My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2024_PS-2400501 thru PS-2401000_ - PS-2400872
PublicWorks
>
- PUBLIC SERVICES
>
PERMITS & DEVELOPMENT
>
Encroachment(EP)/Driveway(DW) Permits
>
2024
>
PS-2400501 thru PS-2401000
>
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2024_PS-2400501 thru PS-2401000_ - PS-2400872
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/26/2024 1:27:53 PM
Creation date
3/26/2024 1:22:39 PM
Metadata
Fields
Template:
Permits_Development
DocName
PS-2400872
Category07
Encroachment(EP)/Driveway(DW) Permits
Year2
2024
Notes2
Both Sides of Broadway Ave. 1 Mile S/O Waterloo Rd.
Type - Permit Process
Aerial Work
Address
4125 Northgate Blvd., Sacramento,CA 95834
Application
Tak Communications
Supplemental fields
Cross Ref
PWP7110005
Type (2)
Encroachment Permit (EP)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
GENERAL NOTES <br />SYMBOLS <br />LINETYPES <br />• ALL GENERAL NOTES SHALL APPLY TO ALL DRAWINGS, PLANS AND DETAILS. <br />NEW COMCAST POWER SUPPLY <br />TRANSFORMER <br />PROPOSED TRENCH/BORE ROUTE <br />® <br />NEW COMCAST LOW PROFILE <br />PROPOSED OVERLASH ROUTE <br />• CONTRACTOR SHALL NOTIFY UNDERGROUND SERVICE ALERT (USA), AT LEAST 48 <br />��• <br />STREETLIGHT <br />PROPOSED OVERPULL ROUTE <br />• HOURS (AND NOT MORE THAN 14 DAYS) PRIOR TO THE START OF CONSTRUCTION BY <br />m 9 <br />POWER SUPPLY W/ METER <br />cAry cAry <br />cAry <br />EXISTING COMCAST ROUTE <br />CALLING (800) 227-2600. <br />0 <br />NEW COMCAST VAU LT <br />TRAFFIC SIGNAL COMBINATION <br />r r <br />r <br />EXISTING TELEPHONE SYSTEM <br />• CONTRACTOR SHALL POTHOLE/HAND DIG AND VERIFY ALL UNDERGROUND UTILITIES <br />i..i <br />FIRE HYDRANT <br />—CATV—CATV—CATV—EXISTING <br />TV SYSTEM <br />NEW COMCAST PEDESTAL <br />PRIOR TO THE START OF CONSTRUCTION. ALL UTILITY LOCATIONS ON PLANS ARE <br />p. <br />MONUMENT <br />— cns— cns— cns— <br />cAS— <br />EXISTING GAS SYSTEM <br />APPROXIMATE, CONTRACTOR MUST VERIFY. CONTRACTOR SHALL VERIFY ALL FOOTAGES <br />® <br />BORE PIT <br />e e <br />e <br />EXISTING ELECTRICAL SYSTEM <br />® <br />CATCH BASIN <br />ON SITE, PRIOR TO THE START OF <br />POTHOLE <br />EXISTING JOINT TRENCH <br />• CONSTRUCTION. ALL DIMENSIONS SHOWN ON PLANS ARE APPROXIMATE. CONTRACTOR <br />so <br />STORM DRAIN MANHOLE <br />iaa iaa <br />iaa <br />EXISTING IRRIGATION SYSTEM <br />NEW RISER ATTACHED TO POLE <br />SHALL KEEP A COPY OF APPROVED PLANS) AND PERMIT(S) AT THE <br />© <br />WATER MANHOLE <br />—SS—SS—SS—SS—SS— <br />EXISTING SANITARY SEWER <br />® <br />EXISTING POLE <br />SD—SD—SD— <br />EXISTING STORM DRAIN <br />• JOB SITE AT ALL TIMES AND PRESENT IT TO AN AUTHORIZED AGENT OF THE CITY/COUNTY <br />ss <br />SANITARY SEWER MANHOLE <br />AND/OR LAW ENFORCEMENT U PON REQUEST. <br />Is] <br />EXISTING COMCAST VAULT <br />—"'"'"'"'"'— <br />EXISTING WATER LINE <br />co <br />SEWER CLEAN OUT <br />x x x <br />x <br />EXISTING FENCELINE <br />• CONTRACTOR SHALL ENSURE THAT ANY EXISTING FACILITIES DAMAGED OR REMOVED <br />® <br />EXISTING COMCAST PEDESTAL <br />aL aL <br />aL <br />ROADWAYCENTER LINE <br />SHALL BE REPLACED IN KIND OR BETTER, INCLUDING BUT NOT LIMITED TO REPLACING <br />Q <br />ELECTRIC MANHOLE <br />PROPERTY LINE <br />o <br />EXISTING IRRIGATION VAULT <br />EXISTING STRIPING AND REMOVING UNNECESSARY "USA" MARKINGS. CONTRACTOR <br />Q <br />UNIDENTIFIED MANHOLE <br />— — — — <br />— — <br />RIGHT OF WAY LINE <br />SHALL WORK ONLY DURING APPROVED HOURS, UNLESS OTHERWISE <br />D <br />EXISTING UTILITY VAULT/PEDESTAL <br />® <br />WATER METER <br />ABBREVIATIONS <br />• APPROVED IN WRITING BY THE"CITY/COUNTY ENGINEER." <br />I>< <br />GASNVATER VALVE <br />• CONTRACTOR SHALL PERFORM ALL WORK AND TRAFFIC CONTROL IN ACCORDANCE WITH <br />c0 <br />GAS METER <br />COMCAST COMCAST <br />PL <br />PROPERTY LINE <br />TREE/BUSHES <br />C/L CENTER LINE <br />PILE <br />PUBLIC UTILITY EASEMENT <br />THE CIN/COUNTY AND STATE OF CALIFORNIA STANDARD PLANS AND SPECIFICATIONS, <br />(E) EXISTING <br />RNV <br />RIGHT OF WAY <br />FOC FACE OF CURB <br />SD <br />EXISTING STORM DRAIN <br />AND CURRENT CALIFORNIA DEPARTMENT OF TRANSPORTATION"MANUAL OF TRAFFIC <br />MIN MINIMUM <br />SS <br />EXISTING SANITARY SEWER <br />CONTROLS AND MAINTENANCE OF HAZARD ZONE" AND "MANUAL OF WARNING SIGNS, <br />MAX MAXIMUM <br />T <br />EXISTING TELEPHONE <br />DWY DRIVEWAY <br />W <br />EXISTING WATER <br />LIGHTS AND DEVICES" FOR USE IN PERFORMANCE OF WORK UPON HIGHWAYS. FLASHING <br />(N) NEW <br />E <br />EXISTING ELECTRIC <br />ARROW SIGNS SHALL BE REQUIRED FOR ALL LANE CLOSURES. <br />(T) TEMPORARY <br />G <br />EXISTING GAS <br />CNDT CONDUIT <br />EOP <br />EDGE OF PAVEMENT <br />• CONTRACTOR SHALL ENSURE ALL WORK PERFORMED IS IN ACCORDANCE WITH <br />BOW BACK OF WALK <br />LOG <br />LIP OF GUTTER <br />REGULATIONS AND STANDARDS SET BY ANY AND ALL REGULATORY AGENCIES HAVING <br />JURISDICTION AT THIS WORK SITE, INCLUDING BUT NOT LIMITED TO THE STATE OF <br />CALIFORNIA PUBLIC UTILITY COMMISSION (CPUC), THE STATE OF CALIFORNIA <br />OCCUPATIONAL SAFETY AND HEALTH ACT (CAL OSHA), THE COUNTY AND THE CITY. <br />• ALL WORK SHALL BE ACCESSIBLE AND SUBJECT TO INSPECTION BY THE CITY/COUNTY <br />ENGINEER AND/OR AN AUTHORIZED AGENT OF COMCAST. <br />• CONTRACTOR SHALL NOTIFY BUSINESS ESTABLISHMENTS/OWNERS AFFECTED BYTHE <br />WORKAT LEAST 72 HOURS IN ADVANCE OF CONSTRUCTION. <br />• CONTRACTOR SHALL NOTIFY THE PUBLIC WORKS INSPECTOR 48 HOURS IN ADVANCE OF <br />WORKCOMMENCING. <br />THIS IS A COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIAL <br />REV DESCRIPTION DATE <br />DESIGN: CITY RISE <br />DRAWN BY: <br />APPROVED: <br />APPROVED: <br />APPROVED: <br />IMPORTANT NOTICE <br />Section N 4216/4217 of the Government Code requires a <br />Dig Alert Identification Number to be issued before a <br />"Permit to Excavate" will be valid For your Dig Alert I.D. <br />CALL TOLL FREE <br />48 HOURS BEFORE YOU DIG <br />UNDERGROUND SERVICE ALERT <br />1-800-227-2600 <br />LEGEND, GENERAL NOTES <br />1549 N BROADWAY AVE, STOCKTON <br />JOB#: JB1587612 <br />CONSTRUCTION TYPE: OVERLASH <br />SYSTEM: SAN JOAQUIN COUNTY <br />NODE: ---- <br />SHEET: CD -0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.