Laserfiche WebLink
A . B . C D <br />----------------------------------------------------------------------------- I <br />LEVEL <br />CONTROL ENCLOSURE CONTROLLER MAIN <br />TRANSDUCER i DISCONNECT <br />I <br />i <br />LOW AIR ALARM 3 -WAY PURGE 480V <br />SET @ 25 PSIG i -- 0�0- <br />0-30 PSIG SVl SOLENOID 30 1 <br />ON, 40 PSIG REGULATOR VALVE <br />OFF 75 PSIG PS1 & FILTER ' ---0\O- <br />0-100 PSIG <br />n n SHUTOFF <br />CHI <br />VA! <br />i <br />AIR COMPRESSOR <br />; <br />r ; <br />E <br />AIR O <br />RESERVOIR <br />DRAIN <br />1/4' POLYETHYLENE <br />TUBING (TYP) <br />SHOCK ABSORBER MOUNTS <br />-----------------------------------------------------------------� <br />ROD OUT <br />CONNECTION <br />CABLE TO <br />CONTROL ENCLOSURE <br />STAINLESS STEEL <br />PIPE MOUNT <br />SUPPORT BRACKET <br />HIGH LEVELrl"3' MAX. <br />FLOAT SWITCH <br />II <br />NOTCHED END <br />1/4' IN DEPTH :�:z� O <br />O <br />6' MAXI 00 <br />WETWELL <br />1 FILE: 9404CE13 <br />SCALE <br />NONE <br />PNEUMATIC DIAGRAM <br />1/2' SCHEDULE 80 <br />PVC PIPE (TYP> <br />PVC CLAMPS <br />SECURED WITH <br />TWO STAINLESS <br />STEEL CONCRETE <br />ANCHORS <br />(TYP) <br />LEVEL CONTROLLER <br />MICROMAC, RUGID <br />OR APPROVED EQUAL <br />42' <br />(MAX) <br />DEVICES <br />LOCATED ON <br />INNER DEAD <br />FRONT DOOR <br />(TYP) <br />CONDUITS THROUGH CABLE GRIPS <br />SIDE OF STRUCTURE (TYP) <br />(TYP) <br />DATE' <br />AUGUST 1994 DESIGNED RLV SUBMITTED <br />FILE DRAWN ZKV RECOMMENI <br />1 CHEC:KieD _ ?InV APPROVED <br />CABLES <br />BUBBLER <br />PIPE <br />PUMP #1 <br />DISCONNECT <br />M1 <br />70 <br />I ' <br />I <br />0 <br />I I <br />0.—�'E <br />PUMP #2 <br />DISCONNECT <br />n M2 <br />70 I <br />0--i F <br />I I <br />0 <br />I <br />70 0__ f <br />PUMP #3 <br />DISCONNECT <br />M3 <br />I I <br />0— f <br />NEMA 4R <br />ENCLOSURE <br />I Ic. o <br />®DEWANTE AND STOWELL <br />CONSULTING ENGINEERS <br />SACRAMENTO. CALIFORNIA <br />E <br />[fix] <br />OVERLOAD <br />14. <br />01.2 <br />OVERLOAD <br />1Z <br />OL3 <br />OVERLOAD <br />2Q <br />0 <br />aa® o <br />Ir,I LOCKABLE <br />DISCONNECT <br />0 0 <br />5 ® AIR <br />COMPRESSOR <br />© El <br />3/ <br />BO <br />SI <br />OUT FROM WALL <br />WITH GALVANIZED <br />UNISTRUT <br />F <br />01 _ <br />RAW SEWAGE 02 _ <br />PUMP #1 <br />03 _ <br />04 _ <br />05 _ <br />RAW SEWAGE 06 _ <br />PUMP #2 <br />07 _ <br />08 _ <br />09 _ <br />RAW SEWAGE 10 _ <br />PUMP #3 <br />11 _ <br />12 _ <br />13 _ <br />14 _ <br />15 _ <br />16 _ <br />17 _ <br />18 _ <br />19 _ <br />20 _ <br />21 _ <br />22 _ <br />23 _ <br />24 _ <br />25 _ <br />CONTROL PANEL "RSP" ELEVEATION <br />(PROVIDE WIRE #'S ON ALL PANEL WIRES) <br />FLAG CITY <br />SAN JOAQUIN CO.. CALIFORNIA <br />WASTEWATER TREATMENT FACILITIES <br />i <br />G <br />REVISION <br />150VA <br />120V _I <br />LEVEL <br />:CONTROLLER: <br />1L N/ <br />L N <br />ISR <br />1 <br />40 HA <br />PSI PSI <br />LA <br />F2 IB�}-Zvi-� <br />H DA <br />, <br />d <br />I <br />14 > <br />TRI <br />H 0, A <br />H 0.A <br />Pz�( J <br />TRI <br />P3�� <br />TRI <br />LEVEL CONTROLLER <br />SHALL HAVE BUILT-IN <br />TIME DELAYS TO STAGGER <br />PUMP RESTART AFTER POWER FAIL <br />DESCRIPTION <br />1N <br />3 TDOD <br />SET @ 2 MIN, <br />4 <br />5 <br />evil <br />12 °L1 13 M 1 <br />REMOVE JUMPER <br />FOR INSERTION <br />OF MOTOR <br />OVER -TEMP <br />22 0L2 23 <br />32 u" 33 <br />:I <br />BY I APP I DATE <br />LEVEL CONTROLLER <br />POWER SUPPLY <br />INTRINSIC SAFE <br />RELAY POWER <br />HIGH LEVEL ALARM RELAY <br />Z 21 <br />HIGH LEVEL <br />FLOAT SWITCH <br />BACKUP PUMP CONTROL RELAY <br />1.61 12 E2 <br />ALARM RELAY <br />24 <br />HIGH LEVEL <br />ALARM <br />LOW AIR <br />PRESSURE SWITCH <br />LOW LEVEL <br />ALARM <br />PURGE SOLENOID <br />VALVE <br />PUMP 1 STARTER <br />IalRI;w-w L•l t*N <br />PUMP 3 STARTER <br />6 <br />CRI CR2---------- AN PANEL <br />7 ANNUNCIATOR <br />WIRE & <br />TERMINAL #'S <br />(TYP) <br />CONTROL PANEL "RSP" ELEMENTARY <br />RAW SEWAGE PUMP CONTROL <br />NAMEPLATE SCHEDULE <br />31 <br />NUMBER <br />1 <br />ENGRAVING <br />CONTROL PANEL "RSP" <br />DISCONNECT <br />SIZE LIES 32 <br />1/8" <br />2 <br />RAW SEWAGE PUMP #1 <br />DISCONNECT <br />33 <br />1/8" <br />3 <br />RAW SEWAGE PUMP #2 <br />DISCONNECT <br />1/8" <br />4 <br />RAW SEWAGE PUMP #3 <br />DISCONNECT <br />1/8- <br />5 <br />LEVEL CONTROLLER <br />1/8" <br />6 <br />RAW SEWAGE PUMP #1 <br />HOA <br />1/8- <br />/8"7 <br />7 <br />RAW SEWAGE PUMP #2 <br />HOA <br />1/8" <br />8 <br />RAW SEWAGE PUMP #3 <br />HOA <br />1/8- <br />9 <br />CONTROL PANEL "RSP" <br />1/2" <br />DATE' <br />AUGUST 1994 DESIGNED RLV SUBMITTED <br />FILE DRAWN ZKV RECOMMENI <br />1 CHEC:KieD _ ?InV APPROVED <br />CABLES <br />BUBBLER <br />PIPE <br />PUMP #1 <br />DISCONNECT <br />M1 <br />70 <br />I ' <br />I <br />0 <br />I I <br />0.—�'E <br />PUMP #2 <br />DISCONNECT <br />n M2 <br />70 I <br />0--i F <br />I I <br />0 <br />I <br />70 0__ f <br />PUMP #3 <br />DISCONNECT <br />M3 <br />I I <br />0— f <br />NEMA 4R <br />ENCLOSURE <br />I Ic. o <br />®DEWANTE AND STOWELL <br />CONSULTING ENGINEERS <br />SACRAMENTO. CALIFORNIA <br />E <br />[fix] <br />OVERLOAD <br />14. <br />01.2 <br />OVERLOAD <br />1Z <br />OL3 <br />OVERLOAD <br />2Q <br />0 <br />aa® o <br />Ir,I LOCKABLE <br />DISCONNECT <br />0 0 <br />5 ® AIR <br />COMPRESSOR <br />© El <br />3/ <br />BO <br />SI <br />OUT FROM WALL <br />WITH GALVANIZED <br />UNISTRUT <br />F <br />01 _ <br />RAW SEWAGE 02 _ <br />PUMP #1 <br />03 _ <br />04 _ <br />05 _ <br />RAW SEWAGE 06 _ <br />PUMP #2 <br />07 _ <br />08 _ <br />09 _ <br />RAW SEWAGE 10 _ <br />PUMP #3 <br />11 _ <br />12 _ <br />13 _ <br />14 _ <br />15 _ <br />16 _ <br />17 _ <br />18 _ <br />19 _ <br />20 _ <br />21 _ <br />22 _ <br />23 _ <br />24 _ <br />25 _ <br />CONTROL PANEL "RSP" ELEVEATION <br />(PROVIDE WIRE #'S ON ALL PANEL WIRES) <br />FLAG CITY <br />SAN JOAQUIN CO.. CALIFORNIA <br />WASTEWATER TREATMENT FACILITIES <br />i <br />G <br />REVISION <br />150VA <br />120V _I <br />LEVEL <br />:CONTROLLER: <br />1L N/ <br />L N <br />ISR <br />1 <br />40 HA <br />PSI PSI <br />LA <br />F2 IB�}-Zvi-� <br />H DA <br />, <br />d <br />I <br />14 > <br />TRI <br />H 0, A <br />H 0.A <br />Pz�( J <br />TRI <br />P3�� <br />TRI <br />LEVEL CONTROLLER <br />SHALL HAVE BUILT-IN <br />TIME DELAYS TO STAGGER <br />PUMP RESTART AFTER POWER FAIL <br />DESCRIPTION <br />1N <br />3 TDOD <br />SET @ 2 MIN, <br />4 <br />5 <br />evil <br />12 °L1 13 M 1 <br />REMOVE JUMPER <br />FOR INSERTION <br />OF MOTOR <br />OVER -TEMP <br />22 0L2 23 <br />32 u" 33 <br />:I <br />BY I APP I DATE <br />LEVEL CONTROLLER <br />POWER SUPPLY <br />INTRINSIC SAFE <br />RELAY POWER <br />HIGH LEVEL ALARM RELAY <br />Z 21 <br />HIGH LEVEL <br />FLOAT SWITCH <br />BACKUP PUMP CONTROL RELAY <br />1.61 12 E2 <br />ALARM RELAY <br />24 <br />HIGH LEVEL <br />ALARM <br />LOW AIR <br />PRESSURE SWITCH <br />LOW LEVEL <br />ALARM <br />PURGE SOLENOID <br />VALVE <br />PUMP 1 STARTER <br />IalRI;w-w L•l t*N <br />PUMP 3 STARTER <br />6 <br />CRI CR2---------- AN PANEL <br />7 ANNUNCIATOR <br />WIRE & <br />TERMINAL #'S <br />(TYP) <br />CONTROL PANEL "RSP" ELEMENTARY <br />RAW SEWAGE PUMP CONTROL <br />DESCRIPTION <br />ON <br />OFF <br />LEAD PUMP <br />2.5 <br />1.0 <br />LAG PUMP <br />3.8 <br />1.8 <br />FOLLOW PUMP <br />4.3 <br />3.3 <br />HIGH LEVEL FLOAT <br />6.0 <br />-- <br />ALL LEVELS ARE LISTED <br />IN FEET FROM BOTTOM <br />WETWELL <br />OF <br />RAW SEWAGE PUMPS <br />CONTROL PANEL "RSP" <br />RECORD DRAWING <br />3123 BROADWAY <br />SACRAMENTO, CA. 95817 <br />916-457-8144 <br />DRAWING NUMBER SHEET NUMBER <br />E -13 43 of 44 <br />4 <br />3 <br />2 <br />1 <br />