ABBREVIATION DESCRIPTION <br />A AREA <br />AB AGGREGATE BASE <br />ABN ABANDON <br />AC ASPHALT CONCRETE <br />ADJ ADJUST <br />AG AGRICULTURAL <br />ALT ALTERNATIVE <br />ANG ANGLE <br />APPROX APPROXIMATE <br />ARV AIR RELEASE VALVE <br />AVE AVERAGE / AVENUE <br />AWR ALL WEATHER ROAD <br />BC BEGIN HORIZONTAL CURVE <br />BG BEGIN <br />BK BACK <br />BKF BACKFILL <br />BLDG BUILDING <br />BM BENCH MARK <br />BO BLOW OFF <br />BVC BEGIN VERTICAL CURVE <br />BW BACK OF WALK / BARBED WIRE <br />C/C CENTER TO CENTER <br />CALC CALCULATE <br />CB CATCH BASIN <br />CF CUBIC FOOT <br />CHNL CHANNEL <br />CIP CAST IRON PIPE / CAST IN PLACE <br />CIPCP CAST IN PLACE CONCRETE PIPE <br />CL CENTERLINE / CHAIN LINK / CLASS <br />CLR CLEAR / CLEARANCE <br />CMP CORRUGATED METAL PIPE <br />CMU CONCRETE MASONRY UNIT <br />CO CLEAN OUT <br />CONC CONCRETE <br />COND CONDUIT <br />CONST CONSTRUCTION <br />CORD COORDINATE <br />CORP U.S. CORPS OF ENGINEERS <br />CR CURB RETURN / CREEK <br />CRSP CONCRETE ROCK SLOPE PROTECTION <br />CTS CATHODIC TEST STATION <br />CU CUBIC <br />CULV CULVERT <br />CY CUBIC YARD <br />D DEPTH / DIAMETER <br />DBL DOUBLE <br />DEG DEGREE <br />DET DETAILS <br />DF DOUGLAS FUR <br />DFL DITCH FLOW UNE <br />DG DECOMPOSED GRANITE <br />DI DROP INLET <br />DIA DIAMETER <br />DIFF DIFFERENCE <br />DIP DUCTILE IRON PIPE <br />DIST DISTANCE <br />DN DOWN <br />DR DRAIN OR DRIVE <br />DWG DRAWING <br />DWY DRIVEWAY <br />(E) EXISTING <br />E EAST / EASTING <br />EA EACH <br />EC END HORIZONTAL CURVE <br />EG EXISTING GRADE / FOR EXAMPLE <br />EL ELEVATION <br />ELEC ELECTRICAL <br />EMB EMBANKMENT <br />EP EDGE OF PAVEMENT <br />ER END OF RETURN <br />ES EDGE OF SHOULDER <br />ESMT EASEMENT <br />EVC END VERTICAL CURVE <br />EXC EXCAVATION <br />EXIST EXISTING <br />EXP JT EXPANSION JOINT <br />F & C FRAME AND COVER <br />F & G FRAME AND GRATE <br />FD FOUND <br />FDN FOUNDATION <br />FG FINISHED GRADE <br />FH FIRE HYDRANT <br />FL FLOW LINE <br />FS FORESIGHT OR FINISHED SURFACE <br />FT FOOT / FEET <br />FTG FOOTING <br />FW FLOODWALL <br />G GAS <br />GALV GALVANIZED <br />GB GRADE BREAK <br />GI GALVANIZED IRON <br />GL GRADEUNE OR GROUND LINE <br />GR GRADE / GRATE / GUARD RAILING <br />GRND GROUND <br />GSP GALVANIZED STEEL PIPE <br />H HEIGHT <br />HORIZ HORIZONTAL <br />HP HINGE POINT OR HORSE POWER <br />HW HEADWALL <br />HWY HIGHWAY <br />IB IMPORTED BORROW <br />INCL INCLUDE <br />ID INSIDE DIAMETER <br />1 pW-GLI-GVVV <br />U <br />ABBREVIATION DESCRIPTION <br />ABBREVIATION DESCRIPTION <br />IE INVERT ELEVATION <br />IN INCH <br />INTX INTERSECTION <br />INV INVERT <br />IP IRON PIPE <br />IR IRON ROD <br />IRR IRRIGATION <br />JP JOINT POLE <br />JS JUNCTION STRUCTURE <br />JT JOINT <br />L LENGTH / LEFT <br />LAT LATITUDE <br />LB POUND <br />LD LANDSCAPE DRAIN <br />LEV LEVEL <br />LF LINEAR FOOT <br />LN LANE <br />LOC LOCATION <br />LOL LAYOUT LINE <br />LON LONGITUDE <br />LS LUMP SUM <br />LT LEFT <br />LYT LAYOUT <br />M METER <br />MATL MATERIAL <br />MAX MAXIMUM <br />MEAS MEASURE <br />MED MEDIAN <br />MH MANHOLE <br />MI MILES <br />MID MIDDLE <br />MIN MINIMUM <br />MISC MISCELLANEOUS <br />MKR MARKER <br />MN MAIN <br />MOD MODIFIED <br />MON MONUMENT <br />MSNRY MASONRY <br />MTL MATERIAL <br />MTR METER <br />NN) NEW <br />NORTH / NORTHING <br />N/A NOT APPLICABLE <br />NAPOTS NOT A PART OF THIS SURVEY <br />NAT NATURAL <br />NB NORTHBOUND <br />NE NORTHEAST <br />NGS NATIONAL GEOLOGIC SURVEY <br />NIC NOT IN CONTRACT <br />NO NUMBER <br />NORM NORMAL <br />NTS NOT TO SCALE <br />NW NORTHWEST <br />OC ON CENTER / OVERCROSSING <br />OFF OFFSET <br />OG ORIGINAL GROUND <br />OH OVERHEAD <br />ORIG ORIGINAL <br />OUT OUTLET <br />PB PULL BOX <br />PBM PRECISE BENCH MARK <br />PC POINT ON CURVE / PORTLAND CEMENT <br />PCC POINT OF COMPOUND CURVE <br />PCP PERFORATED CONCRETE PIPE <br />PCVC POINT OF COMPOUND VERTICAL CURVE <br />PERP PERPENDICULAR <br />PG PROFILE GRADE <br />PI POINT OF INTERSECTION <br />PL PROPERTY LINE / PLATE <br />POB POINT OF BEGINNING <br />POC POINT ON HORIZONTAL CURVE <br />POT POINT ON TANGENT <br />POVC POINT ON VERTICAL CURVE <br />PP POWER POLE <br />PRC POINT OF REVERSE CURVE <br />PRI PRIMARY <br />PRVC POINT OF REVERSE VERTICAL CURVE <br />PT POINT <br />PUE PUBLIC UTILITY EASEMENT <br />PVC POLYVINYL CHLORIDE <br />PVMT PAVEMENT <br />R RADIUS / RADIAL / RIGHT <br />R&D REMOVE AND DISPOSE <br />RB REBAR <br />RCP REINFORCED CONCRETE PIPE <br />RD ROAD <br />REF REFERENCE <br />REINF REINFORCED / REINFORCING <br />REL RELOCATE / RELOCATED <br />REM REMOVABLE / REMOVED <br />RET REVISION <br />REV REVISED <br />RND ROUND <br />RP REFERENCE POINT <br />RR RAILROAD <br />RSP ROCK SLOPE PROTECTION <br />RT RIGHT / ROUTE <br />RVS REVERSE <br />RW RIGHT—OF—WAY / RETAINING WALL <br />S SLOPE / SOUTH <br />S/M SELECTED MATERIAL <br />SALV SALVAGE <br />SB SOUTHBOUND / SLIP BASE (SIGNAL) <br />SBM STANDARD BENCH MARK DISK <br />SCH SCHEDULE <br />SD STORM DRAIN <br />SDG SOUNDING <br />SDMH STORM DRAIN MANHOLE <br />SE SOUTHEAST <br />SEC SECTION <br />SEP SEPARATION <br />SF SQUARE FOOT <br />SFN SEARCH FOUND NOTHING <br />SG SUBGRADE <br />SGL SINGLE <br />SHLD SHOULDER <br />SHT SHEET <br />SIG SIGNAL <br />SL SEA LEVEL / SECTION LINE <br />SM SELECTED MATERIAL <br />SMH SANITARY SEWER MANHOLE <br />SP STAND PIPE / SERVICE POINT <br />SPEC SPECIAL / SPECIFICATION <br />SPK SPIKE <br />SQ SQUARE <br />SQFT SQUARE FOOT <br />SQYD SQUARE YARD <br />SS SANITARY SEWER <br />ST STREET <br />STA STATION <br />STD STANDARD <br />STK STAKE <br />STL STEEL <br />STOR STORAGE <br />STIR STRUCTURE <br />STIR GR STRAIGHT GRADE <br />SURF SURFACING <br />SW SIDEWALK / SOUTHWEST <br />SWR SEWER <br />SY SQUARE YARD <br />SYS SYSTEM <br />T SEMI—TANGENT <br />TAN TANGENT <br />TB THRUST BLOCK <br />TBM TEMPORARY BENCH MARK <br />TC TOP OF CURB <br />TCB TRAFFIC CONTROL BOX <br />TEL TELEPHONE <br />TEMP TEMPORARY <br />TFW TOP OF FLOODWALL <br />TG TOP OF GRATE <br />TH TEST HOLE <br />TMBR TIMBER <br />TOT TOTAL <br />TP TURNING POINT <br />TRANS TRANSITION <br />TRW TOP OF RETAINING WALL <br />TYP I TYPICAL <br />TYP SEC TYPICAL SECTION <br />UD UNDERDRAIN <br />UGRD UNDERGROUND <br />UNMKD UNMARKED <br />UP UNDERPASS / UTILITY POLE <br />USA UNDERGROUND SERVICE ALERT <br />USC&GS UNITED STATES COAST & GEODETIC SURVEY <br />USGS UNITED STATES GEODETIC SURVEY <br />UTL UTILITY <br />V VALVE <br />VAL VALLEY <br />VAR VARIABLE <br />VB VALVE BOX <br />VC VERTICAL CURVE <br />VCP VITRIFIED CLAY PIPE <br />VERT VERTICAL <br />VLT VAULT <br />VM VALVE & METER <br />VOL VOLUME <br />VP VENT PIPE <br />VPI VERTICAL POINT OF INTERSECTION <br />W WEST / WIDTH <br />W/ WITH <br />W/0 WITH OUT <br />WB WESTBOUND <br />WD WOOD <br />WH WEEP HOLE <br />WK WALK <br />WL WATER METER <br />WM WIRE MESH <br />WP WATER PUMP / WEATHER PROOF <br />WRG WIRING <br />WS WATER SURFACE <br />WV WATER VALVE <br />WWF WELDED WIRE FABRIC <br />XFMR TRANSFORMER <br />XING CROSSING <br />YR YEAR <br />XS CROSS SECTION <br />YD YARD <br />& AND <br />PER <br />% PERCENT <br />FEET <br />" INCHES <br />X BY <br />® AT <br />CHECKED BY: rJ*^�^ -- 7/1/17 <br />TE <br />,��CC _, QD,A/ <br />ORIGINAL SCALE IN INCHES SENIOR ENGINEER: r"� �.G{ _5(1Lt7 <br />FOR REDUCED PLAN "' DATE <br />7/� <br />APPROVAL RECOMMENDED: f 7 <br />0 1 2 3 DATE <br />GENERAL NOTES <br />1. ALL NEW IMPROVEMENTS SHALL BE IN ACCORDANCE WITH THE <br />REQUIREMENTS OF THESE PLANS AND SPECIFICATIONS, THE LATEST <br />EDITION OF THE COUNTY OF SAN JOAQUIN STANDARDS <br />AND THE STATE OF CALIFORNIA DEPARTMENT OF TRANSPORTATION <br />(CALTRANS) STANDARD SPECIFICATIONS AND PLANS (1992). <br />2. THE INTENT IS THAT THESE PLANS REQUIRE ALL LABOR AND MATERIALS <br />(EXCEPT AS SPECIFIED) NECESSARY AND PROPER FOR THE WORK <br />CONTEMPLATED AND THAT THE WORK BE COMPLETED IN ACCORDANCE <br />WITH THEIR TRUE INTENT AND PURPOSE. CONTRACTOR SHALL NOTIFY <br />ENGINEER IMMEDIATELY REGARDING ANY DISCREPANCIES AND AMBIGUITIES <br />WHICH MAY EXIST IN THE PLANS OR SPECIFICATIONS. IF THE PIANS <br />DESCRIBE PORTIONS OF THE WORK IN GENERAL TERMS BUT NOT IN COMPLETE <br />DETAIL, IT IS UNDERSTOOD THAT ONLY THE BEST GENERAL PRACTICE IS TO <br />PREVAIL AND THAT ONLY MATERIALS AND WORKMANSHIP OF THE FIRST <br />QUALITY ARE TO BE USED. <br />3. THE TYPES, LOCATION, SIZES AND/OR DEPTHS OF EXISTING UNDERGROUND <br />UTILITIES AS SHOWN ON THESE PLANS WERE OBTAINED FROM "OUTSIDE <br />SOURCES". CONTRACTOR IS CAUTIONED THAT ONLY ACTUAL EXCAVATION <br />WILL REVEAL THE TYPES, EXTENT, SIZES, LOCATION, AND DEPTHS OF SUCH <br />UNDERGROUND UTILITIES; HOWEVER, KJELDSEN, SINNOCK & NEUDECK INC. <br />CAN ASSUME NO RESPONSIBILITY FOR THE COMPLETENESS OR ACCURACY OF <br />ITS DELINEATION OF SUCH UNDERGROUND UTILITIES WHICH MAY BE <br />ENCOUNTERED BUT WHICH ARE NOT SHOWN ON THESE DRAWINGS. <br />4. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION OF <br />ALL EXISTING UNDERGROUND UTILITIES AND SHALL CONTACT THE RESPECTIVE <br />UTILITY COMPANIES PRIOR TO COMMENCEMENT OF WORK. CONTRACTOR SHALL <br />BE RESPONSIBLE FOR THE LOCATION AND PRESERVATION OF ALL SUCH <br />FACILITIES IN THE AREA OF CONSTRUCTION, AND SHALL NOTIFY UTILITY <br />COMPANIES TWENTY-FOUR HOURS IN ADVANCE OF ANY CONSTRUCTION. <br />(UNDERGROUND SERVICE5. CONTRACTOR'S ATTENTION ALERTIS( 800DIRECTED TOOSECTION 1540 (A)(1) OF THE <br />CONSTRUCTION SAFETY ORDERS (TITLE 8 CALIFORNIA ADMINISTRATION CODE <br />SECTION 1540), ISSUED BY THE OCCUPATIONAL SAFETY AND HEALTH <br />STANDARDS BOARD PURSUANT TO THE CALIFORNIA OCCUPATIONAL SAFETY <br />AND HEALTH ACT OF 1973, AS AMENDED, WHICH STATES: <br />PRIOR TO OPENING AN EXCAVATION, EFFORT SHALL BE MADE TO DETERMINE <br />WHETHER UNDERGROUND INSTALLATION: I.E., SEWER, WATER, FUEL, ELECTRIC <br />LINES, ETC., WILL BE ENCOUNTERED AND, IF SO, WHERE SUCH UNDERGROUND <br />INSTALLATIONS ARE LOCATED. WHEN THE EXCAVATION APPROACHES THE <br />APPROXIMATE LOCATION OF SUCH AN INSTALLATION, THE EXACT LOCATION <br />SHALL BE DETERMINED BY CAREFUL PROBING OR AND DIGGING; AND WHEN IT <br />IS UNCOVERED, ADEQUATE PROTECTION SHALL BE PROVIDED FOR THE EXISTING <br />INSTALLATION. ALL KNOWN OWNERS OF UNDERGROUND FACILITIES IN THE <br />AREA CONCERNED SHALL BE ADVISED OF PROPOSED WORK AT LEAST 48 HOURS <br />PRIOR TO THE START OF ACTUAL EXCAVATION. <br />6. CONTRACTOR SHALL PROVIDE SHORING, BRACING, SLOPING OR PROVISIONS <br />TO PROTECT WORKMEN FOR ALL AREAS TO BE EXCAVATED TO A DEPTH OF FIVE <br />FEET OR MORE. SAID PROTECTION TO BE DONE IN ACCORDANCE WITH THE <br />REQUIREMENTS OF LOCAL, STATE, AND FEDERAL REGULATIONS (CAL -OSHA, OSHA). <br />7. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF THE REMOVAL <br />AND/OR RELOCATION OF ALL EXISTING UTILITIES WITH RESPECTIVE UTILITY <br />COMPANIES. <br />8. ASBESTOS CEMENT MATERIALS SHALL NOT BE USED IN THE CONSTRUCTION OF <br />ANY FACILITIES WITHIN THIS PROJECT. <br />9. CONTRACTOR SHALL BE RESPONSIBLE FOR MATCHING EXISTING SURROUNDING <br />LANDSCAPE AND OTHER IMPROVEMENTS WITH A TRANSITION IN PAVING, CURBS, <br />GUTTERS. SIDEWALKS, GRADES, ETC., AND TO AVOID ANY ABRUPT OR APPARENT <br />CHANGES IN CROSS SLOPES, LOW SPOTS OR HAZARDOUS CONDITIONS. <br />10. ENGINEER ASSUMES NO RESPONSIBILITY FOR FINAL GRADE OF CONCRETE <br />UNLESS FORMS ARE CHECKED BY THE ENGINEER PRIOR TO ANY CONCRETE PLACEMENT. <br />11. CONTRACTOR SHALL BE HELD RESPONSIBLE FOR ANY FIELD CHANGES MADE <br />WITHOUT WRITTEN AUTHORIZATION FROM ENGINEER. <br />12. CONTRACTOR SHALL PROVIDE ALL LIGHTS, SIGNS, BARRICADES, FLAGMEN, OR <br />OTHER DEVICES NECESSARY TO PROVIDE FOR PUBLIC SAFETY IN ACCORDANCE WITH <br />THE CITY OF STOCKTON. CALTRANS, AND CAL -OSHA SPECIFICATIONS. <br />13. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO THE SITE AND <br />SURROUNDING AREAS RESULTING FROM OPERATIONS PRIOR TO ACCEPTANCE OF <br />CONTRACTOR'S WORK. <br />14. DURING CONSTRUCTION CONTRACTOR SHALL MAINTAIN THE INTEGRITY OF <br />EXISTING FACILITIES. CONTRACTOR IS RESPONSIBLE TO REPAIR, TO THE <br />SATISFACTION OF THE COUNTY OF SAN JOAQUIN. ANY FACILITIES DAMAGED <br />DURING CONSTRUCTION AT NO COST TO THE COUNTY. <br />15. WHERE EXISTING FENCES ARE TO BE REMOVED FOR CONSTRUCTION <br />PURPOSES, CONTRACTOR SHALL REMOVE AND REPLACE THE FENCING IN KIND. <br />WHERE THE EXISTING FENCE IS USED FOR PROPERTY SECURITY AND/OR <br />CONTAINMENT, CONTRACTOR SHALL ERECT TEMPORARY FENCING DURING <br />(NOT SHOWN ON PLANS) CONSTRUCTION AS SHOWN HERON OR AS DIRECTED <br />BY THE OWNERS REPRESENTATIVE. <br />16. THE PROJECT ROUGH GRADING IS NOT INTENDED TO BALANCE. THE <br />CONTRACTOR IS RESPONSIBLE FOR ANY IMPORT AND/OR OFF HAUL TO BALANCE <br />THE SITE. <br />17. ENGINEER SHALL PREPARE "RECORD DRAWINGS" OF IMPROVEMENTS FROM <br />CONTRACTOR PROVIDED "REDLINE DRAWINGS". <br />18. CONTRACTOR SHALL POSSESS A CLASS A LICENSE AT THE TIME <br />THIS CONTRACT IS AWARDED. <br />19. THE CONTRACTOR SHALL ONLY DO WORK WITHIN THE STREAM ZONE DURING <br />PERIODS OF LOW STREAM FLOW AND DRY WEATHER AND SHALL BE CONFINED <br />TO THE PERIOD OF APRIL 15 TO NOVEMBER 15. <br />20. CONTRACTOR SHALL ABIDE BY THE STREAMBED ALTERATION AGREEMENT <br />CONTAINED AS AN APPENDIX WITHIN THE SPECIFICATIONS. <br />} BENCH MARK <br />SYMBOL <br />DESCRIPTION <br />WORK POINT OR <br />BENCH MARK <br />DETAIL INDICATOR <br />t DETAIL IDENTIFICATION NUMBER <br />2 3 SHEET WHERE DETAIL IS SHOWN <br />SHEET DETAIL IS TAKEN FROM <br />REVISION <br />1Q REVISION NUMBER <br />SECTION INDICATOR <br />t SECTION IDENTIFICATION NUMBER <br />2 3 SHEET WHERE SECTION IS DRAWN <br />SHEET SECTION IS TAKEN FROM <br />NOTE INDICATOR <br />NOTE NUMBER AS INDICATED <br />NEW <br />f <br />EXISTING <br />DESCRIPTION <br />GATE <br />FENCE <br />GUARD RAIL / BARRICADE <br />A LIGHT <br />o"" MAINTENANCEHOLE <br />o • UTILITY POLE <br />POST / BOLLARD <br />SIGN <br />o CONTROL MONUMENT <br />20.9 SPOT ELEVATION <br />0 UTILITY BOX <br />STORM DRAIN LINE <br />(ARROW DEPICTS FLOW DIRECTION) <br />T� SANITARY SEWER LINE <br />(ARROW DEPICTS FLOW .DIRECTION) <br />42"W WATER UNE <br />G GAS UNE <br />T COMMUNICATION LINE <br />BRASS DISK MARKING CITY OF STOCKTON TRAVERSE CONTROL <br />MONUMENT STAMPED "2N-11" IN MONUMENT BOX IN THE <br />TRAFFIC ISLAND IN THE CENTER OF WEST LANE AT THE RECORD p <br />SOUTHEAST CORNER OF THE SOUTHBOUND BRIDGE OVER THE RAWI N U _ <br />CALAVERAS RIVER. ITS NORTHING/EASTING IS 2184807.01/6334886.17 <br />& ITS ELEV = 28.56. NGVD 1929 DATUM, 1996 COS ADJUSTMENT. Corrections By <br />No Changes By <br />Date 3ltlly�� <br />A <br />Ry Person Using This Drawing Should VprlfyNOTE: r <br />CONTRACTOR SHALL ABIDE BY THE NATIONWIDE PERMIT NO. 12 DOCUMENTATION nfnrmatl0n By InSpeCllng The Site Of WOIk L <br />CONTAINED AS AN APPENDIX WITHIN THE SPECIFICATIONS. <br />DOW I a/ <br />K KJELDSEN. <br />S SINNOCK <br />N NEUDECK <br />INC. Consulting Engineers <br />and Land Surveyors <br />Post Office Box 844 <br />1113 W. Fremont Street <br />Stockton, CA 95201-0844 <br />(209) 946-0268 <br />OH ELECTRICAL LINE <br />C CONDUIT <br />SWALE / DITCH <br />WEST LANE HEIGHTS <br />PUMPING PLANT EXPANSION <br />LEGEND & GENERAL NOTES <br />DEPARTMENT OF PUBLIC WORKS <br />CITY OF STOCKTON, CALIFORNIA <br />NO SCALE APPROVED BY: <br />D BY: MRC DA� SHEET N0, <br />2 <br />BY: JSW OF 6 SHTS <br />BY: KLK PROJEG:T N0. <br />�,,�y� CITY ENGINEER <br />DWG: A n" ' STOCKTON, CALIF. <br />399/. iC <br />0 <br />E <br />0 <br />