALL HAVE MINIMUM 2.5' COVER AND MINIMUM 1' VERTICAL SEPARATION BETWEEN NEW PIPELINE AND SS 
<br />OR SO CROSSINGS. THE ANGLE OF CROSSING SHALL BE FROM 45' TO 90'. ANY CROSSINGS NOT ABLE TO 
<br />BE INSTALLED PER CCR TITLE 22 "WATER MAIN SEPARATION" REQUIREMENTS SHALL BE INSTALLED PER STATE 
<br />APPROVED VARIANCE REQUEST. 
<br />GAS 
<br />_^om 
<br />ss 
<br />SD 
<br />ABANDON 
<br />CENTER LINE 
<br />EASEMENT 
<br />EXISTING WATER 
<br />GAS 
<br />INTERIOR LOT LINES 
<br />OIL 
<br />PROPERTY LINE 
<br />PROPOSED WATER 
<br />RIGHT-OF-WAY (RAV) 
<br />SANITARY SEWER 
<br />STORM DRAIN 
<br />STRUCTURE 
<br />ASPHALT 
<br />CONCRETE PAVEMENT 
<br />DIRT/EARTH 
<br />LANDSCAPE 
<br />X) 
<br />GREASE BY THE GLOVE METHOD TO A THICKNESS OF AT LEAST 1/4". 
<br />x• 
<br />BLOWOFF (EXISTING) 
<br />8 
<br />LIMITS OF CWS OWNERSHIP FOR EACH HYDRANT: 
<br />E 
<br />C) FIRMLY WRAP THE ENTIRE GREASE AREA WITH ONE LAYER, HALF -LAPPED, OF A WOVEN 
<br />1 - 6 INCH OUTLET TEE OR ELL PDXFLG, DI 
<br />CATCH BASIN 
<br />GLASS FILAMENT MESH (RES OR BIT WRAP, 4" WIDE). 
<br />1 - 6 INCH GATE VALVE FLGxMJ 
<br />�y 
<br />ELBOW, 45° 
<br />1 -VALVE CASING & COVER ASSEMBLY 
<br />ELBOW, 90° 
<br />D) APPLY A SECOND LAYER OF METALGUARD 301 GREASE ON TOP OF THE GLASS FILAMENT BY 
<br />+/- 10 FEET OF 6 INCH DUCTILE IRON PIPE 
<br />& 
<br />THE GLOVE METHOD TO A THICKNESS OF AT LEAST 1/4". 
<br />1 - 6x42 INCH FIRE HYDRANT BURY FLGXMJ 
<br />FLEX CPLG. (OR AS NOTED) 
<br />E) FIRMLY WRAP THE ENTIRE GREASE AREA WITH A SECOND LAYER, HALF -LAPPED, OF THE 
<br />1 - 6x12 INCH FIRE HYDRANT EXTENSION 
<br />• 
<br />WOVEN GLASS FILAMENT MESH. 
<br />1 - SET 3/4" x 3-1/2" #304 SS BOLTS & NUTS, 
<br />REDUCER (PROPOSED) 
<br />No 
<br />AND GASKETS FOR HYDRANT 
<br />ss 
<br />F) COVER THE ENTIRE MESH WRAPPED AREA OF THE FITTING WITH A THIRD AND FINAL COATING 
<br />1 - SET 3/4" x 3-1/2" #304 SS BOLTS & NUTS, 
<br />STORM DRAIN MANHOLE 
<br />AT LEAST 1/4" THICK OF METALGUARD 301 GREASE BY THE GLOVE METHOD. 
<br />AND GASKETS FOR HYDRANT BREAK -OFF 
<br />wu 0 
<br />WATER METER 
<br />2 - SETS 3/4" x 3-1/2" #304 SS BOLTS & NUTS, 
<br />= FLANGE BOTH ENDS 
<br />G) FIRMLY APPLY 2 LAYERS OF POLYWRAP, HALF -LAPPED, OVER ALL AREAS OF THE COATED 
<br />AND GASKETS FOR GATE VALVE 
<br />RIP 
<br />AND WRAPPED FITTING. BACKFILLING MAY FOLLOW IMMEDIATELY AFTER THIS WRAPPING. 
<br />FL 
<br />= FLOW LINE 
<br />FOE 
<br />POLYWRAP TUBING, PVC TAPE, LINE GUARD AND MISC. 
<br />15. 
<br />TRENCH BACKFILL AND PAVING SHALL CONFORM TO TRENCH SECTION DETAILS AND ALL 
<br />COATING MATERIAL. 
<br />= FINISH SURFACE 
<br />GOVERNING AGENCY REQUIREMENTS. 
<br />= GROUND BOX 
<br />GPM 
<br />= GALLONS PER MINUTE 
<br />FIRE HYDRANT: 
<br />16. 
<br />NEW PIPELINE SHALL BE INSTALLED WITH 4 FEET OF COVER, EXCEPT WHERE SPECIFIED. 
<br />= HORSEPOWER 
<br />IBC 
<br />= INTERNATIONAL BUILDING CODE 
<br />CAL WATER'S PORTION OF THE FIRE HYDRANT INSTALLATION 
<br />17. 
<br />CONTRACTOR SHALL LIMIT DAILY TRENCHING OPERATIONS TO THE LENGTH OF PIPE THAT CAN BE 
<br />SHALL BE LIMITED TO THE PDXFLG TEE & FLGXMJ GATE VALVE. 
<br />MH 
<br />INSTALLED AND BACKFILLED THAT DAY. 
<br />THE TEE, GATE VALVE, GASKET & BOLTS SHALL BE PROVIDED BY 
<br />18. 
<br />CONTRACTOR SHALL INSTALL NEW MAIN AND ADJUST FROM NOMINAL LINE AND GRADE TO MATCH 
<br />OTHERS. THE REMAINDER OF THE FIRE HYDRANT MATERIALS 
<br />MPT 
<br />THE EXISTING FACILITIES AT ALL LOCATIONS. THE CONTRACTOR SHALL INSTALL A TEMPORARY CAP 
<br />SHALL BE INSTALLED BY OTHERS WITH THE CITY OF STOCKTON 
<br />TIE-IN PER DETAILS: B, 
<br />AND BLOW -OFF AT TIE-IN LOCATIONS FOR TESTING, (SEE LATEST REVISION OF DRAWINGS 
<br />APPROVAL. THE CITY OF STOCKTON OWNS THE FIRE HYDRANT 
<br />TON 
<br />12" MAIN 
<br />ASSEMBLY. (HYDRANT ASSEMBLY SHALL BE APPROVED BY THE 
<br />±60' 
<br />CW -122 & CW -638). CONTRACTOR WILL TIE THE NEW MAIN FROM THIS LOCATION. 
<br />CITY OF STOCKTON) 
<br />19. 
<br />THE NEW PIPELINE SHALL BE TESTED AT 150 PSI FOR A PERIOD OF 4 HOURS. SEE 
<br />TRACER WIRE #12 AWG 
<br />INSULATION 
<br />SOLID COPPER w/ 45 MILS 
<br />SPECIFICATIONS TO DETERMINE EXACT TESTING REQUIREMENTS. 
<br />(THE FIRE CHIEF WILL MAKE THE FINAL CHOICE OF FIRE 
<br />LINEGUARD TAPE 
<br />= VICTAULIC BOTH ENDS 
<br />HYDRANT HEAD WITH CAL WATER APPROVAL.) 
<br />20. 
<br />TIE-INS TO BE MADE AT A TIME THAT IS CONVENIENT TO OWNER WHICH MAY BE AT NIGHTS OR 
<br />12" DI PIPE 
<br />VOE 
<br />WEEKENDS. THE ADDITIONAL COST DUE TO OVERTIME PAY SHALL BE AT OWNER'S EXPENSE. 
<br />A BREAK -OFF CHECK VALVE MAY BE REQUIRED IF SPECIFIED BY 
<br />21. 
<br />CONTRACTOR SHALL PROVIDE MISC. MATERIAL REQUIRED TO COMPLETE THE TIE-IN SUCH AS, 
<br />DISTRICT PERSONNEL. USE CLOW MODEL LB400 OR APPROVED 
<br />12" GATE VALVE, PO 
<br />BUT NOT LIMITED TO: 
<br />EQUAL. 
<br />2 
<br />PROTECTION COATING MATERIAL FOR PIPE AND FITTINGS, LINEGUARD TAPE, CONCRETE FOR 
<br />COVER ASSEMBLY 
<br />VOL 
<br />THRUST BLOCKS, EMBEDMENT BACKFILL AROUND AND OVER THE PIPE, FINAL BACKFILL TO MEET 
<br />12" 90' ELBOW, PO 
<br />ZN 
<br />COMPACTION REQUIREMENTS, AND PAVEMENT REPLACEMENT. 
<br />1 
<br />22. 
<br />CONTRACTOR SHALL BE RESPONSIBLE TO ABANDON ALL PIPE ENDS BY PLUGGING WITH BRICK 
<br />SCALE: 
<br />1 
<br />AND MORTAR. ABANDON ALL GATE VALVES BY REMOVING COVER, CUT CASING DOWN TO 
<br />SUBGRADE, AND BACKFILL VALVE CASING WITH CONCRETE SLURRY TO REMOVE VOIDS. REPLACE 
<br />METAL GUARD #301 - 
<br />(FLEX. CPLG., FLGS... ) 
<br />1 GAL. PER 2 FITTINGS OF BARE STEEL 
<br />BASE ROCK AND PERMANENT PAVEMENT AS NECESSARY. WHEN REMOVING EXISTING FITTINGS, 
<br />RES -BIT WRAP (100' ROLLS) - 1 RL. F/EVERY GAL. 
<br />GUARD #301 
<br />OF METAL 
<br />CONTRACTOR SHALL ALSO REMOVE EXISTING CONCRETE THRUST BLOCK. 
<br />#80 SACKS/CONCRETE 
<br />23. 
<br />CONTRACTOR SHALL RESTORE LAWN, GUTTER, PAVEMENT, BERM, AND CURB TO MATCH EXISTING 
<br />PER GOVERNING AGENCY'S STANDARDS. 
<br />24. 
<br />SPOILS SHALL NOT REMAIN ON-SITE. DISPOSAL OF ALL PROJECT -GENERATED SPOILS SHALL BE 
<br />AT A FACILITY LICENSED AND CLASSIFIED TO ACCEPT THE MATERIALS. CONTRACTOR TO PROVIDE 
<br />OWNER WITH A FORMAL RECEIPT FROM THE ACCEPTING FACILITY. ALL MATERIALS THAT WILL 
<br />REQUIRE TESTING PRIOR TO DISPOSAL SHALL BE SAMPLED AND TESTED IN ACCORDANCE WITH 
<br />THE REQUIREMENTS OF THE DISPOSAL FACILITY IN ADVANCE OF THE NEED FOR DISPOSAL. 
<br />25. 
<br />THE LIST OF MATERIALS FOR THIS PROJECT IS FOR CWS CO. ESTIMATING AND REFERENCE 
<br />PURPOSES ONLY, AND IS NOT INTENDED AS A FULL TAKE -OFF OF ALL MATERIALS REQUIRED TO 
<br />COMPLETE THE PROJECT PER CWS CO. STANDARD SPECIFICATIONS. 
<br />26. 
<br />AT TIE-INS, CONTRACTOR SHALL SPRAY OR SWAB ALL FITTINGS WITH CHLORINE SOLUTION FOR 
<br />DISINFECTION PRIOR TO FINAL CONNECTIONS. 
<br />27. 
<br />CONTRACTOR TO ENSURE AIR IN THE PIPELINE IS REMOVED USING EXISTING OUTLETS SUCH AS 
<br />FIRE HYDRANTS AND BLOW OFFS. CONTRACTOR IS RESPONSIBLE FOR INSTALLING AIR RELEASES 
<br />IF EXISTING OUTLETS ARE INSUFFICIENT. 
<br />28. 
<br />ALL WORK SHALL COMPLY WITH CAL WATER SPECIFICATIONS FOR MATERIALS, INSTALLATION, 
<br />DISINFECTION AND DECHLORINATION PER LATEST REVISION OF DRAWING CW -863. 
<br />29. 
<br />ALL SLIP-ON WELDING FLANGES SHALL BE RAISED -FACE SLIP-ON WELDING FLANGES. 
<br />30. 
<br />ALIGNMENT OF NEW MAIN MAY INCLUDE CROSSING UNDER OVERHEAD UTILITY SERVICE 
<br />CONNECTIONS AND LINES. CONTRACTOR IS RESPONSIBLE TO ENSURE ALL STATE AND FEDERAL 
<br />OSHA SAFETY REGULATIONS ARE FOLLOWED WHEN PERFORMING WORK NEAR OVERHEAD UTILITY 
<br />LINES. 
<br />COUNTY OF SAN JOAQUIN NOTES: 
<br />TRENCH CUT POLICY 
<br />GENERAL REQUIREMENTS 
<br />A. RESURFACING REQUIREMENTS SPECIFIED IN THIS POLICY ARE IN ADDITION TO THE TRENCH RESURFACING 
<br />REQUIREMENTS SPECIFIED BY COUNTY STANDARD DRAWING NO. R-29. 
<br />B. FOR THE PURPOSE OF THIS POLICY, "SURFACING AGE" IS DEFINED AS THE AGE OF THE MOST RECENTLY 
<br />COMPLETED ROADWAY SURFACING, INCLUDING CONSTRUCTION, RECONSTRUCTION, OR MAJOR OVERLAY. 
<br />C. WHERE THE APPLICATION OF SEAL COAT IS REQUIRED, A TYPE II SLURRY SEAL WILL BE USED IN ACCORDANCE 
<br />WITH STATE STANDARD SPECIFICATIONS, SECTION 37-2. 
<br />D. THE PERMITTEE MUST POST A ONE-YEAR MAINTENANCE BOND OR CASH DEPOSIT, IN AN AMOUNT SPECIFIED BY 
<br />THE DEPARTMENT. 
<br />E. ALL PAVEMENT MARKINGS DESTROYED OR OBLITERATED MUST BE REPLACED IN KIND BY THE PERMITTEE. TYPICAL 
<br />PAVEMENT MARKINGS INCLUDE, BUT ARE NOT LIMITED TO, LANE LINES, RAISED PAVEMENT MARKERS, AND 
<br />MISCELLANEOUS DELINEATORS. 
<br />F. THE PERMITTEE IS RESPONSIBLE FOR SURVEY MONUMENTS DISTURBED BY TRENCHING AND IS REQUIRED TO FILE 
<br />A CORNER RECORD AND TO REESTABLISH THEM USING A LICENSED LAND SURVEYOR AFTER THE TRENCH 
<br />RESTORATION IS COMPLETED. 
<br />G. FUNCTIONAL CLASSIFICATION AND PUBLIC WORKS PROJECT ADVERTISING SCHEDULES ARE REFERENCES FOR THIS 
<br />POLICY. 
<br />H. TO FACILITATE SCHEDULING AND PLANNING, PUBLIC WORKS STAFF WILL MAKE AVAILABLE THE MOST CURRENT 
<br />PROJECT ADVERTISING SCHEDULE AT THE MONTHLY UTILITY COORDINATION MEETING AND MAKE IT AVAILABLE TO THE 
<br />PUBLIC, AT THE PERMITS COUNTER, IN JANUARY EACH YEAR. 
<br />COLLECTORS, ARTERIALS AND EXPRESSWAYS 
<br />A. RESURFACING AGE LESS THAN THREE (3) YEARS: NO PAVEMENT CUTS. EXCEPTIONS MAY BE APPROVED WITH 
<br />ACCORDANCE WITH SECTION 2-5.04 EXCEPTIONS. 
<br />B. SURFACING AGE THREE (3) YEARS AND OVER: 
<br />1. LONGITUDINAL TRENCH CUTTING IN PAVED SHOULDER AREAS: 
<br />THE ENTIRE SHOULDER OF THE ROAD IS TO BE RESURFACED. THE EXISTING SURFACING ADJACENT TO 
<br />THE TRENCHED AREA SHALL BE PLANED TO ACCOMMODATE THE OVERLAY IN A MANNER THAT DOES 
<br />NOT CAUSE DRAINAGE CONCERNS. THE NEAREST PAVEMENT CUT SHALL BE A MINIMUM OF THREE (3) 
<br />FEET FORM THE EDGE OF PAVEMENT OR THE REMAINING PAVEMENT SHALL ALSO BE REMOVED AND 
<br />REPLACED. (SEE COUNTY STANDARDS DRAWING NO. R-37). 
<br />2. LONGITUDINAL TRENCHES WITHIN TRAVELED LANES: 
<br />THE ENTIRE TRAVELED LANE WHERE THE TRENCH IS LOCATED IS TO BE RESURFACED WITH ONE(1) 
<br />INCH 
<br />ASPHALT CONCRETE OVERLAY. THE EXISTING SURFACING ADJACENT TO THE TRENCHED AREA SHALL BE 
<br />PLANED TO ACCOMMODATE THE OVERLAY IN A MANNER THAT DOES NOT CAUSE DRAINAGE CONCERNS. 
<br />THE OVERLAY SHALL BE IN ACCORDANCE WITH STATE STANDARDS SPECIFICATIONS SECTION 39. 
<br />AGGREGATE GRADATION SHALL BE CONSISTENT WITH THE EXISTING SURFACING MATERIAL. (SEE COUNTY 
<br />NOTE: 
<br />BEST LOCATION FOR WATER MAIN TO BE DETERMINED IN THE FIELD BY CONTRACTOR AND CAL 
<br />WATER REPRESENTATIVE. TOPOGRAPHY, UTILITIES & DIMENSIONS SHOWN ARE APPROXIMATE. 
<br />CONTRACTOR SHALL FIELD VERIFY EXACT LOCATION OF ALL EX. UTILITIES PRIOR TO EXCAVATION & 
<br />ADJUST MATERIAL AS REQUIRED FOR ACTUAL ALIGNMENT. ALL NEW MAIN INSTALLATION SHALL MEET 
<br />THE CALIFORNIA REGULATIONS RELATED TO DRINKING WATER, TITLE 22 CHAPTER 16 ARTICLE 4 
<br />SECTION 64572 "WATER MAIN SEPARATION" REQUIREMENTS & CWS CO. STANDARDS. 
<br />ABANDONMENT NOTE: 
<br />THE CONTRACTOR IS RESPONSIBLE TO ABANDON ALL PIPE ENDS BY 
<br />PLUGGING WITH BRICK AND MORTAR. ABANDON ALL GATE VALVES BY 
<br />REMOVING COVER, CUT CASING DOWN TO SUBGRADE, AND BACKFILL 
<br />VALVE CASING WITH CEMENT SLURRY TO FILL ALL VOIDS, AND 
<br />REPLACE BASE ROCK & PERMANENT AC PAVEMENT PER GOVERNING 
<br />AGENCY'S REQUIREMENTS. 
<br />STANDARDS DRAWING NO. R-37). 
<br />3. CROSS -CUTTING: 
<br />CROSS -CUTTING IS ALLOWED AT A MINIMUM INTERVAL OF 150 FEET. AT EACH CROSS -CUT LOCATION, A 
<br />MINIMUM OF TEN (10) FEET ON EACH SIDE OF TRENCH SHALL BE PLANED AND RESURFACED WITH ONE 
<br />(1) INCH ASPHALT CONCRETE. IF CROSS -CUTS ARE WITHIN THE 150 FT MINIMUM INTERVAL, THE ENTIRE 
<br />SECTION BETWEEN THE FIRST AND LAST CROSS -CUT SHALL BE PLANED AND RESURFACED WITH ONE (1) 
<br />INCH ASPHALT CONCRETE. (SEE COUNTY STANDARDS DRAWING NO. R-36). 
<br />4. THE CONDITIONS DESCRIBED IN PARAGRAPHS 1, 2 & 3 ABOVE WILL NOT APPLY IF RESURFACING IS 
<br />SCHEDULED WITHIN TWO YEARS. 
<br />LOCAL ROADS 
<br />A. SURFACING AGE UNDER THREE (3) YEARS: NO PAVEMENT CUTS ALLOWED. EXCEPTIONS MAY BE APPROVED IN 
<br />ACCORDANCE WITH SECTION 2-5.04 EXCEPTIONS. 
<br />B. SURFACING AGE THREE (3) TO FIVE (5) YEARS: 
<br />1. LONGITUDINAL CUTS ARE PERMITTED. A SEAL COAT IS REQUIRED FOR THAT HALF OF THE ROADWAY 
<br />CONTAINING THE TRENCH. (SEE COUNTY STANDARDS DRAWING NO. R-37). 
<br />2. CROSS -CUTTING IS ALLOWED UNDER THE SAME CONDITIONS AS SECTION 2-5.02(B)(3). IF CROSS -CUTS 
<br />OCCUR WITHIN THE 150 FEET INTERVAL, RESURFACING MAY BE SUBSTITUTED WITH A SLURRY SEAL 
<br />FOR THAT HALF OF THE ROAD WAY. (SEE COUNTY STANDARDS DRAWING NO. R-36). 
<br />EXCEPTIONS 
<br />EXCAVATION IS PROHIBITED IN NEWLY RENOVATED COUNTY ROADWAYS FOR THREE (3) YEARS AFTER A NOTICE OF 
<br />COMPLETION HAS BEEN FILED FOR A ROADWAY IMPROVEMENT PROJECT, OR A NEW ROADWAY HAS BEEN ACCEPTED. THE 
<br />DIRECTOR OF PUBLIC WORKS MAY APPROVE EXCEPTIONS THAT ARE IN THE BEST INTEREST OF THE PUBLIC, INCLUDING 
<br />BUT NOT LIMITED TO: 
<br />A. AN EMERGENCY THAT ENDANGERS LIFE OR PROPERTY. 
<br />B. FOR REPAIR OR MODIFICATION TO PREVENT INTERRUPTION OF ESSENTIAL UTILITY SERVICE. 
<br />C. FOR RELOCATION WORK THAT IS MANDATED BY COUNTY, STATE OR FEDERAL LAW. 
<br />D. FOR SERVICE FOR BUILDING WHERE NO REASONABLE MEANS OF PROVIDING SERVICE EXISTS. 
<br />E. FOR POTHOLING TO VERIFY UTILITY DEPTH OR LOCATIONS. 
<br />F. FOR TRENCHLESS EXCAVATIONS GREATER THAN THREE FEET IN DEPTH OF COVER OVER THE UTILITY FACILITY, AND 
<br />NOT REQUIRING A SIGNIFICANT SURFACE INCISION GREATER THAN INDUSTRY BORE PIT STANDARDS. 
<br />EXCEPTIONS MUST BE REQUESTED AND SUBMITTED IN WRITING TO THE DEPARTMENT. PAVEMENT OF A NON REFUNDABLE 
<br />PROCESSING FEE IS ALSO REQUIRED. EXCEPTIONS WILL BE REVIEWED USING THE DEPARTMENTS ACTION APPROVAL 
<br />PROCESS, WHICH REQUIRED THE RECOMMENDATION OF A DEPUTY DIRECTOR. 
<br />ABANDON IN PLACE 
<br />WITHIN THIRTY (30) DAYS AFTER SERVICE OF A 45 DAY NOTICE FROM SAN JOAQUIN COUNTY PUBLIC WORKS TO 
<br />RELOCATE, CHANGE GRADE, CONSTRUCT, USE, MAINTAIN, CHANGE OR MODIFY ANY STREET IMPROVEMENTS OR 
<br />COUNTY -OWNED UTILITY FACILITIES, CALIFORNIA WATER SERVICE SHALL AT ITS SOLE COST AND EXPENSE, BEGIN THE 
<br />NECESSARY WORK TO REMOVE THEIR ABANDONED FACILITIES IN CONFLICT. 
<br />POTHOLE AND VERIFY: 
<br />CONTRACTOR WILL BE RESPONSIBLE FOR THE 
<br />VERIFICATION OF EXACT DEPTHS AND LOCATION OF 
<br />ALL EXISTING UTILITIES AND PROPOSED FACILITIES IN 
<br />THE FIELD PRIOR TO COMMENCING WORK. LOCATIONS 
<br />SHOWN ON THE PLANS AREA APPROXIMATE AND FOR 
<br />GENERAL INFORMATION ONLY. 
<br />NOTE: 
<br />TIE-IN ALL EXISTING (LONG/ SHORT) SERVICE TO 
<br />PROPOSED CWS PIPE AFTER INSTALLATION. 
<br />PIPELINE CROSSING INFORMATION 
<br />AT WATER MAIN CROSSINGS IN CONFLICT WITH OTHER FACILITIES: 
<br />WHEN THE WATER MAIN IS IN CONFLICT WITH EX. FACILITIES OR PROPOSED FACILITIES THAT REQUIRE MORE 
<br />THAN A 2 FOOT ADJUSTMENT FROM THE NOMINAL 4 FEET OF COVER, A FABRICATED STEEL CEMENT MORTAR 
<br />LINED AND CEMENT COATED OFFSET SHALL BE INSTALLED AT THE CROSSING PER CWS CO. STANDARDS. 
<br />*DESIGNATES CL&C OFFSET REQUIRED 
<br />PER CWS REPRESENTATIVE DIRECTION, FOR UNANTICIPATED CONFLICTS FOUND DURING CONSTRUCTION THAT 
<br />REQUIRE ADJUSTMENT OF NEW MAIN FROM THE NOMINAL 4 FEET OF COVER, A FIELD BUILT VERTICAL OFFSET 
<br />MAY BE CONSTRUCTED. SEE REVERSE KICKER DETAIL IF FIELD CONSTRUCTING VERTICAL OFFSETS AROUND 
<br />CROSSINGS. �\ 
<br />\ ,( INDICATES A SANITARY SEWER (SS) OR STORM DRAIN (SD) CROSSING. 
<br />PIPELINE CROSSINGS �SHALL BE INSTALLED OVER SS AND SD CROSSINGS PER GENERAL NOTE 10. PIPELINE 
<br />SHALL HAVE MINIMUM 2.5' COVER AND MINIMUM 1' VERTICAL SEPARATION BETWEEN NEW PIPELINE AND SS 
<br />OR SO CROSSINGS. THE ANGLE OF CROSSING SHALL BE FROM 45' TO 90'. ANY CROSSINGS NOT ABLE TO 
<br />BE INSTALLED PER CCR TITLE 22 "WATER MAIN SEPARATION" REQUIREMENTS SHALL BE INSTALLED PER STATE 
<br />APPROVED VARIANCE REQUEST. 
<br />GAS 
<br />_^om 
<br />ss 
<br />SD 
<br />ABANDON 
<br />CENTER LINE 
<br />EASEMENT 
<br />EXISTING WATER 
<br />GAS 
<br />INTERIOR LOT LINES 
<br />OIL 
<br />PROPERTY LINE 
<br />PROPOSED WATER 
<br />RIGHT-OF-WAY (RAV) 
<br />SANITARY SEWER 
<br />STORM DRAIN 
<br />STRUCTURE 
<br />ASPHALT 
<br />CONCRETE PAVEMENT 
<br />DIRT/EARTH 
<br />LANDSCAPE 
<br />X) 
<br />BLOWOFF (PROPOSED) 
<br />x• 
<br />BLOWOFF (EXISTING) 
<br />8 
<br />BUTTERFLY VALVE 
<br />E 
<br />CAP & PLUG 
<br />CB 
<br />CATCH BASIN 
<br />RT 
<br />CHECK VALVE 
<br />�y 
<br />ELBOW, 45° 
<br />7 
<br />ELBOW, 90° 
<br />CPLG 
<br />FIRE HYDRANT (PROPOSED) 
<br />& 
<br />FIRE HYDRANT (EXISTING) 
<br />## 
<br />FLEX CPLG. (OR AS NOTED) 
<br />O 
<br />GATE VALVE (PROPOSED) 
<br />• 
<br />GATE VALVE (EXISTING) 
<br />D 
<br />REDUCER (PROPOSED) 
<br />No 
<br />REDUCER (EXISTING) 
<br />ss 
<br />SEWER MANHOLE 
<br />so 
<br />STORM DRAIN MANHOLE 
<br />FI 
<br />TEE 
<br />wu 0 
<br />WATER METER 
<br />ABBREVIATIONS: 
<br />ABAND. 
<br />= ABANDONED 
<br />APN 
<br />= ASSESSORS PARCEL NUMBER 
<br />AB 
<br />= AGGREGATE BASE 
<br />AC 
<br />= ASBESTOS CEMENT PIPE 
<br />CB 
<br />= CATCH BASIN 
<br />CI 
<br />= CAST IRON 
<br />CL&C 
<br />= CEMENT LINED & COATED 
<br />CONC. 
<br />= CONCRETE 
<br />CPLG 
<br />= COUPLING 
<br />CU. YD. 
<br />= CUBIC YARD(S) 
<br />CWS 
<br />= CALIFORNIA WATER SERVICE 
<br />DEG 
<br />= DEGREES 
<br />DI 
<br />= DUCTILE IRON 
<br />EL. 
<br />= ELEVATION 
<br />ELEC 
<br />= ELECTRICAL 
<br />ELL 
<br />= ELBOW JOINT 
<br />EOP 
<br />= EDGE OF PAVEMENT 
<br />EP 
<br />= ELECTRICAL PANEL 
<br />EX./(E) 
<br />= EXISTING 
<br />FBE 
<br />= FLANGE BOTH ENDS 
<br />FH 
<br />= FIRE HYDRANT 
<br />RIP 
<br />= FEMALE IRON PIPE 
<br />FL 
<br />= FLOW LINE 
<br />FOE 
<br />= FLANGE ON END 
<br />FPT 
<br />= FEMALE PIPE THREAD 
<br />FS 
<br />= FINISH SURFACE 
<br />GB 
<br />= GROUND BOX 
<br />GPM 
<br />= GALLONS PER MINUTE 
<br />HORIZ. 
<br />= HORIZONTAL 
<br />HP 
<br />= HORSEPOWER 
<br />IBC 
<br />= INTERNATIONAL BUILDING CODE 
<br />INV 
<br />= PIPE INVERT 
<br />L 
<br />= LENGTH 
<br />MH 
<br />= MANHOLE 
<br />MIP 
<br />= MALE IRON PIPE 
<br />MJ 
<br />= MECHANICAL JOINT 
<br />MPT 
<br />= MALE PIPE THREAD 
<br />(N) = NEW/PROPOSED 
<br />SERVICE CONNECTIONS 
<br />BILL OF 
<br />MATERIALS 
<br />±131 
<br />SERVICES 
<br />NEW MAIN 
<br />CONNECTIONS 
<br />= NOT TO SCALE 
<br />QTY 
<br />OHE 
<br />DESCRIPTION 
<br />OIL 
<br />4" MAIN 
<br />±15' 
<br />4" DUCTILE IRON PIPE 
<br />PBE 
<br />±20' 
<br />TRACER WIRE #12 AWG 
<br />INSULATION 
<br />SOLID COPPER w/ 45 MILS 
<br />HMWPE 
<br />±20' 
<br />LINEGUARD TAPE 
<br />= PLAIN ON END 
<br />Q 
<br />±25' 
<br />POLYWRAP TUBING FOR 
<br />4" DI PIPE 
<br />PRESSURE RELIEF VALVE 
<br />8" MAIN 
<br />PVC 
<br />±5,355' 
<br />8" DUCTILE IRON PIPE 
<br />RE 
<br />= REDUCER 
<br />±5,895' 
<br />TRACER WIRE #12 AWG 
<br />INSULATION 
<br />SOLID COPPER w/ 45 MILS 
<br />HMWPE 
<br />±5,895' 
<br />LINEGUARD TAPE 
<br />W 
<br />SD 
<br />±8,035' 
<br />POLYWRAP TUBING FOR 
<br />8" DI PIPE 
<br />= STORM DRAIN MANHOLE 
<br />14 
<br />8" GATE VALVE, PO 
<br />= SLIP ON WELD FLANGE 
<br />14 
<br />8" VALVE CASING AND 
<br />COVER ASSEMBLY 
<br />SSMH 
<br />6 
<br />8" 22.5' ELBOW, PO 
<br />STD BLK 
<br />= STANDARD STEEL PIPE 
<br />6 
<br />8" 45' ELBOW, PO 
<br />= STEEL 
<br />1 
<br />8" 90' ELBOW, PO 
<br />SQ. FT. 
<br />4 
<br />8" TEE, PO 
<br />TDH 
<br />= TOTAL DYNAMIC HEAD 
<br />6 
<br />TIE-IN PER DETAILS: B, 
<br />C, D, F, G. J 
<br />MAP MON❑ 
<br />MAP 
<br />TON 
<br />12" MAIN 
<br />±60' 
<br />12" DUCTILE IRON PIPE 
<br />PUT 
<br />MET ❑ 
<br />UMC 
<br />±70' 
<br />TRACER WIRE #12 AWG 
<br />INSULATION 
<br />SOLID COPPER w/ 45 MILS 
<br />HMWPE 
<br />±70' 
<br />LINEGUARD TAPE 
<br />= VICTAULIC BOTH ENDS 
<br />±90' 
<br />POLYWRAP TUBING FOR 
<br />12" DI PIPE 
<br />VOE 
<br />4 
<br />TIE-IN PER DETAILS: A, 
<br />E, H, 1 
<br />= WIDTH 
<br />2 
<br />12" GATE VALVE, PO 
<br />= WATER VALVE 
<br />PLAT SHEET NO.: 
<br />2 
<br />12" VALVE CASING AND 
<br />COVER ASSEMBLY 
<br />VOL 
<br />1 
<br />12" 90' ELBOW, PO 
<br />ZN 
<br />= ZONE 
<br />1 
<br />12" 45' ELBOW, PO 
<br />SCALE: 
<br />1 
<br />12" TEE, PO 
<br />AS REQUIRED 
<br />METAL GUARD #301 - 
<br />(FLEX. CPLG., FLGS... ) 
<br />1 GAL. PER 2 FITTINGS OF BARE STEEL 
<br />AS REQUIRED 
<br />RES -BIT WRAP (100' ROLLS) - 1 RL. F/EVERY GAL. 
<br />GUARD #301 
<br />OF METAL 
<br />AS REQUIRED 
<br />#80 SACKS/CONCRETE 
<br />THRUST BLOCKS 
<br />SERVICE CONNECTIONS 
<br />QTY 
<br />DESCRIPTION 
<br />±131 
<br />SERVICES 
<br />ALL UNDERGROUND UTILITIES OR STRUCTURES REPORTED BY THE OWNER OR OTHERS AND THOSE SHOWN ON 
<br />THE RECORDS EXAMINED ARE INDICATED WITH THEIR APPROXIMATE LOCATION AND EXTENT. THE OWNER BY 
<br />ACCEPTING THESE PLANS OR PROCEEDING WITH IMPROVEMENTS PURSUANT THERETO AGREES TO ASSUME 
<br />LIABILITY AND TO HOLD UNDERSIGNED HARMLESS FOR ANY DAMAGES RESULTING FROM THE EXISTENCE OF 
<br />UNDERGROUND UTILITIES OR STRUCTURES NOT REPORTED TO THE UNDERSIGNED; NOT INDICATED ON THE 
<br />PUBLIC RECORDS EXAMINED; LOCATED AT VARIANCE WITH THAT REPORTED OR SHOWN ON RECORDS 
<br />EXAMINED. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE 
<br />UTILITIES OR STRUCTURES SHOWN AND ANY OTHER UTILITIES OR STRUCTURES FOUND AT THE SITE. IT 
<br />SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE OWNERS OF THE UTILITIES OR STRUCTURES 
<br />CONCERNED BEFORE STARTING WORK. CONTRACTOR SHALL CALL UNDERGROUND SERVICE ALERT AT (800) 
<br />642-2444 AT LEAST 48 HOURS PRIOR TO THE COMMENCEMENT OF WORK. 
<br />THE UNDERGROUND UTILITIES SHOWN HEREON ARE BASED ON INFORMATION PROVIDED BY THE VARIOUS 
<br />UTILITY COMPANIES AND OR ABOVE GROUND MARKERS, AND THESE LOCATIONS SHOULD BE CONSIDERED 
<br />APPROXIMATE. NO REPRESENTATION IS HEREBY GIVEN OR IMPLIED THAT ALL UNDERGROUND UTILITIES ARE 
<br />SHOWN ON THIS MAP. 
<br />ENGINEERING 
<br />NEC 
<br />= NATIONAL ELECTRIC CODE 
<br />DESCRIPTION 
<br />NET 
<br />= NATIONAL PIPE THREAD 
<br />N.T.S. 
<br />= NOT TO SCALE 
<br />OHE 
<br />= OVERHEAD ELECTRICAL 
<br />OIL 
<br />= OIL LINES 
<br />PBC 
<br />= PORTABLE BOOSTER CONNECTION 
<br />PBE 
<br />= PLAIN BOTH ENDS 
<br />' 
<br />PO 
<br />= PUSH -ON 
<br />' 
<br />POE 
<br />= PLAIN ON END 
<br />Q 
<br />PRV 
<br />= PRESSURE REDUCING VALVE/ 
<br />a 
<br />PRESSURE RELIEF VALVE 
<br />DEPARTMENT 
<br />PVC 
<br />= POLYVINYL CHLORIDE 
<br />� 
<br />RE 
<br />= REDUCER 
<br />RCP 
<br />= REINFORCED CONCRETE PIPE 
<br />REVISIONS: 
<br />ROW 
<br />= RIGHT OF WAY 
<br />W 
<br />SD 
<br />= STORM DRAIN 
<br />SDMH 
<br />= STORM DRAIN MANHOLE 
<br />SOW 
<br />= SLIP ON WELD FLANGE 
<br />SS 
<br />= SANITARY SEWER 
<br />SSMH 
<br />= SANITARY SEWER MANHOLE 
<br />STD BLK 
<br />= STANDARD STEEL PIPE 
<br />STL 
<br />= STEEL 
<br />S.U.M. 
<br />= SUBSURFACE UTILITY MAPPING 
<br />SQ. FT. 
<br />= SQUARE FEET 
<br />TDH 
<br />= TOTAL DYNAMIC HEAD 
<br />DATE: DSOT• 
<br />TOC 
<br />= TOP OF CURB 
<br />MAP MON❑ 
<br />MAP 
<br />TON 
<br />= TOP OF NUT 
<br />TYP 
<br />= TYPICAL 
<br />PUT 
<br />MET ❑ 
<br />UMC 
<br />= UNIFORM MECHANICAL CODE 
<br />UPC 
<br />= UNIFORM PLUMBING CODE 
<br />scSn�renc ❑ 
<br />VBE 
<br />= VICTAULIC BOTH ENDS 
<br />VCP 
<br />= VITRIFIED CLAY PIPE 
<br />STATION ❑ 
<br />SCNSNAnc 
<br />VOE 
<br />= VICTAULIC ON END 
<br />W 
<br />= WIDTH 
<br />WV 
<br />= WATER VALVE 
<br />PLAT SHEET NO.: 
<br />VERT. 
<br />= VERTICAL 
<br />VOL 
<br />= VOLUME 
<br />STK 29-25, 29-26 
<br />ZN 
<br />= ZONE 
<br />SCALE: 
<br />FIRE HYDRANTS 
<br />QTY 
<br />DESCRIPTION 
<br />7 
<br />6" FIRE HYDRANTS 
<br />NOTES 
<br />1. ALL BELOW GROUND FITTINGS REQUIRE A THRUST BLOCK (TO BE 
<br />CONSTRUCTED PER CWS STANDARD DRAWING CW -435-R4). 
<br />2. ALL PIPING, FITTINGS, VALVES, AND OTHER MATERIALS SHALL COMPLY WITH 
<br />SPECIFICATIONS ESTABLISHED IN CWS STANDARD DRAWING CW -863-R6. 
<br />3. TIE-IN ALL EXISTING (LONG/SHORT) SERVICE TO PROPOSED CWS AFTER 
<br />INSTALLATION. 
<br />4. IF FIELD CONDITIONS OR FIRE PROTECTION AGENCY REQUIRE AN 
<br />ALTERNATIVE FIRE HYDRANT INSTALLATION, THE OUTLET TEE AND GATE 
<br />VALVE MAY BE REPLACED WITH: 
<br />1 - 6 INCH OUTLET TEE POxFLG, DI 
<br />1 - 6 INCH GATE VALVE FLGxPO 
<br />1 - 6 INCH GASKET FOR FLANGED JOINT 
<br />1 - SET J" x 31" #304 SS BOLTS & NUTS, AND GASKETS 
<br />5. FIRE HYDRANT: 
<br />RESIDENTIAL: CLOW 950 2 J" & 4 }" 
<br />COMMERCIAL/INDUSTRIAL: CLOW 960 (2) 2 J" & 4" 
<br />(THE FIRE CHIEF WILL MAKE THE FINAL CHOICE OF FIRE HYDRANT HEAD 
<br />WITH CAL WATER APPROVAL 
<br />6. A BREAK -OFF CHECK VALVE FOR THE HYDRANT MAY BE REQUIRED IF 
<br />SPECIFIED BY DISTRICT PERSONNEL. USE CLOW MODEL LB400 OR 
<br />APPROVED EQUAL. 
<br />7. THE CENTER LINE OF THE LOWEST OUTLET SHALL BE 18" ABOVE FINISHED 
<br />GRADE 
<br />Know what's below. 
<br />Call before you dig. 
<br />N/A 
<br />DRAWN BY: 
<br />THU PHAM 
<br />DESIGNED BY: 
<br />L. VILLANUEVA 
<br />TECH REVIEW: DATE 
<br />CHECKED BY: DATE: 
<br />-� 
<br />11/28/22 
<br />APPROVED BY: DATE: 
<br />Q6c*_� 11/28/22 
<br />Q�'OFESS/ON 
<br />OpY RO{y�lF 
<br />ED- No. C74078 m 
<br />ce- EXP. 06-30-23 
<br />`ray clm\_ 
<br />�F OF CA 
<br />W 
<br />DISTRICT: 
<br />� 
<br />cc 
<br />E 
<br />U 
<br />C) 
<br />Q 
<br />a 
<br />Q 
<br />� 
<br />w 
<br />a 
<br />� 
<br />1-� 
<br />a 
<br />W 
<br />� 
<br />W 
<br />0 
<br />a � 
<br />W 
<br />E- 
<br />F 
<br />E - 
<br />DISTRICT: 
<br />STOCKTON 
<br />DATE: 
<br />11/28/2022 
<br />PROJECT ID.: 
<br />00124704 
<br />DRAWING NO.: 
<br />STK-9237 R1 
<br />SHT 2 OF 11 
<br /> |