Curb, Batter, and Edge o <br />sidewolh pavement <br />Street R/W I 3" AC <br />pavement <br />12- <br />Metal lid on - <br />- E P all meter boxes ' ' ''-s' <br />- - t - 4 ,l \ Cost iron lid (all locations <br />Christy C-20 I I //j .- <br />- <br />• lid, or equal ; i A ' .• I , % <br />Exist. Ground <br />I - 18 I , II ri</!! <r/ !r'i<!i<r rti' 1 c / '!! ' : Rattle -proof, machined <br />Bottom of Ditch Christy B12 box, i 4 1 .''I- `'' seating surface <br />(if any) or equal meter I 1 '•t' FOR ALL STREET Stone <br />box- Meter I ` --6'-- .:' O r < LOCATIONS — Plue Reflective Pavement Marker . _ 6" 14 1/4" 6" arracc ini <br />/ I ! R W _ <br />1 1 1 5/8 <br />2" asphalt concrete <br />AngPLAN VIEW /8 .. <br />Finished grade <br />le <br />Patterson <br />Stop <br />oh- Variable <br />Service Line <br />3/4" fvlin. Size / \r <br />\ frame I Concrete Thrust I r\ 9 , <br />ArchitectureVa1ve box and lid <br />refer to Standard Drowing Q Block _ <br />No.<v Break -off . 3 ✓ • y y ' /1\ Planning <br />1 Connection ; 1 ; join; I 1 N 8 :- r' <br />t\ Adaptor - 5/8" x 36" Rebar with 2" above ground Ilne `` `` FOR OFF JTRET Interior Architecture <br />` PLAN CHRISTY G-8- or e uol I <br /> <br />Corp 2 hose clamps 11' apart I <br />Stop - 4 <br />i _L.- / valve box L A I N <br />24" min conver below bottom ' ' :`'' ` /-Sdewaik Concrete base to be' <br />of ditch it an Water main i 2' x 4' concrete _ Mork "vJ at me local on 3U. j I Extensions around valve box. <br />Ser✓i<,e clamp (' y) -- ' _i_ -- One Market Plaza <br />_ Concrete base not <br />Double Stror ap) - e I anchor block — i \ i/?rr\ ,'. '. ,' \r_tg min necessary when Spear Street Tower <br />----- — -- — — --- --- --- -- -- _ _ax <br />valve box is ,orated Suite 400 <br />,/ , -Z` In bock of sidewolk. <br />Conc. thrust block -- -- 2- Threaded Cop San F ra n c i s c o <br />NOTES: I #5 rebcr top and bottom - - <br />- !j 1 Cost ran cop topped 2"-- ♦ i 2" Gale. iron Riser CA 94105, <br />• <br />1 Service line material shall be type k copper, polyethylene Conc. thrust <br />or polybutylene plastic. block \ti LDConcrete or PVC pipe <br />2. Plastic pipe up to 1 1/4" I.D. service shall be ultra high Flanged by ring-tite adaptor D cut to rt (to" ..d min 415 227-0100 <br />molecular weight (UHMW) Polyethiene as manufactured by (as required) <br />"Driscopipe" Orangeburg or approved equal with minimum r er 2" Galy iron 90 elbow <br />pressure rating of 160 psi. 6" flanged or .flanged by \ v T • ' <br /> % , •., - ' NOTES: <br />3. Plastic pipe for 2" I.D. service shall be PB 2110 ring-tite gate valve ;r 2" Bronze gate vnive <br />Polybutylene or approved equal with minimum pressure 2" threaded goiv <br /> with non -rising stern Architect,AlA <br />ratlnq of 160 psi. Tifcb No- 11 tee or equal iron nipple -24.. j <br />4. Corporation stop shall hove corporation cock threads. NOTES: max. length Vii`✓ sro l with 2" op or approved <br />5. Angle stop shall have swivel nut and lock wings. equal with 2" operating nut 1 Valve box and lid shall TT Christy No. G-5, <br />g P 1. Fire hydrants shall be placed with pumper outlet facing directly towards <br />12 Brooks No. I R T or 4 -TT, or equal. Tech. Checked Tech. — <br />6. Angle stop shall be vertically plumbed. the street. <br />h. <br />7. Size of service line shall be as required by the County. 2. All lids and grade rings shall have Coord. Arc <br />8. Mueller Icer service <br />nfittin s shall conform to ASTM 2. Fire hydrants shall be clean and free of concrete. NOTE: SECTION machined seating surfaces <br />g 3. Fire h drants to be American Darling model B 628, Lon Beach model 61'5, 3. Extensions shalt be as manufactured for the <br />designation D 2239. y g .. g For temporary blow -off use some concrete blocking but omit reinforcing bars valve box supplied or pipe of correct size can RUTHERFORD dC CHEKENE <br />9. Meter Scholl be Precision Meter Inc. model PPM 5/8"x3/4" James Jones J-4060, Dresser M & H style 929 reliant", Mueller Centurion <br />with attachment connector spuds or "Modern Centurion", or approved equal with (2)2 1/2" & (1)4" outlets. be used. <br />10. Lockable corporation cock will precede the meter and entire Dry barrel in the Stockton area: (2)2 1/2" & (1)4 1/2" wet barrel in other an Second St. Suite 800 N. <br />S <br />setup will be In the confines of the water box. areas as approved by the fire chief. San Francisco, CA 94107 <br />4. All hydrants shall be painted OSHA safety yellow or as approved by the <br />36 WATER METER 26 FIRE HYDRANT <br />. 1 6 2" BLOW OFF 6 VALVE BOX - Structural Engineer <br />GUTTMANN do MacRITCHIE <br />r <br />1 I 631 Howard Street, Suite 500 <br />T H R U S T B L 0 DETAILS <br />C 1 t E TA I L S Y ''I t~ 1" San Francisco, CA 94105 <br />1" 8 1/2 Mechanical Engineer <br />I 145° Max - _ -____ <br />THE ENGINEERING ENTERPRISE <br />m CONTINUOUS PLN VIEW 1305 Marina Village Parkway <br />m - m PIANO Alameda, CA 94501 <br />HINGE PEDESTAL, SEE <br />I - 12" — SPECIFICATIONS <br />r Gf9GrrEX wir>'v i6. / ..31 " irlR oX - S 6 . <br />"A" A' i ' 3/8" COPPER TUBE Electrical Engineer <br />A <br />-__ r.— — <br />Min. GOOSENECK, SAMPLING <br /> I <br />DOOR POINT <br /> _ _ KJELDSEN-SINNOCK c ASSOCIATES. INC. <br />BEND TEE OUTLET DEAD END TYPICAL SECTION r E 3/8" H.D. BRASS SHUT-OFF <br />1113 West Fremont Street <br />I <br />THRU VALVE (THREAD X THREAD) ' ' Stockton, CA 95203 <br />THRUST BLOCK `N <br /> I - - ------ - - -'► Civil Engineer <br />PADLOCKABLE DRAW I ATCH <br />( 1 _ <br />i. TTI <br />Approvals <br />( SPACE OF PRESSURE ' 1 ¢~ r✓rc rs srF. , r N <br />43" _ 1 <br />- <br />c yyr RECORDER I SE6 sc . r ,OrrvS>' <br /> i , nrHERS <br />i <br />• 3/8" H.D. BRASS SHUT-OFF I <br />VALVE (THREAD X THREAD) II <br />3/8"11 <br />1 <br />BRASS <br />PIPE <br />3/8" GATE VALVE - Q r- •JE I <br />IN WATER SERVICE <br />3/8" COUPLING BOX <br />NOTES: ,—. LL <br />6" CONCRETE PAD = r _ _ _ <br />Revisions <br />1. All thrust blocks shall be poured <br />against undisturbed soil an <br />be Class "B" Concrete. COPPER TUBE CONNECT TO MAIN WITH <br />d shall 3/8" TYPE K , <br />2. Thrust block dimensions ,were / Na ate <br />calculated l to allow a soil 3/4" CORP. STOP AND J <br />bearing value of 1,000 pounds 3/4' X 3/8" REDUCER <br />90% REVIEW 23 --MAR_ 9 <br />per square foot. <br />28 <br />WATER STUB FOR FUTURE 18 WATER SYSTEM SAMPLING STATION 8 IRRIGATION SYSTEM CONNECTION <br />38 THRUST BLOCK <br />SAN JOAQUIN <br />GENERAL HOSPITAL <br />REPLACEMENT PROJECT, <br />PHASE 1A <br />WATER <br />DETAILS <br />Scale: <br />Project No. Drawing No. <br />' 53000.09 <br />C 1.64 <br />Date <br />0 30 20 10 <br />4 <br />t <br />THRUST <br />BLOCK DIMENSIONS <br />FITTINGS <br />i "A" 1. <br />B„ 1 FITTINGS <br />I A <br />I B <br />6 LINE <br />10" LINE, y <br />22 1/2 <br />1'-6" <br />_ <br />1'-6" <br />3'-0" <br />_ <br />45 <br />2'-0" <br />2'-0" _ <br />4'_0 <br />3'-0" <br />-- 90 <br />3'-0" <br />2'-6" <br />5'-6• <br />4,-0" <br />- - TEE OUTLET <br />3'-C)" <br />2- a" _- <br />-- 4'-0" <br />— DEAD END <br />3,-0„ <br />2--0" <br />Tl 4'-0,. <br />4,-0" <br />8 LINE <br />12" UNE <br />22 1/2 <br />I_ 2'-0" 1 <br />_ <br />2'-0"--- <br />-0' <br />1 3•-0., <br />45 <br />3'-0„ <br />2-6- -- <br />4'-6' <br />4,-0.. <br />90 <br />4'-0" <br />3'-6" <br />8'-0" <br />4'-0" <br />TEE OUTLET <br />3'-6" <br />3'-0" <br />5'-6" <br />4'-0" <br />DEAD END <br />3'-6" <br />3'-0" 1 <br />5'-6" <br />I 4'-0" <br />( 1 _ <br />i. TTI <br />Approvals <br />( SPACE OF PRESSURE ' 1 ¢~ r✓rc rs srF. , r N <br />43" _ 1 <br />- <br />c yyr RECORDER I SE6 sc . r ,OrrvS>' <br /> i , nrHERS <br />i <br />• 3/8" H.D. BRASS SHUT-OFF I <br />VALVE (THREAD X THREAD) II <br />3/8"11 <br />1 <br />BRASS <br />PIPE <br />3/8" GATE VALVE - Q r- •JE I <br />IN WATER SERVICE <br />3/8" COUPLING BOX <br />NOTES: ,—. LL <br />6" CONCRETE PAD = r _ _ _ <br />Revisions <br />1. All thrust blocks shall be poured <br />against undisturbed soil an <br />be Class "B" Concrete. COPPER TUBE CONNECT TO MAIN WITH <br />d shall 3/8" TYPE K , <br />2. Thrust block dimensions ,were / Na ate <br />calculated l to allow a soil 3/4" CORP. STOP AND J <br />bearing value of 1,000 pounds 3/4' X 3/8" REDUCER <br />90% REVIEW 23 --MAR_ 9 <br />per square foot. <br />28 <br />WATER STUB FOR FUTURE 18 WATER SYSTEM SAMPLING STATION 8 IRRIGATION SYSTEM CONNECTION <br />38 THRUST BLOCK <br />SAN JOAQUIN <br />GENERAL HOSPITAL <br />REPLACEMENT PROJECT, <br />PHASE 1A <br />WATER <br />DETAILS <br />Scale: <br />Project No. Drawing No. <br />' 53000.09 <br />C 1.64 <br />Date <br />0 30 20 10 <br />4 <br />t <br />