n <br />GROUND BUS <br />CONCRETE PAD WITH <br />#4 O 12" CENTERS <br />REINFORCING STEEL -� <br />BOTH WAYS <br />1' (MIN) <br />3/8" DIA. x 5" LENGTH - <br />302 STAINLESS STEEL <br />WEDGE EXPANSION ANCHOR <br />INSTALL TWO PER <br />COMPARTMENT SECTION <br />B . C <br />GROUND RING <br />BUSHING <br />PLYABLE SEALING COMPOUND AROUND <br />WIRING TO PREVENT MOISTURE, GAS, OR INSECTS <br />FROM ENTERING THE ENCLOSURE <br />EQUIPMENT FRAME <br />SHIM AS REQUIRED <br />TO LEVEL <br />4" SKIRT ON ALL EXPOSED <br />SIDES OF ENCLOSURE <br />BUILDING FLOOR OR GRADE <br />-\, USE FACTORY I <br />�r�__---_H - <br />TWO EACH 4/0 BARE COPPER <br />BONDING WIRES TO <br />UFFER GROUND AND <br />STATION PIPING <br />CONCRETE PAD DETAIL "A" <br />NOT TO SCALE <br />#4/0 AWG BARE COPPER <br />GROUNDING ELECTRODE <br />FINISHED GRADE <br />SPACE AT 12" INTERVALS <br />ALTERNATING PLACEMENT FROM SIDE <br />TO SIDE OF U -SHAPED LOOP <br />3' (MIN) (TYPICAL) <br />r� •r.r� r�r• r�r �r�• <br />SECTION <br />" D" <br />FILE: 9404C -E3 <br />SCALE <br />01 <br />NONE <br />24" <br />MIN. <br />— TYPICAL CONDUIT <br />ENTRY <br />MOTOR CONTROL CENTER <br />COPPER GROUND BUS <br />#8 REBAR• • • <br />SUPPORTS <br />CONCRETE WITH STEEL <br />ENCASEMENT TIE WIRE CONNECTED WITH <br />(TYP) U.L. GROUND CLAMPS <br />r�r�T},♦••.T <br />U - SHAPED #4/0 AWG - <br />BARE COPPER GROUNDING <br />ELECTRODE ATTACHED <br />TO REBAR SUPPORTS <br />CONCRETE— <br />ENCASEMENT <br />6" <br />3" 3" <br />g, <br />ENCASEMENT <br />SECTION "D" <br />DATE <br />AUGUST 1994 DESIGNED RLV SUBMITTED _ <br />FILE DRAWN ZKY RECOMMENDED <br />CHECKED RLV APPROVED — <br />4/0 BARE COPPER <br />BOND WIRE <br />7 <br />1 2' (MIN) <br />6" <br />UFFER GROUND DETAIL "D" <br />NOT TO SCALE <br />4/0 BARE COPPER <br />BOND WIRE TO <br />STATION PIPING <br />I <br />D A E <br />Y�li]:il�L�-LPfI <br />TRANSITION TO <br />ABOVE GRADE "E" <br />FINISHED GRADE <br />CONDUIT BURIED IN EARTH COMPACTED <br />WITH NO SUPPLEMENTAL EARTH <br />PROTECTION BACKFILL <br />THREADED <br />COUPLING <br />OR PVC TO RIGID <br />CONDUIT ADAPTER <br />8" <br />(MIN) <br />iglimAlligoo <br />NOUNS <br />J <br />3" RED WARNING <br />TAPE LABELLED <br />"ELECTRIC LINE' <br />[•i•P►1�19�1 <br />6" <br />(MIN) <br />RIVER " <br />MIN DOFIL2" (MIN) I� <br />ALL AROUND <br />EACH CONDUIT <br />SECTION "E" <br />UNDERGROUND CONDUIT TRENCH DETAIL "B" <br />NOT TO SCALE <br />(a DEWANTE AND STOWELL <br />CONSULTING ENGINEERS <br />SACRAMENTO, CALIFORNIA <br />MOTOR CONNECTIO <br />LIQUID - TIGHT FLEXII <br />CONDUITS do CONNECT <br />TO MOTOR CONNEC11C <br />JUNCTION BOX <br />36" (MAX) <br />MOTOR CONNECTION DETAIL "E" <br />NOT TO SCALE <br />FLAG CITY <br />SAN JOAQUIN CO.. CALIFORNIA <br />WASTEWATER TREATMENT FACILITIES <br />PUMP BASE <br />F <br />O A <br />REVISION DESCRIPTION <br />FINISHED GRADE <br />�i <br />(MIN) <br />_= STATE <br />SIZE 5 <br />(MIN) <br />i <br />i <br />NOTE: <br />ADD EXTENSIONS <br />WHERE NECESSARY <br />TO RAISE COVER <br />TO FINISHED GRADE <br />3/4" CRUSHED <br />CONDUIT ENTRANCES COVER PLATE <br />(TYPICAL) <br />PULL BOX DETAIL "C" <br />NOT TO SCALE <br />3" (MIN) <br />24" <br />(MAX) <br />FINISHED GRADE <br />0/\O/\ <br />OnOn <br />H <br />SLOPE ALL CONDUITS <br />TOWARD PULLBOX <br />END BELL <br />(TYPICAL) <br />f- 6" (MIN) <br />1 B" <br />(MIN) <br />2" THICK CONCRETE (MIN) <br />BY I APP I DATE <br />GRS-PVC CONDUITS <br />SEPERATED BY SPACERS <br />UNDERGROUND CONDUITS DETAIL "F" <br />(FOR CONDUITS BETWEEN PULL BOXES) <br />NOT TO SCALE <br />RECORD DRAWING <br />MISCELLANEOUS DETAILS <br />3123 BROADWAY <br />SACRAMENTO, CA. 95817 <br />AIE 916-457-8144 <br />DRAWING NUMBER SHEET NUMBER <br />E-3 33 OF 44 <br />0 <br />4 <br />3 <br />F� <br />