My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2023_PS-2300501 thru PS-2301000_ - PS-2300881
PublicWorks
>
- PUBLIC SERVICES
>
PERMITS & DEVELOPMENT
>
Encroachment(EP)/Driveway(DW) Permits
>
2023
>
PS-2300501 thru PS-2301000
>
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2023_PS-2300501 thru PS-2301000_ - PS-2300881
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/8/2024 4:09:46 PM
Creation date
2/8/2024 4:07:19 PM
Metadata
Fields
Template:
Permits_Development
DocName
PS-2300881
Category07
Encroachment(EP)/Driveway(DW) Permits
Year2
2023
Notes2
WS Arch Airport Rd. 145' EO Pock Ln.
Type - Permit Process
Traffic Control
Address
3185 M Street, Merced,CA 95348
Application
Pacific Gas & Electric-Merced
Supplemental fields
Cross Ref
PWP730052
Type (2)
Encroachment Permit (EP)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
THIS JOB WILL BE PG&E SHARED CONSTRUCTION. <br />APPLICANT TO TRENCH, BACKFILL, INSTALL ALL <br />SUBSTRUCTURE PER PG&E INSPECTION. <br />PG&E TO INSTALL ALL DISTRIBUTION AND SERVICE FACILITIES. <br />APPLICANT TO INSTALL GROUND RODS IN PRIMARY ENLOSURES. <br />PG&E TO INSTALL WIRE, CONNECTORS, AND CLAMPS IN ENCLOSURES <br />THIS SKETCH <br />IS INTENDED <br />FOR ELECTRIC CONSTRUCTION <br />ONLY <br />PLEASE SEE <br />JOINT TRENCH <br />COMPOSITE FOR TRENCHING <br />DETAILS. <br />THESE DRAWINGS <br />ARE <br />CONSIDERED <br />PRELIMINARY <br />AND AT RISK, <br />UNLESS STAMPED <br />AND <br />APPROVED <br />BY PG&E AND <br />P.E. <br />Underground Service Alert <br />ORE YO <br />MAXIMUM <br />QEF <br />2-1 /OAL <br />Call: Toll Free <br />GRIP= 1688LBS <br />811 <br />G ~ <br />3-1/OAL <br />Pvqr <br />�c��UND SER�G�. <br />GRIP=1688LBS <br />CALL TWO WORMG <br />DAYS BEFORE YOU DIG <br />PG&E GAS CONFLICT <br />IDENTIFIED FOR THIS PROJECT <br />GAS PLAT: 3005-J7 <br />— — — <br />PG&E GAS FACILITIES <br />IN CONFLICT WITH EXCAVATION AT <br />LOCATION(S) - XX <br />DRAFTER P BROWN <br />PG&E GAS FACILITIES <br />IN PROXIMITY WITH EXCAVATION AT <br />LOCATION(S) - ALL <br />ENVIRONMENTAL ISSUES <br />LINONE APPARENT <br />(IF PROJECT DESIGN CHANGES, CONTACT ADE) <br />❑ BASED ON APPLICANT/DEVELOPER-SUPPLIED PLANS <br />Ll PERMITS U TAILBOARD ❑ OTHER <br />❑ APPLICANT DESIGN/RESPONSIBILITY <br />(CHECK PERMITS BOX IF PERMIT CONDITIONS APPLY <br />TO PG&E ACTIONS.) <br />SIGNATURE <br />VOV / A \ <br />I <br />I <br />I <br />I I <br />I I <br />I <br />I <br />I <br />� 3 <br />2 O <br />O <br />a � > <br />I 3-4/OAL 12KV REMOVE Y <br />w I181' CABLE �1 J-5265 N J <br />ABANDON ao 0O <br />O 30 OF 4 <br />J-1864 toI o <br />I PO <br />VI <br />T-9252 <br />I 75KVA-30 <br />> ABANDON�� 480V <br />N O <br />� � I 60 OF 4 <br />00J I <br />10 <br />�� I1 <br />,I <br />6 O <br />O <br />2-1 /OAL 12KV _ 25KVA 99 <br />\_ CABLE _ 0 <br />0 <br />POCK LANE <br />0 <br />a_ <br />a <br />< <br />PRIMARY <br />CONDUCTOR <br />MAXIMUM <br />PULLING TENSIONS <br />2-1 /OAL <br />IN 4" <br />GRIP= 1688LBS <br />PULLING <br />EYE=1688LBS <br />3-1/OAL <br />IN 4" <br />GRIP=1688LBS <br />PULLING <br />EYE=1688LBS <br />CABLE PULLING DATA <br />2O LOC 1 TO LOC 3 <br />USE 0 -GAL & 2 -FRONT END PKS. <br />EST. PULL 436LBS. <br />ACTUAL PULL ............ LBS. <br />FOREMAN'S INITIALS.......... <br />4O LOC 5 TO LOC 3 <br />USE 0 -GAL & 1 -FRONT END PKS. <br />EST. PULL 64LBS. <br />ACTUAL PULL ............ LBS. <br />FOREMAN'S INITIALS.......... <br />O LOC 7 TO LOC 3 <br />USE 0 -GAL & 2 -FRONT END PKS. <br />EST. PULL 316LBS. <br />ACTUAL PULL ............ LBS. <br />FOREMAN'S INITIALS.......... <br />O <br />N i N J-7775 <br />36" <br />o I 36" <br />TO: J-1864 031 P3 <br />I <br />I <br />0 <br />EEI <br />o <br />I <br />4' TO. <br />N I N N T\ <br />I 2� <br />I <br />27' 0) a <br />rn <br />w <br />0) <br />of U H J <br />it OW <br />Z p <br />V) <br />SCALE: 1 "=5' <br />5' 0' S' 10' <br />/ A \ <br />I <br />I <br />I <br />I I <br />I I <br />I <br />I <br />I <br />2 <br />I TIE INTO <br />TIE INTO <br />a I EXIST 4" EXIST 4" <br />w PULL 1 3 NOTE: <br />P5�P5�P5 1 APPLICANT TO TIE <br />I 80'/195' J-7775 I L, 20'/34' INTO EXISTING <br />80 EXIST P3 a CONDUIT OUTSIDE <br />O4 OF THE PAD. <br />J-1864 � I 2 DEG <br />O <br />I � T-9252 <br />TIE INTOE 75KVA-30 <br />> I EXIST 4" 480V <br />Y <br />0010 <br />J I <br />,I <br />O O <br />35'/313' T-49999 <br />245' EXIST 25KVA <br />— � 4 P4 —P4 P4 —P4 —P4 <br />-- o <br />POCK LANE <br />0 <br />a_ <br />a <br />LEGEND <br />INSTALL <br />DESCRIPTION <br />P2 P2 <br />PRIMARY CABLE - 2-1/OAL EPR ENCAP IN NEW 1-4" CONDUIT <br />P3 P3 <br />PRIMARY CABLE - 3-1/OAL EPR ENCAP IN NEW 1-4" CONDUIT <br />P4 P4 <br />PRIMARY CABLE — 2-1/OAL EPR ENCAP IN EXISTING 1-4" CONDUIT <br />P5 P5 <br />PRIMARY CABLE — 3-1/OAL EPR ENCAP IN EXISTING 1-4" CONDUIT <br />EXISTING <br />DESCRIPTION <br />SCALE AS SHOWN <br />3 PHASE PRIMARY CABLE/CONDUCTOR - SIZE AS SHOWN <br />1 PHASE PRIMARY CABLE/CONDUCTOR - SIZE AS SHOWN <br />— — — <br />VACANT CONDUIT (PRIMARY) - SIZE AS SHOWN <br />INSTALL <br />EXISTING DESCRIPTION <br />DRAFTER P BROWN <br />© 4' x 6'6" x 5' PRIMARY ENCLOSURE <br />(EXTERNAL DIMENSION 5'W X 7'6"L X VD) <br />® PM TRANSFORMER, DF—LB, SIZE AS SHOWN <br />OSUBSURFACE TRANSFORMER — SIZE AS SHOWN <br />PJ <br />PADMOUNT J -BOX, 3 WIRE - 4 WAY <br />RM <br />PG&E APPLICANT DESIGN APPROVAL <br />PG&E Plan Check does not release the Applicant from <br />responsibility to conStruCt the faculties ar,GOrd Ing t0 PG&E <br />Standards. lrw tho event of a conflict dUring construction, <br />PG&E Standards talo precedence. <br />LICctric AIDE: j0sh will Q65k honel 559-347-52-71 <br />Approval S1gn0tur0-. — <br />2/13/2023 <br />Date. -- <br />00 <br />REVISION <br />00 <br />our website <br /># L P E LopesUDS.com <br />UTILITY DESIGN SERVICES <br />1821 N. Langley Ave. Office (559) 575-8221 <br />g Y <br />Clovis, California 93619 Cell (559) 760-9464 <br />AIRPARK 599 <br />ARCH -AIRPORT RD & POCK LN <br />JUNCTION RELOCATION <br />FOR: CATELLUS DEVELOPMENT COOPERATION <br />STOCKTON CALIFORNIA <br />Call 811 <br />� � <br />�" � <br />� �. <br />�"D �"� <br />ELECTRIC CONSTRUCTION SKETCH <br />I <br />� M <br />DATE 1/6/2023 <br />SHEET <br />El <br />of El SHEETS <br />a <br />SCALE AS SHOWN <br />AVisit <br />a <br />DESIGNER Cliff Lopes <br />p <br />DRAFTER P BROWN <br />o�w <br />r <br />00 <br />REVISION <br />00 <br />our website <br /># L P E LopesUDS.com <br />UTILITY DESIGN SERVICES <br />1821 N. Langley Ave. Office (559) 575-8221 <br />g Y <br />Clovis, California 93619 Cell (559) 760-9464 <br />AIRPARK 599 <br />ARCH -AIRPORT RD & POCK LN <br />JUNCTION RELOCATION <br />FOR: CATELLUS DEVELOPMENT COOPERATION <br />STOCKTON CALIFORNIA <br />Call 811 <br />� � <br />�" � <br />� �. <br />�"D �"� <br />ENCLOSURE DETAIL IS INTENDED FOR <br />CONDUIT ENTRANCE INFORMATION ONLY. <br />PLEASE REFER TO JOINT TRENCH DRAWING <br />FOR EXACT LOCATION IN REFERENCE TO <br />CURB, SIDEWALK, PUE, AND P/L. <br />> <br />Y <br />N <br />J 00 <br />OI <br />O to <br />EXISTING <br />J-1864 <br />4' X 6'-6"X 5'D IVT. BOX <br />(EXTERNAL DIMENSION 5'W X 7'61 X 5'6"D) <br />LfP E S <br />U . iii it D SIGN S WICES <br />APPROVED FOR SUBMITTAL <br />CLI EEORD LOPES <br />QUALIFIED APPLICANT DESIGN ENGINEER <br />RAPTOR ZONE (YES) <br />WEBER 1108 <br />MAP:AU 123-D21 <br />INS DIST:B <br />CLIMATE ZONES <br />S.S.D. = XXXX <br />VOLT CLASS:2 <br />LOADING DIST:SI <br />LIGHTNING DIST:3 <br />NON CORROSIVE AREA <br />FIRE TIER AREA 1 <br />LIGHT SNOW LOADING <br />T <br />E11965 m <br />* EXP. 9/30/23 <br />s�q� F�FCTR��P <br />FpFCAo <br />SCALE: 1 "=40' SCALE <br />40' 0' 40' 80' <br />NO. <br />REVISION <br />BY <br />our website <br /># L P E LopesUDS.com <br />UTILITY DESIGN SERVICES <br />1821 N. Langley Ave. Office (559) 575-8221 <br />g Y <br />Clovis, California 93619 Cell (559) 760-9464 <br />AIRPARK 599 <br />ARCH -AIRPORT RD & POCK LN <br />JUNCTION RELOCATION <br />FOR: CATELLUS DEVELOPMENT COOPERATION <br />STOCKTON CALIFORNIA <br />Call 811 <br />� � <br />�" � <br />� �. <br />�"D �"� <br />ELECTRIC CONSTRUCTION SKETCH <br />RULE WRO <br />PM 35392289 <br />NOT 122887230 <br />DATE 1/6/2023 <br />SHEET <br />El <br />of El SHEETS <br />SCALE AS SHOWN <br />AVisit <br />DESIGNER Cliff Lopes <br />p <br />DRAFTER P BROWN <br />boa 21-213 <br />
The URL can be used to link to this page
Your browser does not support the video tag.