My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
GOVT BLDG 16-08 to GOVT BLDG 16-13
PublicWorks
>
VAULT MAPS
>
Government Buildings - GOVT BLDG
>
16
>
GOVT BLDG 16-08 to GOVT BLDG 16-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/4/2024 9:10:57 AM
Creation date
10/1/2024 7:43:59 AM
Metadata
Fields
Template:
Government Buildings - GOVT BLDG
Project
Tipping Floor Repairs (North County and Lovelace)
Limits
North County and Lovelace
Year
2004
Project Engineer
J.C.G.
Supplemental fields
Cross Ref
GOVT BLDG 16-08 to 16-13
Notes
Supplemental Material was Attached in Vault Files
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
GENERAL N O T E S D Q o o RE V� Q T� OO N S �= t TENSION LAP SCHEDULE TM <br />_ <br />7 <br />BEND 2' <br />GENERAL REQUIREMENTS o r c zsoo P51 asoo P51 <br />D A <br />90'BEND N0. TYP. T.B. P. T.B. <br />F <br />135' BEND 2" CLR. #3 18" 24" 14" 18" <br />DETAILS AND DIMENSIONS OF EXISTING CONSTRUCTION SHALL BE VERIFIED CONCRETE PROTECTION FOR REINFORCEM TS (TO FACE OF BARS): STIRRUPS & TIE REINFORCINGxl <br />TMP' #4 24" 32" 18" 24" <br />AT THE SITE BY THE CONTRACTOR AND ANY DISCREPANCY BETWEEN THE 3" WHERE CONCRETE IS POURED AINST EARTH 66, #5 30" 39" 23" 30" <br />PLANS AND EXISTING CONDITION SHALL BE PROMPTLY REPORTED TO THE 2" WHERE CONCRETE IS EXPOSED 0 EARTH BUT PLACED IN FORMS BAR SIZE MIN. BEND DIA. 5 #6 36" 47" 27 35" <br />STRUCTURAL ENGINEER. 1-1/2" FOR COLUMN TIES AND BEAM & GIRDER STIRRUPS #3 THRU #5 4 BAR tl #7 53" 69" 40" 51" <br />#8 60" 78" 45" 59" <br />3/4" FOR SLABS, WALLS AND JOISTS /6 THRU #8 BAR d S S 2 T.B. DENOTES TOP BARS. TOP BARS ARE <br />'2 <br />WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALE. BARS AT TOP OF SLAB OR FOOTING w/ <br />��1d FOR #6 THR 4" MIN. FOR MAS#8 ONRY CONSTRUCTION MORE THAN 12" OF CONC. BELOW THE BAR. <br />DESIGN OF THIS PROJECT 15 BASED ON THE 1997 UBC, SEISMIC ZONE 3 REINFORCING STEEL <br />AND WIND SPEED = 75 MPH, EXPOSURE C. *LAPS NOTED ARE BASED ON CLASS <br />SEE LAP SPLICE & BAR SPACING OF 6"; IF SPACING <br />REINFORCING BARS SHALL CONFORM TO ASTM A615, GRADE 60, EXCEPT - IS LESS THAN 6", INCREASE LAPS BY 8%. <br />THAT GRADE 40 MAY BE USED FOR - _ SCHEDULE ALL LAPS SHALL BE A MIN. OF 12". <br />ALL DRAWINGS ISSUED WITHOUT THE APPROVAL DULY SIGNED AND DATED #3 &SMALLER. N BEND DIAMETER LAP SCHEDULE APPUES TO IS, 60 BARS. <br />} 4tl OR 2Vi2Vi" <br />BY THE BUILDING DEPT. OR WITHOUT THE STAMP AND WET SIGNED BY MINIMUM SINGLE CURTAIN SEE ELEVATIONS OR FOUNDATION PLAN <br />THE ENGINEER OF RECORD SHALL BE CONSIDERED IN THE PRELIMINARY NO SPLICES OF REINFORCEMENT SHALL BE MADE EXCEPT AS DETAILED OR FOR WALL THICKNESS, SIZE AND SPACING <br />MAIN REINFORCING OF VERTICAL AND HORIZONTAL REINF. <br />STAGE AND SHALL NOT BE USED FOR CONSTRUCTION. AUTHORIZED BY THE STRUCTURAL ENGINEER. <br />BAR GRADE I BAR SIZE MIN. BEND DIA. <br />CONSTRUCTION SUPERVISION <br />TIMBER CONSTRUCTION Au cRADEs #3 THRu #B 6 BAR e <br />OF REINFORC'C ig• #10. R11 8 BAR e <br />ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF LOCAL, COUNTY,NOTE; BEND DIAMETER IS MEASURED ON INSIDE OF BAR. <br />STATE & FEDERAL AGENCIES HAVING JURISDICTION. GAMAYO, SANCHEZ D.F.—LARCH SHALL BE GRADED IN ACCORDANCE WITH STANDARD GRADING + ^ <br />& ASSOCIATES ASSUMES NO RESPONSIBILITY FOR THE SUPERVISION OF RULE NO. 17 OF WEST COAST LUMBER INSPECTION BUREAU. I L <br />N.T.S. STANDARD HOOKS N.r.s. REBAR PLACEMENT IN WALL OR FOOTING <br />CONSTRUCTION OR PROPER EXECUTION OF THE WORK SHOWN ON THESE <br />DRAWINGS. SAFELY METHODS AND TECHNIQUES ARE THE SOLE RESPONSIBILITY ALL LUMBER SHALL HAVE A MOISTURE CONTENT NOT TO EXCEED 19% AT <br />THE TIME OF FABRICATION OR INSTALLATION, WHICHEVER OCCURS FIRST. 0 CORNER <br />, <br />OF THE CONTRACTOR. THE CONTRACTOR SHALL PROVIDE ALL MEASURES O CORNERR OFOF <br />NECESSARY TO PROTECT THE STRUCTURE DURING CONSTRUCTION. SUCH OPENING <br />LUMBER GRADES, U.O.N.: PRESSURE -TREATED D.F. NO. 2 2-#5 O HEAD <br />MEASURES SHALL INCLUDE BUT ARE NOT LIMITED TO BRACING, SHORING <br />OF OPENING <br />FOR LOADS DUE TO CONSTRUCTION EQUIPMENT, ETC. OBSERVATION <br />VISITS TO THE SITE BY THE STRUCTURAL ENGINEER SHALL NOT INCLUDE STRUCTURAL ABBREVIATIONS <br />INSPECTION OF THE ABOVE ITEMS. <br />A. R. - ANCHOR ROD F.O.C. - FACE OF CONCRETE 1-6" <br />A.F.F. - ABOVE FINISH FLOOR H.M.D. - HOLLOW METAL DOOR \ <br />IQ FOUNDATION NOTES B.F.F. - BELOW FINISH FLOOR M. B. - ASTM A307 BOLT <br />L" CONC. -CONCRETE (N) - NEW 2-#5 FULL HEIGHT <br />O EA. JAMB <br />ALLOWABLE SOIL PRESSURES: 1500 PSF FOR TOTAL LOAD CONT. - CONTINUOUS N.T.S. - NOT TO SCALE DO 0 ENING <br />D 2000 PSF FOR DEAD LOAD + LIVE D. F. - DOUGLAS FIR P.T. - PRESSURE TREATED <br />i- D LOAD + SEISMIC OR WINO LOAD (E) - EXISTING O.F. -OUTSIDE FACE <br />O E.E. - EACH END RWD. - REDWOOD , �C`U 2-#5 <br />9FOOTING ADJACENT TO EXISTING FOUNDATIONS SHALL PENETRATE SAME E.F. - EACH FACE S. B. - SOLID BLOCKING <br />DEPTH AS EXISTING. U.O.N. ALL FOOTINGS SHALL BEAR ON UNDISTURBED E.S. - EACH SIDE U.O.N. - UNLESS OTHERWISE NOTED U <br />r NEW CONL 'ILL <br />m SOIL OR ENGINEERED FILL A MINIMUM OF 1r BELOW NATURAL OR E.W. - EACH WAY V.I.F. - VERIFY IN THE FIELD O SEE <br />Z FINISHED GRADE, WHICHEVER IS LOWER. e <br />D L E G E N D <br />Fm FOUNDATION WALL BACKFILL SHALL BE BROUGHT UP SIMULTANEOUSLY ON <br />EACH SIDE SO THAT EARTH LEVEL ON ONE SIDE IS NEVER MORE THAN NEW CONCRETE IN SECTION \ <br />#5 TOP BAR TO <br />EIGHT INCHES HIGHER THAN THE OTHER SIDE, UNLESS APPROVED - - - - EXTEND 18" BEYOND <br />NOTE: ONLY ADDITIONAL R"INF. OPENING <br />REINF. IS SHOWN, ScE 1 <br />SHORING IS PROVIDED. ` EXISTING CONCRETE IN SECTION 'ORA <br />& FOOTING <br />® CONTINUOUS WOOD^ e5 NEW FTG. SEE <br />CONCRETE <br />MEMBER IN SECTION 3 REINF. <br />P <br />WOOD BLOCKING NO SCALE ELEVATION NOTE: SEE a FOR DETAILS NOT NOTED <br />CONCRETE SHALL ATTAIN THE FOLLOWING COMPRESSIVE STRENGTHS AT 5 <br />1 SECTION OR DETAIL NO. <br />Y28 DAYS WITH A MINIMUM OF 5 SACKS OF CEMENT PER CUBIC YARD: S1 SHEET NO. WHERE SECT. OR DET. 5 <br />oRFSSECT. ON SAME SHEEiT /a" _ , -a" ADDITIONAL REINF, AT DOOR OPENING <br />TOP SLAB: 4500 PSI <br />ALL OTHER CONCRETE: 3500 PSI SECTION OR DETAIL NO. <br />1 51, S2 SHEET NOS. WHERE DET. <br />" <br />REINFORCEMENTS, ANCHOR BOLTS, PIPE SLEEVES AND OTHER INSERTS IS TAKEN (IF SHOWN) <br />3/4"=1'-0 <br />SHALL BE POSITIVELY SECURED IN PLACE PRIOR TO PLACING CONCRETE. SCALE <br />?,OF ESS/pN <br />o Qx/ �\N Gq �� O <br />No. 1682 m OAU <br />m ^EXP. 3/3Vo5 ©GAMAYO, SANCHEZ <br />z s J & ASSOCIATES, INC. <br />/� � STRUCTURAL & CIVIL ENGINEERS • CONSULTANT. <br />p qA \<OQ\ 555 W. BENJAMIN <br />ENJ MIN HOLT DR. #324 <br />CA 95207 <br />C <br />C (209) 957-2384 4 <br />NO SCALE <br />NORTH COUNTY RECYCLING CENTER TRANSFER STATION TIPPING FLOOR REPAIRS Sheet No. <br />COUNTY OF SAN JOAQUIN <br />AS SHOWN Z WALL EXTENSION <br />GENERAL NOTES AND DETAILS (North County and Lovelace) 6 of 6 <br />DRAWN BY DATE PR ECT ENGINEER DATE CHECKED DATE APPROVAL RECOMMENDED DATE <br />Q.V.P., J.C.G. 3/04 16.c/ 3/04 G.R.G. 3/04 <br />
The URL can be used to link to this page
Your browser does not support the video tag.