My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permits & Development - Encroachment(EP)/Driveway(DW) Permits -2019_Driveway Permits_PS-1903501 thru PS-1904000_ - PS-1903746
PublicWorks
>
- PUBLIC SERVICES
>
PERMITS & DEVELOPMENT
>
Encroachment(EP)/Driveway(DW) Permits
>
2019
>
DRIVEWAY PERMITS
>
PS-1903501 thru PS-1904000
>
Permits & Development - Encroachment(EP)/Driveway(DW) Permits -2019_Driveway Permits_PS-1903501 thru PS-1904000_ - PS-1903746
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/26/2024 3:54:20 PM
Creation date
6/26/2024 3:54:05 PM
Metadata
Fields
Template:
Permits_Development
DocName
PS-1903746
Category07
Encroachment(EP)/Driveway(DW) Permits
Year2
2019
Notes2
14602 N. Alpine Rd., Lodi
Address
8650 Wastewell Way, Tracy,CA 95304
Application
Sierra Construction
Type
Driveway Encroachment
Supplemental fields
APN
06307020
Cross Ref
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
R/W <br />Alternate edge <br />Set pipe in line with <br />existing ditch at <br />elevation 0.25' to 0.50' / - -- — --- — <br />below existing flowline---------------- <br />NOTES: <br />1. Flowline of pipe shall be a min of 3" below ditch -F1 11 <br />of 1/2 the diameter of the pipe, below ditch flowline. <br />At an intersection, no driveway shall be placed within 30' <br />point of intersection of the master planned R/W lines. <br />Driveways shall be at right angles to the street. <br />Ditch flowline <br />Material per - <br />chart below <br />A ` Edge <br />Rl_.1R,��_ DRIVEWAY <br />-----�R/W <br />12Min dia cross <br />" <br />pipe when required <br />(See notes 5 & 6) <br />25' R <br />of existing pavement <br />TYPE <br />W <br />STRUCTURAL SEC I lc�i�! <br />PCC <br />(Min) <br />(Max) <br />AC/AB(Min) <br />(Min) <br />Rural <br />Residential <br />12' <br />25' <br />2" 4" <br />Ac/ AB <br />4" <br />Commercial, <br />2" 6" <br />Agricultural and <br />15' <br />40' <br />Ac/ AB <br />6" <br />Industrial <br />pExi Var� Existing I Var <br />avememe"'L pavemen <br />0.5' Min <br />SECTION A -A <br />— — <br />Variable slope (10� max) <br />to meet existing ground <br />2. <br />Circle driveways are to be no closer than 75' between centers (residential) <br />or 80' between centers (commercial). <br />5. When cross pipe is used, it shall extend a minimum of 3' past the toe of fill <br />slopes of the driveway, all fill shall be compacted to 95% relative compaction. <br />Maximum fill slope 2:1. <br />6. Pipes shall be Class 2 (min) RCP, or 0.079" Galvanized Corrugated Steel pipe, <br />the size varies according to the hydraulic requirement. <br />7. Fire access roads and driveways shall comply with the San Joaquin County <br />Fire Chiefs Association, fire access road standards. <br />COUNTYAGRICULTURAL AND HURAL <br />Revision Description <br />r 1•i <br />DEPARTMENT OF PUBLIC WO12,VS <br />Date: DEC 2014 Std. Dwq. No. fl;m'il 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.