My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2024_PS-2400000 thru PS-2400500_ - PS-2400357
PublicWorks
>
- PUBLIC SERVICES
>
PERMITS & DEVELOPMENT
>
Encroachment(EP)/Driveway(DW) Permits
>
2024
>
PS-2400000 thru PS-2400500
>
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2024_PS-2400000 thru PS-2400500_ - PS-2400357
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2024 9:04:26 AM
Creation date
2/9/2024 9:02:21 AM
Metadata
Fields
Template:
Permits_Development
DocName
PS-2400357
Category07
Encroachment(EP)/Driveway(DW) Permits
Year2
2024
Notes2
S/S of Harding Way 40' E/O Rhode Island Ave.
Type - Permit Process
Traffic Control Devices
Address
PO Box 930, Stockton,CA 95201
Application
Pacific Gas & Electric-Stockton
Supplemental fields
Cross Ref
PWP730052
Type (2)
Encroachment Permit (EP)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
©1 <br />M <br />=I <br />am I <br />DI <br />2 � 3 <br />VICINITY MAP <br />'vorVieast <br />l 0i? I i:L 11tV Center <br />O <br />LaCon-rerciaNft <br />_) Commissary T <br />Stockton Trailer <br />Manufacturing <br />1. DEACTIVATE THE 2001 DWA-ND LOCATED ON E HARDING WAY & N RHODE ISLAND AVE IN STOCKTON. <br />2. REMOVE ALL CATHODIC PROTECTION EQUIPMENT OFF THE EXISTING UTILITY POLE. <br />3. REMOVE EXISTING ELECTRIC SERVICE. <br />1. PRIOR TO STARTING WORK, CONTACT LOCAL AREA CORROSION SUPERVISOR REGARDING CATHODIC PROTECTION REQUIREMENTS AND I&R SUPERVISOR REGARDING ANY SHUTDOWN, AI <br />OR TIE-IN OF ANY MAINS WHICH MAY AFFECT ANY DISTRICT REGULATOR STATION. <br />2. ALL STEEL TIE-INS, CUT OFFS AND CAPPING OF CAST IRON AND STEEL MAIN PER A-36 AND C-37. <br />3. ALL PLASTIC CONNECTIONS TO BE PERFORMED IN ACCORDANCE WITH THE APPROPRIATE PROCEDURES LISTED IN TD -41705. <br />4. UNLESS OTHERWISE NOTED, CONSTRUCTION TO REFERENCE TD -4125P-09 TO DETERMINE EXISTING STEEL PIPE SPECS. <br />5. ALL ARC WELDING IS TO BE PERFORMED IN ACCORDANCE WITH THE GAS WELDING CONTROL MANUAL TD -4160M. REFER TO TD-416OP-20 FOR GENERAL WELDING REQUIREMENTS. <br />4 <br />20. ALL EXCAVATION TO BE PERFORMED PER TD -5811M, TD -5811P-301, TD -5811P-105, TD -4412P-05, AND TD -4621S. STANDBY REQUIRED IF EXCAVATING WITHIN 5' OF A CRITICAL FACILITY, <br />BORING ACTIVITY THAT CROSSES OR THAT PARALLELS WITHIN 10' OF A CRITICAL FACILITY. CONTACT THE CONSTRUCTION SUPERVISOR. <br />21. NOTIFY SCHOOLS AND HOSPITALS WITHIN 5001 OF PROPOSED EXCAVATION FOR GAS FACILITIES A MINIMUM OF 3 DAYS PRIOR TO DIGGING PER AB 1937. <br />22. ANY PIPE REPLACEMENT VIA SPLITTING TO BE DONE PER TD -4634P-01 & TD -4634P-02. <br />23. CAMERA INSPECTION (PRE/POST) FOR TRENCHLESS METHODS TO BE PERFORMED PER TD -4632P-01. <br />24. WARNING TAPE IS TO BE INSTALLED IN OPEN TRENCH INSTALLATION OVER GAS PIPELINES IN BOTH TRANSMISSION AND DISTRIBUTION FACILITIES. THIS INCLUDES BELL HOLES, EXCAVATIONS FOR <br />REPAIR PURPOSES AND RISER REPLACEMENTS PER GS&S L-16. <br />25. DEVIATIONS FROM THIS APPROVED DESIGN SHALL BE PROCESSED IN ACCORDANCE WITH TD -4014P-05 AFIELD DESIGN CHANGE PROCESS FOR DISTRIBUTION LINES AND DUAL -ASSET FACILITIES." <br />26. ALL TRENCH SPOILS AND BACKFILL MUST BE USED OR DISPOSED WITH AS REQUIRED BY PG&E SPECIFICATIONS AND ANY LOCAL CITY, COUNTY OR STATE REQUIREMENTS. <br />27. PG&E TO INSTALL/RESTORE TEMPORARY AND/OR PERMANENT PAVING IN ACCORDANCE WITH PG&E SPECIFICATIONS AND ANY LOCAL CITY, COUNTY OR STATE REQUIREMENTS. <br />28. STAND-BY REQUIREMENTS MUST BE IN ACCORDANCE WITH TD -5811P-301, TD -5811P-105 & TD -58118-005 WITH WORKING NEAR ANY CRITICAL FACILITIES. <br />29. MONUMENT PRESERVATION AS REQUIRED BY THE PROFESSIONAL LAND SURVEYORS' ACT (BUSINESS AND PROFESSION CODE SUB -SECTION 8700-8805) SECTION 8771; PRIOR TO THE START OF <br />CONSTRUCTION, ALL SURVEY MONUMENTS, WITHIN THE PROJECT LIMITS THAT HAVE THE POSSIBILITY OF BEING DAMAGED OR DESTROYED DURING CONSTRUCTION, MUST BE LOCATED, AND <br />REFERENCED BY A LICENSED LAND SURVEYOR, AND A CORNER OF RECORD OR RECORD OF SURVEY SHALL BE FILED WITH THE COUNTY SURVEYOR. IF ANY OF THESE SURVEY MONUMENTS ARE <br />DESTROYED, DAMAGED OR COVERED OVER DURING CONSTRUCTION, A NEW MONUMENT AND MONUMENT BOX MUST THEN BE SET IN ITS PLACE, AT THE ORIGINAL LOCATION, BY A LICENSED <br />LAND SURVEYOR, AND ANOTHER CORNER OF RECORD OR RECORD OF SURVEY FILED WITH THE COUNTY SURVEYOR. <br />30. CONSTRUCTION MEANS AND METHODS MAY DEVIATE PER FIELD VERIFIED CONDITIONS IN ACCORDANCE WITH LOCAL JURISDICTION REQUIREMENTS. IF THERE ARE ANY QUESTIONS, CONTACT <br />RESPONSIBLE ENGINEER. <br />5 <br />6 <br />7 <br />DEEP WELL ANODE DEACTIVATION <br />E HARD NG WAY & N RHODE ISLAND AVE <br />STOCKTON, CA <br />PLAN VIEW <br />�Z�p9 <br />q <br />3 4 1955 <br />s <br />q S <br />Z <br />G <br />q <br />P <br />SNP /� 15 1-11D <br />s <br />1955 1pp <br />SNPAM SNP <br />/ SNP <br />/ SNP Z <br />/ SNP <br />0 2 <br />i <br />o 1�12a354 <br />C2 SCALE: N.T.S. <br />8 � 9 <br />LEGEND <br />SHP SHP EXISTING GAS MAIN (SIZE NOTED) <br />- - - - - - - GROUND WIRES (INSTALL) <br />- - - - - - - ANODE WIRES (INSTALL) <br />- - - - CATHODE WIRES (INSTALL) <br />! DEEP WELL ANODE (INSTALL) <br />T RECTIFIER (INSTALL) <br />ccgi GROUND ROD (INSTALL) <br />0 DEEP WELL ANODE (EXISTING) <br />T RECTIFIER (EXISTING) <br />© GROUND ROD (EXISTING) <br />0 PG&E POLE (EXISTING) <br />, <br />CORROSION <br />DAVID <br />�• I, •; <br />CORROSIONSPECIALIST 697-4422 <br />■ qSENIOR <br />/ ■ <br />DISTRIBUTION ENGINEER (925) 658-0845 <br />'PLANNING ENGINEER ,/ 942-1626 • . <br />ADAM CONTRERASri569-2423 <br />WORKINGO• <br />GC FIELD ENGINEER <br />NOTIFIED U.S.A. <br />DATE: <br />TICKET # <br />BY: <br />CATHODIC PROTECTION IN WORK AREA <br />ATTENTION FOREMAN: <br />NOTIFY THE CORROSION DEPT. AT <br />(209) 603-9843, 48 HOURS PRIOR TO <br />START OF WORK. <br />ATTENTION FOREMAN <br />PRIOR TO STARTING JOB, CONSULT AREA <br />CORROSION MECHANIC FOR LOCATING WIRE <br />INSTALLATION AND CATHODIC PROTECTION <br />REQUIREMENTS <br />Installation Tested or Inspected <br />and Noted on Drawing. <br />All Corrosion Levels Satisfactory per <br />PG&E Gas Utility Standard TD -41815. <br />Qualified Employee Date <br />Corrosion mechanic's signature is required when a <br />CPA boundary is within the scope of the project <br />re <br />cc rl) U -)oto <br />a0 N r` I`) N <br />O N00 <br />C:) <br />cn <br />00 M Ln ^ N <br />N CO 61 U') --d- <br />M In --d- N M N N <br />O <br />N <br />LL- <br />CD� O m N <br />U-) <br />O <br />Z <br />J <br />6 � W <br />Cn O N <br />0 d7 <br />W W W LO <br />N <br />¢z�LO <br />" <br />JL.3 N <br />Z ¢¢ '� <br />Q Y ZUj <br />O ¢p u J <br />6: F= <br />c~n c= W H O M <br />W Q N I= I d I= d <br />i <br />z � <br />Q w <br />0 w <br />0 0 0 <br />C -) <br />z C)� - <br />z rn <br />Q Q Q do <br />ci- z �� <br />woo 4 <br />CQ <br />oQv(S 93 <br />Q CD o Y <br />Q <br />Q � z • <br />U Z � V) <br />11 C.D <br />C- z <br />Q w <br />0- <br />Z <br />0 <br />In <br />Z <br />0 <br />U <br />0 <br />0 <br />W <br />= Q <br />W O z <br />� Q � <br />C/) > cn <br />F- <br />• U W <br />w z <br />A ozo <br />0 <br />Or, Q 48 o <br />- <br />I <br />J 0 B DATA zW <br />O 3:: � <br />CITY: STOCKTON U w z <br />COUNTY: SAN JOAQUINLLJ <br />PLAT: 3005-05 Cly <br />CPA: 3005-14B C w <br />TBA: X-02 <br />MAOP: 12° W.C. <br />NOP: 8.5° W.C. <br />APD: <br />EZ: 16 -ST -07-B Z <br />0 <br />4 3 2 1 INCH 0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.