Laserfiche WebLink
1 2 3 4 5 6 7 8 <br />CONTROL DIAGRAM SYMBOLS WIRING DEVICES MOTORS AND EQUIPMENT ONE-LINE DIAGRAM SYMBOLS <br />120V CONTROL RELAY SWITCHES: (-Y-Tn POWER TRANSFORMER. <br />CONTROL TRANSFORMER, PRIMARY 2 OPERATING COIL DISCONNECT SWITCH, NON-FUSED I SIZE 2 COMBINATION FULL VOLTAGE <br />AND SECONDARY VOLTAGES SHOWN, NON-REVERSING MAGNETIC STARTER 5.757 Z 480/277V IMPEDANCE SHOWN <br />SIZE AS SHOWN OR SPECIFIED CR CR = CONTROL RELAY UNLESS OTHERWISE SPECIFIED, ALL SWITCHES MCP SIZED BY MANUFACTURER <br />120V U = UNLATCH ARE WALL MOUNTED. MOT=MOTOR (OVERLOAD RELAY NOT SHOWN) <br />FUNCTION L = LATCH M SV=SOLENOID VALVE RV = REDUCED VOLTAGE <br />CV=CONTROL VALVE 2S2W = TWO-SPEED TWO-WINDING 480V <br />CIRCUIT BREAKER, THERMAL- TOGGLE SWITCH, SINGLE POLE, A=ADJUSTABLE SPEED DRIVE 2 = SIZE 2 30, 4W GENERATOR. POWER RATING, 40A RATING IN AMPS 125 = 125HP 600KW T <br />MAGNETIC, 3 POLE, LION, OL 20 AMP 12 FREQUENCY, VOLTAGE, <br />I THERMAL OVERLOAD RELAY 60HZ <br />GANGED SWITCHES IN COMMON BOX � FIELD INSTRUMENT SHOWN <br />2CR 2CR <br />DESIGNATES PLC INPUT $ $ WITH COMMON WALL PLATE 400/3 -_ <br />n TERMINATION OR CONTROL F- �/�— OUTPUT CONTACTS 3 CURRENT TRANSFORMER WITH <br />Ip <br />PANEL TERMINATION SUPERSCRIPT INDICATES CIRCUIT CONTROL STATION. SEE CONTROL DIAGRAMS FOR DEVICES REQUIRED 3 RATIO AND NUMBER OF UNITS <br />_ <br />FUSE 2 TIMING RELAY CONTROLLED: a, b, c, ETC. MAY BE 200 AMP SHOWN <br />TR OPERATING COIL A COMBINED WITH CIRCUIT NUMBER. 200A <br />MODIFIERS: EXAMPLE: la, 4b, ETC. <br />CLF = CURRENT LIMITING FUSE ON or OFF DELAY 3 TELEPHONE & COMMUNICATION SYSTEMS <br />DE = DUAL ELEMENT RANGE:SEC/MIN B MAIN SERVICE METER <br />F = CLASS F FUSE WITH <br />SET:SEC/MIN <br />Ip SUBSCRIPT MODIFIER INDICATES: FU BLOWN INDICATOR <br />1_2 = DOUBLE POLE UNLESS OTHERWISE SPECIFIED, TELEPHONE <br />O O PUSHBUTTON, MOMENTARY CONTACT, 3 = THREE WAY OUTLETS SHALL BE MOUNTED AT SAME HEIGHT <br />DESCPTN NORMALLY OPEN NOROMA LY NORC OSE Y 4 = FOUR WAY AS THE RECEPTACLES, VERIFY. MF MULTI-FUNCTION ELECTRONIC METER <br />ID <br />K = KEY OPERATED EXTERNAL LINE OR PLANT PHONE f <br />3 PUSHBUTTON, MOMENTARY CONTACT, 2TR 2TR OR DELAY ON COIL MC = MOMENTARY CONTACT, THREE SYSTEM OUTLET <br />O I O NORMALLY CLOSED O OR � ENERGIZATION POSITION , <br />DESCPTN TC TO ON DELAY MS = MANUAL (MOTOR) STARTER OR MODIFIERS: <br />ID SWITCH T TELEPHONE <br />STOP PUSHBUTTON WITH LOCKOUT �O 0—:T0R = RHEOSTAT (DIMMER, SPEED� POSITION (LIMIT) <br />SWITCH CONTROL) <br />DESCPTN RECEPTACLES: <br />O GROUNDING GENERAL NOTES <br />ID TEMPERATURE <br />SWITCH UNLESS OTHERWISE SPECIFIED, ALL RECEPTACLES <br />O ARE 125 VOLT, SINGLE PHASE, STRAIGHT BLADE, <br />H A NON LOCKING, GROUNDING STYLE. O GROUND ROD 1. THIS DRAWING IS GENERAL IN NATURE. SOME SYMBOLS SHOWN HEREON MAY NOT BE <br />PRESSURE <br />O USED ON THE CONTRACT DRAWINGS. <br />SWITCH �Q} GROUND ROD WITH GROUND WELL 2. IDENTIFICATIONS (ID), SIZES, RATINGS, LOCATIONS AND SIMILAR INFORMATION SHOWN <br />SELECTOR SWITCH DUPLEX RECEPTACLE, 20 AMP, `CY 3 WIRE ASSOCIATED WITH SYMBOLS ARE OPTIONAL; EXAMPLES OF SUCH INFORMATION ARE <br />3 POSITION MAINTAINED CONTACT SHOWN WITH SOME SYMBOLS FOR CLARITY. <br />X = CONTACTS CLOSED RECEPTACLE MODIFIERS: GROUND CONNECTION, BOLTED TYPE <br />3. THE ELECTRICAL DRAWINGS USE THE ONE-LINE DIAGRAMS AND PANEL SCHEDULES IN <br />GROUND CONNECTION, COMPRESSION CONJUNCTION WITH SHOWING THE LOCATION OF THE ELECTRICAL/INSTRUMENTATION <br />46 L = LENS COLOR: WP = WEATHER PROOF TYPE SOURCES AND LOADS/DEVICES SHOWN ON THE PLAN DRAWINGS TO DEPICT THE WORK. <br />GF = GROUND FAULT CIRCUIT THE CONTRACTOR SHALL USE THESE DOCUMENTS TO DETERMINE AND PROVIDE THE <br />A =AMBER INTERRUPTER NECESSARY RACEWAY AND WIRING SYSTEM FOR EACH CIRCUIT. ALL INDOOR RACEWAY <br />B = BLUE H = HAZARDOUS AREA- G GROUNDING CONDUCTOR, MINIMUM SHALL BE RUN EXPOSED, AND ROUTED BY THE CONTRACTOR, UNLESS OTHERWISE <br />G = GREEN EXPLOSION PROOF #2/0 BARE COPPER NOTED. THE TYPE OF RACEWAY AND WIRE USED SHALL BE AS SPECIFIED IN THE <br />R = RED SPECIFICATIONS UNLESS OTHERWISE NOTED. <br />LINEW = WHITE DOUBLE DUPLEX RECEPTACLE, 4. THE LOCATION OF THE CONTROL STATIONS SHOWN ON THE PLAN DRAWINGS ARE <br />INDICATING LIGHT INSTRUMENT CABLE SHIELD GROUND DIAGRAMMATIC AND THE ACTUAL LOCATION SHALL BE COORDINATED IN THE FIELD WITH <br />L <br />THE OWNER. <br />PUSH TO TEST, TEST —_ <br />LEGEND VOLTAGE TERMINAL SHOWN 5. THE EXACT LOCATION OF THE MOTORS AND ACCESSORIES ARE NOT SHOWN. THE <br />CONTRACTOR SHALL COORDINATE AND REFER TO OTHER DRAWINGS FOR CONDUIT <br />STUBOUT AND TERMINATION LOCATIONS. <br />STANDARD ABBREVIATIONS LIGHTING CIRCUITS AND RACEWAYS MISCELLANEOUS 6. ALL EQUIPMENT SHALL BE LABELED WITH NAMEPLATES. DESCRIPTION OF EQUIPMENT <br />SHALL BE IN ACCORDANCE WITH THE ONE-LINE DIAGRAM DESCRIPTION. A LIST OF THE <br />NAMEPLATES SHALL BE SUBMITTED TO THE CONSTRUCTION MANAGER PRIOR TO <br />ENGRAVING. <br />FIXTURE IDENTIFIER: "" OVERHEAD POWER LINES <br />A AMMETER 1 7. UNLESS OTHERWISE NOTED, ALL CONVENIENCE OUTLETS SHALL BE MOUNTED AT <br />AUTOMATIC TRANSFER SWITCH - RACEWAY IN CONCRETE TYPICAL DETAIL DESIGNATION 48-INCHES ABOVE FINISHED FLOOR. ALL LIGHT SWITCHES SHALL BE MOUNTED AT <br />ATS NUMBER OF FIXTURES (SHOWN TYP E-7 54-INCHES ABOVE FINISHED FLOOR. <br />CONDUIT BCW BARE COPPER WIRE ONLY WHEN REQUIRED FOR <br />C CONDUIT ONLY (EMPTY CONDUIT) CLARITY) — — — RACEWAY CONCEALED (UNDERGROUND) 8. EACH CONVENIENCE OUTLET AND LIGHTING CIRCUIT SHALL BE PROVIDED WITH A #12AWG <br />C.O. <br />CP CONTROL PANEL II� GROUND CONNECTION GREEN GROUNDING CONDUCTOR <br />CPT CONTROL POWER TRANSFORMER FIXTURE TYPE REFER TO FIXTURE RACEWAY TURNED TOWARD <br />CS CONTROL SWITCH SCHEDULE TYPE APPLIES TO ALL THE VIEWER. PROGRAMMABLE LOGIC 9. IN GENERAL, LANDFILL SITE IS CONSIDERED AS CLASSIFIED HAZARDOUS LOCATION. ALL <br />CT CONTACTOR (HEAVY DUTY) FIXTURES OF THE SAME SHAPE CONTROLLER 1/0 CONDUITS ENTERING OR LEAVING UNDERGROUND SHALL BE PROVIDED WITH "EYS" SEALS <br />FS FLOAT SWITCH WITHIN A ROOM OR AREA.RACEWAY TURNED DOWN FILLED WITH COMPOUND RECOMMENDED BY SEAL MANUFACTURER AFTER CONDUCTORS <br />G GROUND ARE INSTALLED. <br />HZ HERTZ O THERMOSTAT <br />KVAR REACTIVE POWER R MOUNTING: EXPOSED RACEWAY <br />KW K I LOWATT <br />KWHR KILOWATTHOUR 5 XX C = CEILING R = RECESSED HH23 O NOTE DESIGNATION <br />1/0 INPUT/OUTPUT 2/408-6 PP = POLE S = STANCHION MANHOLE (MH) OR HANDHOLE (HH), <br />LOS LOCKOUT STOP P = PENDANT W = WALL DESIGNATES EQUIPMENT OR <br />MOTOR CONTROL CENTER p <br />MCC DEVICE LOCATED AT LOAD Underground Service Alert <br />MCP MOTOR CIRCUIT PROTECTOR IN THE FIELD <br />MF MULTI-FUNCTION METER DISPLAY MOUNTING HEIGHT, FLOOR TO O JUNCTION BOX. o Call: TOLL FREE <br />MIN MINIMUM 1-800 <br />MSGR MAIN SWITCHGEAR BOTTOM OF FIXTURE LION. DESIGNATES EQUIPMENT OR 227-2600 <br />NC NORMALLY CLOSED AHAP = AS HIGH AS POSSIBLE. TB TERMINAL BOX. DEVICES LOCATED IN MCC <br />TWO WORKING DAYS <br />NIC NOT IN CONTRACT BEFORE YOU DIG <br />NO NORMALLY OPEN 3#10 AWG DESIGNATES EQUIPMENT OR <br />PAIR OR PR TWISTED, SHIELDED PAIRS NUMBER OF LAMPS/LAMP WATTAGE DEVICES LOCATED IN IF SHEET IS LESS THAN 24" BY 36", THEN IT IS A REDUCED PRINT-SCALE REDUCED ACCORDINGLY. <br />PB PULL BOX + #10 AWG G, 1 C CONTROL PANEL E <br />PLC PROGRAMMABLE LOGIC CONTROLLER LIGHTING FIXTURE SHAPES AND SCALE ARE RACEWAY SIZE WITH CONDUCTOR <br />PP POWER POLE REPRESENTED WHERE POSSIBLE. THE CONTENTS AND SIZES. PUMP CONTROLLERS <br />OH OVERHEAD REV DATE DESCRIPTION DRN APP <br />RESISTANCE THERMAL DETECTOR EXAMPLES SHOWN BELOW ARE TYPICAL LP-1 DISCRETE OUTPUT <br />RTD APPLICATIONS. <br />RTU REMOTE TERMINAL UNIT CIRCUIT HOMERUN W/ DESTINATION <br />SCADA SUPERVISORY CONTROL & DATA ACQUISITION NOTED (2#12, #12 GND MIN.) IONIZATION SMOKE DETECTOR Geosynte& <br />SSRS <br />SOLID STATE REDUCED VOLTAGE STARTER ENGINEERS, INC. <br />SWGR SWITCHGEAR FLUORESCENT FIXTURE �� TELEPHONE SYSTEM CONDUIT consultants Oakland, San Francisco, Orange County, CA <br />THD HARMONIC DISTORTION T El END—OF—LINE DEVICE <br />TS TEMPERATURE SWITCH / WITH PULLING NYLON ROPE 1111 BROADWAY, 6TH FLOOR 1611 TELEGRAPH ABENUE, SUITE 609 1810 EAST HAMILTON AVENUE <br />V VOLTMETER OAKLAND, CA 94607 OAKLAND, CA 94612 STOCKTON, CA 95205 <br />VFD VARIABLE FREQUENCY DRIVE LIGHT CIRCUIT W/ CONDUCTOR �F FIRE ALARM PULLSTATION PHONE: 510.636.3034 PHONE: 510.267.0441 PHONE: 209.466.3000 WP WEATHER PROOF (NEMA 4X) I 0 I _o WALL MOUNTED FIXTURE <br />XFMR TRANSFORMER QUANTITY INDICATED TITLE: <br />ELECTRICAL LEGEND AND GENERAL NOTES <br />FVNV FULL VOLTAGE NON-REVERSING STARTER <br />MDP-4XX DESIGNATES 480V CIRCUIT �F COMBINATION STROBE LIGHT/HORN <br />PROJECT: <br />\ \ EMERGENCY LIGHTING UNIT. PS-21 XX DESIGNATES 21 KV CIRCUITCONSTRUCTION OF AREA 2A <br />SELF CONTAINED. FIREALARM CONTROL PANEL <br />ZULF SPACE HEATER SITE: FOOTHILL SANITARY LANDFILL <br />SAN JOAQUIN COUNTY, CALIFORNIA f <br />THIS DRAWING MAY NOT BE ISSUED QqpFESS10 DESIGN BY: TP DATE: NOVEMBER 2014 <br />FOR PROJECT TENDER OR Q `� <br />CONSTRUCTION, UNLESS SEALED. y O }� AWN BY: LD PROJECT NO.: WG1780 <br />v <br />CHECKED BY: DN FILE: WG1780_EO01 <br />SI TURE REVIEWED BY: DTN DRAWING NO.: E-1 <br />D �OAL PROVED BY: DTN 14 of 25 <br />1 2 3 4 5 6 7 8 <br />