Laserfiche WebLink
LINETYPES <br />GENERAL NOTES: <br />FIBER PLACEMENT NOTES: <br />. . <br />. . . . . . . . . . . <br />. . PROPOSED BORE ROUTE <br />. . <br />. . . . . . . . . . .. <br />PROPOSED TRENCH ROUTE <br />1. <br />ALL VAULTS/HANDHOLES TO BE EQUIPPED WITH SECURITY LIDS WITH LOCKING BOLTS. <br />1. <br />CONTRACTORISRESPONSIBLE FOR LOCATING ALL UTILITIES 48 <br />CAN <br />NEWAERIALROUTE <br />HOURS PRIOR TO CONSTRUCTION ACTIVITY <br />ry <br />OVERPULL/EXISTING COMCAST CONDUIT <br />2. <br />GROUND RESTORATION/RIGHT-OF-WAY SHALL BE RESTORED TO ORIGINAL OR BETTER CONDITION. <br />SEE LOCAL DIRECTORY FOR CONTACT TELEPHONE NUMBER OF <br />T <br />EXISTING TELEPHONE SYSTEM <br />LOCAL CALL BEFORE YOU DIG AGENCY. <br />3. <br />ALL 90 DEGREE BENDS IN CONDUIT CONSTRUCTION WILL BE A MINIMUM OF 36'RADIUS UNLESS <br />E <br />EXISTING ELECTRICAL SYSTEM <br />SPECIFIED OTHERWISE. <br />2. <br />CONTRACTOR SHALL RECORD SEQUENCE# OF FIBER CABLE AT <br />G <br />EXISTING GAS SYSTEM <br />EVERY WORK POLE, MANHOLE, FIBRE STORAGE LOOP <br />4. <br />BURIED FIBER OPTIC WARNING SIGNS SHALL BE PLACED AT EACH SIDE OF ALL ROAD CROSSINGS, <br />AND TAIL LOCATION. CONTRACTOR TO PROVIDE PROJECT <br />Tv <br />EXISTING TV SYSTEM <br />AT CULVERTS, DITCHES AND IN A STRAIGHT LINE OF SIGHT SPACING OF APPROXIMATELY 500 FEET. <br />MANAGER WITH SEQUENCE NUMBERS AT PROJECT <br />IRR <br />EXISTING IRRIGATION SYSTEM <br />COMPLETION. <br />5. <br />DEVIATIONS FROM TH E ENGINEERED ROUTE REQUIRES A PROJECT MANAGER AND RIGHT-OF-WAY <br />JT <br />EXISTING JOINT TRENCH <br />OWNER OF CARETAKER APPROVAL PRIOR TO CONSTRUCTION. <br />3. <br />SLACK LOOP AND SNOWSHOE STORAGE LOCATIONS SHALL BE <br />DETERMINED ON CONSTRUCTION DRAWINGS, HOWEVER, <br />55 <br />EXISTING SANITARY SEWER <br />6. <br />WHERE PERMITS FROM STATE, COUNTY, CITY, RAILROAD OR GOVERNMENT AGENCIES ARE <br />REEL LENGTHS OF FIVE HUNDRED FEET (500') OR LESS ON LARGE <br />SD <br />EXISTING STORM DRAIN <br />REQUIRED, ALL WORK PERFORMED WILL COMPLY WITH THESE AGENCIES STANDARD <br />COUNT FIBER OR THREE HUNDRED (300') OR LESS <br />SPECIFICATIONS. <br />ON SMALL COUNT FIBER ARE DIFFICULT TO USE AND SHOULD BE <br />w <br />EXISTING WATER LINE <br />PLACED AS FSL'S, NOT CUT AND RETURNED. <br />x x x <br />EXISTING FENCELINE <br />7. <br />THE PROJECT MANAGER WILL NOTIFY BUILDING MANAGEMENT WHEN WORK WILLBEGIN ON <br />BUILDING. CONTRACTOR TO COORDINATE ROOM ACCESSAND WORKSTARTAND STOPTIMES <br />4. <br />FIBER OPTIC IDENTIFICATION TAGSSHALLBE PLACEDAT EVERY <br />ROADWAY CENTER LINE <br />WITH BUILDING MANAGEMENT. <br />WORK POLE, MANHOLE, FIBER, STORAGE LOOPS, SPLICE <br />PL <br />PROPERTY LINE <br />CASES AND WHERE INDICATED BY PROJECT MANAGER. TAGS <br />8. <br />THE PROJECT MANAGER IS TO BE NOTIFIED BY THE CONTRACTOR 24 HOURS PRIOR TO <br />NEED TO BE PLACED SO AS TO BE READ FROM THE GROUND. <br />PG&E <br />PG&E LINE <br />CONSTRUCTION. SEE COMPANY CONTACT LIST FOR CONTACT NAME(s) AND TELEPHONE <br />NUMBER(s). <br />5. <br />CABLE LUBRICATION SHALL BE USED TO REDUCE PULLING <br />comm <br />COMMUNICATION LINE <br />TENSION. LUBRICANTS MUST NOT CONTAIN ANY PETROLEUM <br />ABBREVIATIONS <br />9. <br />THE PROJECT MANAGER WILL RESERVE THE RIGHT TO INSPECTAT ANY TIME THE WORK BEING <br />PRODUCTS. <br />PERFORMED BY THE CONTRACTOR. IF PROJECT MANAGER DETERMINES THAT THE WORK IS NOT <br />COMCAST COMCAST <br />PL <br />PROPERTY LINE <br />BEING PERFORMED TO MINIMUM QUALITY STANDARDS, THEN THE CONTRACTOR SHALL PROVIDE <br />6. <br />A 100 FOOT FIBER COIL MUST REMAIN IN ALL VAULTS UNLESS <br />CL CENTER LINE <br />PUE <br />PUBLIC UTILITY EASEMENT <br />REWORK AT HIS OWN COST. <br />OTHERWISE NOTED. <br />(E) EXISTING <br />R/W <br />RIGHT OF WAY <br />(N) NEW <br />BOW <br />BACK OF WALK <br />10. <br />ANY CHANGE IN PROJECT SCOPE, INCLUDING BUT NOT LIMITED TO, CONDUIT LENGTH, CONDUIT <br />7. <br />ALL BURIED INFRASTRUCTURE MUST BE ACCOMPANIED WITH <br />FOC FACE OF CURB <br />SD <br />EXISTING STORM DRAIN <br />PATH, AERIAL PATH ETC. MUST BE APPROVED BY THE PROJECT MANAGER. <br />WARNING TAPE AND A TRACER WIRE, AT RISER POLES THE <br />MIN MINIMUM <br />SS <br />EXISTING SANITARY SEWER <br />LOCATE WIRE SHALL BE ACCESSIBLE AT THE BASE OF THE RISER. <br />MAX MAXIMUM <br />T <br />EXISTING TELEPHONE <br />11. <br />ALL CORING/CONSTRUCTION THAT WILLCAUSE NOISE AND/OR VIBRATION SHALL BE DONE WITHIN <br />D/W DRIVEWAY <br />W <br />EXISTING WATER <br />ALLOWED (9AM-3PM) BUSINESS HOURS. <br />8. <br />ALL RISERS WILL BE CAPPED AT ALL TIMES. <br />O/S OFFSET <br />R/R <br />REMOVAL/REPAIR <br />12. <br />ANY AND ALL UNDERGROUND UTILITIES ENCOUNTERED ARE THE RESPONSIBILITY OF THE <br />9. <br />ALL FIBER SHALL BE MARKED AS TO DIRECTION IN EACH VAULT. <br />SYMBOLS <br />CONTRACTOR TO LOCATE, PROTECT. AND REPAIR, IF DAMAGED. <br />RED -NORTH, GREEN -SOUTH, YELLOW -EAST, AND <br />BLUE -WEST, DO NOT TAPE FIBER CABLES TOGETHER IN RISER. <br />NEW COMCAST POWER SUPPLY <br />Q TRANSFORMER <br />13. <br />ALL FOOTAGES ARE BASED ON FIELD GATHERED MEASUREMENTS, AS SUCH SOME VARIANCE <br />® <br />NEW COMCAST LOW PROFILE <br />SHOULD BE ANTICIPATED. ADJUSTAS NEEDED. <br />me <br />POWER SUPPLY W/ METER <br />STREETLIGHT <br />14. <br />ALL BURIED CONDUIT/CABLE WILL BE PLACED AT 36" MINIMUM COVER. SITE HAS POTENTIAL FOR <br />ROCK THAT WOULD PREVENT THE ABILITY TO PROVIDE THE MINIMUM COVER, IN CASES WHERE <br />DISCLAIMER: <br />TRAFFIC SIGNAL COMBINATION <br />THE MINIMUM COVER CANNOT BE ACHIEVED, THE CONDUIT SHALL BE PLACED INA SCH 40 EMT SLEEVE <br />0 <br />NEWCOMCASTVAULT <br />OR APPROVED EQUIVALENT. <br />O FIRE HYDRANT <br />1. <br />IT IS THE RESPONSIBILITY OF THE CONSTRUCTION CONSTRUCTOR <br />X1 <br />NEW COMCAST PEDESTAL <br />15. <br />WATER, SEWER, STORM SEWERAND EASEMENT LOCATIONS ARE BASED OFF OF CITY MAPS, <br />TO VERIFYALL RIGHT OF WAY BEFORE CONSTRUCTION IS TO <br />O MONUMENT <br />NOT FIELD VERIFIED. <br />BEGIN. NO UNDERGROUND INSTALLATION REPRESENTED WITHIN <br />® <br />THESE PLAN SHEETS IS PROPOSED OUTSIDE OF THE RIGHT OF <br />BORE PIT <br />16. <br />BORING OFAC PAVING IS REQUIRED AT ALL LOCATIONS AS INDICATED ON PLANS. <br />WAY. <br />® CATCH BASIN <br />®a <br />NEW RISERATTACHED TO POLE <br />17. <br />AT NO TIMES SHALL CURBS, GUTTERS OR HANDICAP BE DISTURBED. <br />2. <br />THE UNDERGROUND ROUTE DEPICTED IS PRELIMINARYAND <br />STORM DRAIN MANHOLE <br />WILL/MAY VARY ONCE UTILITIES HAVE <br />® <br />EXISTING POLE <br />18. <br />DOOR HANGERSARE TO BE PLACED A MINIMUM OF 482 HOURS PRIOR TO START OF CONSTRUCTION. <br />BEEN FIELD LOCATED. <br />Ow WATER MANHOLE <br />EXISTING COMCAST VAULT <br />19, <br />PRIOR TO START OF CONSTRUCTION, CONTRACTOR SHALL PLACE MESSAGE BOARDS STATING <br />3. <br />ANCHORING FOR THE AERIAL CONSTRUCTION IS TYPICALLY <br />LANE CLOSURES, AND DELAYSA WEEK IN ADVANCE, LOCATION OF THE MESSAGE BOARD SHALL BE <br />DETERMINED DURING CONSTRUCTION AND IS COLLECTED IN THE <br />SANITARY SEWER MANHOLE <br />COORDINATE WITH THE CITY INSPECTORAT THE PRE -CONSTRUCTION MEETING. <br />AS -BUILT PHASE. <br />® <br />EXISTING COMCAST PEDESTAL <br />0 SEWER CLEAN OUT <br />20. <br />LANE CLOSURES CANNOT EXCEED MORE THAN 300 FT. ATA TIME. FOR SAFETY PURPOSES THERE <br />O <br />EXISTING IRRIGATION VAULT <br />SHALL BE ONLY ONE CLOSURE AT A TIME ALONG FLEMONSAVE& E MARIPOSA RD. MORE FLAGGERS <br />WILL BE <br />(D ELECTRIC MANHOLE <br />NECESSARYTO HELP VEHICLESAND PEDESTRIANS IN THE WORKZONES DURING THE LANE CLOSURES. <br />O <br />EXISTING UTILITY VAULT/PEDESTAL <br />® UNIDENTIFIED MANHOLE <br />>*- <br />GAS/WATER VALVE <br />® WATER METER <br />TREE/BUSHES <br />© GAS METER <br />THIS IS AN <br />COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIAL <br />IMPORTANT NOTICE <br />SEFNCO <br />4744 Moon Rd, <br />con eom,oq 4m <br />ENG <br />DESIGN: N.PE <br />REV DESCRIPTION <br />DATE <br />Section # 4216/4217 of the Government Code requires a <br />COmmuxICwnoxS <br />�Plann <br />o-®epl <br />splannnu@D <br />plan®ngmxomm <br />'E ¢xw.planneng.eom <br />DRAWN BY: SL/IB <br />0 ISSUE FOR PERMIT <br />04/13/2023 <br />Dig Alert Identification Number to be issued before a <br />"Permit to Excavate" will be valid For your Dig Alert I.D. <br />PROJ#: JB1313327 <br />DRAWN BY: AR/RZ <br />CALL TOLL FREE <br />CONSTRUCTION TYPE: SPLICING <br />APPROVED: <br />48 HOURS BEFORE YOU DIG <br />UNDERGROUND SERVICE ALERT <br />SYSTEM: SJ COUNTY <br />APPROVED: <br />1-800-227-2600 <br />NODE: <br />SHEET: <br />2 OF 48 <br />