Laserfiche WebLink
SAVE THESE INSTRUCTIONS <br />SLIM I I tR MOUNTING (see Fig. 1) <br />1. Luminaire is intended to be mounted to a 2 318" od (2"pipe size) x min. 5" <br />long tenon. <br />2.Open or remove door (wiring instructions step #2). <br />3. With power disconnected, slip luminaire over tenon, passing field supply wires <br />through into luminaire. Adjust the (6) set screws to level luminaire, then tighten <br />all (6) set screws to 150 in -Ib in an alternating fashion. Recheck torque on all <br />set screws. <br />4. Proceed to the wiring instructions section below. <br />ARM MOUNTING (see Fig° 2> <br />1. Ensure that the power is disconnected. <br />2. Ensure that pole is drilled per the pattern at right, remove any burrs or sharp <br />edges from the center wire way hole. <br />3. Insert the field supply wires through the wire way of backplate (item 2), and <br />through the pole wire way hole, insert backplate through the top of the pole, <br />oriented as shown, and align holes in backplate with holes in pole. <br />4. Insert (2) rods (items 5) through the pole holes and thread into backplate <br />(item 2), until flush with inward -facing surface of backplate. <br />5. Slip adapter plate (item 3, round poles only, curved side facing pole) and <br />rectangular arm (item 4) over the (2) rods (items 5) making sure the rods run <br />through the extruded grooves. pass field supply wires through the arm. <br />6. Open or remove luminaire door (wiring instructions step #2). <br />7, Insert the field supply wires through the wire way hole in the luminaire <br />housing, and the (2) rods (items 5) through the corresponding mounting holes. <br />8. Secure the housing to the end of the arm using (2) each flat washer, lock <br />washer, and nut (items 6, 7 and 8), if necessary, adjust rods (item 5) so that <br />the threads completely penetrate backplate and nuts, torque nuts to 150 in -Ib. <br />9. Proceed to the wiring instructions section below. <br />Maintenance Notes <br />FIGURE 1 <br />• <br />'Fr SET SCREWS <br />was --b <br />FIGURE 2 <br />A <br />2 1l2" 0 3/8" <br />0 5/8" <br />03/8" <br />VIEW A <br />Bacl<plate must be <br />shown as oriented <br />1. Disconnect power before servicing. note especially that drivers must be powered down at least one minute <br />before plugging or unplugging any connectors on the output side, or led damage may result. <br />2. The door contains the drivers) and transformer, if applicable, and can be removed by referring to wiring <br />instructions step #2. <br />Warning: see note 1. <br />3. The photocell receptacle, if so equipped, may be rotated by loosening the two screws on top, turning to desired <br />position, and securely re -tightening screws. <br />93058569 Rev A <br />2041 SBIh Ave Clr E, eratlenton, FL 34203 800 345-4928 ON• <br />l ) www.beaconproducis.com ' <br />SAVE THESE INSTRUCTIONS <br />PK2 MOUNTING (see Fig. 3 and Fig. 4) <br />1. Luminaire Is intended to be mounted to a 2 3/8" OD (2"pipe size) x min. 5" long tenon. <br />2, Open or remove door (wiring instructions step #2). <br />3. With power disconnected, slip luminalre over tenon, passing field supply wires through Into luminaire. Remove knuckle cover to weave wiring <br />through the swivel area. Adjust the (4) set screws snug tight, then torque all (4) set screws to 150 in -Ib In an alternating fashion. Recheck torque on <br />all set screws. <br />4. With cover removed, loosen adjustment screw to change positioning angle, tighten screw securely and replace cover with all gaskets/seals in <br />original position to maintain weather tightness, do not adjust over 30 degrees above horizontal. <br />Fixtures with sensors should be mounted parallel with ground (horizontal) in order to not diminish range and accuracy of sensors. <br />5. Proceed to the wiring instructions section below. <br />FIGURE 3 <br />Vertical PK2 Mounting ' <br />NOTE DO NOT EXCcrD <br />300 UPWARD ANGLE. <br />Note that in vertical orientation that 600 0 <br />shouId line up with indicator line. 11 <br />FIGURE 4 <br />K2 Mounting <br />Horizontal P <br />NOTE: DO NOT EXCEED <br />300 UPWARD ANGLE. <br />ADJUSTMENT SCRE1 <br />COVER WITf <br />DEGREE TICK MARK <br />ng Instructions (all mounting types) <br />1. These instructions presume that the luminaire has already been mounted (as per above) with field supply wiring (from pole) extended into <br />driver/wiring compartment. Disconnect power before perf <br />orming these steps. <br />2, Open door by loosening two key -slotted screws, pushing door forward, and swinging down. If desired, door may then be removed by unplugging two <br />connectors and lifting door out. <br />3. Check supply voltage <br />against luminaire rating label. Supply Wring must be 12-18 gauge for use with terminal block. Strip supply wire ends 3/8"- <br />7/16", pass through supplied open cable tie and hook up to terminal block. Refer to the factory wiring installed at the opposite side of the terminal <br />block, matching the hot wire to factory black wire, neutral (or opposite phase) to factory white wire, and ground to factory green wire. Connection is <br />made by pressing each terminal block tab with screwdriver or finger, inserting wire, and releasing tab, note: although there are extra spaces on the <br />terminal block, the luminaire is not intended or rated for pass-through wiring connections. <br />4. Pull cable tie closed to secure wiring. Work out any slack in wiring between cable tie and pole/mounting surface, <br />5. If Sheet <br />door was removed, reconnect connectors if unplugged and orient door back In housing's door track so that wiring will be Inside housing when <br />closed (see Fig. 5). Swing door to be horizontally flush with housing, sliding door backward so that screws are within slot portion of key -slot. Ensure <br />wiring Is not pinched. Tighten two key -slotted screws to 30 in -lbs each (see Fig. 6). <br />s. Turn on power and test luminalre. <br />FIGURE 5 FIGURE 6 <br />/ � KEY -SLOT <br />*I <br />m <br />VIEW B <br />93056569 Rev A t4 <br />2041 551h Ave CIr E, Bradanlon, FL 34203 (B00) 345-4928 www.beamnproducls.wm ®" "�" '�"O <br />Contractor: <br />LENZ1 50LAR <br />LENZI INCORPORATED <br />51-15#1007527 <br />g47 N. CLUFF AVE, SUITE B I <br />LODI, CA 95240 <br />(209) 224-5950 <br />www.lenzlcon5tructlonand5obr,com <br />Project: <br />SOLAR LIGHT POLE <br />3222 COLLIER RD, EAST <br />ACAMPO CA 95220 <br />Project Details: <br />PV ARRAY: 550 W <br />BATTERY BANK: 224 Ah, 5.4 kW <br />REVISIONS <br />DESCRIPTION <br />DATE <br />REV <br />PERMIT SET <br />12/31/2019 <br />A <br />T1tle: <br />VIPER INSTALL <br />INSTRUCTIONS <br />Sheet Number: <br />D2, <br />Sheet Slze: <br />ANSI B- 17 11 X I I" <br />DESIGN DRAFTING BY: <br />AARON CARDWELL <br />SepiSOlar <br />POWER BY DESIGN <br />Reviewed Approved by: <br />CM <br />