Laserfiche WebLink
10°REMOVE 50'POLE &TRANSFERRECLOSERREMOVE 50'POLE &50/25KVAOPEN DELTABANKREMOVE 50' POLE& TRANSFERCAPACITOR BANKREMOVE30' POLE &2-1/0A QPX SVC(150' PARALLEL)& METER227'293'237'3 50'REMOVE 75'POLE, ANCHORS,15KVA OH TX,RISER, 1/0A TPXCABLE & #2BOX105':CL-H1,SET 12.5' DEEP.15KVA OH TX, 2"RISER,#2SCONDARY BOX, 6-WAYMULTI-TAPS,1-3" PLS (6') &1/0A TPX (88')WEST ANCHOR 20M PISAW/15' LEAD2 X 7/16" DGsSOUTH ANCHOR 15M PISAW/15' LEAD2 X 7/16" DGsS/E ANCHOR 20M PISAW/15' LEAD2 X 7/16" DGs8°990'4°3-4AR12KVREMOVE:55' POLE, ANCHOR,10KVA OH TX, SVC RISER& 1/0A TPX (52').INSTALL:60':CL-H2,SET 9' DEEP IN SAME HOLE(COM & PG&E RISERS).15KVA OH TX, 2" RISER& 1/0A TPX (57') INEXISTING CONDUIT.20M PISA ANCHORW/25' LEAD & 2 X 7/16" DGs.452'3-4AR12KV915'3-4AR12KV270'3-4AR12KV248'3-4AR12KV280'18'2 -4 A R 12K V236'3-4AR12KV248'1 7 0 '45'80859310TLOCATION 6 - UG DETAILREMOVEDOWN GUY & ANCHORINSTALL15M PISA W/6' LEAD& 2 x 3/8" PRIDGsALL PRIMARY INVENTORIEDAT THIS LOCATION:REMOVE3-4AR PRI (2165')2-4AR PRI (236')INSTALL3-715A PRI (2199')2-2AR PRI (350')VIBRATION DAMPERSREQUIRED ON SPANS:LOC 4 - LOC 5LOC 4 - LOC 6LOC 6 - LOC 7INTERNATIONAL PKWYPATTERSONPASSRDHIGHW AY5803-4AR12KV300'42°SW-95807SB-81277REC-99602-MFC-3024900SJOINTPOLE DATA: PG-23-5016-XVREMOVAL LOC #755' POLE SET1991PT-13402-2PG: PTD PT: TXFR*SAME HOLE SET REQUIRED FORBOTHUTILITIES.#2 SECONDARY ENCLOSURE (17" X 30" X 18")OH RECLOSEROH SOLID BLADE DISCONNECT, PT-63OH US SWITCH, 900ACAPACITOR BANK, SIZE ASSHOWNOH TX, SINGLE PHASE, SIZE ASNOTEDPOLE, SIZE & SET DEPTH AS NOTEDPG ONLY ANCHOR, SIZE AS NOTEDRISER, SIZE ASNOTED2-2AR OH PRIMARY (DISTANCES NOTED)3-2AR OH PRIMARY (DISTANCES NOTED)3-715A OH PRIMARY (DISTANCES NOTED)1/0A TPX SEC IN NEW 1-3" PLS (DISTANCE NOTED)1/0A TPX SVC IN EX. 1-3" PLS (DISTANCE NOTED)INSTALLATION LEGENDSYMBOL DESCRIPTIONINSTALL LOC#7PG SET JP #160':CL-H2 JOINTPOLEPG 51-20 PT 25-7PROJECT DESCRIPTIONFULL PG&E INSTALLATION/CONSTRUCTION PROJECT TO RELOCATEPOLE LINE OUT OF WAY OF NEW PROPOSED ROAD WIDENING.POLES AT LOC 1-4 & 6 ARE TO BE SOLELY OWNED WITH COMCASTAS PG&E TENANT. COMCAST IS ALSO A TENANT OF AT&T ATLOCATION 7. COMCAST TO TRANSFER THEIR OWN FACILITIESFROM LOCATIONS 1, 6, 7, 8, 9, 10 & 12 TO NEW POLES ANDINSTALL GUYING.LOCATION 5 NOTE:SHORT LEAD USED TOKEEPANCHORFROM ENCROACHINGON EXISTINGPETROLEUM PIPELINE/RIGHTOFWAYWHILE ADJUSTING ANCHOR ANGLETOBACK UP NEW LINEDIRECTION.LOCATION 4 & 6 NOTE:105' TALL POLES REQUIREDTOOBTAINMINIMUM CLEARANCE ATOVERPASSBASEDON APPLICANT DRAWINGS/ELEVATIONSAND50' SAGFOR SPAN CROSSINGHIGHWAY580.REMOVE1/0A TPX (63')ABANDON1-3" PLS (16')CAUTION:EXISTING COMAND FIBER OPTICCABLES IN AREA12'CALTRA N SRIG H TO FW A YDWRRIGHTOFWAYINSTALL1/0A TPX (96')1-3" PLS(14'NEW)REMOVE:40' POLE & ANCHORINSTALL:50':CL-1, SET 8' DEEP.ANGLE (N/W)ANCHOR15M PISAW/15' LEAD2 X 5/16" DGs715 DE (S/W)ANCHOR20M PISAW/15' LEAD2 X 7/16" DGs55':CL-H1SET 8.5' DEEP.TRANSFER900KVARCAPACITOR.RE-USE EXISTINGEQUIPMENTNUMBERS.55':CL-1SET 8.5' DEEP.TRANSFERRECLOSER.15M PISAW/10' LEAD1 X 7/16"DG.RE-USE EXISTINGEQUIPMENTNUMBERS.REMOVE:55' POLE, ANCHOR,15KVA OH TX, 2" SVCRISER & 1/0A TPX (63')INSTALL:105':CL-H4, SET 12.5'DEEP. 15KVA OH TX,2"RISER, 1-3" PLS (15'),1/0A TPX (97') &6-WAYMULTI-TAPS.N/E ANCHOR 20M PISAW/25' LEAD2 X 7/16" DGs.***INSTALLBARRIERPOSTS TO PROTECTANCHOR AS THISLOCATION ISEXPOSED.N/W ANCHOR 15M PISAW/15' LEAD2 X 7/16" DGs.90'14'85'74'22'60'54'9'67'6'10'47'6'41'96'10'58'94'EDGE OF RIGHT OF WAYEXISTING/PROPOSED FACE OF CURBCENTER OF PROPOSED/EXISTING ROADWAY**DIMENSIONS IN COLORS TO MATCHDIMENSIONING LEGENDLINETYPE DESCRIPTION