Laserfiche WebLink
RL P U E ACQUISTION NOTE <br />CONTRACTOR TO VERIFY RIGHT OF WAY, <br />PUBLIC UTILITY EASEMENT AND/OR PUBLIC <br />SERVICE EASEMENT ACQUISTION WITH THE <br />APPLICANT PRIOR TO CONSTRUCTION WITHIN <br />AREAS OF QUESTION. <br />3701 <br />S MACARTHUR DR, <br />TRACY, <br />CA 95377 <br />EXISTING NODE PED <br />SPLICE & ACTIVATIONS <br />END <br />WILL <br />BE <br />ROAD WORK <br />BETWEEN 6:00 AM <br />AND <br />G20-2 <br />125' <br />so' <br />R/W <br />R/W <br />R/W <br />GREEN AREA <br />DM <br />ONE <br />LANE OF <br />TRAFFIC SHALL BE <br />FOC <br />OPEN <br />TO THE <br />GENERAL PUBLIC." <br />320 FT. <br />9 <br />BIKELANE <br />250 FT. <br />45 MPH <br />540 FT. <br />[ <br />Flashing Arrow Sign (Where Required) <br />350 FT. <br />0 <br />600 FT. <br />13 <br />Refer to Page 7 of Caltrans manual <br />500 FT. <br />Of <br />1000 FT. <br />21 <br />Type A, Type I , or Type H . <br />1000 FT. <br />Y <br />High Level Warning Device (Flagtree) <br />Barricade (For Excavation Only) <br />Refer to Page 12 of Coltrane manual <br />EOP <br />to select for Details on <br />Type I , Type H , or Type HE . <br />R/W <br />R/W <br />Flogger <br />250' <br />FAHEAD <br />1-1 <br />VW116-1 <br />RIGHT <br />SHOULDER <br />SHOULDER <br />"NO LANE CLOSURE <br />WILL <br />BE <br />ALLOWED <br />BETWEEN 6:00 AM <br />AND <br />9:00 <br />AM AND <br />BETWEEN 3:30 PM <br />AND <br />6:30 <br />PM. AT <br />OTHER TIMES, AT LEAST <br />Sign <br />ONE <br />LANE OF <br />TRAFFIC SHALL BE <br />KEPT <br />OPEN <br />TO THE <br />GENERAL PUBLIC." <br />320 FT. <br />9 <br />( Not a pavement marking ) <br />CONE TAPER = (16T) <br />TAPER = (1,357') <br />THIS IS AN COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIAL <br />DESIGN: N.PE REV DESCRIPTION DATE <br />DRAWN BY: SO.IB 0 ISSUE FOR PERMIT 07/14/2023 <br />APPROVED: <br />APPROVED: <br />APPROVED: <br />SCOPE OF WORK <br />iO SPLICE ON (08) EXISTING LOCATIONS. <br />LINETYPES <br />R/W <br />DIRT AREA <br />125' <br />RIGHT OF WAY <br />END <br />ROAD WORK <br />G20-2 27510 <br />S MACARTHUR DR, <br />TRACY, <br />A 95377 <br />IMPORTANT NOTICE <br />Section # 4216/4217 of the Government Code requires a <br />Dig Alert Identification Number to be issued before a <br />"Permit to Excavate" will be valid For your Dig Alert I.D. <br />CALL TOLL FREE <br />48 HOURS BEFORE YOU DIG <br />UNDERGROUND SERVICE ALERT <br />1-800-227-2600 <br />DIRT AREA <br />APPROACH <br />SPEED <br />TAPER <br />LENGTH <br />(L)< <br />NO. OF <br />CONES <br />PER TAPER <br />LEGEND <br />SIGN SPACING (S) <br />ADVANCE OF TAPER <br />& BETWEEN SIGNS <br />25 MPH <br />125 FT. <br />• <br />Traffic Cone or Delineator <br />100 FT. <br />30 MPH <br />180 FT. <br />7 <br />Sign <br />250 FT. <br />35 MPH <br />245 FT. <br />8 <br />Direction of Travel <br />250 FT. <br />40 MPH <br />320 FT. <br />9 <br />( Not a pavement marking ) <br />250 FT. <br />45 MPH <br />540 FT. <br />[ <br />Flashing Arrow Sign (Where Required) <br />350 FT. <br />50 MPH <br />600 FT. <br />13 <br />Refer to Page 7 of Caltrans manual <br />500 FT. <br />50+ MPH <br />1000 FT. <br />21 <br />Type A, Type I , or Type H . <br />1000 FT. <br />Y <br />High Level Warning Device (Flagtree) <br />Barricade (For Excavation Only) <br />Refer to Page 12 of Coltrane manual <br />to select for Details on <br />Type I , Type H , or Type HE . <br />Flogger <br />1-1 <br />VW116-1 <br />RIGHT <br />SHOULDER <br />SHOULDER <br />CLOSED <br />CLOSED <br />AHEAD <br />P C30A(CA) <br />W21-5bR <br />107' TAPER250' <br />250' <br />250' <br />t <br />—R/W <br />R/W R/W R/W <br />R/W R/W <br />R <br />R/W <br />REEN AREA <br />DM <br />GREEN A <br />FOC <br />FOC <br />BIKE LANE <br />~ <br />0 N <br />S MACARTHUR DR (40 MPH) <br />SCOPE OF WORK <br />iO SPLICE ON (08) EXISTING LOCATIONS. <br />LINETYPES <br />R/W <br />DIRT AREA <br />125' <br />RIGHT OF WAY <br />END <br />ROAD WORK <br />G20-2 27510 <br />S MACARTHUR DR, <br />TRACY, <br />A 95377 <br />IMPORTANT NOTICE <br />Section # 4216/4217 of the Government Code requires a <br />Dig Alert Identification Number to be issued before a <br />"Permit to Excavate" will be valid For your Dig Alert I.D. <br />CALL TOLL FREE <br />48 HOURS BEFORE YOU DIG <br />UNDERGROUND SERVICE ALERT <br />1-800-227-2600 <br />DIRT AREA <br />APPROACH <br />SPEED <br />TAPER <br />LENGTH <br />(L)< <br />NO. OF <br />CONES <br />PER TAPER <br />SPACING OF CONES <br />ALONG TAPER <br />(FEET) <br />SIGN SPACING (S) <br />ADVANCE OF TAPER <br />& BETWEEN SIGNS <br />25 MPH <br />125 FT. <br />5 <br />25 FT. <br />100 FT. <br />30 MPH <br />180 FT. <br />7 <br />30 FT. <br />250 FT. <br />35 MPH <br />245 FT. <br />8 <br />35 FT. <br />250 FT. <br />40 MPH <br />320 FT. <br />9 <br />40 FT. <br />250 FT. <br />45 MPH <br />540 FT. <br />13 <br />45 FT. <br />350 FT. <br />50 MPH <br />600 FT. <br />13 <br />50 FT. <br />500 FT. <br />50+ MPH <br />1000 FT. <br />21 <br />55 FT. <br />1000 FT. <br />(a) NOTE— BASED ON 12—FOOT WIDE LANES. THIS <br />COLUMN IS ALSO APPROPRIATE <br />FOR LANE WIDTH LESS THAN 12 FEET. <br />PROJ#: JB1480504 <br />CONSTRUCTION TYPE: TRAFFIC CONTROL PLAN (7 OF 13) <br />SYSTEM: SAN JOAQUIN COUNTY <br />SCALE: <br />N.T.S <br />PlannENG 4 <br />SHEET: 14 OF 21 <br />