Laserfiche WebLink
SECTION A -A SECTION B -B SECTION C -C <br />11 3/4" DIA. - <br />5/8" 1" 1" DIA. OPENING 3/4" DIA. OPENING 3/4"� 2 5/16" <br />3 5/8" FILLET I7DIA <br />1 1 1 /2" / 1 2 1 /4' <br />1 3 3/4" 3" FILLET 1/2 <br />II (TYP) \ I 1/4" <br />1/2„ <br />10 5/8 -F- 9 1 /4" DIA. -►-10 5/8" DIA. -�I I <br />7/16" 1/2" I I II 1/16" <br />10 7/8DIA. 9 1/2" DIA. 11 1/8" DIA. y <br />l► 1 1 5/8" DIA. -yll 1•-10 1 /4" DIA. Eii 1/2' DIA. i 9.1 <br />I I I II I I 2 <br />j---1 1 7/8" DIA. 1 { -10 1/2" DIA. yl 12 3/4" DIA. -,ul 1 1/4" <br />12 3/4" DIA. F 11 1/2" DIA. 14 1/4" DIA. 3/4" <br />VIII III I 1/8"-�� IIII' �I111 i I I III <br />1/8" J•,-11-15 1/ 4" DIA. - 1 1 1 /4.. <br />3/8" -�I -1 /8" 3/16" <br />- ` i <br />1/2" <br />A j� / \\\\ A B //j \\\ B C y �j�/ \\\\Ips C �_ 3/4,. <br />11 3/4" DIA. - <br />\\\ 3/8" 1/2" � 3/4„ <br />VARIES 1 1/2", <br />2" & 2 1/2" <br />-y <br />COVER "A" COVER "B" FRAME DETAIL FOR COVER "B" I 1/$.. _y 3/4" <br />(FOR UNPAVED AREAS) (FOR PAVED AREAS) (IN PAVED AREAS) 3/4" - - <br />5/16" 4-"-10 3/4" DIA. - <br />1 12 3/4" DIA. TYPICAL CENTER SECTION OF FRAME RISER <br />2" SPACE WITH [ 8 1/8" DIA 1 5/8" SPACE WITH (FOR PAVED AREAS) <br />1' RAISED LETTERING (TYP) ` 1 OR 3/4" RAISED LETTERING (TYP) AL' F <br />If _ \\ 1/4" <br />❑�� / 1/4"❑❑❑❑❑❑❑❑ (TYP) NOTES: <br />a❑❑❑❑ �a11 <br />(TYP) 0 0 0 0 0 0 0 ❑ 3/4„ 1. Frame, cover and casing extensions to be <br />❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ 1 3/4" SPACE WITH of good quality domestic cast iron, free <br />❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ 1 1/8" RAISED LETTERING L ❑ u WATER 0 ❑ (NP) from flaws and blow holes, and of <br />( 1 1111 <br />❑ ❑ ❑ ❑ ❑ ❑O❑ ❑ ❑ ❑ ❑ sufficient strength to resist breakage by <br />�.J street traffic. <br />2" SPACE WITH ❑❑ WATER ❑❑ o❑❑❑❑❑❑❑❑❑❑ <br />1 " RAISED LETTERING 7/8" (TYP) 2. Castings to be true, and if necessary to <br />❑ ❑ ❑ I 1 4" ❑ ❑ ❑ ❑ ❑ ❑ D 3 8" be trimmed on emery wheel to prevent <br />L ��1 / ❑ ❑ ❑ ❑ ❑ ❑ / rocking of cover in any position in the <br />❑ �/�� D(�' (TYP) 11 1/2" DIA. p� frame. <br />` RV 1 Ij V 1 1/4" 3. See latest revision of drawing CW -439 for <br />3/4" (TYP) valve cover, casing, and frame installation <br />7/8„ (TYP) (TYP) details. <br />8 1/4" DIA. <br />4. Cover "A" does not have a matching cost <br />TOP VIEW OF COVER "A" NOTE: TOP VIEW OF COVER "B" frame. <br />LETTERING AND DETAILS SHALL BE RAISED <br />1/8" ABOVE FACE OF COVER "A" AND "B". <br />CW VALVE COVER AND FRAME FABRICATION DETAILS <br />14R6 FOR PAVED AND UNPAVED AREAS <br />COVER "B" PER 2' MIN. OR <br />PER GOVERNING AGENCY'S <br />REQ. FRAME PER <br />MUELLER INSTA-TITE/ <br />LATEST REVISION I� <br />(2'-6" SQ. - KERN COUNTY) -'-jl <br />CAMBRIDGE <br />LATEST REVISION <br />APAC <br />OF DRAWING CW - 14 <br />(S MIN. - SAUNAS) <br />SPLICE. SEE x-45" <br />OF DRAWING CW -14 <br />FORD PACK JOINT <br />CONSTRUCT 2" MIN. A.C. IN <br />BRASS <br />FRAME PERFINISHED <br />GRADE <br />A <br />FLEXIBLE PAVEMENT AREAS <br />NOMINAL MAIN SIZE x 1" CC <br />DWG. CW -14 <br />S90 SERIES <br />TAPE -- <br />TRACER WIRE <br />d IF <br />SPLICE. SEE <br />-x--45'' <br />DWG. CW -850 <br />TYpE <br />. <br />STREET <br />NAPE <br />----- <br />----- <br />313 SERIES <br />VARIABLE <br />C <br />SECTION <br />NOMINAL MAIN SIZE <br />1" CC <br />BR 2B SERIES <br />202B SERIES <br />3825 SERIES <br />° <br />323 SERIES <br />----- <br />3' <br />3" MIN. <br />CORPORATION STOP (BALL) <br />1" CC x 1" MFG. <br />F/PE IPS <br />IN SALINAS ONLY - <br />----- <br />----- <br />° o°°�-gTHICKNESS <br />° ° oo <br />1" PE PLASTIC PIPE <br />1" PE PLASTIC <br />(8" MIN. FOR KERN COUNTY <br />PIPE IPS <br />INSTALL #4 AWG DIAGONALLY <br />2" FROM CASING & 3" ABOVE <br />F <br />- ---- <br />1" 90' ELBOW <br />- <br />1" MFG F/PE IPS <br />& SALINAS OR PER GOVERNING <br />THE BOTTOM QF P.C.C. <br />L66-44-NL <br />G <br />AGENCY'S REQUIREMENTS) <br />1" F/PE IPS x 1" <br />SEE P.C.C. COLLAR <br />BA63-444W-U-AWT-NL <br />746028-33 1" <br />210NL-PE4T4 <br />----- <br />CONSTRUCT CLASS "B" P.C.C. 12" <br />REINFORCEMENT DETAIL <br />CONSTRUCT SUB BASE TO <br />COLLAR. EXTEND COLLAR TO SALINAS <br />SUBGRADE OR EXTEND P.C.C. <br />FINISHED GRADE IN RIGID ONLY <br />FULL COMPACTION <br />(CONTRACTOR'S OPTION) <br />SPLA SLIP SLEEVE, <br />PAVEMENT AREAS <br />3/4" METER H -10879N A24 -NL 71OJ24 440NL-N4R2 ----- ----- <br />BASE ROCK VARIES TO EQUAL <br />" GALVAN <br />BY CWS COMPANY: 5/8" x 3/4" METER (USE FOR LOT SIZE < 10,000 SQ. FT.) LENGTH 7 1/2". <br />J <br />STREET SECTION <br />GIZEDD <br />T <br />VALVE CASING TO BE 12" I.D. <br />METER SPACER <br />DEVELOPER'S CONTRACTOR SHALL INSTALL SCH. 80 PVC NIPPLE IN PLACE OF METER: 1-1/4" DIAMETER, <br />SEE GALVANIZED <br />SLIP SLEEVE <br />#14 GA WELL CASING t3' LONG <br />METER COUPLING <br />DETAIL <br />SEE ALTERNATE INSTALLATION <br />STANDARD PAVED AREA INSTALLATION <br />N.T.S. <br />NOTE: <br />TO EXTEND AN EXISTING STANDARD PAVED INSTALLATION: <br />REMOVE FRAME, ADD STANDARD CAST FRAME RISER PER LATEST <br />REVISION OF DRAWING CW -14, OR TACK WELD ADDITIONAL STEEL <br />CASING AS REQUIRED, REPLACE FRAME. <br />FINISHED COVER "A" PER FRAME PER COVER "B" PER <br />I /- LATEST REVISION LATEST REVISION LATEST REVISION <br />1 OF DRAWING CW -14 OF DRAWING CW -14 I �OF DRAWING CW -14 <br />GRADE <br />VALVE CASING TO BE <br />12" I.D. #14 GA. WELL CASING <br />-A- <br />(t3 FT. LONG) <br />STANDARD INSTALLATION <br />(IN UNPAVED AREAS) <br />NOTE: <br />TO EXTEND AN EXISTING STANDARD UNPAVED INSTALLATION: <br />REMOVE COVER, TACK WELD ADDITIONAL STEEL CASING AS <br />REQUIRED, AND REPLACE COVER. <br />OF MAIN <br />EXISTING <br />FRAME <br />NOTES: <br />1. ALL PE PLASTIC PIPE REQUIRES TRACER WIRE TAPED TO PE PIPE AND <br />EXTENDED INTO METER BOX PER LATEST REVISION OF DWG. CW -850 AND AS <br />SPECIFIED IN CWS CO. MATERIAL SPECIFICATIONS DWG. CW -832. <br />2. SADDLES ARE REQUIRED ON ALL PVC C-900, AC, STEEL, OR WROUGHT IRON <br />PIPE. <br />3. INSERT STIFFNERS SHALL BE USED ON ALL PE PIPE WITH COMPRESSION <br />CONNECTIONS. <br />4. WHEN USING MUELLER INSTA-TITE, BEVEL THE PE PIPE WITH MUELLER'S <br />BEVELING TOOL PER MANUFACTURER'S SPECIFICATIONS. <br />5. RESPONSIBILITY FOR SERVICE MAINTENANCE BY CWS CO. ENDS AT <br />DOWNSTREAM METER COUPLING (OR LEFT TO DISTRICT'S DISCRETION). <br />6. ALL PIPE FITTINGS IN CONTACT WITH WATER SHALL BE LEAD FREE (< 0.25% <br />LEAD) AND COMPLIANT TO NSF-61/SECTION 8. <br />OPTIONS: THESE OPTIONS MAY BE REQUIRED BY CWS CO <br />1. EXTEND CUSTOMER'S PIPING ±12" BEYOND METER BOX WITH TWO 12" <br />NIPPLES & TWO 90' ELLS, BRASS (OR GALVANIZED IF PREFERRED BY CWS). SEE <br />NOTE 5. <br />2. INSTALL BALL VALVE DOWNSTREAM FROM METER WHEN CUSTOMER'S PIPING IS <br />UPHILL FROM METER OR CUSTOMER'S VALVE IS A GREAT DISTANCE FROM METER. <br />3. INSTALL 1 " COPPER TUBING, TYPE K SOFT, INSTEAD OF PE WHEN CWS <br />REPRESENTATIVE DETERMINES THAT CONDITIONS ARE UNFAVORABLE TO PE. <br />�D <br />45' SIDE TAPPED <br />A (PVC C-900 PIPE) <br />B (STEEL, DUCTILE, CAST OR <br />WROUGHT IRON PIPE) <br />C (AC PIPE) <br />HYDRANT OUTLETS SHALL FACE STREET <br />AT 45' ANGLES (UNLESS DIRECTED OTHERWISE <br />BY C.W.S. CO. OR FIRE PROTECTION AGENCY) -� <br />VALVE CASING AND COVER EXTENSION, <br />EXISTING ASS'Y PER LATEST REVISION OF FINISHED SEE NOTE #3 <br />COVER REVISED DRAWING CW -14 AND CW -439 GRADE <br />FINISHED <br />rll=ll <br />GRADE 6" GATE VALVE, PO WITH ll= <br />RESTRAINED PO GASKETS ll <br />EXISTING REVISED 6" DUCTILE IRON PIPE <br />FINISHED STREET ELL OR TEE, PO WITH t3 <br />GRADE SECTION ONE RESTRAINED 6" RESTRAINED <br />PO GASKET MJ ADAPTER <br />CONCRETE THRUST <br />BLOCK POURED AGAINST 1 a ' <br />UNDISTURBED GROUND ` <br />PER LATEST REVISION :-1 <br />IMPORTANT a=l - <br />PLACE (4) GALVANIZED SELF -TAPPING OF DRAWING CW -435 X11 -u- i; <br />SCREWS INSIDE CASING TO SECURE NTE: IN STOCKTON, INSTALLATION BEYOND Z6" DUCTILE IRON, PO -r <br />SLIP SLEEVE TO PVC PIPE. TEE SHALL BE PER THE AGENCY'S REQUIREMENTS (RESTRAIN ALL PO JOINTS) <br />(C.W.S. CO. DOES NOT OWN FIRE HYDRANT) <br />EXISTING <br />12' PVC _y <br />PIPE <br />BRICK, TYPICAL - <br />EXISTING PAVED AREA PVC CASING <br />AND SLIP SLEEVE EXTENSION <br />N.T.S. <br />Y4" MIN. <br />ELONGATED <br />SEDGE CA' <br />VALVE CASING TO BE <br />L� -J- 12" SDR 35 (PS,6) PVC 1Y2" MIN. <br />(t3 FT. LONG) OVERLAP I <br />ALTERNATE INSTALLATION - - - - <br />(IN PAVED AREAS) �) <br />NOTE: \ <br />TO EXTEND PVC CASING IN PAVED AREA: -- <br />SEE EXISTING PAVED AREA PVC CASING <br />AND SLIP SLEEVE EXTENSION DETAIL. TOP VIEW SIDE VIEW P.C.C. COLLAR <br />40" ±Y8" FOR 12" CAN �-� REINFORCEMENT <br />VALVE (SALINAS ONLY) <br />FULL COMPACTION lll 11 CASING N.T.S. <br />AROUND VALVE llll <br />BRICK I <br />BONNET REQUIRED lll Tiff ---(SEE TOP VIEW) <br />LEVEL TWO BRICKS = = 20 GAGE GALVANIZED STEEL <br />TO PROVIDE END 12 tYg' (MIN. 1Y2 OZ. per SQ. FT. ZINC COATING) <br />1 -_ -1Tt L1 f-1Tf-`Ii <br />BEARING FOR-In-uT1-II-III- ITI=ITI=nl-ITI= <br />VALVE CASING I <br />1--+y2" MIN. OVERLAP <br />VALVE CASING FOOTING <br />TOP VIEW <br />N.T.S. <br />VALVE CASING FOOTING <br />SIDE VIEW <br />N.T.S. <br />GALVANIZED SLIP SLEEVE <br />N.T.S. <br />CW VALVE CASING, COVER, AND FRAME <br />439R6 INSTALLATION DETAILS <br />AWG <br />WIRE <br />TIES <br />STANDARD <br />INSTALLATION <br />N.T.S. <br />6" GATE VALVE, PO x FLG <br />WITH RESTRAINED PO GASKET <br />FLANGE-TYTE GASKET OR <br />AMERICAN TORUSEAL <br />FLANGE GASKET <br />(SEE NOTE #7) <br />ELL OR TEE -i <br />PART <br />PART NAME <br />PART SIZE <br />MUELLER INSTA-TITE/ <br />FORD ULTRA-TITE/ <br />A.Y. McDONALD <br />CAMBRIDGE <br />SMITH-BLAIR <br />APAC <br />/ <br />F <br />SPLICE. SEE x-45" <br />MUELLER PACK -JOINT <br />FORD PACK JOINT <br />- PE PIPE COULD BE <br />BRASS <br />BENT, IF A 2' RADIUS <br />A <br />30" MIN. <br />NOMINAL MAIN SIZE x 1" CC <br />TRACER WIRE <br />S90 SERIES <br />TAPE -- <br />TRACER WIRE <br />d IF <br />SPLICE. SEE <br />-x--45'' <br />DWG. CW -850 <br />TYpE <br />. <br />(TYP.) <br />NAPE <br />�D <br />45' SIDE TAPPED <br />A (PVC C-900 PIPE) <br />B (STEEL, DUCTILE, CAST OR <br />WROUGHT IRON PIPE) <br />C (AC PIPE) <br />HYDRANT OUTLETS SHALL FACE STREET <br />AT 45' ANGLES (UNLESS DIRECTED OTHERWISE <br />BY C.W.S. CO. OR FIRE PROTECTION AGENCY) -� <br />VALVE CASING AND COVER EXTENSION, <br />EXISTING ASS'Y PER LATEST REVISION OF FINISHED SEE NOTE #3 <br />COVER REVISED DRAWING CW -14 AND CW -439 GRADE <br />FINISHED <br />rll=ll <br />GRADE 6" GATE VALVE, PO WITH ll= <br />RESTRAINED PO GASKETS ll <br />EXISTING REVISED 6" DUCTILE IRON PIPE <br />FINISHED STREET ELL OR TEE, PO WITH t3 <br />GRADE SECTION ONE RESTRAINED 6" RESTRAINED <br />PO GASKET MJ ADAPTER <br />CONCRETE THRUST <br />BLOCK POURED AGAINST 1 a ' <br />UNDISTURBED GROUND ` <br />PER LATEST REVISION :-1 <br />IMPORTANT a=l - <br />PLACE (4) GALVANIZED SELF -TAPPING OF DRAWING CW -435 X11 -u- i; <br />SCREWS INSIDE CASING TO SECURE NTE: IN STOCKTON, INSTALLATION BEYOND Z6" DUCTILE IRON, PO -r <br />SLIP SLEEVE TO PVC PIPE. TEE SHALL BE PER THE AGENCY'S REQUIREMENTS (RESTRAIN ALL PO JOINTS) <br />(C.W.S. CO. DOES NOT OWN FIRE HYDRANT) <br />EXISTING <br />12' PVC _y <br />PIPE <br />BRICK, TYPICAL - <br />EXISTING PAVED AREA PVC CASING <br />AND SLIP SLEEVE EXTENSION <br />N.T.S. <br />Y4" MIN. <br />ELONGATED <br />SEDGE CA' <br />VALVE CASING TO BE <br />L� -J- 12" SDR 35 (PS,6) PVC 1Y2" MIN. <br />(t3 FT. LONG) OVERLAP I <br />ALTERNATE INSTALLATION - - - - <br />(IN PAVED AREAS) �) <br />NOTE: \ <br />TO EXTEND PVC CASING IN PAVED AREA: -- <br />SEE EXISTING PAVED AREA PVC CASING <br />AND SLIP SLEEVE EXTENSION DETAIL. TOP VIEW SIDE VIEW P.C.C. COLLAR <br />40" ±Y8" FOR 12" CAN �-� REINFORCEMENT <br />VALVE (SALINAS ONLY) <br />FULL COMPACTION lll 11 CASING N.T.S. <br />AROUND VALVE llll <br />BRICK I <br />BONNET REQUIRED lll Tiff ---(SEE TOP VIEW) <br />LEVEL TWO BRICKS = = 20 GAGE GALVANIZED STEEL <br />TO PROVIDE END 12 tYg' (MIN. 1Y2 OZ. per SQ. FT. ZINC COATING) <br />1 -_ -1Tt L1 f-1Tf-`Ii <br />BEARING FOR-In-uT1-II-III- ITI=ITI=nl-ITI= <br />VALVE CASING I <br />1--+y2" MIN. OVERLAP <br />VALVE CASING FOOTING <br />TOP VIEW <br />N.T.S. <br />VALVE CASING FOOTING <br />SIDE VIEW <br />N.T.S. <br />GALVANIZED SLIP SLEEVE <br />N.T.S. <br />CW VALVE CASING, COVER, AND FRAME <br />439R6 INSTALLATION DETAILS <br />AWG <br />WIRE <br />TIES <br />STANDARD <br />INSTALLATION <br />N.T.S. <br />6" GATE VALVE, PO x FLG <br />WITH RESTRAINED PO GASKET <br />FLANGE-TYTE GASKET OR <br />AMERICAN TORUSEAL <br />FLANGE GASKET <br />(SEE NOTE #7) <br />ELL OR TEE -i <br />PART <br />PART NAME <br />PART SIZE <br />MUELLER INSTA-TITE/ <br />FORD ULTRA-TITE/ <br />A.Y. McDONALD <br />CAMBRIDGE <br />SMITH-BLAIR <br />APAC <br />LETTER <br />F <br />SPLICE. SEE x-45" <br />MUELLER PACK -JOINT <br />FORD PACK JOINT <br />- PE PIPE COULD BE <br />BRASS <br />BENT, IF A 2' RADIUS <br />A <br />SERVICE SADDLE ALL BRONZE <br />NOMINAL MAIN SIZE x 1" CC <br />H-13400 SERIES <br />S90 SERIES <br />3805 SERIES <br />800 SERIES <br />393 SERIES <br />----- <br />B <br />SERVICE SADDLE DUCTILE IRON <br />NOMINAL MAIN SIZE <br />x 1" CC <br />DR 2A SERIES <br />F202 SERIES <br />----- <br />----- <br />313 SERIES <br />102 SERIES <br />C <br />SERVICE SADDLE ALL BRONZEx <br />NOMINAL MAIN SIZE <br />1" CC <br />BR 2B SERIES <br />202B SERIES <br />3825 SERIES <br />810 SERIES <br />323 SERIES <br />----- <br />D <br />CORPORATION STOP (BALL) <br />1" CC x 1" MFG. <br />F/PE IPS <br />FB1001-4-U-ANWT-NL <br />B -2996N + H15456N /FB1001-4-NL 747018-33 1" 301NL-A4PE4 ----- <br />HIGH DENSITY POLYETHYLENE PIPE, IRON PIPE SIZE, AWWA STANDARD C901, PE 4710, PC 200, SIDR7 <br />----- <br />----- <br />E <br />1" PE PLASTIC PIPE <br />1" PE PLASTIC <br />PIPE IPS <br />- ----- - - ---- <br />H -15464N L66 -44 -U -NL/ 74761-3Q 1" 105NL-PE4PE4 ----- <br />F <br />- ---- <br />1" 90' ELBOW <br />- <br />1" MFG F/PE IPS <br />----- <br />L66-44-NL <br />G <br />ANGLE METER STOP (BALL) <br />1" F/PE IPS x 1" <br />B-24266N/E-24259N <br />BA63-444W-U-AWT-NL <br />746028-33 1" <br />210NL-PE4T4 <br />----- <br />----- <br />METER SWIVEL NUT <br />/BA63-444W-NL <br />1" METER TO 5/8- <br />H <br />METER ADAPTERx <br />3/4" METER H -10879N A24 -NL 71OJ24 440NL-N4R2 ----- ----- <br />BY CWS COMPANY: 5/8" x 3/4" METER (USE FOR LOT SIZE < 10,000 SQ. FT.) LENGTH 7 1/2". <br />J <br />METER <br />1" METER (USE FOR LOT SIZE 10,000 SQ. FT. OR LARGER OF IF REWD TO MEET CITY'S FIRE SPRINKLER ORDINANCE) LENGTH 10" <br />K <br />METER SPACER <br />DEVELOPER'S CONTRACTOR SHALL INSTALL SCH. 80 PVC NIPPLE IN PLACE OF METER: 1-1/4" DIAMETER, <br />---- <br />----- <br />METER COUPLING <br />11" LONG WITH PIT <br />L <br />1" METER SWIVEL <br />NUT x M.I.P. <br />H -10890N <br />C38 -44 -2 -625 -NL <br />74624 <br />417NL-T4M4 <br />_____ <br />_____ <br />METER BOX - BROOKS #37 BOX W/ CAST IRON COVER OR <br />CHRISTY #B12 BOX W/ CAST IRON COVER. <br />M <br />IF OUTSIDE FULL TRAFFIC AREAS, USE CHRISTY FL12 BOX W/ <br />12" x 20" x 12" <br />----- <br />----- <br />----- <br />----- <br />----- <br />----- <br />SYN12S LID. CWS OPTION: 1 -PIECE COVER FL12D OR <br />ARMORCAST P6000485-ROMCAST BOX W/ A6000484DQ COVER & <br />DROP-IN LID A6000487. CWS OPTION: 1 -PIECE COVER A6000484 <br />1" PEP x 1" <br />N <br />ANGLE BALL VALVE <br />H-15426N+B-24378N/ <br />BA96-444W-U-AWT-NL <br />LOCKNUT <br />E-15429N+B-24278N <br />/BA96-444W-NL <br />P <br />IRON YOKE PIECE <br />----- <br />H-5040 <br />Y504P <br />----- <br />----- <br />----- <br />----- <br />Q <br />EXPANSION CONNECTION <br />----- <br />H -14234N <br />EC -4 -NL <br />----- <br />----- <br />----- <br />----- <br />R <br />YOKE COUPLING <br />LOCKNUT x FIP <br />H -14219N <br />C91 -44 -NL <br />----- <br />----- <br />----- <br />----- <br />lil <br />'IH L CUSTOMER'S <br />1i PIPE. SEE <br />OPTIONS 1 & 2 <br />STANDARD INSTALLATION <br />K -NIPPLE <br />DATE: INIT. <br />E <br />All. <br />MAP <br />NOT USE PART <br />PLAT <br />sessr <br />H" IF 1" METER <br />SYSTEM <br />IS USED. <br />TRACER WIRE <br />F <br />SPLICE. SEE x-45" <br />IN LIEU OF PART "F", <br />DWG. CW -850 Typ; <br />- PE PIPE COULD BE <br />(TYP.) <br />BENT, IF A 2' RADIUS <br />CAN BE ACHIEVED <br />SIDE VIEW FRONT VIEW <br />METER BOX METER BOX <br />WHEN REQUIRED BY CWS COMPANY, PLACE BRICKS ON TWO SIDES OF <br />METER BOX FOR SUPPORT (OR 2" x 4" PRESSURE TREATED LUMBER) <br />FIRE HYDRANT, SEE NOTE #1 <br />2"t SEE NOTE #4 <br />HYDRANT BURY <br />MECHANICAL JOINT x FLG <br />18" MIN. <br />CONCRETE THRUST BLOCK <br />POURED AGAINST UNDISTURBED <br />GROUND. (8 SQ. FT. MINIMUM <br />BEARING AREA) <br />PO x FLG <br />ALTERNATE <br />INSTALLATION <br />N.T.S. <br />NOTES: <br />1. For district specific fire hydrant models and requirements, see District fire <br />hydrant form, note 18 on main extension drawing, or verify with C.W.S. <br />Co. representative. <br />2. All fire hydrant materials shall comply with latest C.W.S. Co. material <br />specifications. <br />3. A hydrant extension may be required to adjust for finished grade. <br />4. For wet barrel hydrants this dimension is from finished grade to bury's <br />flange or extension's flange when an extension is required. <br />5. Push -on, flanged fitting joints, and/or threaded -flanged risers may be <br />required in certain fire protection districts. Verify with C.W.S. Co. <br />representative all fire hydrant material prior to the installation. (In <br />Stockton verify with the fire protection agency that has jurisdiction.) <br />6. Fire hydrant barricades shall be required when a vertical or rolled curb <br />does not exist, or when the fire hydrant needs to be protected from <br />moving vehicles, per latest revision of drawing CW -822. <br />7. All machine bolts and nuts shall be 304 stainless steel, except for <br />break -off bolts. <br />8. A 90' elbow with restrained push on joints may be required for the fire <br />hydrant installation when space is limited and the hydrant lead must run <br />parallel to the main or the location of the fire hydrant requires the bend. <br />9. Protect all underground bolts and nuts per C.W.S. Co. standard coating <br />specification. <br />10. A break -off check valve may be required in sloped terrain as specified by <br />district personnel. Use Clow Model LB400 or approved equal. <br />('CW TYPICAL FIRE HYDRANT <br />380R16 INSTALLATION <br />IMPORT BACKFILL REQUIRED <br />WHEN GOVERNING AGENCY'S <br />COMPACTION REQUIREMENTS <br />CANNOT BE MET WITH NATIVE <br />BACKFILL <br />FINISHED GRADE <br />30 IN. \ <br />TRACER WIRE <br />TAPE <br />D <br />�- <br />45' SIDE TAPPED <br />A (PVC C-900 PIPE) <br />B (STEEL, DUCTILE, CAST OR <br />WROUGHT IRON PIPE) <br />C (AC PIPE) <br />E <br />M <br />VA�/VA N <br />H HQ R <br />PIPE CUSTOMER'S <br />K NIPPLE <br />TAPE �E P <br />DO NOT USE PART <br />�F "H" IF 1" METER <br />IS USED. <br />ALTERNATE INSTALLATION <br />CW STANDARD I SERVICE CONNECTION FOR <br />555R15 5/8" X 3/4" METER AND 1" METER <br />-E <br />O D <br />TAPPED AT TOP OF MAIN <br />USE THIS INSTALLATION ONLY WHEN <br />METER BOX IS LOCATED DIRECTLY <br />ABOVE THE MAIN <br />WIDTH VARIES <br />AC OVERLAY <br />1Y2" THICK (MIN.) <br />CLASS II AB <br />950 COMPACTION <br />(SEE NOTE 6) <br />6" MIN. AC MIN. <br />GRIND _ INITIAL LIFT <br />EXISTING AC PAVEMENT (TYP) (SEE NOTE 6) <br />(THICKNESS VARIES) 2Y2 <br />FINISHED Y2" <br />GRADE 1 <br />PLACE LINE GUARD TAPE \\\ °On° °�o °n \ 6" MIN. <br />MARKED "WATER" <br />PAVEMENT & BASEROCK °° 22 ° \ (SEE NOTE 6 ) <br />/ ° ° ° ° ° `� // <br />(WHERE REQUIRED) (FOR ALL PIPE) j v ° 4' MIN. <br />\� <br />OTHERWISE <br />NATIVE FILL © 95% COMPACTION ° NOTED <br />(SEE NOTE 6) \/ <br />SAND ENVELOPE / <br />/ \ 14 <br />TRACER WIRE / 12" <br />(FOR ALL PIPE) / <br />4 MIN <br />UNLESS POLYETHYLENE ENCASEMENT, 8MIL / \ <br />OTHERWISE (FOR DUCTILE IRON PIPE) 6„ <br />NOTED <br />PVC C-900 PIPE OR 6" BOTH _ <br />DUCTILE IRON PIPE SIDES <br />NOTE: <br />1. ALL EXCESS SPOIL IN TRACT IS TO REMAIN TRENCHSIDE AND ALL <br />EXCESS SPOIL OFF TRACT IS TO BE REMOVED. <br />2. ALL VALVE CASINGS AND COVERS SHALL BE RAISED TO FINISHED <br />GRADE AFTER PERMANENT PAVEMENT HAS BEEN PLACED. <br />3. SAW CUT TRENCH SECTION, FILL AND PLACE 2Y2" AC LIFT (MINIMUM). <br />NOTE: 4. GRIND EXISTING AC 6" BEYOND SAW CUT, 1Y2" THICK. <br />1. ALL EXCESS SPOIL IN TRACT IS TO REMAIN TRENCHSIDE <br />AND ALL EXCESS SPOIL OFF TRACT IS TO BE REMOVED. 5. PLACE FINAL AC OVERLAY OF %" THICK OVER ENTIRE 4' WIDE WIDTH. <br />2. ALL VALVE CASINGS AND COVERS SHALL BE RAISED TO FINISHED 6. LOCAL AGENCY STANDARDS SHALL APPLY FOR ALL PAVEMENT REPAIRS. <br />GRADE AFTER PERMANENT PAVEMENT HAS BEEN PLACED. <br />PAVEMENT TRENCH CROSS SECTION <br />N.T.S. <br />ENGINEERING <br />DEPARTMENT <br />REVISIONS: <br />DATE: INIT. <br />DLSTRIBUTION ❑ <br />MAP <br />"WATER" LINEGUARD TAPE <br />PLAT <br />sessr <br />❑ <br />SYSTEM <br />FOR ALL PIPE) <br />2' MAX <br />STATION <br />, <br />SCHEMATIC <br />TF, <br />SAND ENVELOPE <br />• <br />TRACER WIRE <br />(FOR ALL PIPE) <br />TM 12" <br />POLYETHYLENE <br />ENCASEMENT, 8MIL <br />(FOR DUCTILE IRON PIPE) <br />_ <br />PVC C-900 PIPE <br />OR DUCTILE IRON PIPE <br />\� <br />OTHERWISE <br />NATIVE FILL © 95% COMPACTION ° NOTED <br />(SEE NOTE 6) \/ <br />SAND ENVELOPE / <br />/ \ 14 <br />TRACER WIRE / 12" <br />(FOR ALL PIPE) / <br />4 MIN <br />UNLESS POLYETHYLENE ENCASEMENT, 8MIL / \ <br />OTHERWISE (FOR DUCTILE IRON PIPE) 6„ <br />NOTED <br />PVC C-900 PIPE OR 6" BOTH _ <br />DUCTILE IRON PIPE SIDES <br />NOTE: <br />1. ALL EXCESS SPOIL IN TRACT IS TO REMAIN TRENCHSIDE AND ALL <br />EXCESS SPOIL OFF TRACT IS TO BE REMOVED. <br />2. ALL VALVE CASINGS AND COVERS SHALL BE RAISED TO FINISHED <br />GRADE AFTER PERMANENT PAVEMENT HAS BEEN PLACED. <br />3. SAW CUT TRENCH SECTION, FILL AND PLACE 2Y2" AC LIFT (MINIMUM). <br />NOTE: 4. GRIND EXISTING AC 6" BEYOND SAW CUT, 1Y2" THICK. <br />1. ALL EXCESS SPOIL IN TRACT IS TO REMAIN TRENCHSIDE <br />AND ALL EXCESS SPOIL OFF TRACT IS TO BE REMOVED. 5. PLACE FINAL AC OVERLAY OF %" THICK OVER ENTIRE 4' WIDE WIDTH. <br />2. ALL VALVE CASINGS AND COVERS SHALL BE RAISED TO FINISHED 6. LOCAL AGENCY STANDARDS SHALL APPLY FOR ALL PAVEMENT REPAIRS. <br />GRADE AFTER PERMANENT PAVEMENT HAS BEEN PLACED. <br />PAVEMENT TRENCH CROSS SECTION <br />N.T.S. <br />ENGINEERING <br />DEPARTMENT <br />REVISIONS: <br />PLAT SHEET NO.: <br />SCALE: <br />N.T.S. <br />DRAWN BY: <br />DESIGNED BY: <br />CHECKED BY: DATE: <br />APPROVED BY: DATE: <br />DISTRICT: <br />STOCKTON <br />DATE: <br />5/18/2018 <br />PROJECT ID.: <br />00117472 <br />DRAWING NO.: <br />y <br />J <br />r <br />571 <br />DATE: INIT. <br />DLSTRIBUTION ❑ <br />MAP <br />PLAT <br />sessr <br />❑ <br />SYSTEM <br />❑ <br />SCHEMATIC <br />STATION <br />SCHEMATIC <br />PLAT SHEET NO.: <br />SCALE: <br />N.T.S. <br />DRAWN BY: <br />DESIGNED BY: <br />CHECKED BY: DATE: <br />APPROVED BY: DATE: <br />DISTRICT: <br />STOCKTON <br />DATE: <br />5/18/2018 <br />PROJECT ID.: <br />00117472 <br />DRAWING NO.: <br />y <br />J <br />r <br />571 <br />