My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
F281 - F305
PublicWorks
>
VAULT MAPS
>
Large Plans - LP
>
Drawer F
>
F267 Thru F350
>
F281 - F305
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/11/2023 2:42:31 PM
Creation date
8/11/2023 2:32:50 PM
Metadata
Fields
Template:
Large Plans - LP
Project
Construction of Area 2A at the Foothill Sanitary Landfill
Year
2014
Red Lines
No
Supplemental fields
CrossRef
F281 - F305
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
2 <br />SYMBOLS <br />UA AUTODIALER <br />X <br />GX GENERAL ALARM 1 <br />A <br />XH LEVEL ALARM HI * HS OFF -AUTO <br />CP <br />I <br />HH LEVEL ALARM HI—HI <br />3�K <br />BEACON <br />**31i <br />A <br />2 <br />YL <br />X OPERATIONAL LIGHTS LI I *** S2 <br />*** H---�--- L H *** <br />S2 S2 <br />LE LEVEL SENSOR ELEMENT <br />X *** LSH I FI <br />S2 7 S <br />LI 1 *** LSL I <br />X LEVEL INDICATOR S2 6 <br />I <br />I <br />I <br />B LSHH BUBBLER <br />X LEVEL SWITCH HI -HI TUBE I <br />I <br />A <br />E <br />F <br />I <br />I <br />I <br />i <br />I <br />I <br />I I <br />~ X <br />I <br />i <br />i <br />I <br />i <br />HOA <br />HS <br />Q *** S2 <br />2 I <br />I <br />*** <br />FILTER W/ S26 <br />SAMPLING <br />VALVE <br />IO <br />I \6/ <br />7 <br />r --------------J <br />I <br />INTERLOCK LIST <br /><j> <br />LEACHATE TANK 1 LEVEL LOW STOP LEACHATE <br />1 TRANSFER PUMP STOP LEACHATE RETURN PUMP <br />I LEACHATE TANK 1 LEVEL HIGH STOP LEACHATE <br />2 COLLECTION SUMP PUMP 1&2 STOP CONTAINMENT <br />AREA SPILL SUMP PUMP STOP LOADING AREA SPILL <br />SUMP PUMP INITIATE ALARM <br />I LEACHATE COLLECTION SUMP 1 LEVEL LOW STOP <br />3 LEACHATE COLLECTION SUMP PUMP 1 <br />I LEACHATE COLLECTION SUMP 1 LEVEL HIGH START <br />4 LEACHATE COLLECTION SUMP PUMP 1 <br />OI SECONDARY SUMP PUMP AREA 1 STOPS WHEN WATER <br />5 IS INSUFFICIENT INDICATED BY MOTOR AMPERAGE <br />Oj LEACHATE COLLECTION SUMP 2 LEVEL LOW STOP <br />6 LEACHATE COLLECTION SUMP PUMP 2 <br />I LEACHATE COLLECTION SUMP 2 LEVEL HIGH START <br />7 LEACHATE COLLECTION SUMP PUMP 2 <br />F1%S <br />LEACHATE COLLECTION SUMP PUMP 2A <br />(NON RESETTABLE) <br />BUBBLER <br />TUBE <br />LEACHATE COLLECTION - SECONDARY SUMP <br />3 <br />rd <br />NEW WORK <br />NO 2" HDPE PIPE <br />NC <br />TO TRUCK <br />... ... ..... <br />TO REFUSE FILL <br />3" HDPE PIPE <br />1 4" 1 <br />I <br />I <br />I <br />=1Q <br />S1 <br />FILTER W/ <br />SAMPLINGG VALVE <br />LEACHATE COLLECTION SUMP PUMP 1 <br />3 <br />SE FORCE MAIN I <br />OFF -AUTO <br />HS <br />H HOA <br />'-HS' <br />S1 - <br />YL <br />S1B.;` <br />LCRS DRAIN PIPES <br />1 LLAUH <br />-8 E-8 SCALE: NTS <br />I <br />I <br />I <br />THIS <br />DISCHARGE <br />PIPE <br />SHALL 1 <br />BE <br />ONE <br />PIECE <br />I <br />1 4" <br />5 <br />1 " HDPE <br />LFG CONDENSATE <br />FI <br />S1 <br />2" VENT <br />LI <br />T1 <br />SHEET NOTES: <br />U REFER TO ELECTRICAL DETAILS FOR EXACT LOCATION OF DEVICES SHOWN. <br />O2 THE LEVEL TRANSMITTER SHALL BE INSTALLED IN A 2" PVC PIPE. A 1/4" <br />POLYETHYLENE BUBBLER TUBE SHALL BE INSTALLED ALONG THIS 2" PVC PIPE <br />(WRAPPED AROUND WITH 10ML CALPICO TAPE). THIS 2"PVC PIPE AND THE <br />1/4" PE BUBBLER TUBE SHALL BE INSTALLED IN THE 6" HDPE CARRIER PIPE. <br />OWHILE ALL THE SETTINGS ARE PROGRAMMABLE, INITIAL SETTINGS OF THE LEVEL <br />CONTROLLER SHALL BE: <br />- HI LEVEL ALARM AT 3' WATER DEPTH FROM SUMP DATUM <br />- PUMP STARTS AT 2.5' WATER DEPTH FROM SUMP DATUM <br />- PUMP STOPS AT 9" WATER DEPTH FROM SUMP DATUM <br />NOTE: TOTAL SUMP DEPTH IS 4.5 FEET. <br />12 -IN HDPE LANDFILL GAS <br />HIGH PRESSURE AIR <br />PULSE COUNTER FQ- -pj; FROM COMPRESSOR <br />LEACHATE TANK 1 <br />2" <br />FIQ <br />T1 <br />(RESETTAULL) <br />YL <br />1A <br />LFG CONDENSATE <br />IS DELIVERED TO <br />THE LEACHATE <br />COLLECTION AND <br />RECOVERY SYSTEM <br />M -PR <br />4 I 5 <br />101 <br />OFF <br />AUTO ^ _ AUTO <br />FADING <br />REV DATE DESCRIPTION DRN APP <br />GeosvnteO' <br />ENGINEERS, INC. <br />consultants <br />Oakland, San Francisco, Orange County, CA <br />1111 BROADWAY, 8TH FLOOR 1611 TELEGRAPH ABENUE, SUITE 809 1810 EAST HAZELTON AVENUE <br />OAKLAND, CA 84607 OAKLAND, CA 94612 STOCKTON, CA 95205 <br />PHONE: 510.836.3034 PHONE: 510.267.0441 PHONE: 209.468.3000 <br />TITLE: <br />LEACHATE SYSTEM P&ID <br />PROJECT: <br />CONSTRUCTION OF AREA 2A <br />SITE: FOOTHILL SANITARY LANDFILL <br />SAN JOAQUIN COUNTY, CALIFORNIA <br />THIS DRAWING MAY NOT BE ISSUED QSOFESS10 DESIGN BY: Tp DATE: NOVEMBER 2014 <br />FOR PROJECT TENDER OR �Q t AN(� <br />CONSTRUCTION, UNLESS SEALED. <br />y �� %.t►_ � DRAWN BY: LD PROJECT NO.: WGl %BO <br />`f CHECKED BY: DN FILE: WG1780_EO08 <br />JE REVIEWED BY: DTN DRAWING NO.: E-8 <br />21 <br />DATE CALF_ �� PPROVED BY: DTN OF 25 <br />7 8 <br />LSH <br />X <br />LEVEL SWITCH HI <br />LSL <br />X <br />LEVEL SWITCH LO <br />1 <br />HS <br />X <br />HAND SWITCH <br />FQ <br />X <br />FLOW INDICATOR <br />I <br />C <br />X <br />FLOW INDICATOR/TOTALIZER <br />— <br />KY <br />X <br />TIME DELAY RELAY <br /><i> <br />ELECTRICAL INTERLOCK <br />X <br />(SEE INTERLOCK LIST) <br />* <br />INDICATES DEVICE IS LOCATED <br />AT LEACHATE TANK <br />CONTROL PANEL <br />** <br />INDICATES DEVICE IS LOCATED <br />AT LEACHATE <br />COLLECTION SUMP PUMP 1 CONTROL PANEL <br />*** <br />INDICATES DEVICE IS LOCATED <br />AT LEACHATE <br />COLLECTION SUMP PUMP 2 CONTROL PANEL <br />A <br />E <br />F <br />I <br />I <br />I <br />i <br />I <br />I <br />I I <br />~ X <br />I <br />i <br />i <br />I <br />i <br />HOA <br />HS <br />Q *** S2 <br />2 I <br />I <br />*** <br />FILTER W/ S26 <br />SAMPLING <br />VALVE <br />IO <br />I \6/ <br />7 <br />r --------------J <br />I <br />INTERLOCK LIST <br /><j> <br />LEACHATE TANK 1 LEVEL LOW STOP LEACHATE <br />1 TRANSFER PUMP STOP LEACHATE RETURN PUMP <br />I LEACHATE TANK 1 LEVEL HIGH STOP LEACHATE <br />2 COLLECTION SUMP PUMP 1&2 STOP CONTAINMENT <br />AREA SPILL SUMP PUMP STOP LOADING AREA SPILL <br />SUMP PUMP INITIATE ALARM <br />I LEACHATE COLLECTION SUMP 1 LEVEL LOW STOP <br />3 LEACHATE COLLECTION SUMP PUMP 1 <br />I LEACHATE COLLECTION SUMP 1 LEVEL HIGH START <br />4 LEACHATE COLLECTION SUMP PUMP 1 <br />OI SECONDARY SUMP PUMP AREA 1 STOPS WHEN WATER <br />5 IS INSUFFICIENT INDICATED BY MOTOR AMPERAGE <br />Oj LEACHATE COLLECTION SUMP 2 LEVEL LOW STOP <br />6 LEACHATE COLLECTION SUMP PUMP 2 <br />I LEACHATE COLLECTION SUMP 2 LEVEL HIGH START <br />7 LEACHATE COLLECTION SUMP PUMP 2 <br />F1%S <br />LEACHATE COLLECTION SUMP PUMP 2A <br />(NON RESETTABLE) <br />BUBBLER <br />TUBE <br />LEACHATE COLLECTION - SECONDARY SUMP <br />3 <br />rd <br />NEW WORK <br />NO 2" HDPE PIPE <br />NC <br />TO TRUCK <br />... ... ..... <br />TO REFUSE FILL <br />3" HDPE PIPE <br />1 4" 1 <br />I <br />I <br />I <br />=1Q <br />S1 <br />FILTER W/ <br />SAMPLINGG VALVE <br />LEACHATE COLLECTION SUMP PUMP 1 <br />3 <br />SE FORCE MAIN I <br />OFF -AUTO <br />HS <br />H HOA <br />'-HS' <br />S1 - <br />YL <br />S1B.;` <br />LCRS DRAIN PIPES <br />1 LLAUH <br />-8 E-8 SCALE: NTS <br />I <br />I <br />I <br />THIS <br />DISCHARGE <br />PIPE <br />SHALL 1 <br />BE <br />ONE <br />PIECE <br />I <br />1 4" <br />5 <br />1 " HDPE <br />LFG CONDENSATE <br />FI <br />S1 <br />2" VENT <br />LI <br />T1 <br />SHEET NOTES: <br />U REFER TO ELECTRICAL DETAILS FOR EXACT LOCATION OF DEVICES SHOWN. <br />O2 THE LEVEL TRANSMITTER SHALL BE INSTALLED IN A 2" PVC PIPE. A 1/4" <br />POLYETHYLENE BUBBLER TUBE SHALL BE INSTALLED ALONG THIS 2" PVC PIPE <br />(WRAPPED AROUND WITH 10ML CALPICO TAPE). THIS 2"PVC PIPE AND THE <br />1/4" PE BUBBLER TUBE SHALL BE INSTALLED IN THE 6" HDPE CARRIER PIPE. <br />OWHILE ALL THE SETTINGS ARE PROGRAMMABLE, INITIAL SETTINGS OF THE LEVEL <br />CONTROLLER SHALL BE: <br />- HI LEVEL ALARM AT 3' WATER DEPTH FROM SUMP DATUM <br />- PUMP STARTS AT 2.5' WATER DEPTH FROM SUMP DATUM <br />- PUMP STOPS AT 9" WATER DEPTH FROM SUMP DATUM <br />NOTE: TOTAL SUMP DEPTH IS 4.5 FEET. <br />12 -IN HDPE LANDFILL GAS <br />HIGH PRESSURE AIR <br />PULSE COUNTER FQ- -pj; FROM COMPRESSOR <br />LEACHATE TANK 1 <br />2" <br />FIQ <br />T1 <br />(RESETTAULL) <br />YL <br />1A <br />LFG CONDENSATE <br />IS DELIVERED TO <br />THE LEACHATE <br />COLLECTION AND <br />RECOVERY SYSTEM <br />M -PR <br />4 I 5 <br />101 <br />OFF <br />AUTO ^ _ AUTO <br />FADING <br />REV DATE DESCRIPTION DRN APP <br />GeosvnteO' <br />ENGINEERS, INC. <br />consultants <br />Oakland, San Francisco, Orange County, CA <br />1111 BROADWAY, 8TH FLOOR 1611 TELEGRAPH ABENUE, SUITE 809 1810 EAST HAZELTON AVENUE <br />OAKLAND, CA 84607 OAKLAND, CA 94612 STOCKTON, CA 95205 <br />PHONE: 510.836.3034 PHONE: 510.267.0441 PHONE: 209.468.3000 <br />TITLE: <br />LEACHATE SYSTEM P&ID <br />PROJECT: <br />CONSTRUCTION OF AREA 2A <br />SITE: FOOTHILL SANITARY LANDFILL <br />SAN JOAQUIN COUNTY, CALIFORNIA <br />THIS DRAWING MAY NOT BE ISSUED QSOFESS10 DESIGN BY: Tp DATE: NOVEMBER 2014 <br />FOR PROJECT TENDER OR �Q t AN(� <br />CONSTRUCTION, UNLESS SEALED. <br />y �� %.t►_ � DRAWN BY: LD PROJECT NO.: WGl %BO <br />`f CHECKED BY: DN FILE: WG1780_EO08 <br />JE REVIEWED BY: DTN DRAWING NO.: E-8 <br />21 <br />DATE CALF_ �� PPROVED BY: DTN OF 25 <br />7 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.