My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2023_PS-2301501 thru PS-2302000_ - PS-2301878
PublicWorks
>
- PUBLIC SERVICES
>
PERMITS & DEVELOPMENT
>
Encroachment(EP)/Driveway(DW) Permits
>
2023
>
PS-2301501 thru PS-2302000
>
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2023_PS-2301501 thru PS-2302000_ - PS-2301878
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/29/2023 11:59:56 AM
Creation date
6/29/2023 11:57:26 AM
Metadata
Fields
Template:
Permits_Development
DocName
PS-2301878
Category07
Encroachment(EP)/Driveway(DW) Permits
Year2
2023
Notes2
W/S of Sanguinetti Ln. 120' N/O Cherokee Rd.
Address
1602 E. Lafayette St. Stockton,CA 95205
Application
California Water Service
Type
Bell Holes; Trenches
Supplemental fields
Cross Ref
PWP730077
Type (2)
Encroachment Permit (EP)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
NOTES: <br />1, 2" SERVICE SHALL BE INSTALLED FOR ALL 1-1/2" METERS. <br />2. A SADDLE SHALL BE USED FOR ALL 2" SERVICES. <br />3. RESPONSIBILITY FOR SERVICE MAINTENANCE BY CWS CO. ENDS AT <br />DOWNSTREAM METER COUPUNG (OR LEFF TO DISTRICTS DISCRETION). <br />4. ALL PIPE FITTINGS IN CONTACT WITH DRINKING WATER SHALL BE LEAD FREE <br />(< 0.25% LEAD) AND COMPLIANT TO NSF-61/SECTION B. <br />5. INSERT SRFFNERS SHALL BE USED ON ALL PE PIPE WITH COMPRESSION <br />CONNECTIONS. <br />OPTIONS: THESE OPTIONS MAY BE REQUIRED BY CWS CO <br />1. EXTEND CUSTOMER'S PIPING 112" BEYOND METER BOX WITH TWO 12" <br />NIPPLES & TWO 90' ELLS, BRASS (OR GALVANIZED IF PREFERRED BY CWS), <br />SEE NOTE 3. <br />2. INSTALL BALL VALVE DOWNSTREAM FROM METER WHEN CUSTOMER'S <br />PIPING IS UPHILL FROM METER OR CUSTOMER'S VALVE IS A GREAT <br />DISTANCE FROM METER. <br />3. INSTALL 2" HDPE, INSTEAD OF COPPER WHEN CWS REPRESENTATIVE <br />DETERMINES THAT CONDITIONS ARE UNFAVORABLE TO COPPER. REFER TO <br />THE LATEST REVISION OF DWG# CW -436. <br />4. WHEN REQUIRED BY CWS COMPANY. PLACE BRICKS ON TWO SIDES OF <br />METER BOX FOR SUPPORT (OR 2" x 4" PRESSURE TREATED LUMBER) <br />5. AT THE DIRECTIVE OF CWS REPRESENTATIVE, LEAD—FREE SOLDER JOINT <br />COPPER FITTINGS MAY BE USED IN LIEU OF COMP♦'IESSION FFr NGS FOR <br />PART 'G'. INSTALLATION OF A SOLDERED FITTINGS SHALL CONFORM TO THE <br />LATEST REVISION OF ASTM B828. ALL MATERIAL USED FOR SOLDERING <br />SHALL BE LEAD—FREE. <br />Hi I I Iti I I— <br />P ill—nIMII <br />\\� 1 <br />CUSTOMER'S <br />-'"'•:; //\�/ / PIPE <br />-•,\ \ \•\\\' N R (SEE OPTIONS <br />E Q 1 & 2) <br />2" SERVICE WITH 1-1/2" METER <br />TRACER 1 <br />SPLICE. <br />DWG. CW - <br />0 <br />A (PVC C-900 PIPE) <br />B (STEEL, DUCTILE, CAST OR <br />WROUGHT IRON PIPE) <br />C (AC PIPE) <br />CUSTOMER'S <br />PIPE <br />OPTIONS <br />NOTE: P- PACK JOINT: Q- QUICK JOINT <br />2" SERVICE WITH 2" METER <br />PART <br />LETTER <br />PART NAME <br />MUELLER <br />FORD <br />A.Y. McDONALD <br />CAMBRIDGE BRASS <br />SMITH-BLAIR <br />APAC <br />A <br />SERVICE SADDLE <br />H-13400 <br />S90 SERIES <br />3805 SERIES <br />800 SERIES <br />393 SERIES <br />----- <br />B <br />SERVICE SADDLE <br />DR2A <br />F202 SERIES <br />4825A <br />----- <br />313 SERIES <br />102 SERIES <br />C <br />SERVICE SADDLE <br />BR28 <br />2028 SERIES <br />3825 SERIES <br />810 SERIES <br />323 SERIES <br />----- <br />D <br />2" CORPORATION STOP - AWWA TAPER THREAD INLET X MIP <br />B -2996N <br />FBB00-7-NL OR F8400 -7 -NL <br />731288 <br />301NL-A7M7 <br />Wn <br />E <br />2" COPPER <br />TYPE K SOFF PER LATEST REVISION OF ASTM SPECIFICATION B88 <br />F <br />2" 90' ELL COUPLING - CTS X CTS OR IPS X IPS <br />P15526-N(P)/Hl5526-N(Q) <br />L44-77-NL(P)/L44-77-Q-NL(Q) OR <br />74761-22(P)/74761Q-2(0) OR <br />105NL-B7B7(P)/105NL-H7H7(Q) OR <br />_____ <br />_____ <br />L66-77-IDR7-NL <br />74761-33 <br />105NL-PE7PE7 <br />r <br />G <br />2" STRAIGHT COUPLING - CTS X CTS OR IPS X IPS <br />P15403-N(P)/H15403-N(Q) OR <br />C44-77-NL(P)/C44-77-Q-NL(Q) OR <br />74758 -22(P)/747580 -2(Q) OR <br />118NL-B787(P)/118NL-H7H7(Q) OR <br />_____ <br />E -15429N <br />G86-77-IDR7-NL <br />74753-33 <br />117NL-PE7M7 <br />_____ <br />H <br />2" BALL ANGLE METER VALVE - <br />P24276-N(P)/B24276-N(Q) <br />BFAl3-777W-NL(P)/BFA43-777W-Q-NL(Q) <br />746028-22(P)/7460280-2(0) <br />21ONL-B7MF7(P)/21 ONL-H7MF7(Q) <br />CTS X METER FLANGE - FULL PORT OR FlP X METER FLANGE <br />B -24286N-3 <br />BFA13-777WR-NL <br />74604B <br />21ONL-F7MF7 <br />_____ <br />_____ <br />J <br />2" METER, (BY CWS COMPANY) LENGTH 17" <br />----- <br />----- <br />z <br />ro <br />e� <br />2" METER FLANGE - FLG. X F.I.P; BRONZE WITH FULL FACE <br />K <br />GASKET AND X304 STAINLESS STEEL BOLTS &NUTS <br />----- <br />CF31-77-NL <br />7610E <br />421 NL -75 S <br />/ <br />----- <br />----- <br />L <br />2" NIPPLE <br />----- <br />----- <br />� <br />METER BOX - BROOKS CONCRETE #65 BOX W/ #65S CONCRETE <br />H <br />0 <br />z <br />M <br />COVER & UD OR CHRISTY CONCRETE B65 BOX W/ B65E <br />----- <br />----- <br />CONCRETE COVER & LID <br />DISTRICT: <br />NOTE: CAST IRON COVERS REQUIRED IN TRAFFIC AREAS <br />DATE: <br />9-19-22 <br />N <br />ADAPTER - 2" METER FLG. X 1-1/2" MET FLG. <br />----- <br />A67 -NL <br />71GJ67 <br />----- <br />NO.: <br />P <br />1-1/2" METER, (BY CWS COMPANY) LENGTH 13" <br />----- <br />----- <br />N <br />O <br />DRAWING NO.: <br />CW -1020R1 <br />1-1/2" METER FLANGE - FLG. X F.I.P.; BRONZE WITH FULL FACE <br />m 1 <br />OF <br />1 <br />Q <br />GASKET AND #304 STAINLESS STEEL BOLTS & NUTS <br />_____ <br />CF31-66-NL <br />761OF <br />421NL-6S/S <br />----- <br />----- <br />R <br />1-1/2" NIPPLE STD. LEAD-FREE BRASS <br />----- <br />----- <br />----- <br />_____ <br />_____ <br />----- <br />S <br />2" 90' ELL, RP X FlP <br />----- <br />----- <br />T <br />2" 90' ELL - MIP X CTS OR MIP X IPS <br />P15531-N(P)/H15531-N(Q) <br />LB4-77-NL(P)/L84-77-0-NL(Q) OR <br />74779M-22 2(P)/74779MQ-2(Q) OR <br />105NL-137M7(P)/l05NL-H7M7(Q) <br />_____ <br />I <br />_____ <br />786-77-IDR7-NL <br />74779M-33 <br />OR 105NL-B7M7 <br />TAPPED AT TOP <br />Mmkv <br />USE THIS INSTALLATION ONLY <br />FOR SERVICES LOCATED <br />DIRECTLY ABOVE THE MAIN <br />E <br />T <br />S <br />D <br />45" SIDE TAPPED <br />CONNECTION <br />FRONT VIEW <br />METER BOX <br />N #4 <br />�— SEE OPTION #4 <br />SIDE VIEW <br />METER BOX <br />ENGINEERING <br />py1FOnA, <br />9 U <br />SFA 8ER`1�G� <br />DEPARTMENT <br />REVISIONS: <br />RI. Add IPS fittings & <br />couplings In Lieu of <br />compression & CTS <br />fittings & couplings. LP <br />PLAT SHEET: <br />SCALE: I <br />N.T.S. <br />DRAWN BY: <br />10/13/22 <br />PRO <br />BY: <br />DATE: <br />10/28/2022 <br />wn: <br />mT. <br />➢W IO MON❑ <br />IYP <br />PUT <br />Nie <br />axe ❑ <br />ec�Pnc <br />.VON <br />El <br />- <br />van van <br />El <br />Wn <br />- <br />C -1 <br />N <br />H <br />O <br />'C1 <br />V <br />r <br />Tnco <br />ErJ <br />I <br />I <br />N <br />Li] <br />W <br />, <br />z <br />Z <br />z <br />ro <br />e� <br />� <br />z <br />� <br />H <br />0 <br />z <br />x <br />0 <br />a <br />DISTRICT: <br />DATE: <br />9-19-22 <br />ESTIMATE <br />NO.: <br />o <br />N <br />O <br />DRAWING NO.: <br />CW -1020R1 <br />m 1 <br />OF <br />1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.