Laserfiche WebLink
GRADING PLAN SHEET LAYOUT <br />PLANTING PLAN SHEET LAYOUT <br />P-'1 <br />P-2 - V---'I-- <br />ax x x 'r--, ., -- x <br />-x-x x <br />IRRIGATION PLAN SHEET LAYOUT <br />1-1 <br />1-2 (ZONE 1) <br />N <br />x A <br />0 100 200 <br />SCALE 1'=200' <br />-x-x- - x- r'- - .M -x._, �x--x-x- x - x-x-x-N-X-x-x.rx.._x_x_x---x-x_x-x-x <br />17-7 7 <br />I -Z (ZONE 2) 1-2 (ZONE 3) 1-3 1-3 I-3 OZONES fi & 7) <br />(ZONE 4) (ZONE 5) x <br />x x <br />x x <br />I <br />x <br />- x-x---x-x--x-- - -- <br />A <br />0 100 200 <br />SCALE 1'=200' <br />GENERAL NOTES: <br />1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARITY WITH EXISTING CONDITIONS AND FOR <br />VERIFYING SITE CONDITIONS BEFORE THE START OF CONSTRUCTION. <br />2. "PROPOSED" INDICATES WORK TO BE COMPLETED BY THE CONTRACTOR. <br />3. ALL ELEMENTS OF THIS PROJECT ARE SUBJECT TO MINOR FIELD ADJUSTMENTS AS DIRECTED BY <br />THE ENGINEER. AT ANYTIME, THE CONTRACTOR'S OPERATIONS AND CONSTRUCTION SHALL BE <br />SUBJECT TO INSPECTION BY THE ENGINEER. WHEN REQUESTING THE PRESENCE OF THE ENGINEER <br />AT THE PROJECT SITE FOR DESIGN CLARIFICATION, STAGE ACCEPTANCE, OR OTHER APPROVALS, <br />THE CONTRACTOR SHALL PROVIDE 48 HOURS, MINIMUM, ADVANCE NOTICE TO THE ENGINEER. <br />4. THE CONTRACTOR SHALL CONTACT THE ENGINEER IMMEDIATELY UPON FINDING ANY FIELD <br />CONDITIONS THAT WOULD CONFLICT WITH THE INFORMATION INDICATED ON THESE DRAWINGS. ALL <br />FIELD ADJUSTMENTS MUST BE APPROVED BY THE ENGINEER BEFORE CONSTRUCTION OF SAID <br />ADJUSTMENTS; FAILURE TO DO SO SHALL RESULT IN THE CONTRACTOR ASSUMING FULL <br />RESPONSIBILITY FOR ANY REQUIRED REVISIONS OR FIELD MODIFICATIONS, AS DIRECTED BY THE <br />ENGINEER, AT NO ADDITIONAL COST TO THE COUNTY. <br />5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE SCHEDULING OF <br />CONSTRUCTION OPERATIONS WITH CONSTRUCTION OPERATIONS OF OTHERS WORKING ON OR <br />NEAR THE PROJECT SITE (SUCH AS ONGOING LANDFILL OPERATIONS AND MAINTENANCE). <br />6. THE STAGING AREAS SHALL BE AS INDICATED ON THE DRAWINGS AND AS DIRECTED AND APPROVED <br />BY THE ENGINEER. <br />7. ONLY AN 18 -INCH WALK BEHIND TRENCHER AND VIBRATING PLATE COMPACTOR FOR MINOR TRENCH <br />WORK IS PERMITTED FOR USE WITHIN THE LIMIT OF WORK. UNDER NO CIRCUMSTANCES SHALL ANY <br />OTHER MOTORIZED OR GAS OR ELECTRIC POWERED VEHICLES OR EQUIPMENT BE USED ON THE <br />PROJECT SITE WEST OF THE ENTRANCE ROAD. NO EXCEPTIONS. <br />8. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EXISTING UNDERGROUND UTILITIES BEFORE <br />BEGINNING ANY CONSTRUCTION OPERATIONS. TO FIELD -LOCATE ALL EXISTING UTILITIES, THE <br />CONTRACTOR SHALL CALL UNDERGROUND SERVICE ALERT (U.S.A.) AT 1-(800)-642-2444. THE <br />CONTRACTOR SHALL PROVIDE A MINIMUM OF 72 HOURS ADVANCE NOTICE FOR LOCATING UTILITIES. <br />9. THE REQUIRED CONSTRUCTION INSPECTIONS SHALL BE ACCORDING TO THE SPECIFICATIONS. <br />10. THE CONTRACTOR SHALL CONFORM TO EXISTING GRADES AND CONDITIONS WHEREVER POSSIBLE. <br />ANY ADJACENT OR OFFSITE AREAS DISTURBED BY THE CONTRACTOR'S OPERATIONS MUST BE <br />RESTORED BY THE CONTRACTOR TO THE PREDISTURBANCE CONDITION TO THE SATISFACTION OF <br />THE ENGINEER. <br />11. THE CONTRACTOR SHALL FIELD -MARK THE LIMIT OF WORK FOR APPROVAL BY THE COUNTY'S <br />ENVIRONMENTAL MONITOR AND ENGINEER BEFORE THE START OF CONSTRUCTION OPERATIONS. <br />12. CONTOURS AND SPOT ELEVATIONS SHOWN ON THE DRAWINGS ARE FOR TOP OF BERMS OR CATCH <br />POINTS (AS APPROPRIATE), ALL PLANTING BERMS SHALL BE GRADED ACCORDING TO THE <br />CONTOURS, PROFILES, NOTES, AND DETAILS SHOWN ON THE DRAWINGS AND ACCORDING TO THE <br />SPECIFICATIONS. <br />13. FOR BERM CONSTRUCTION THE CONTRACTOR SHALL PROVIDE SMOOTH TRANSITIONS TO ADJACENT <br />GRADES. EXISTING INFRASTRUCTURE, INCLUDING GAS MONITORING WELLS, SHALL NOT BE <br />DISTURBED DURING CONSTRUCTION. <br />BEST MANAGEMENT PRACTICES: <br />1. THE CONTRACTOR'S WORK SHALL BE LIMITED TO THE WORK AREA. ALL WORK SHALL OCCUR WITHIN <br />THE LIMIT OF WORK. NO WORK SHALL OCCUR OUTSIDE OF THE LIMIT OF WORK THAT IS ADJACENT <br />TO ANY VERNAL FEATURE WITHOUT OVERSIGHT BY THE ENVIRONMENTAL MONITOR, <br />2. VERNAL POOLS AND VERNAL SWALES SHALL NOT BE IMPACTED UNDER ANY CIRCUMSTANCES. NO <br />FOOT TRAFFIC OR OTHER ACTIVITIES RELATED TO CONSTRUCTION SHALL OCCUR WITHIN ANY <br />VERNAL FEATURE. ONLY AN 18 -INCH WALK BEHIND TRENCHER AND VIBRATING PLATE COMPACTOR <br />FOR MINOR TRENCH WORK IS PERMITTED FOR USE WITHIN THE LIMIT OF WORK. NO OTHER <br />MOTORIZED OR GAS OR ELECTRIC POWERED VEHICLES OR EQUIPMENT SHALL BE USED WITHIN THE <br />LIMITS OF WORK OR SOUTH OF THE LIMITS OF WORK. <br />3. STAGING AREAS FOR CONSTRUCTION EQUIPMENT SHALL BE LOCATED SO THAT SPILLS OF OIL, <br />GREASE OR OTHER PETROLEUM BY-PRODUCTS SHALL NOT BE DISCHARGED INTO ANY <br />WATERCOURSE OR SENSITIVE HABITAT. NO REFUELING, STORAGE, SERVICING, OR MAINTENANCE OF <br />EQUIPMENT SHALL TAKE PLACE WITHIN 100 FEET OF ANY VERNAL FEATURES. ALL MACHINERY SHALL <br />BE PROPERLY MAINTAINED AND CLEANED TO PREVENT SPILLS AND LEAKS. ANY SPILLS OF LEAKS <br />FROM EQUIPMENT SHALL BE REPORTED AND CLEANED UP IN ACCORDANCE WITH APPLICABLE <br />LOCAL, STATE AND/OR FEDERAL REGULATIONS. <br />ABBREVIATION LIST <br />APPROX. <br />APPROXIMATELY <br />B.T.U. <br />BRITISH THERMAL UNIT <br />x <br />I <br />x <br />CLEAR <br />CMP <br />CORRUGATED METAL PIPE <br />DIA. <br />DIAMETER <br />GPM <br />x—x—x-x---z <br />GALV. <br />GALVON IZED <br />GS <br />GALVONIZED STEEL <br />G.V. <br />VG <br />HZ <br />HERTZ <br />x� x— x x _` <br />t <br />j..k—x <br />�R-• <br />MAXIMUM <br />MIN. <br />�� <br />OD <br />OUTSIDE DIAMETER <br />+ <br />POINT OF CONNECTION <br />PVC <br />POLYVINYL CHLORIDE <br />PSI <br />POUNDS PER SQUARE INCH <br />RD <br />RELATIVE DENSITY <br />SCH. <br />SCHEDULE <br />S.O.V. <br />SHUT OFF VALVE <br />K <br />TYPICAL <br />I <br />x <br />s <br />x x <br />� <br />I <br />x <br />I <br />X x <br />IIS <br />x <br />} <br />x <br />I <br />x <br />K x <br />I <br />Ir <br />I <br />j <br />0 100 zoo <br />x <br />k <br />SCALE 1'=200' <br />PLANTING PLAN SHEET LAYOUT <br />P-'1 <br />P-2 - V---'I-- <br />ax x x 'r--, ., -- x <br />-x-x x <br />IRRIGATION PLAN SHEET LAYOUT <br />1-1 <br />1-2 (ZONE 1) <br />N <br />x A <br />0 100 200 <br />SCALE 1'=200' <br />-x-x- - x- r'- - .M -x._, �x--x-x- x - x-x-x-N-X-x-x.rx.._x_x_x---x-x_x-x-x <br />17-7 7 <br />I -Z (ZONE 2) 1-2 (ZONE 3) 1-3 1-3 I-3 OZONES fi & 7) <br />(ZONE 4) (ZONE 5) x <br />x x <br />x x <br />I <br />x <br />- x-x---x-x--x-- - -- <br />A <br />0 100 200 <br />SCALE 1'=200' <br />GENERAL NOTES: <br />1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARITY WITH EXISTING CONDITIONS AND FOR <br />VERIFYING SITE CONDITIONS BEFORE THE START OF CONSTRUCTION. <br />2. "PROPOSED" INDICATES WORK TO BE COMPLETED BY THE CONTRACTOR. <br />3. ALL ELEMENTS OF THIS PROJECT ARE SUBJECT TO MINOR FIELD ADJUSTMENTS AS DIRECTED BY <br />THE ENGINEER. AT ANYTIME, THE CONTRACTOR'S OPERATIONS AND CONSTRUCTION SHALL BE <br />SUBJECT TO INSPECTION BY THE ENGINEER. WHEN REQUESTING THE PRESENCE OF THE ENGINEER <br />AT THE PROJECT SITE FOR DESIGN CLARIFICATION, STAGE ACCEPTANCE, OR OTHER APPROVALS, <br />THE CONTRACTOR SHALL PROVIDE 48 HOURS, MINIMUM, ADVANCE NOTICE TO THE ENGINEER. <br />4. THE CONTRACTOR SHALL CONTACT THE ENGINEER IMMEDIATELY UPON FINDING ANY FIELD <br />CONDITIONS THAT WOULD CONFLICT WITH THE INFORMATION INDICATED ON THESE DRAWINGS. ALL <br />FIELD ADJUSTMENTS MUST BE APPROVED BY THE ENGINEER BEFORE CONSTRUCTION OF SAID <br />ADJUSTMENTS; FAILURE TO DO SO SHALL RESULT IN THE CONTRACTOR ASSUMING FULL <br />RESPONSIBILITY FOR ANY REQUIRED REVISIONS OR FIELD MODIFICATIONS, AS DIRECTED BY THE <br />ENGINEER, AT NO ADDITIONAL COST TO THE COUNTY. <br />5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE SCHEDULING OF <br />CONSTRUCTION OPERATIONS WITH CONSTRUCTION OPERATIONS OF OTHERS WORKING ON OR <br />NEAR THE PROJECT SITE (SUCH AS ONGOING LANDFILL OPERATIONS AND MAINTENANCE). <br />6. THE STAGING AREAS SHALL BE AS INDICATED ON THE DRAWINGS AND AS DIRECTED AND APPROVED <br />BY THE ENGINEER. <br />7. ONLY AN 18 -INCH WALK BEHIND TRENCHER AND VIBRATING PLATE COMPACTOR FOR MINOR TRENCH <br />WORK IS PERMITTED FOR USE WITHIN THE LIMIT OF WORK. UNDER NO CIRCUMSTANCES SHALL ANY <br />OTHER MOTORIZED OR GAS OR ELECTRIC POWERED VEHICLES OR EQUIPMENT BE USED ON THE <br />PROJECT SITE WEST OF THE ENTRANCE ROAD. NO EXCEPTIONS. <br />8. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EXISTING UNDERGROUND UTILITIES BEFORE <br />BEGINNING ANY CONSTRUCTION OPERATIONS. TO FIELD -LOCATE ALL EXISTING UTILITIES, THE <br />CONTRACTOR SHALL CALL UNDERGROUND SERVICE ALERT (U.S.A.) AT 1-(800)-642-2444. THE <br />CONTRACTOR SHALL PROVIDE A MINIMUM OF 72 HOURS ADVANCE NOTICE FOR LOCATING UTILITIES. <br />9. THE REQUIRED CONSTRUCTION INSPECTIONS SHALL BE ACCORDING TO THE SPECIFICATIONS. <br />10. THE CONTRACTOR SHALL CONFORM TO EXISTING GRADES AND CONDITIONS WHEREVER POSSIBLE. <br />ANY ADJACENT OR OFFSITE AREAS DISTURBED BY THE CONTRACTOR'S OPERATIONS MUST BE <br />RESTORED BY THE CONTRACTOR TO THE PREDISTURBANCE CONDITION TO THE SATISFACTION OF <br />THE ENGINEER. <br />11. THE CONTRACTOR SHALL FIELD -MARK THE LIMIT OF WORK FOR APPROVAL BY THE COUNTY'S <br />ENVIRONMENTAL MONITOR AND ENGINEER BEFORE THE START OF CONSTRUCTION OPERATIONS. <br />12. CONTOURS AND SPOT ELEVATIONS SHOWN ON THE DRAWINGS ARE FOR TOP OF BERMS OR CATCH <br />POINTS (AS APPROPRIATE), ALL PLANTING BERMS SHALL BE GRADED ACCORDING TO THE <br />CONTOURS, PROFILES, NOTES, AND DETAILS SHOWN ON THE DRAWINGS AND ACCORDING TO THE <br />SPECIFICATIONS. <br />13. FOR BERM CONSTRUCTION THE CONTRACTOR SHALL PROVIDE SMOOTH TRANSITIONS TO ADJACENT <br />GRADES. EXISTING INFRASTRUCTURE, INCLUDING GAS MONITORING WELLS, SHALL NOT BE <br />DISTURBED DURING CONSTRUCTION. <br />BEST MANAGEMENT PRACTICES: <br />1. THE CONTRACTOR'S WORK SHALL BE LIMITED TO THE WORK AREA. ALL WORK SHALL OCCUR WITHIN <br />THE LIMIT OF WORK. NO WORK SHALL OCCUR OUTSIDE OF THE LIMIT OF WORK THAT IS ADJACENT <br />TO ANY VERNAL FEATURE WITHOUT OVERSIGHT BY THE ENVIRONMENTAL MONITOR, <br />2. VERNAL POOLS AND VERNAL SWALES SHALL NOT BE IMPACTED UNDER ANY CIRCUMSTANCES. NO <br />FOOT TRAFFIC OR OTHER ACTIVITIES RELATED TO CONSTRUCTION SHALL OCCUR WITHIN ANY <br />VERNAL FEATURE. ONLY AN 18 -INCH WALK BEHIND TRENCHER AND VIBRATING PLATE COMPACTOR <br />FOR MINOR TRENCH WORK IS PERMITTED FOR USE WITHIN THE LIMIT OF WORK. NO OTHER <br />MOTORIZED OR GAS OR ELECTRIC POWERED VEHICLES OR EQUIPMENT SHALL BE USED WITHIN THE <br />LIMITS OF WORK OR SOUTH OF THE LIMITS OF WORK. <br />3. STAGING AREAS FOR CONSTRUCTION EQUIPMENT SHALL BE LOCATED SO THAT SPILLS OF OIL, <br />GREASE OR OTHER PETROLEUM BY-PRODUCTS SHALL NOT BE DISCHARGED INTO ANY <br />WATERCOURSE OR SENSITIVE HABITAT. NO REFUELING, STORAGE, SERVICING, OR MAINTENANCE OF <br />EQUIPMENT SHALL TAKE PLACE WITHIN 100 FEET OF ANY VERNAL FEATURES. ALL MACHINERY SHALL <br />BE PROPERLY MAINTAINED AND CLEANED TO PREVENT SPILLS AND LEAKS. ANY SPILLS OF LEAKS <br />FROM EQUIPMENT SHALL BE REPORTED AND CLEANED UP IN ACCORDANCE WITH APPLICABLE <br />LOCAL, STATE AND/OR FEDERAL REGULATIONS. <br />ABBREVIATION LIST <br />APPROX. <br />APPROXIMATELY <br />B.T.U. <br />BRITISH THERMAL UNIT <br />CLR <br />CLEAR <br />CMP <br />CORRUGATED METAL PIPE <br />DIA. <br />DIAMETER <br />GPM <br />GALLONS PER MINUTE <br />GALV. <br />GALVON IZED <br />GS <br />GALVONIZED STEEL <br />G.V. <br />GATE VALVE <br />HZ <br />HERTZ <br />LF <br />LINEAR FEET <br />MAX. <br />MAXIMUM <br />MIN. <br />MINIMUM <br />OD <br />OUTSIDE DIAMETER <br />POC <br />POINT OF CONNECTION <br />PVC <br />POLYVINYL CHLORIDE <br />PSI <br />POUNDS PER SQUARE INCH <br />RD <br />RELATIVE DENSITY <br />SCH. <br />SCHEDULE <br />S.O.V. <br />SHUT OFF VALVE <br />TYP, <br />TYPICAL <br />v v <br />a � <br />CD <br />CD o <br />z <br />a 0° <br />❑ o <br />Y <br />w <br />LL <br />z <br />z <br />w <br />m � m <br />Lu <br />� � Y <br />U <br />w ¢ 2 <br />❑ U U <br />N <br />z � <br />�3 <br />Q U <br />0M <br />)M <br />Z <br />Na <br />LL <br />v0 <br />�z <br />W <br />Z <br />°a <br />L)a <br />W <br />in <br />GENERAL <br />NOTES <br />GEN -1 <br />2 OF 11 <br />