Laserfiche WebLink
2 <br />LIGHTNING <br />SURGE <br />ARRESTOR <br />L1 ( MS1 OL T1 <br />0r <br />I <br />480V POWER L2i MS1 OL T2 <br />SUPPLY FROM > IF <br />PANEL DP2 L3 i I MS1 OL T3 <br />HC1 <br />PANEL <br />HC1 HEATERS <br />10OW 10OW <br />480V 480V <br />7 L480VOV <br />C 500VA CPT <br />X1 120V <br />CR <br />7 <br />CONTROL <br />W POWER <br />AVAILABLE <br />CONVENIENCE <br />SURGE <br />SUPPRESSOR GFI OUTLET <br />E <br />PANEL HEATER <br />CONTROL <br />THERMOSTAT <br />----� NOTE 2 <br />CRLSHTIC <br />40 <br />CRI LEACHATE TANK <br />LEACHATE FULL INTERLOCK <br />TANK FULL THESE DRY CONTACTS ARE LOCATED CONTROL <br />L — — — — J REMOTELY IN EXISTING MAIN TANK CONTROL <br />F — — — — PANEL. SEE E-5 FOR DETAILS <br />CR2 <br />CR2 REMOTE <br />REMOTE CONTROL <br />CONTROL INTERLOCK <br />SELECTION <br />L ----J NOTE 2 <br />M 1(A) <br />CR3 SUMP LOW LOW <br />(LOW LOW LEVEL ALARM LEVEL CONTROL <br />AND SHUT DOWN) <br />H 0 A OL <br />MSI SUMP PUMP <br />I <br />M1(B) CR3 CR1 CR2 MS1 CONTROLLER <br />0 R SUMP PUMP <br />RUNNING <br />START STOP RTM <br />COMMAND RUN TIME METER <br />BY LEVEL OL <br />CONTROLLER <br />R MOTOR <br />OVERLOAD ALARM <br />CR6 <br />CR3 <br />R SUMP LOW LOW <br />LEVEL ALARM <br />CR1 <br />R LEACHATE TANK <br />FULL ALARM <br />2 <br />LEACH A <br />E-4 E-4 SCALE: NTS <br />3 <br />LEACHATE PUMP/MOTOR <br />IN SUMP <br />M <br />� p <br />SUBMARINE <br />CABLE <br />A CON TR <br />MS1 <br />SUMP PUMP <br />RUN RUNNING <br />CR4 <br />CR6 <br />SUMP HI HI <br />LEVEL ALARM <br />PUMP OVELOAD <br />ALARM <br />CR3 <br />SUMP LOW LOW <br />LEVEL ALARM <br />CR7 <br />CONTROL POWER SPARES FOR <br />FAILURE FUTURE USES <br />NOTES: <br />1. UNLESS OTHERWISE NOTED, ALL DEVICES ARE LOCATED IN THE PUMP CONTROL PANEL. <br />2. SEE DETAIL 1 ON DRAWING E-5 <br />5 <br />SET O 5 SEC <br />COMMON <br />SHUTDOWN <br />SUMP HI HI <br />LEVEL ALARM <br />BEACON LIGHT <br />COMMON <br />SHUTDOWN <br />ALARM <br />5 <br />E -2,E <br />6 � 7 <br />SUMP <br />.L" <br />NOTE 1 <br />NOTES: <br />1. THIS PANEL SHALL BE NEMA 4 (WEATHER PROOF, RAIN PROOF, AND CORROSIVE RESISTANT). DO NOT INSTALL <br />ANY OTHER SCREW WHICH MAY PREVENT QUICK OPENING OF THE PANEL. SIZE OF PANEL SHALL BE AS <br />REQUIRED BY INTERNAL COMPONENTS SPECIFIED. <br />2. THE PANEL SHALL BE UL508 LISTED AND LABELED BY THE MANUFACTURER. <br />3. SEE CONTROL SCHEMATIC DIAGRAM SHOWN ON THIS DRAWING FOR COMPLETE INTERNAL COMPONENTS REQUIRED <br />FOR THE PUMP CONTROL. <br />AREA 2A - LEACHATE <br />D <br />Underground Service Alert <br />OD4 Call: TOLL FREE <br />1-800 <br />227-2600 <br />TWO WORKING DAYS <br />BEFORE YOU DIG <br />IF SHEET IS LESS THAN 24" BY 36", THEN IT IS A REDUCED PRINT -SCALE REDUCED ACCORDINGLY. <br />REV DATE DESCRIPTION DRN APP <br />Geosyntecc' ENGINEERS INC. , <br />consultants Oakland, San Francisco, Orange County, CA <br />1111 BROADWAY, 6TH FLOOR 1511 TELEGRAPH ASENUE, SUITE 809 1810 EAST HAZELTON AVENUE <br />OAKLAND, CA 94607 OAKLAND, CA 94612 STOCKTON. CA 95205 <br />PHONE: 510.836.3034 PHONE: 510.267.0441 PHONE: 209.468.3000 <br />TITLE: <br />PROJECT: <br />PUMP CONTROL SCHEMATIC DIAGRAMS <br />CONSTRUCTION OF AREA 2A <br />SITE: FOOTHILL SANITARY LANDFILL <br />SAN JOAQUIN COUNTY, CALIFORNIA <br />THIS DRANANG MAY NOT BE ISSUED Q�FES$/p,, DESIGN BY: TP DATE: NOVEMBER 2014 <br />FOR PROJECT TENDER OR �p� t AN �_7/�� <br />CONSTRUCTION, UNLESS SEALED. �" <br />h O� � � DRAWN BY: LD PROJECT NO.: WG17SO <br />� E-� 7p CHECKED BY: DN FILE: WG178O_EOO4 <br />ATU REVIEWED BY: DTN DRAWING NO.: E_4 <br />DATE � CAU � PROVED BY: DTN =- OF <br />7 8 <br />