Laserfiche WebLink
p <br />dr <br />I <br />A . B <br />GENERAL NOTES <br />IGDSFILE.94055]51, GEN <br />I. TYPICAL DETAILS AND NOTES SHALL APPLY UNLESS OTHERWISE SHOWN OR NOTED ON <br />PLANS. <br />2. DETAILS OF CONSTRUCTION NOT FULLY SHOWN SHALL BE OF THE SAME NATURE AS SHOWN <br />FOR SIMILAR CONDITION. <br />3. CONSTRUCTION SHALL CONFORM TO ALL APPLICABLE CODES AND REGULATIONS. <br />4. PRIOR TO FABRICATION; SHOP DRAWINGS SHALL BE SUBMITTED FOR REVIEW BY THE <br />ENGINEER ON ALL STRUCTURAL STEEL AND REINFORCING STEEL. <br />SHOP DRAWINGS: CONTRACTOR AGREES THAT SHOP DRAWING SUBMITTALS PROCESSED BY THE <br />ENGINEER ARE NOT CHANGE ORDERS AND THAT THE PURPOSE OF SHOP DRAWING SUBMITTALS <br />BY THE CONTRACTOR IS TO DEMONSTRATE TO THE ENGINEER THAT THE CONTRACTOR <br />UNDERSTANDS THE DESIGN CONCEPT BY INDICATING WHICH MATERIAL HE INTENDS TO <br />FURNISH AND INSTALL AND BY DETAILING THE FABRICATION AND INSTALLATION METHODS <br />HE INTENDS TO USE. <br />5. SAFETY NOTE: <br />A) IT IS THE CONTRACTOR'S RESPONSIBILITY TO COMPLY WITH THE PERTINENT SECTIONS <br />OF THE "CONSTRUCTION SAFETY ORDERS" ISSUED BY THE STATE OF CALIFORNIAr LATEST <br />EDITIONP AND ALL OSHA REQUIREMENTS AS THEY APPLY TO THIS PROJECT. <br />B) THE ENGINEER AND THE OWNER DO NOT ACCEPT ANY RESPONSIBILITY FOR THE <br />CONTRACTOR'S FAILURE TO COMPLY WITH THESE REQUIREMENTS. <br />C) THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATE DESIGN AND CONSTRUCTION OF <br />ALL FORMS AND SHORING REQUIRED. <br />6. CONTRACTOR SHALL VERIFY ALL DIMENSIONS) ELEVATIONSP PROPERTY LINES) ETC. ON <br />THE JOB. <br />7. CONTRACTOR SHALL NOTIFY THE ENGINEER WHERE A CONFLICT OCCURS ON ANY OF THE <br />CONTRACT DRAWINGS OR DOCUMENTS. CONTRACTOR IS NOT TO ORDER MATERIAL OR <br />CONSTRUCT ANY PORTION OF STRUCTURES THAT IS IN CONFLICT UNTIL CONFLICT IS <br />RESOLVED WITH THE AFFECTED PARTIES. <br />CONSTRUCTION LOADS <br />IGDSFILE.94055]SI, LOADS <br />STRUCTURES HAVE BEEN DESIGNED FOR OWNER'S OPERATIONAL LOADS ON THE FINISHED <br />STRUCTURES. DURING CONSTRUCTION, THE STRUCTURES SHALL BE PROTECTED BY BRACING <br />AND BALANCING WHEREVER EXCESSIVE CONSTRUCTION LOADS MAY OCCUR. BACKFILL SHALL <br />BE PLACED AROUND STRUCTURES SYMMETRICALLY AND UNIFORMLY SO THAT LOADS AGAINST <br />STRUCTURES ARE INTRODUCED IN BALANCE. LIQUID -CONTAINING STRUCTURES SHALL BE <br />TESTED FOR WATER -TIGHTNESS BEFORE BACKFILLING - SEE SPECS. <br />INSPECTION NOTES <br />[GDSFILE.9d0557S1, INSP <br />I. GENERAL: INSPECTOR SHALL BE PRESENT DURING THE OPERATIONS LISTED BELOW. <br />2. CONCRETE: DURING THE TAKING OF TEST SPECIMENS AND PLACING OF ALL REINFORCED <br />CONCRETE AND PNEUMATICALLY PLACED CONCRETE. <br />3. REINFORCING STEEL: <br />Al DURING THE PLACING OF REINFORCING STEEL FOR ALL STRUCTURAL CONCRETE. <br />B) DURING PLACING OF ALL INSERTS. <br />4. WELDING: DURING ALL STRUCTURAL WELDING, INCLUDING WELDING OF REINFORCING <br />STEEL. <br />FOUNDATIONS <br />[GDSFILE.94055151, FOUND <br />I. REFER TO RECOMMENDATIONS IN GEOTECHNICAL REPORT BY J.H. KLEINFELDER & <br />ASSOCIATES, FILE NO. 20-2662-04, DATED DECEMBER 20, 1988. <br />2. BEARING SOIL IS CLASSIFIED AS ENGINEERED FILL WITH AN ALLOWABLE <br />BEARING PRESSURE OF 3500 PSF D.L. + L.L. <br />3000 PSF D.L. + L.L. ............. ELECTRICAL BUILDING <br />8000 PSF D.L. + L.L. ............. PUMP STATION <br />3. BOTTOM ELEVATION OF FOOTINGS NOTED THUS ON FOUNDATION PLAN: -(2 <br />4. THE FOOTINGS SHALL BEAR ON FIRM, DRY OR ENGINEERED FILL WITH A <br />MINIMUM PENETRATION OF 18 INCHES. SEE GEOTECH REPORT. <br />5. EXCAVATIONS SHALL BE CLEANED OF ALL DEBRIS. STANDING WATER SHALL BE REMOVED. <br />6. ALL FOOTINGS SHALL BE FORMED. FOUNDATIONS MAY BE PLACED IN NEAT EXCAVATIONS <br />PROVIDED WRITTEN PERMISSION IS OBTAINED FROM THE ENGINEER AND FOOTINGS <br />ARE INCREASED 2" IN WIDTH. SEE TYPICAL DETAIL. <br />7. NOTIFY THE ENGINEER 48 HOURS BEFORE PLACING FOUNDATIONS. <br />WATERSTOPS FOR CONCRETE CONST. <br />EGDSFILE.94055]Sll WATER <br />I. ALL WATER STOPS SHALL BE INSTALLED ACCORDING TO THE MANUFACTURERS SPECIFICATIONS <br />TO GIVE A WATERTIGHT JOINT. <br />2. WATER STOPS SHALL BE CAREFULLY POSITIONED IN PLACE AND SUPPORTED AS REQUIRED <br />TO REMAIN IN PLACE DURING OPERATIONS. <br />3. WATERSTOPS MUST BE USED WHERE LIQUID OR EARTH RETAINING STRUCTURES ARE ADJACENT <br />TO DRY AREAS OF THE STRUCTURE AND WHERE LIQUID RETAINING STRICTURES ARE EXPOSED <br />TO 1'HE EXTERIOR. <br />4. LIQUID RETAINING STRUCTURES MUST BE TESTED FOR WATER TIGHTNESS (SEE SPECS). <br />WATERSTOPS MAY BE USED TO ASSURE WATERTIGHTNESS AT CONTRACTOR'S OPTION. <br />C <br />CONCRETE AND REINFORCING STEEL <br />[GDSFIL .94055751, CONC <br />1. CONCRETE CONSTRUCTION SHALL CONFORM TO ACI 318-89. <br />2. THE MINIMUM 28 DAY STRENGTH AND TYPE OF CONCRETE SHALL BE AS FOLLOWS: <br />ALL NON-STRUCTURAL CONCRETE .................150 PCF, F'c = 2500 PSI <br />CONCRETE FOR LIQUID -CONTAINING STRUCTURES .. 150 PCF, F'c = 3500 PSI <br />ALL OTHER STRUCTURAL CONCRETE ............... 150 PCF, F'c = 3000 PSI <br />3. CEMENT SHALL CONFORM TO ASTM C-150 TYPE 11. <br />4. CONCRETE AGGREGATES: NATURAL SAND AND ROCK AGGREGATES CONFORMING TO ASTM <br />C-33. <br />5. REINFORCING SHALL CONFORM TO ASTM A615 GRADE 60, EXCEPT STIRRUPS AND TIES <br />SHALL BE GRADE 40. <br />6. WELDING OF REINFORCING STEEL SHALL CONFORM TO AWS D1.4 USING PROPER LOW <br />HYDROGEN ELECTRODES. TACK WELDING TO REBAR IS STRICTLY PROHIBITED. SEE "REBAR <br />WELDING". <br />T. REINFORCING STEEL SHALL BE DETAILED, FABRICATEDi AND INSTALLED ACCORDING TO <br />MANUAL OF STANDARD PRACTICE FOR REINFORCED CONCRETE CONSTRUCTION" BY WCRS1. <br />8. WIRE FABRIC SHALL CONFORM TO ASTM A-185. <br />9. DIMENSIONS SHOWN FOR LOCATION OF REINFORCING ARE TO THE FACE OF MAIN BARS <br />AND DENOTE CLEAR COVERAGE. UNLESS OTHERWISE NOTED, CONCRETE COVERAGE SHALL BE <br />AS FOLLOWS: <br />CONCRETE DEPOSITED DIRECTLY AGAINST GROUND <br />(EXCEPT SLABS) ................................................. 3" <br />FORMED CONCRETE EXPOSED TO WEATHER OR GROUND OR <br />LIQUID -- #6 AND LARGER ....................................... 2" <br />#5 AND SMALLER .................................. 1-1/2" <br />BEAMS (TOP BARS) ............................................ 1-1/2" <br />BEAMS (ALL OTHER MAIN REINFORCING) .............................. 2" <br />COLUMN MAIN REINFORCING ........................................ 2" <br />WALLS AND SLABS (INTERIOR DRY FACES) .......................... 3/4" <br />SLABS ON GROUND WITH ONE LAYER OF <br />REINFORCEMENT .......................... POSITION IN CENTER OF SLAB. <br />10. A) ALL BARS SHALL HAVE A CLASS B MINIMUM SPLICE LAP UNLESS OTHERWISE <br />NOTED. SEE "REINFORCEMENT LAP SPLICES IN INCHES". <br />B) DOWEL ALL VERTICAL REBARS IN WALLS AND COLUMNS FROM FOUNDATION WITH SAME <br />SIZE BAR. <br />C) SPLICES IN ADJACENT BARS SHALL BE NOT LESS THAN 5'-0" APART. <br />D) SPLICE CONTINUOUS BARS IN SOIL -BEARING GRADE BEAMS AS FOLLOWS: BOTTOM BARS <br />AT MID -SPAM TOP BARS AT CENTERLINE OF SUPPORT, UNLESS NOTED OTHERWISE. <br />E) SPLICE CONTINUOUS BARS IN BEAMS, SPANDRELSi WALL BEAMS ETC. AS FOLLOWS: <br />BOTTOM BARS AT CENTERLINE OF SUPPORTY TOP BARS AT MIDSPAN, UNLESS NOTED <br />OTHERWISE. <br />F) REINFORCING BARS SHALL BE RUN IN A MANNER THAT FORMS A CONTINUOUS SYSTEM OF <br />BARS TYING ALL PARTS OF THE STRUCTURE TOGETHER. EXTEND ALL REINFORCING BARS AS <br />FAR AS POSSIBLE IN EACH CONCRETE MEMBER AND TERMINATE BAR TO PROVIDE 2" OF <br />CONCRETE COVER OVER END OF BAR OR FACE OF BEND. <br />G) BEAM STIRRUPS AND COLUMN TIES SHALL HOOK 135 DEGREES AROUND A CORNER BAR <br />UNLESS OTHERWISE SHOWN. <br />11. GENERAL: <br />A) NO PIPES OR DUCTS SHALL BE PLACED IN CONCRETE SLABS, BEAMS] WALLS OR GRADE <br />BEAMS UNLESS SPECIFICALLY DETAILED. <br />B) REFER TO ARCHITECTURAL, STRUCTURALS AND MECHANICAL DRAWINGS FOR ALL <br />OPENINGS, FLANGESi MOULDS] GROOVES) CLIPS AND GROUNDS TO BE CAST IN CONCRETE. <br />12. CONSTRUCTION JOINTS SHALL BE MADE ROUGH AND ALL LAITANCE REMOVED FROM THE <br />SURFACE. CONCRETE MAY BE ROUGHENED BY CHIPPING THE ENTIRE SURFACE, <br />SANDBLASTING, OR HOSING THE SURFACE 4 TO 6 HOURS AFTER THE POUR WITH A FINE <br />SPRAY. <br />13. REMOVE ALL DEBRIS FROM THE FORMS BEFORE PLACING ANY CONCRETE. <br />14. REINFORCING, DOWELS; BOLTSi ANCHORS,' SLEEVESi ETC. TO BE EMBEDDED IN <br />CONCRETE SHALL BE SECURELY POSITIONED BEFORE PLACING CONCRETE. OBTAIN APPROVAL <br />OF ALL. AFFECTED TRADES PRIOR TO PLACING CONCRETE. <br />15. MAXIMUM FREE FALL OF CONCRETE SHALL BE 4'-0". <br />16. WALLS SHALL BE PLACED IN HORIZONTAL LAYERS OF 2'-0" MAX. DEPTH. <br />17. CONCRETE IN WALLS, PIERSi OR COLUMNS SHALL SET AT LEAST 2 HOURS BEFORE <br />PLACING CONCRETE IN BEAMS, SPANDRELSi OR SLABS SUPPORTED THEREON. <br />18. REINFORCE ALL SLABS ON GRADE AS SHOWN ON DRAWINGS. <br />19. HORIZONTAL WALL BARS IN DOUBLE LAYER WALLS SHALL BE STAGGERED. USE #2 <br />SPREADERS APPROXIMATELY EVERY THIRD INTERSECTION EACH DIRECTION FOR ALL DOUBLE <br />LAYER WALLS. PLACE SPREADERS IN VERTICAL LINES WITH FORM TIES. <br />20. NO WOOD SPREADERS ARE ALLOWED. NO WOOD STAKES ARE ALLOWED IN AREAS TO BE <br />CONCRETED. <br />21. MINIMUM WALL REINFORCING SHALL BE: <br />WALL THICKNESS SINGLE LAYER DOUBLE LAYER <br />7" OR LESS ............. #4 AT 12" cc E.W. <br />8" ..................... #4 AT 10" cc E.W. <br />9" AND 10" ...................................... #4 AT 16" cc E.W. <br />11" AND 12" ..................................... #4 AT 12" cc E.W. <br />22. CONCRETE MIX DESIGN SHALL BE SUBMITTED FOR ENGINEER'S REVIEW PRIOR TO <br />PLACING CONCRETE. <br />23. NOTIFY THE ENGINEER 48 HOURS PRIOR TO PLACING CONCRETE. <br />REBAR WELDING <br />[GDSFILE.94055]SI, REWELD <br />ALL REBAR TO BE WELDED SHALL BE CONTINUOUSLY INSPECTED BY A QUALIFIED <br />LABORATORY. CONTRACTOR MUST FURNISH TO THE LABORATORY MILL CERTIFICATES <br />SHOWING CHEMICAL ANALYSIS. ALL PREHEATING AND WELDING SHALL BE DONE IN <br />ACCORDANCE WITH AWS D1.4 STANDARDS (LATEST EDITION). <br />E <br />F <br />G <br />MASONRY <br />[GDSFILE.94055151, MAS <br />I. CONCRETE BLOCK UNITS SHALL CONFORM TO ASTM C-90 GRADE N, TYPE I WITH <br />1900 PSI MIN. COMPRESSIVE STRENGTH. F'm = 1500 PSI. <br />2. MORTAR SHALL BE TYPE S CONFORMING TO UBC STANDARD 24-20; 1800 PSI. <br />3. GROUT SHALL CONFORM TO UBC 1991 WITH 2000 PSI MINIMUM. <br />4. REINFORCING STEEL SHALL BE THE SAME AS NOTE 5 UNDER CONCRETE. <br />5. LAP ALL BARS 48 BAR DIAMETERS. <br />6. DRILL THROUGH STEEL BEAMS TO PASS REBAR 11" DIA. MAXIMUM). <br />7. BEFORE BLOCK IS PLACED ON CONCRETEi THOROUGHLY CLEAN CONCRETE OF ALL <br />LAITANCE AND ALL LOOSE MATERIAL. ROUGHEN AS IN A CONCRETE CONSTRUCTION JOINT. <br />8. CONCRETE BLOCK MASONRY SHALL BE BUILT TO PRESERVE THE UNOBSTRUCTED CONTINUITY <br />OF THE VERTICAL CELLS. WALLS AND CROSS WEBS SHALL BE FULL BEDDED IN MORTAR <br />GROUT. ALL HEAD OR END JOINTS SHALL BE SOLIDLY FILLED WITH MORTAR FOR A <br />DISTANCE IN FROM THE FACE OF THE WALL OR UNIT NOT LESS THAN THE THICKNESS OF <br />THE LONGITUDINAL FACE SHELLS. <br />9. VERTICAL CELLS SHALL HAVE VERTICAL ALIGNMENT SUFFICIENT TO <br />MAINTAIN A CLEAR UNOBSTRUCTED; CONTINUOUS VERTICAL CELL MEASURING NOT LESS THAN <br />2" x 3". <br />10. CLEAN OUT OPENINGS SHALL BE PROVIDED AT THE BOTTOMS OF ALL CELLS TO BE <br />FILLED AT EACH LIFT OR POUR OF GROUT WHERE SUCH LIFT OR POUR OF GROUT IS IN <br />EXCESS OF 4'-0" IN HEIGHT. ANY OVERHANGING MORTAR OR OTHER OBSTRUCTION OR <br />DEBRIS SHALL BE REMOVED FROM INSIDE OF SUCH CELLS. THE CLEANOUTS SHALL BE <br />SEALED AFTER INSPECTION AND BEFORE GROUTING. <br />II. VERTICAL REINFORCING SHALL BE HELD IN POSITION AT TOP AND BOTTOM AND AT <br />INTERVALS NOT EXCEEDING 192 BAR DIAMETERS. <br />12. WHEN GROUTING IS STOPPED FOR ONE HOUR OR LONGER; HORIZONTAL CONSTRUCTION <br />JOINTS SHALL BE FORMED BY STOPPING THE POUR 1-1/2" BELOW THE TOP OF THE <br />UPPERMOST UNIT. <br />13. PLACE ALL HORIZONTAL BARS IN BOND BEAM UNITS. WHEN 2 BARS ARE USED; <br />STAGGER LAPS 6'-0" MINIMUM. <br />14. PROVIDE DOWEL TO FOUNDATION OF EQUAL DIAMETER AND 48 BAR DIAMETER LAP TO <br />EACH VERTICAL BAR IN WALLS, PIERS, COLUMNS, ETC. DOWELS SHALL BE <br />STRAIGHT AND PLUMB. <br />15. ALL CONCRETE BLOCK UNITS SHALL BE OPEN END BOND BEAM UNITS. <br />STRUCTURAL STEEL SUBMIT SHOP DRAWINGS BEFORE FABRICATING) <br />10SFILE.94OSSIS1, STEEL <br />I. FABRICATION, ERECTION AND MATERIALS SHALL CONFORM WITH THE AISC <br />SPECIFICATION FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR <br />BUILDINGS AND UBC, 1991 EDITION. <br />2. STRUCTURAL STEEL SHALL CONFORM TO ASTM A-36. <br />3. PIPE COLUMNS SHALL CONFORM TO ASTM A53, TYPE E OR Si GRADE B. <br />4. TUBE COLUMNS SHALL CONFORM TO ASTM A500, GRADE B. <br />5. WELDING SHALL BE DONE BY THE ELECTRIC ARC PROCESS IN ACCORDANCE WITH "AWS" <br />STANDARDS, USING ONLY CERTIFIED WELDERS. ALL BUTT WELDS SHALL HAVE COMPLETE <br />PENETRATION. ALL EXPOSED BUTT WELDS SHALL BE GROUND. <br />6. PLACE NON -SHRINK GROUT UNDER ALL BEARINGS ON CONCRETE OR MASONRY BEFORE <br />ADDING VERTICAL LOAD. <br />T. ALL STRUCTURAL STEEL SHALL BE ERECTED PLUMB AND TRUE TO LINE. TEMPORARY <br />BRACING SHALL BE INSTALLED AND SHALL BE LEFT IN PLACE UNTIL OTHER MEANS IS <br />PROVIDED TO ADEQUATELY BRACE THE STRUCTURE. <br />8. HOLES FOR BOLTS SHALL BE OF THE SAME NOMINAL DIAMETER AS THE BOLT PLUS 1/16". <br />9. USE STANDARD AISC GAGE AND PITCH FOR BOLTS EXCEPT AS NOTED OTHERWISE. <br />10. PROVIDE 1/2" DIAMETER STITCH BOLTS AND RING FILLS, SPACED AT NOT MORE THAN <br />2'-0" ON CENTERS FOR ALL DOUBLE ANGLE MEMBERS. <br />11. WRAP STRUCTURAL STEEL EMBEDDED IN CONCRETE WITH 6X6-W1.4Xw1.4 E.W.F. DO <br />NOT PAINT EMBEDDED AREAS. <br />12. HIGH STRENGTH BOLTS SHALL BE 3/4" DIA. ASTM A-325 F U.N.O. SEE <br />SPECIFICATIONS. <br />WELDING -REQUIREMENTS <br />EGDSFILE.94055151, WELD <br />I. WELDING SHALL BE DONE BY THE ELECTRIC ARC OR THE ELECTRO -FLUX PROCESS IN <br />ACCORDANCE WITH "A.S.M.E." STANDARDS, USING ONLY CERTIFIED WELDERS. ALL BUTT <br />WELDS SHALL HAVE COMPLETE PENETRATION. ALL WELDS SHALL BE CLEANED OF SLAG <br />BEFORE GALVANIZING. <br />REINFORCEMENT LAP SPLICES IN INCHES <br />rGDSF1LE.QAOSS1S1, RFINF <br />BAR SIZE <br />#4 <br />#4 1 #5 1 #6 1 #7 1 #8 1 #9 11 #10 # I I <br />SPLICE <br />F'c (PSI) <br />GR 40 <br />GRADE 60 <br />CLASS <br />B <br />18 <br />28 <br />35 <br />42 <br />49 <br />59 <br />74 <br />94 <br />116 <br />TOPBARS <br />ARS <br />14 <br />22 <br />27 <br />32 <br />38 <br />45 <br />57 <br />73 <br />89 <br />BOTT <br />BARS <br />CLASS <br />B <br />17 <br />26 <br />32 <br />39 <br />45 <br />54 <br />69 <br />87 <br />107 <br />TOPBARS <br />ARS <br />13 <br />20 <br />25 <br />30 <br />35 <br />42 <br />53 <br />67 <br />83 <br />BOTT <br />BARS <br />TOP BARS REFERS TO ANY HORIZONTAL REINFORCEMENT SO PLACED THAT MORE THAN 12" OF <br />CONCRETE IS CAST IN THE MEMBER BELOW THE REINFORCEMENT. <br />VISI <br />DESCRIPTION <br />H <br />BY I APP I DATE <br />ABBREVIATIONS <br />1GDSF1LE.940551S1r ABBR <br />ADDNL. ............... ADDITIONAL <br />A.B. ................. AGGREGATE BASE <br />ARCH . ................ ARCHITECTURAL <br />BETW. ................ BETWEEN <br />BEV . ................. BEVELED <br />BM . .................. BEAM <br />BOTT. ................ BOTTOM <br />BRG. ................. BEARING <br />CHKD. ................ CHECKERED PLATE <br />CLR. ................. CLEAR <br />CL . .................. CENTER LINE <br />C.0 . ................. CENTER TO CENTER <br />C.M.0. ............... CONCRETE MASONRY UNIT <br />COL . ................. COLUMN <br />CONC. ................ CONCRETE <br />CONSTR JT. ........... CONSTRUCTION JOINT <br />CONT. (CONTIN.)....... CONTINUOUS <br />C.J. ................. CONTROL JOINT (CONTRACTION JOINT) <br />DIA . ................. DIAMETER <br />DIM . ................. DIMENSION <br />DN . .................. DOWN <br />EA . .................. EACH <br />E.F. ................. EACH FACE <br />E.J. ................. EXPANSION JOINT <br />EL. (ELEV.) .......... ELEVATION <br />E.W.F. ............... ELECTRICALLY WELDED FABRIC <br />EQ . .................. EQUAL <br />E.N. ................. EDGE NAILIING <br />E.S. ................. EDGE OF SLAB <br />E.W. ................. EACH W',Y <br />F.B. ................. FACE OF BLOCK <br />F.0 . ................. FACE OF CONCRETE <br />F.D. ................. FLOOR DRAIN <br />FIN. FLR. ............ FINISHED FLOOR <br />FIN. GRD . ............ FINISHED GRADE <br />FLG. ................. FLANGE <br />FTG . ................. FOOTING <br />GA . .................. GAGE <br />G.A.F. ............... GALVANIZE AFTER FABRICATION <br />GALV. ................ GALVANIZED <br />H.R. ................. HAND RAIL <br />H.A. ................. HEADED ANCHOR <br />H . ................... HIGH <br />H.S.B. ............... HIGH STRENGTH BOLT <br />HORIZ. ............... HORIZONTAL <br />K.P. ................. KICK PLATE <br />L. ................... LONG <br />L.S. ................. LAG SCREW <br />MANUF. ............... MANUFACTURER <br />MAX . ................. MAXIMUM <br />M.B. ................. MACHINE BOLT <br />MECH. ................ MECHANICAL <br />MIN . ................. MINIMUM <br />N.T.S. ............... NOT TO SCALE <br />O.H. ................. OPPOSITE HAND <br />PL. .. PLATE <br />REINF. ............... REINFORCING <br />DIA . ................. ROUND, DIAMETER <br />REQ'D. ............... REQUIRED <br />SIM . ................. SIMILAR <br />S.S. ................. STAINLESS STEEL <br />STIFF . ............... STIFFENER <br />STAB . ................ STAGGER <br />SO . .................. SQUARE <br />SYM. ................. SYMMETRICAL <br />T & B ................ TOP AND BOTTOM <br />T.O.B. ............... TOP OF BLOCK <br />T.O.0. ............... TOP OF CONCRETE <br />T.S. ................. TOP OF SLAB <br />T.O.S. ............... TOP OF STEEL <br />T.W. ................. TOP OF WALL <br />TYP. ................. TYPICAL <br />U.N.O. (U.O.N.) ...... UNLESS NOTED OTHERWISE <br />VERT . ................ VERTICAL <br />W.S. ................. WATERSTOP <br />W . ................... WIDE <br />W.P. ................. WORKING POINT <br />L .' <br />ti"' YMlam H. Richard_ <br />NO. 1610 <br />Exa. 63091 <br />StNctural Engineer <br />Cole/Yee/Schubert k Associates <br />`5�Y WW Structural Engineers, Incorporated <br />Suite 2500 Venture Oaks Way <br />RECORD DRAWING <br />Sacramento, <br />95 <br />to, Ca. 833 918/920-2020 <br />20 <br />SCALE DATE DESIGNED STH SUBMITTEDDEWANTE AND STOWELL FLAG CITY DRAW" NUMBER SWEET NUMBER <br />AUGUST 1994 <br />NONE DRAWN LEL RECOMMENDED SAN JOAOU I N CO., CALIFORNIA TYPICAL STRUCTURAL NOTES <br />PLE CHECKED WHR APPROVED CONSULTING ENGINEERS WASTEWATER TREATMENT FACILITIES <br />93423 1 SACRAMENTO, CALIFORNIA ' 22 OF 44 <br />S <br />L <br />3 <br />N <br />