Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2023_PS-2301501 thru PS-2302000_ - PS-2301697
PublicWorks
>
- PUBLIC SERVICES
>
PERMITS & DEVELOPMENT
>
Encroachment(EP)/Driveway(DW) Permits
>
2023
>
PS-2301501 thru PS-2302000
>
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2023_PS-2301501 thru PS-2302000_ - PS-2301697
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/16/2023 10:41:27 AM
Creation date
6/16/2023 10:38:40 AM
Metadata
Fields
Template:
Permits_Development
DocName
PS-2301697
Category07
Encroachment(EP)/Driveway(DW) Permits
Year2
2023
Notes2
Lincoln Village West
Address
3011 Triad Pl., Livermore,CA 94551
Application
Comcast
Type
TCP
Supplemental fields
Cross Ref
PWP7110005
Type (2)
Encroachment Permit (EP)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
LINETYPES <br />GENERAL NOTES: <br />FIBER PLACEMENT NOTES: <br />. . <br />. . . . . . . . . . . . . PROPOSED UG BORE ROUTE <br />.............. PROPOSED BORE AND ROUTE <br />1. <br />ALL VAULTS/ HANDHOLES TO BE EQUIPPED WITH SECURITY LIDS WITH LOCKING BOLTS. <br />1. <br />CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL UTILITIES 48 <br />CATV <br />NEW AERIAL ROUTE <br />HOURS PRIOR TO CONSTRUCTION ACTIVITY <br />Tv <br />OVERPULL/EXISTING COMCAST CONDUIT <br />2. <br />GROUND RESTORATION/RIGHT-OF-WAY SHALL BE RESTORED TO ORIGINAL OR BETTER CONDITION. <br />SEE LOCAL DIRECTORY FOR CONTACT TELEPHONE NUMBER OF <br />LOCAL CALL BEFORE YOU DIG AGENCY. <br />T <br />EXISTING TELEPHONE SYSTEM <br />3. <br />ALL 90 DEGREE BENDS IN CONDUIT CONSTRUCTION WILL BEA MINIMUM OF 36'' RADIUS UNLESS <br />SPECIFIED OTHERWISE. <br />2. <br />CONTRACTOR SHALL RECORD SEQUENCE# OF FIBER CABLE AT <br />E <br />EXISTING ELECTRICAL SYSTEM <br />EVERY WORK POLE, MANHOLE, FIBRE STORAGE LOOP <br />G <br />EXISTING GAS SYSTEM <br />4. <br />BURIED FIBER OPTIC WARNING SIGNS SHALL BE PLACED AT EACH SIDE OFALL ROAD CROSSINGS, <br />AND TAIL LOCATION. CONTRACTOR TO PROVIDE PROJECT <br />AT CULVERTS, DITCHES AND IN A STRAIGHT LINE OF SIGHT SPACING OFAPPROXIMATELY 500 FEET. <br />MANAGER WITH SEQUENCE NUMBERSAT PROJECT <br />Tv <br />EXISTING TV SYSTEM <br />COMPLETION. <br />IRR <br />EXISTING IRRIGATION SYSTEM <br />5. <br />DEVIATIONS FROM THE ENGINEERED ROUTE REQUIRESA PROJECT MANAGER AND RIGHT-OF-WAY <br />OWNER OF CARETAKER APPROVAL PRIOR TO CONSTRUCTION. <br />3. <br />SLACK LOOP AND SNOWSHOE STORAGE LOCATIONS SHALL BE <br />JT <br />EXISTING JOINT BORE AND VAULT UPGRADE <br />DETERMINED ON CONSTRUCTION DRAWINGS, HOWEVER, <br />6. <br />WHERE PERMITS FROM STATE, COUNTY, CITY, RAILROAD OR GOVERNMENT AGENCIES ARE <br />REEL LENGTHS OF FIVE HUNDRED FEET (50(Y) OR LESS ON LARGE <br />ss <br />EXISTING SANITARY SEWER <br />REQUIRED, ALL WORK PERFORMED WILL COMPLY WITH THESE AGENCIES STANDARD <br />COUNT FIBER OR THREE HUNDRED (300') OR LESS <br />SD <br />EXISTING STORM DRAIN <br />SPECIFICATIONS. <br />ON SMALL COUNT FIBER ARE DIFFICULT TO USE AND SHOULD BE <br />PLACEDAS FSUS, NOTCUTAND RETURNED. <br />w <br />EXISTING WATER LINE <br />7. <br />THE PROJECT MANAGER WILL NOTIFY BUILDING MANAGEMENT WHEN WORK WILL BEGIN ON <br />x • x <br />EXISTING FENCELINE <br />BUILDING. CONTRACTOR TO COORDINATE ROOMACCESSAND WORKSTARTAND STOP TIMES <br />4. <br />FIBEROPTIC IDENTIFICATION TAGS SHALL BE PLACEDAT EVERY <br />WITH BUILDING MANAGEMENT. <br />WORK POLE, MANHOLE, FIBER, STORAGE LOOPS, SPLICE <br />ROADWAY CENTER LINE <br />CASES AND WHERE INDICATED BY PROJECT MANAGER. TAGS <br />R/W <br />PROPERTY LINE <br />8. <br />THE PROJECT MANAGER IS TO BE NOTIFIED BY THE CONTRACTOR 24 HOURS PRIOR TO <br />NEED TO BE PLACED SO AS TO BE READ FROM THE GROUND. <br />PG&E <br />EXISTING PG&E LINE <br />CONSTRUCTION. SEE COMPANY CONTACT LIST FOR CONTACT NAME(s) AND TELEPHONE <br />NUMBER(s). <br />5. <br />CABLE LUBRICATION SHALL BE USED TO REDUCE PULLING <br />ABBREVIATIONS <br />TENSION. LUBRICANTS MUST NOT CONTAIN ANY PETROLEUM <br />9. <br />THE PROJECT MANAGER WILL RESERVE THE RIGHT TO INSPECTATANY TIME THE WORK BEING <br />PRODUCTS. <br />COMCAST COMCASTpL <br />CL CENTERLINE <br />PROPERTY LINE <br />PERFORMED BY THE CONTRACTOR. IF PROJECT MANAGER DETERMINES THAT THE WORK IS NOT <br />PUE <br />PUBLIC UTILITY EASEMENT <br />BEING PERFORMED TO MINIMUM QUALITY STANDARDS, THEN THE CONTRACTOR SHALL PROVIDE <br />6. <br />A 100 FOOT FIBER COIL MUST REMAIN IN ALLVAULTS UNLESS <br />(E) EXISTING R/W <br />RIGHT OF WAY <br />REWORKAT HIS OWN COST. <br />OTHERWISE NOTED. <br />(N) NEW BOW <br />BACK OF WALK <br />FOC FACE OF CURB SD <br />EXISTING STORM DRAIN <br />10. <br />ANY CHANGE IN PROJECT SCOPE, INCLUDING BUT NOT LIMITED TO, CONDUIT LENGTH, CONDUIT <br />7. <br />ALL BURIED INFRASTRUCTURE MUST BE ACCOMPANIED WITH <br />MIN MINIMUM SS <br />EXISTING SANITARY SEWER <br />PATH, AERIAL PATH ETC. MUST BE APPROVED BY THE PROJECT MANAGER. <br />WARNING TAPE AND A TRACER WIRE, AT RISER POLES THE <br />MAX MAXIMUM T <br />EXISTING TELEPHONE <br />LOCATE WIRE SHALL BE ACCESSIBLE AT THE BASE OF THE RISER. <br />D/W DRIVEWAY W <br />EXISTING WATER <br />11. <br />ALL CORING/CONSTRUCTION THAT WILLCAUSE NOISE AND/OR VIBRATION SHALL BE DONE WITHIN <br />O/S OFFSET R/R <br />REMOVAL/REPAIR <br />ALLOWED(9AM-3PM) BUSINESS HOURS. <br />B. <br />ALL RISERS WILL BE CAPPED AT ALL TIMES. <br />12. <br />ANYAND ALL UNDERGROUND UTILITIES ENCOUNTERED ARE THE RESPONSIBILITY OF THE <br />9. <br />ALL FIBER SHALL BE MARKED AS TO DIRECTION IN EACH VAULT. <br />SYMBOLS <br />CONTRACTOR TO LOCATE, PROTECT. AND REPAIR, IF DAMAGED. <br />RED-NORTH, GREEN-SOUTH, YELLOW-EAST, AND <br />BLUE-WEST, DO NOT TAPE FIBER CABLES TOGETHER IN RISER. <br />NEW COMCAST POWER SUPPLY <br />TRANSFORMER <br />13. <br />ALL FOOTAGESARE BASED ON FIELD GATHERED MEASUREMENTS, AS SUCH SOME VARIANCE <br />® <br />NEW COMCAST LOW PROFILE <br />SHOULD BE ANTICIPATED. ADJUSTAS NEEDED. <br />STREET LIGHT <br />m 8 <br />POWER SUPPLY W/ METER <br />14. <br />ALL BURIED CONDUIT/CABLE WILL BE PLACED AT 36" MINIMUM COVER. SITE HAS POTENTIAL FOR <br />TRAFFIC SIGNAL COMBINATION <br />ROCK THAT WOULD PREVENT THE ABILITY TO PROVIDE THE MINIMUM COVER, IN CASES WHERE <br />DISCLAIMER: <br />0 <br />NEW COMCAST VAULT <br />THE MINIMUM COVER CAN NOT BE ACHIEVED, THE CONDUIT SHALL BE PLACED IN A SCH 40 EMT SLEEVE <br />OR APPROVED EQUIVALENT. <br />O FIRE HYDRANT <br />1. <br />IT IS THE RESPONSIBILITY OF THE CONSTRUCTION CONSTRUCTOR <br />m <br />NEW COMCAST PEDESTAL <br />15, <br />WATER, SEWER, STORM SEWERAND EASEMENT LOCATIONSARE BASED OFF OF CITY MAPS, <br />TO VERIFYALL RIGHT OF WAY BEFORE CONSTRUCTION IS TO <br />® <br />MONUMENT <br />NOT FIELD VERIFIED. <br />BEGIN. NO UNDERGROUND INSTALLATION REPRESENTED WITHIN <br />BORE AND VAULT UPGRADE PIT <br />THESE PLAN SHEETS IS PROPOSED OUTSIDE OF THE RIGHT OF <br />® CATCH BASIN <br />16. <br />BORING OFAC PAVING IS REQUIREDATALL LOCATIONSAS INDICATED ON PLANS. <br />WAY. <br />NEW RISER ATTACHED TO POLE <br />17. <br />AT NO TIMES SHALL CURBS, GUTTERS OR HANDICAP BE DISTURBED. <br />2. <br />THE UNDERGROUND ROUTE DEPICTED IS PRELIMINARY AND <br />STORM DRAIN MANHOLE <br />WILL/MAY VARYONCE UTILITIES HAVE <br />® <br />EXISTING POLE <br />18. <br />DOOR HANGERSARE TO BE PLACED A MINIMUM OF 52 HOURS PRIOR TO START OF CONSTRUCTION. <br />BEEN FIELD LOCATED. <br />Ow WATER MANHOLE <br />EXISTING COMCAST VAULT <br />19. <br />PRIOR TO START OF CONSTRUCTION, CONTRACTOR SHALL PLACE MESSAGE BOARDS STATING <br />3. <br />ANCHORING FOR THE AERIAL CONSTRUCTION IS TYPICALLY <br />SANITARY SEWER MANHOLE <br />LANE CLOSURES, AND DELAYS A WEEK IN ADVANCE, LOCATION OF THE MESSAGE BOARD SHALL BE <br />DETERMINED DURING CONSTRUCTION AND IS COLLECTED IN THE <br />® <br />EXISTING COMCAST PEDESTAL <br />COORDINATE WITH THE CITY INSPECTORAT THE PRE-CONSTRUCTION MEETING. <br />AS-BUILT PHASE. <br />O <br />EXISTING IRRIGATION VAULT <br />© SEWER CLEAN OUT <br />20, <br />LANE CLOSURES CANNOT EXCEED MORE THAN 300 FT. ATA TIME. FOR SAFETY PURPOSES THERE <br />OE ELECTRIC MANHOLE <br />SHALL BE ONLY ONE CLOSURE ATA TIME ALONG W BENJAMIN HOLT DR & HARRISBURG PL. MORE <br />D <br />EXISTING UTILITY VAULT/PEDESTAL <br />FLAGGERS WILL BE NECESSARYTO HELP VEHICLESAND PEDESTRIANS IN THE WORKZONES DURING <br />THE LANE CLOSURES. <br />© UNIDENTIFIED MANHOLE <br />D<— <br />GAS/WATER VALVE <br />® WATER METER <br />TREE/BUSHES <br />O <br />POTHOLE <br />GAS METER <br />THIS IS AN <br />COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIAL <br />did. c"ynd RQ <br />Conroy-2169541 <br />REV DESCRIPTION <br />DATE <br />m <br />IMPORTANT NOTICE <br />SEFNCO <br />COmmuwCwnoxS <br />�Plann ENG <br />o--h <br />W.jn.ng@9 <br />DESIGN: N.PE <br />Section # 4216/4217 of the Government Code requires a <br />w pb ^^ne e`ioan <br />DRAWN BY: WS.PE <br />0 ISSUE FOR PERMIT <br />04/08/2023 <br />Dig Alert Identification Number to be issued before a <br />"PErmit to Excavate" will be valid For your Dig Alert I.D. <br />PROJ # : JB1386858 <br />DRAWN BY: SB.KL <br />CALL TOLL FREE <br />CONSTRUCTION TYPE: SPLICING <br />DRAWN BY: <br />48 HOURS BEFORE YOU DIG <br />UNDERGROUND SERVICE ALERT <br />SYSTEM: SJ COUNTY <br />APPROVED: <br />1-800-227-2600 <br />NODE: <br />SHEEF: <br />2 OF 28 <br />