Laserfiche WebLink
APPROACH <br />SPEED <br />TAPER <br />LENGTH <br />(L)s <br />No. OF <br />CONES <br />PER TAPER <br />SPACING OF CONES <br />ALONG TAPER <br />(FEET) <br />SIGN SPACING (S) <br />ADVANCE OF TAPER <br />& BETWEEN SIGNS <br />25 MPH <br />125 FT. <br />6 <br />25 FT. <br />100 FT. <br />30 MPH <br />180 FT. <br />7 <br />30 FT. <br />250 FT. <br />35 MPH <br />245 FT. <br />8 <br />35 FT. <br />250 FT. <br />40 MPH <br />320 FT. <br />9 <br />40 FL <br />250 FT. <br />45 MPH <br />540 FT. <br />13 <br />45 FT. <br />350 FT. <br />50 MPH <br />600 FT. <br />13 <br />50 FT. <br />500 FT. <br />50+ MPH <br />1000 FT. <br />21 <br />55 FT. <br />1000 FT. <br />(*) NOTE- BASED ON 12 -FOOT WIDE LANES. THIS <br />COLUMN IS ALSO APPROPRIATE <br />FOR LANE WIDTH LESS THAN 12 FEET. <br />EXISTING POLE <br />SPLICE AND ACTIVATION <br />END <br />ROAD WORK <br />G20-2 50 <br />ROAD <br />WORK <br />W20-1 <br />W20-4 <br />R/W. P U E ACQUISTION NOTE <br />CONTRACTOR TO VERIFY RIGHT OF WAY, <br />PUBLIC UTILITY EASEMENT AND/OR PUBLIC <br />SERVICE EASEMENT ACQUISTION WITH THE <br />APPLICANT PRIOR TO CONSTRUCTION WITHIN <br />AREAS OF QUESTION. <br />Cone Footage = 150' <br />C9A(CA) <br />THIS IS AN COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIAL <br />DESIGN: N.PE REV DESCRIPTION DATE <br />DRAWN BY: AT.PE 0 ISSUE FOR PERMIT 01/17/2024 <br />DRAWN BY: <br />APPROVED: <br />APPROVED: <br />1227 <br />E ACACIA ST, <br />STOCKTON, <br />CA 95205 <br />PROVIDE 72 HOUR NOTICE AT E <br />ALL PARKING SPACES PRIOR TO <PREEBPAI <br />USE. TO <br />TOI <br />INSTALL TEMPORARY NO PARKING SIGNS <br />(If Required) <br />54 <br />50• 150 <br />1 RAN <br />7 A, <br />1 <br />Q 91 m END <br />ROAD'-p <br />� <br />Of ROAD WORK <br />AHEAD UD1 L�. /'b' 1 <br />_ G20-2 <br />W20-1 u1 p 1 v s m <br />N A 1 amm <br />>n <br />z — z m <br />f <br />ONE LANE 1 L� T 100 <br />ROAD A <br />\ AHEADf 0 1� <br />3A(CA) 1 <br />/ W20-4 N 1 1 PON <br />o. SIDEWA1 <br />FOC PA <br />m0 <br />100' � �► <br />A� <br />i► <br />PARKING <br />SI— • _ 1 N <br />® • PARK <br />•• EWA <br />SIDW <br />R/ <br />LK ♦ 1 t t T <br />R/ftEEN AREA 1 <br />� D W f <br />WALK o <br />SIDE NAREA RpN N 1 <br />u• v � <br />m <br />FLAGGERS SHALL BE USED FOR END1 O Y 1 z > <br />ad <br />ONE—WAY TRAFFIC CONTROL. ROAD WORK m� 1� >4— o <br />> >� W �� <br />G20-2 m x 1J11� 0 <br />1228 <br />E ACACIA ST, <br />STOCKTON, <br />CA 95205eG <br />1 W <br />SCOPE OF WORKCs <br />1 m <br />o m <br />z <br />lO SPLICE ON (6) EXISTING LOCATIONS. m`� 1 n n <br />A � 1 I ROW x <br />7 A. <br />a <br />LINETYPES A <br />R/W RIGHT OF WAY 1 1 54' <br />IMPORTANT NOTICE <br />Section # 4216/4217 of the Government Code requires a <br />Dig Alert Identification Number to be issued before a <br />"Permit to Excavate" will be valid For your Dig Alert I.D. <br />CALL TOLL FREE <br />48 HOURS BEFORE YOU DIG <br />UNDERGROUND SERVICE ALERT <br />1-800-227-2600 <br />"NO LANE CLOSURE <br />R/"ARE D/W <br />BE <br />SIDEWALK r�I <br />5 L <br />BETWEEN 6:00 AM <br />p,CACIN <br />N <br />X25 �H� <br />BETWEEN 3:30 PM <br />[SW <br />6:30 <br />GREEN AREA R/ i 100 <br />OTHER TIMES, AT LEAST <br />R/W 1p0' <br />R/W 100 <br />TRAFFIC SHALL BE <br />ROAD <br />WORK <br />W20-1 <br />W20-4 <br />R/W. P U E ACQUISTION NOTE <br />CONTRACTOR TO VERIFY RIGHT OF WAY, <br />PUBLIC UTILITY EASEMENT AND/OR PUBLIC <br />SERVICE EASEMENT ACQUISTION WITH THE <br />APPLICANT PRIOR TO CONSTRUCTION WITHIN <br />AREAS OF QUESTION. <br />Cone Footage = 150' <br />C9A(CA) <br />THIS IS AN COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIAL <br />DESIGN: N.PE REV DESCRIPTION DATE <br />DRAWN BY: AT.PE 0 ISSUE FOR PERMIT 01/17/2024 <br />DRAWN BY: <br />APPROVED: <br />APPROVED: <br />1227 <br />E ACACIA ST, <br />STOCKTON, <br />CA 95205 <br />PROVIDE 72 HOUR NOTICE AT E <br />ALL PARKING SPACES PRIOR TO <PREEBPAI <br />USE. TO <br />TOI <br />INSTALL TEMPORARY NO PARKING SIGNS <br />(If Required) <br />54 <br />50• 150 <br />1 RAN <br />7 A, <br />1 <br />Q 91 m END <br />ROAD'-p <br />� <br />Of ROAD WORK <br />AHEAD UD1 L�. /'b' 1 <br />_ G20-2 <br />W20-1 u1 p 1 v s m <br />N A 1 amm <br />>n <br />z — z m <br />f <br />ONE LANE 1 L� T 100 <br />ROAD A <br />\ AHEADf 0 1� <br />3A(CA) 1 <br />/ W20-4 N 1 1 PON <br />o. SIDEWA1 <br />FOC PA <br />m0 <br />100' � �► <br />A� <br />i► <br />PARKING <br />SI— • _ 1 N <br />® • PARK <br />•• EWA <br />SIDW <br />R/ <br />LK ♦ 1 t t T <br />R/ftEEN AREA 1 <br />� D W f <br />WALK o <br />SIDE NAREA RpN N 1 <br />u• v � <br />m <br />FLAGGERS SHALL BE USED FOR END1 O Y 1 z > <br />ad <br />ONE—WAY TRAFFIC CONTROL. ROAD WORK m� 1� >4— o <br />> >� W �� <br />G20-2 m x 1J11� 0 <br />1228 <br />E ACACIA ST, <br />STOCKTON, <br />CA 95205eG <br />1 W <br />SCOPE OF WORKCs <br />1 m <br />o m <br />z <br />lO SPLICE ON (6) EXISTING LOCATIONS. m`� 1 n n <br />A � 1 I ROW x <br />7 A. <br />a <br />LINETYPES A <br />R/W RIGHT OF WAY 1 1 54' <br />IMPORTANT NOTICE <br />Section # 4216/4217 of the Government Code requires a <br />Dig Alert Identification Number to be issued before a <br />"Permit to Excavate" will be valid For your Dig Alert I.D. <br />CALL TOLL FREE <br />48 HOURS BEFORE YOU DIG <br />UNDERGROUND SERVICE ALERT <br />1-800-227-2600 <br />"NO LANE CLOSURE <br />WILL <br />BE <br />ALLOWED <br />BETWEEN 6:00 AM <br />AND <br />9:00 <br />AM AND <br />BETWEEN 3:30 PM <br />AND <br />6:30 <br />PM. AT <br />OTHER TIMES, AT LEAST <br />ONE <br />LANE OF <br />TRAFFIC SHALL BE <br />KEPT <br />OPEN <br />TO THE <br />GENERAL PUBLIC.,, <br />Flashing Arrow Sign (Where Required) <br />ROAD <br />WORK <br />W20-4 <br />100 <br />W20-1 <br />Ep,CA Ip' 5T p <br />X25 E" D/W <br />SIDE ca o / <br />D/W <br />W20-4 <br />501 <br />END <br />ROAD WORK <br />G20-2 <br />PROJ#: JB1680957 <br />CONSTRUCTION TYPE: TRAFFIC CONTROL PLAN (3 OF 6) <br />SYSTEM: STOCKTON <br />PlannENG 4 <br />SHEET: 5 OF 9 <br />LEGEND <br />• <br />Traffic Cone or Delineator <br />i <br />Sign <br />�� <br />Direction of Travel <br />DEAD <br />( Not a pavement marking ) <br />Flashing Arrow Sign (Where Required) <br />—1 <br />Refer to Page 7 of Caltrans manual <br />Type A, Type I , or Type H . <br />Y <br />High Level Warning Device (Flogtree) <br />Barricade (For Excavation Only) <br />Refer to Page 12 of Caltrans manual <br />to select for Details on <br />Type I , Type H , or Type ID . <br />Flogger <br />SCALE: N.T.S <br />PROJ#: JB1680957 <br />CONSTRUCTION TYPE: TRAFFIC CONTROL PLAN (3 OF 6) <br />SYSTEM: STOCKTON <br />PlannENG 4 <br />SHEET: 5 OF 9 <br />