My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SP7389 - SP7393
PublicWorks
>
VAULT MAPS
>
Small Plans - SP
>
SP6718 - SP7507
>
SP7389 - SP7393
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/8/2024 11:31:10 AM
Creation date
12/21/2023 4:13:34 PM
Metadata
Fields
Template:
Small Plans - SP
Project
Campbell Avenue Resurfacing
Limits
Escalon City Limits to Magnolia Avenue
Year
2021
Project Engineer
Dan Gambini
Roads Worked
Campbell Ave.
Red Lines
Yes
Project #
221952
Districts
District 4
Supplemental fields
Classification
Record Drawings
Cross Ref
SP7389 - SP7393
Type
Resurfacing
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
L <br />Conform <br />GENERAL NOTES: <br />—3 2'- <br />1) <br />'-1) Val <br />8% TE <br />vOr <br />Co� t <br />I <br />Limits of Clearing and Grubbing and Mailbox Relocation <br />I <br />18'-20' <br />16'-18' Geosynthetic Pavement Ilnterlayer Fabric (Paving Fabric) <br />Match Exist Slope <br />Match Exist Slope <br />RECORD DRAWING <br />GOmm"Oni By <br />NO Chan7p <br />Any Parson Us ft This Drawing shouW Ne <br />All Inf innedon By In The Std a wort <br />2' —1 w 3' <br />Conform <br />TE 8i. V <br />Qr— <br />_ — — 0.25 HMA Overlay <br />Grade Exist Shoulder <br />Variable Depth Exist Roadway_ _ _ _ to place Taper Edge <br />Shoulder BackingL----------------------- <br />TYPICAL SECTION 1' minimum width (Typ) <br />(TYP) <br />Sta 10+00 to Sta 72+34 <br />1. 0.25' HMA Overlay must be placed in two (2) layers of approximately equal thickness with Geosynthetic Pavement Interlayer (Paving Fabric) placed on the existing or prepared <br />surface. <br />2. Placement of HMA Overlay must not begin until the HMA used in Pavement Repair has been in place for a minimum of 18 hours. <br />3. Placement of HMA Driveways must not begin until the HMA used for Mainline Paving has been completed. <br />4. Existing highway and utility facilities must remain in place unless otherwise noted. <br />5. Existing trees, shrubs, fences, mailboxes and other frontage improvements must remain in place unless otherwise noted. <br />6. Existing drainage facilities must remain in place unless otherwise noted. The Contractor must conduct earthwork operations so as not to modify or obstruct the existing drainage. <br />7. All Earthwork, except for final shoulder grading, must be completed prior to placing the final layer of HMA Pavement. No Shoulder Backing material will be deposited or drifted on the <br />final layer of HMA surfacing. Where the shoulder placement exceeds 0.50' in thickness, the Shoulder Backing must be placed in two (2) or more fully compacted layers. <br />8. Shoulder Backing material at all intersection radii must receive Penetration Treatment at 0.25 gallons/square yard. Limits of the Penetration Treatment work must be confined to <br />intersection radii plus fifty feet (50') in each direction or to the intersection. <br />9. The Contractor must obtain all permits and licenses required for the construction and completion of the project, and must perform all work in accordance with the requirements and <br />conditions of all permits and approvals applicable to the project. <br />10. The Contractor will be responsible for adequately scheduling inspection and testing of all facilities constructed under this contract with a minimum 24 hour prior notice to the County. <br />All testing must conform to the Standard Specifications. All re—testing will be paid by the Contractor. <br />11. Prior to commencing any work, it will be the Contractor's responsibility to call 811 and have each utility company locate in the field their main service lines and laterals. The <br />Contractor must notify members of the Underground Service Alert (U.S.A.) 48 hours in advance of performing excavation work by calling the toll free number (1-800-642-2444). <br />12. The Contractor must exercise due caution and carefully preserve survey bench marks, control points, reference points and all survey stakes, and must bear all expenses for <br />replacement and/or errors caused by their unnecessary loss or disturbance. <br />13. The Contractor must field verify all existing highway and utility facilities' locations and depths. It will be the Contractor's sole responsibility to locate and protect all existing <br />highway and utility facilities, so that no damage results to them during the performance of this contract. The Contractor will be required to cooperate with other <br />contractors and utilities and services to the project. Payment for this work will be considered to be included in the various items of work. <br />COUNTY OF SAN JOAQUINNO SCALE TYPICAL SECTION CAMPBELL AVENUE RESURFACING Sheet No. <br />AND GENERAL NOTES (Escalon City Limits to Magnolia Avenue) 2 of 5 <br />DRAWN BY DATE PROJECT ENGINEER DATE CHECKED DATE <br />Danie[Saidana 03/2021 <br />
The URL can be used to link to this page
Your browser does not support the video tag.