Laserfiche WebLink
40 <br />0 <br />by <br />5' <br />190' <br />246' <br />C. GRIFFIN <br />0 <br />C9 <br />C <br />N <br />E <br />N <br />U <br />v <br />a� <br />z <br />C <br />N <br />0 <br />v <br />C <br />v <br />U) <br />R&D exist. column head <br />— ---1 I I <br />F <br />— T- <br />�Iii_-_���---iii <br />NOT TO SCALE <br />5 <br />R&D concrete pedestal <br />R&D 16" casing. <br />Cut off 5'-0", min. <br />below grade and <br />cap with concrete <br />or grout. <br />16" Casing <br />14" Casing <br />11" continuous casing <br />grouted in place <br />130' <br />13' Casing <br />Property Line <br />(TYP•) <br />R&D 2'x5' Conc. <br />o_ Footings <br />(3 each) <br />Li <br />J <br />Q <br />Destroy Well <br />R&D 12" Dia. Steep <br />Pipe Guard Post <br />a: <br />w <br />R&D exist. 2,000 <br />Gallon Pressure <br />Tank & Piping <br />R&D 2 exist. abandoned <br />pipe risers. Cut off <br />\� 24" min. below grade. <br />•A <br />165' <br />1. <br />Contractor shall obtain a well <br />12" Casing <br />destruction permit from the <br />San Joaquin County Environmental <br />Health Department prior to starting <br />any work on the well. <br />197, <br />2. <br />Provide a minimum of 48 hours notice <br />to the Engineer prior to the start <br />of any work. <br />Soft Bottom <br />3. <br />Swab and bale well prior to <br />destruction. Destruction of well shall <br />236' <br />be performed by perforating the well <br />casing with line shot charges and then <br />pressure grouting. <br />246' <br />4. <br />Casing shall be cut off a minimum <br />of 5 feet below the grade and the <br />grout allowed to flow over casing to <br />form a cap. <br />5. <br />Static water level is 83'. <br />Chain—Link fence on FE <br />to remain in place <br />40' <br />6'f <br />R&D Concrete <br />Slab on Grade <br />R&D electric <br />panels <br />24'f <br />R&D Metal Building <br />(Corrugated steel on <br />wood frame) <br />Overhead electric service <br />to be removed by PGI E <br />II I <br />II <br />E. P. <br />II <br />II <br />II <br />II <br />Guy Anchor <br />II _ <br />Power Pole <br />ALLEY <br />4.5' <br />25' <br />R&D existing well piping. <br />Cut at TEE and cap <br />with blind flange. <br />DEMOLITION PLAN <br />SCALE: 1"=4' <br />s9IL PROJECT ENGINEER DATE CHECKED DATE SUBMITTED DATE -APPROVED DATE DEMOLITION PLAN SHEET TOTAL <br />An � 51,11 � �� - _ 1-1-01f COUNTY OF SAN JOAQUIN SCALE AS NOTED (EXISTING WELL NO. -j) VICTOR WATER SYSTEM IMPROVEMENTS NO. SHEETS <br />��isl Oyb7irf � 5 12 <br />I I I I C: \VICTOR\PLAN\DEMOL <br />