Laserfiche WebLink
CO <br />N <br />Z <br />if <br />w <br />EASEMENT "B" <br />C? <br />Q <br />N 715 <br />5' Sanitary Sewer <br />Easement <br />/6 <br />'8 I <br />2/ <br />SHEETEX- <br />! 33 <br />loo watt stree <br />32 <br />3/ <br />30 <br />29 <br />28 <br />27 <br />O RQ div-� 61, SS <br />ORIV <br />SAINT JOACHIM CHURCH <br />` EASEMENT °A" <br />I� 26 IQ' Water Line Easement O - <br />w - <br />KE Y MA P <br />I <br />Z <br />LU <br />2 <br />W <br />N <br />a <br />LU <br />10 <br />2 <br />Line Easement <br />UTILITY SERVICES TO BE PROVIDED BY: <br />1. Water Lockeford Community <br />Z Sanitary Services District Lo ke&,u <br />3. Stone Drain- Lockeford 144,nitn4nce Dist. <br />4. Telephone Pacific Telephone co. <br />5. Electric Pacific Gas A Electric Co. <br />6. Natural Gas Pacific Gas A Electric Co. <br />7. Street Lights Lockeford Lighting District <br />Zone R -1B <br />Easements shall be provided as required by the various <br />utilities. <br />G <br />I NA <br />STREET SYSTEM <br />LEGEND <br />1. <br />'I c -k shah lr,fdrm to these play and any special pro,i_ions <br />_CT. <br />_ <br />3 <br />CD <br />e%157 STREET Lu <br />fc tls prole,' <br />N"fe to the tial map c this subd:r-Sion for all renter line <br />'4Y <br />50,600 <br />- _ <br />-- <br />N <br />Aggregate Base, Cl. II (11") <br />1,850 <br />S.F. <br />'. <br />LP _ LOW POINT <br />10 <br />17,700 <br />S.F. <br />IIP - HIGH POINT <br />Aggregate Base, Cl. II (0.50') <br />31,050 <br />S.F. <br />4. <br />TC --- TOP OF CURB <br />Asphalt Concrete Type B (0.25 ) <br />19,550 <br />S.F. <br />PRC _ POINT OF REVERSE CURVE <br />Asphalt Concrete Type B (0.20' ) <br />31,050 <br />w <br />z"50 STORM DRAIN LINE INDICATING DIRECTION OF FLOW <br />Vertical Curb, Gutter & <br />Sidewalk <br />N <br />65- SANITARY SEWER LINE INDICATING DIRECTION OF FLOW <br />Beveled Curb, Gutter & <br />81 <br />L.F. <br />---WATER LINE AND VALVE <br />Sidewalk <br />¢- FH _-__ FIRE HYDRANT 1500r <br />Concrete Subgrade Compaction <br />3,029 <br />21,900 <br />L.F. <br />S.F. <br />5. <br />STREET LIGHT (100 WATT HIGH PRESSURE -SODIUM VAPOR <br />�f <br />Survey Monument, Type S <br />9 <br />12 <br />I <br />3 <br />Each <br />r <br />B.C. _ BEGIN CURVE <br />Street Sign Post Street Name <br />2 <br />Z <br />Each <br />EB&I <br />E.C. END CURVE <br />Stop Sign (R-1) <br />9 <br />I <br />I_LL 6 <br />Street Light <br />2 <br />Each <br />ECR END CURB RETURN <br />Painted Stop Bar <br />7 <br />Each -Ely PG FE. <br />Services District, U.S.A. (BOO! 642-2444. <br />G.B. __ GRADE BREAK <br />3 <br />20,000 <br />N <br />6. <br />House services, fire hydrant laterals, and street light conduit <br />W <br />I <br />100 watt street Li ht <br />-RVQ <br />p <br />Turnaround <br />I� <br />I <br />� <br />N. <br />Remove Ex. Barricade <br />2,000 <br />/0 I0� <br />Iol <br />5 <br />a. P.U.E. PUBLIC UTILITY EASEMENT <br />\ <br />Each <br />7, <br />All manholes to be set flush with the finish grade unless <br />6aS, <br />1.5. E,- LANDSCAPE SETBACK EASEMENT <br />It"s <br />otherwise indicated. <br />3 <br />Lump Sum <br />/g S <br />R/W _ RIGHT OF WAY <br />- Cc <br />2,100 <br />C.Y. <br />- CENTERLINE <br />Water used in any phase of construction, such as backfill <br />Lot Grading -Import Fill <br />OE _ FLOWLINE <br />w <br />1n V. INVERT <br />(Compacted) <br />ye.soss <br />a <br />24"SO <br />shall be included in the unit price or lamp sum bid for the <br />I <br />ho 1 <br />3 4 <br />°' P <br />I <br />I <br />411 A.C. ASPHALT CONCRETE <br />2/ <br />SHEETEX- <br />! 33 <br />loo watt stree <br />32 <br />3/ <br />30 <br />29 <br />28 <br />27 <br />O RQ div-� 61, SS <br />ORIV <br />SAINT JOACHIM CHURCH <br />` EASEMENT °A" <br />I� 26 IQ' Water Line Easement O - <br />w - <br />KE Y MA P <br />I <br />Z <br />LU <br />2 <br />W <br />N <br />a <br />LU <br />10 <br />2 <br />Line Easement <br />UTILITY SERVICES TO BE PROVIDED BY: <br />1. Water Lockeford Community <br />Z Sanitary Services District Lo ke&,u <br />3. Stone Drain- Lockeford 144,nitn4nce Dist. <br />4. Telephone Pacific Telephone co. <br />5. Electric Pacific Gas A Electric Co. <br />6. Natural Gas Pacific Gas A Electric Co. <br />7. Street Lights Lockeford Lighting District <br />Zone R -1B <br />Easements shall be provided as required by the various <br />utilities. <br />C� KEY SHEET STRUCTURAL SECTION <br />✓-0 PLAN PROFILE SCALE= Noriz7 /"=5'; Vcrt--/r'=5' <br />L O DE TAI LS 50' <br />-- --- __25._ _ 0- 25' <br />2 5' 18 i8' <br />U GRADING PLAN - <br />10 � - <br />- <br />' I` - <br />rJ OOlJSTRUCTlON QUANTITIES_ Y4pft. l.5%lineC°°t 1.5 <br />SITE <br />BRANDt RD. <br />6JAtE o� , <br />Hwy. /Z <br />�e <br />H <br />V/CItN/lr NI/IA <br />NI fGviLE <br />N0. I DATE REVISIONS <br />Q 1 //2,9A/ s -8u/// <br />rV4peperft. <br />j u Beveled Type CG 45 I ' 0,2O'A,C,-Type "B"-V2°Max. Agg. - <br />92% R.C. concrete 0.50'A.B.- CI 11 3/4" Max Agg. <br />subgrade Compactlon 0.67' 95% R C.Origincll Ground <br />MILFORD DRIVE...- ABILENE DRIVE <br />Design RValue =l9(MILFORO) 25(ABILENE) T.I.= 4.0 G.E. Provided= 1.05 G.E.Requlred= 1.04(MILFOP-D) <br />C.96 (ABILENE) <br />60' <br />---- <br />------ --- ---- <br />------ <br />30' 30-- --_-- erre- <br />3 5 ` <br />- --- ---- <br />- -+-_ 22 ____2 <br />22' <br />i 2 <br />%4"perft <br />Prime Coat <br />°i - <br />. _. _ I.5 <br />117IT1111 TTT7ZTTT�ITIZ 77�_ZZ <br />0.25'A. -T u a <br />Beveled Type C.G q S C, ype B" -j <br />/2 Max. Agg. <br />-92% R.G. Concrete 0.67' A.B.- CI.11 3/4" Max. Agg. <br />Subgrade Compaction 0.67' 95 9'o R.C. Original Ground <br />Design R -Value = 19 T. 1, = 5.0 G. E. Prov(ded= 1.36 G.E. Required 1.30 <br />L 0 CK E_FORD RANCH DRIVE <br />5TAT/0/V /0`54, 43 to <br />BY DESIGN DRAWN BY APPROVED <br />��P - A�..� - /2 <br />SUBMM'ED BY <br />R.C.E. 4Z7 4 DATE SAN JOAQUIN COUNTY DIRECTOR.OF PUBLIC WORKS <br />A PPR O V r) _9'f" <br />M7�LU•/ I�DISTRI_ <br />LOCKEPORD COMMUNITYsERVIC ' <br />"Ahl"JOAQUIN COUNTY 6 R MARSHAL DATE <br />r SAN JOAQUIN LOCAL HEALTH "SERVICES DATE <br />_ 30' - <br />3' 3' 5' 222' <br />I I' 2' S' <br />-- <br />Beveled Type CCA cS <br />92% R.G. Concrete <br />5ubgrade Compaction <br />LOC <br />BAUMBACH & PIAZZA <br />CIVIL ENGINEERS <br />SURVEYORS <br />323 W. ELM ST. 1_0011, CALIF. <br />96240 PH: 209-388-8618 <br />CONSTRUCTION QUANTITIES <br />GENERAL NOTES <br />STREET SYSTEM <br />LEGEND <br />1. <br />'I c -k shah lr,fdrm to these play and any special pro,i_ions <br />Item <br />-9) _ MONUMENT FRAME & COYER <br />2. <br />fc tls prole,' <br />N"fe to the tial map c this subd:r-Sion for all renter line <br />k -- STREET SIGN <br />50,600 <br />S.F. <br />_ SIDE INLET CATCH BASIN <br />Aggregate Base, Cl. II (11") <br />1,850 <br />S.F. <br />'. <br />LP _ LOW POINT <br />Aggregate Base, Cl. II (0.67') <br />17,700 <br />S.F. <br />IIP - HIGH POINT <br />Aggregate Base, Cl. II (0.50') <br />31,050 <br />S.F. <br />4. <br />TC --- TOP OF CURB <br />Asphalt Concrete Type B (0.25 ) <br />19,550 <br />S.F. <br />PRC _ POINT OF REVERSE CURVE <br />Asphalt Concrete Type B (0.20' ) <br />31,050 <br />S.F. <br />z"50 STORM DRAIN LINE INDICATING DIRECTION OF FLOW <br />Vertical Curb, Gutter & <br />Sidewalk <br />65- SANITARY SEWER LINE INDICATING DIRECTION OF FLOW <br />Beveled Curb, Gutter & <br />81 <br />L.F. <br />---WATER LINE AND VALVE <br />Sidewalk <br />¢- FH _-__ FIRE HYDRANT 1500r <br />Concrete Subgrade Compaction <br />3,029 <br />21,900 <br />L.F. <br />S.F. <br />5. <br />STREET LIGHT (100 WATT HIGH PRESSURE -SODIUM VAPOR <br />�f <br />Survey Monument, Type S <br />9 <br />120 VOLT SCH. L.S. 1-E_AS SWOWN ON PLAN <br />Dead End Barricade, Type A <br />Each <br />B.C. _ BEGIN CURVE <br />Street Sign Post Street Name <br />2 <br />Z <br />Each <br />EB&I <br />E.C. END CURVE <br />Stop Sign (R-1) <br />BCR BEGIN CURB RETURN <br />Street Light <br />2 <br />Each <br />ECR END CURB RETURN <br />Painted Stop Bar <br />7 <br />Each -Ely PG FE. <br />Services District, U.S.A. (BOO! 642-2444. <br />G.B. __ GRADE BREAK <br />3 <br />20,000 <br />Each <br />S.F. <br />6. <br />House services, fire hydrant laterals, and street light conduit <br />4" Aggregate Base, Temporary <br />Q B.O. BLOWOFF <br />p <br />Turnaround <br />0 L.F. -- LINEAL FEET <br />underground utilities within the street area, including gas and <br />Remove Ex. Barricade <br />2,000 <br />S.F. <br />un <br />a. P.U.E. PUBLIC UTILITY EASEMENT <br />1 <br />Each <br />7, <br />All manholes to be set flush with the finish grade unless <br />34 <br />1.5. E,- LANDSCAPE SETBACK EASEMENT <br />J <br />otherwise indicated. <br />3 <br />Lump Sum <br />B. <br />R/W _ RIGHT OF WAY <br />- Cc <br />2,100 <br />C.Y. <br />- CENTERLINE <br />Water used in any phase of construction, such as backfill <br />Lot Grading -Import Fill <br />OE _ FLOWLINE <br />w <br />1n V. INVERT <br />(Compacted) <br />8,700 <br />ExiExist EXISTING <br />24"SO <br />shall be included in the unit price or lamp sum bid for the <br />R PROPERTY LINE <br />1,076 <br />3 <br />I <br />I <br />411 A.C. ASPHALT CONCRETE <br />Y uP <br />St t <br />Each <br />10. <br />Contractor shall give Engineer a minimum of 48 hours notification <br />A.B. AGGREGATE BASE <br />z <br />F1 <br />on a'. JP L4 <br />Each <br />O A S.B. AGGREGATE SUBBASE <br />prior to staking an; utilities, <br />STORM DRAIN SYSTEM <br />C.O.G. COMPACT ORIGINAL GROUND <br />11. <br />Lot grading shall be completed before starting any underground <br />R.C. - RELATIVE COMPACTION <br />construction. Refer to attached grading plan. <br />12" Storm Drain <br />458 <br />C.S.P. __ CORRUGATED STEEL PIPE <br />12. <br />Contractor shall be responsible for notifying and co -coordinate <br />15" Storm Drain <br />E3. 0. BLOWOFF <br />Y <br />L.F. <br />all work with any agency requiring removal or relocation of <br />18" Storm Drain <br />U S.D.MLH. STORM DRAIN MANHOLE <br />L.F. <br />utilities, such as Pacific Bell, P. "o. 6 E., etc. <br />48" Storm Drain Manhole <br />Q S.S.M.H SANITARY SEWER MANHOLE <br />Each <br />13. <br />All Water lines shall be pressure tested, disinfected, flushed <br />Side Inlet Catch Basin <br />T.1. TRAFFIC INDEX <br />Each <br />and tested for bacteria in conformance with the San Joaquin <br />Remove Ex. 12" Storm Drain <br />Square Drop Inlet Catch Basin <br />R• _ RADIUS <br />L.F. <br />County Health Code Requirements prior to connecting to existing <br />0 DELTA <br />1 <br />Each <br />L. LENGTH <br />SANITARY SEWER SYSTEM <br />S.S.C.Q_ SANITARY SEWER CLEANOUT <br />Contractor shall visit site prior to bidding. Specifications are <br />RV -I R -VALUE SAMPLE TESTED BY ROPER&ASSOC. 2/12/91 <br />a separate document. <br />6" Sanitary Sewer <br />R1/ -A 4 RV -3 R -VALUE SAMPLES <br />L.F. <br />15. <br />New traffic striping and the restoration of any damaged existing <br />CONSTRUCTION -STAKING -LIABILITY -WAIVER <br />8 <br />Each <br />These improvement plans have been prepared with the <br />L.amphoIe <br />�anitar-y Service <br />2 <br />Each <br />intent that the firm of Baumbach & Piazza, Inc. will be <br />be included inhisbidprice. Also applies tosignscreflectmemarkers <br />performing the construction staking for the complete <br />Each <br />16. <br />project. If, however, another engineering and/or <br />surveying firm should be employed to use these plans for <br />pipe, centered over the SO or SS if: a) The water is under the SO <br />WAl FR SYSTE=M <br />the purpose of construction staking, notice is hereby <br />or SS, b) The vertical clearance is less than I foot. Applies <br />given that the firm of Baumbach & Piazza, Inc. will not <br />to catch basins also <br />assume any responsibility for errors or omissions, if <br />5 5 7 <br />2,854 <br />L . F . <br />L.F. <br />17. <br />any, which might occur and which could have been avoided, <br />6" Valve <br />2 <br />Each <br />corrected or mitigated if Baumbach & Piazza, Inc. had <br />public Works. Tte; shah to .i,ntitied rct le=ss ttan _A roars in <br />8 " Valve <br />10 <br />performed the staking work. <br />.:d:. re at coo„ru ;ealent c' - <br />Fire Hydrant Assembly <br />Benchmark Datum: Brass Cap, stamped MN -10.30 (SE)Corner <br />Each <br />1£. <br />it , agreed 'fat field conditions may require Changes to these <br />of Jack Tone Road 4 Highway 88 in concrete curb below 11 Payless" <br />2 <br />Each <br />sign. Elevation 96.71 U.S.G.S, 1929 Datum. <br />C� KEY SHEET STRUCTURAL SECTION <br />✓-0 PLAN PROFILE SCALE= Noriz7 /"=5'; Vcrt--/r'=5' <br />L O DE TAI LS 50' <br />-- --- __25._ _ 0- 25' <br />2 5' 18 i8' <br />U GRADING PLAN - <br />10 � - <br />- <br />' I` - <br />rJ OOlJSTRUCTlON QUANTITIES_ Y4pft. l.5%lineC°°t 1.5 <br />SITE <br />BRANDt RD. <br />6JAtE o� , <br />Hwy. /Z <br />�e <br />H <br />V/CItN/lr NI/IA <br />NI fGviLE <br />N0. I DATE REVISIONS <br />Q 1 //2,9A/ s -8u/// <br />rV4peperft. <br />j u Beveled Type CG 45 I ' 0,2O'A,C,-Type "B"-V2°Max. Agg. - <br />92% R.C. concrete 0.50'A.B.- CI 11 3/4" Max Agg. <br />subgrade Compactlon 0.67' 95% R C.Origincll Ground <br />MILFORD DRIVE...- ABILENE DRIVE <br />Design RValue =l9(MILFORO) 25(ABILENE) T.I.= 4.0 G.E. Provided= 1.05 G.E.Requlred= 1.04(MILFOP-D) <br />C.96 (ABILENE) <br />60' <br />---- <br />------ --- ---- <br />------ <br />30' 30-- --_-- erre- <br />3 5 ` <br />- --- ---- <br />- -+-_ 22 ____2 <br />22' <br />i 2 <br />%4"perft <br />Prime Coat <br />°i - <br />. _. _ I.5 <br />117IT1111 TTT7ZTTT�ITIZ 77�_ZZ <br />0.25'A. -T u a <br />Beveled Type C.G q S C, ype B" -j <br />/2 Max. Agg. <br />-92% R.G. Concrete 0.67' A.B.- CI.11 3/4" Max. Agg. <br />Subgrade Compaction 0.67' 95 9'o R.C. Original Ground <br />Design R -Value = 19 T. 1, = 5.0 G. E. Prov(ded= 1.36 G.E. Required 1.30 <br />L 0 CK E_FORD RANCH DRIVE <br />5TAT/0/V /0`54, 43 to <br />BY DESIGN DRAWN BY APPROVED <br />��P - A�..� - /2 <br />SUBMM'ED BY <br />R.C.E. 4Z7 4 DATE SAN JOAQUIN COUNTY DIRECTOR.OF PUBLIC WORKS <br />A PPR O V r) _9'f" <br />M7�LU•/ I�DISTRI_ <br />LOCKEPORD COMMUNITYsERVIC ' <br />"Ahl"JOAQUIN COUNTY 6 R MARSHAL DATE <br />r SAN JOAQUIN LOCAL HEALTH "SERVICES DATE <br />_ 30' - <br />3' 3' 5' 222' <br />I I' 2' S' <br />-- <br />Beveled Type CCA cS <br />92% R.G. Concrete <br />5ubgrade Compaction <br />LOC <br />BAUMBACH & PIAZZA <br />CIVIL ENGINEERS <br />SURVEYORS <br />323 W. ELM ST. 1_0011, CALIF. <br />96240 PH: 209-388-8618 <br />CONSTRUCTION QUANTITIES <br />GENERAL NOTES <br />STREET SYSTEM <br />1. <br />'I c -k shah lr,fdrm to these play and any special pro,i_ions <br />Item <br />Quantity <br />2. <br />fc tls prole,' <br />N"fe to the tial map c this subd:r-Sion for all renter line <br />Compact Original Ground <br />50,600 <br />S.F. <br />a!:d property line data. <br />Aggregate Base, Cl. II (11") <br />1,850 <br />S.F. <br />'. <br />Contractor shall receive an approved set of plans and <br />Aggregate Base, Cl. II (0.67') <br />17,700 <br />S.F. <br />specifications prior to beginning construction. <br />Aggregate Base, Cl. II (0.50') <br />31,050 <br />S.F. <br />4. <br />Baumbach 5 ha.za (Engineer) shall set all survey controls and <br />Asphalt Concrete Type B (0.25 ) <br />19,550 <br />S.F. <br />construction stakes necessary for completion of work. The <br />Asphalt Concrete Type B (0.20' ) <br />31,050 <br />S.F. <br />Contractor shall bE responsible for the preservation of al. <br />Vertical Curb, Gutter & <br />Sidewalk <br />survey and Construction stakes, Surrvey and construction, stakes. <br />Beveled Curb, Gutter & <br />81 <br />L.F. <br />that are lost or destroyed due to Contractor's negligence will be <br />Sidewalk <br />set by the Engineer at the Contractor's e..pense. <br />Concrete Subgrade Compaction <br />3,029 <br />21,900 <br />L.F. <br />S.F. <br />5. <br />The exi=_.tiny underground utilities were plotted from availatle <br />Survey Monument, Type S <br />9 <br />records. The Contractor shall be responsible for contacting ail <br />Dead End Barricade, Type A <br />Each <br />utility agenCiEs to mark their facilities in the field before any <br />Street Sign Post Street Name <br />2 <br />Z <br />Each <br />EB&I <br />excavation. The Contractor shall notify and coordinate all work <br />Stop Sign (R-1) <br />with arty agency requiring removal or relocation of their <br />Street Light <br />2 <br />Each <br />utilities. Pacific Bell, P. G. t E., and Lockeford Community <br />Painted Stop Bar <br />7 <br />Each -Ely PG FE. <br />Services District, U.S.A. (BOO! 642-2444. <br />Asphalt Concrete Overlay <br />3 <br />20,000 <br />Each <br />S.F. <br />6. <br />House services, fire hydrant laterals, and street light conduit <br />4" Aggregate Base, Temporary <br />shall be installed prior to curb and gutter construction. All <br />Turnaround <br />underground utilities within the street area, including gas and <br />Remove Ex. Barricade <br />2,000 <br />S.F. <br />telephone lines, shall be installed prior to paving. <br />10 Gallon Trees <br />1 <br />Each <br />7, <br />All manholes to be set flush with the finish grade unless <br />34 <br />Each <br />otherwise indicated. <br />Site Clearing & Grubbing <br />Lump Sum <br />B. <br />All water lines shall have a minimum cover of 30". <br />Roadway Excavation <br />2,100 <br />C.Y. <br />9. <br />Water used in any phase of construction, such as backfill <br />Lot Grading -Import Fill <br />compaction, dust control, testing or other wori: herein required, <br />(Compacted) <br />8,700 <br />C.Y. <br />shall be included in the unit price or lamp sum bid for the <br />Wood Retaining Wall <br />1,076 <br />L.F. <br />respective item of construction. <br />Sign SW42Si <br />9 <br />1 <br />Each <br />10. <br />Contractor shall give Engineer a minimum of 48 hours notification <br />W 53 5ign <br />1 <br />Each <br />prior to staking an; utilities, <br />STORM DRAIN SYSTEM <br />11. <br />Lot grading shall be completed before starting any underground <br />construction. Refer to attached grading plan. <br />12" Storm Drain <br />458 <br />L.F. <br />12. <br />Contractor shall be responsible for notifying and co -coordinate <br />15" Storm Drain <br />374 <br />L.F. <br />all work with any agency requiring removal or relocation of <br />18" Storm Drain <br />321 <br />L.F. <br />utilities, such as Pacific Bell, P. "o. 6 E., etc. <br />48" Storm Drain Manhole <br />5 <br />Each <br />13. <br />All Water lines shall be pressure tested, disinfected, flushed <br />Side Inlet Catch Basin <br />9 <br />Each <br />and tested for bacteria in conformance with the San Joaquin <br />Remove Ex. 12" Storm Drain <br />Square Drop Inlet Catch Basin <br />23 <br />L.F. <br />County Health Code Requirements prior to connecting to existing <br />1 <br />Each <br />waterline. <br />SANITARY SEWER SYSTEM <br />14. <br />Contractor shall visit site prior to bidding. Specifications are <br />a separate document. <br />6" Sanitary Sewer <br />2,335 <br />L.F. <br />15. <br />New traffic striping and the restoration of any damaged existing <br />Sanitary Sewer Manhole <br />8 <br />Each <br />painted legends or signs is the responsibility of the Contractor andsholl <br />L.amphoIe <br />�anitar-y Service <br />2 <br />Each <br />be included inhisbidprice. Also applies tosignscreflectmemarkers <br />34 <br />Each <br />16. <br />Where water crosses SO or SS use an 20 ft. length of Cl. 200 <br />pipe, centered over the SO or SS if: a) The water is under the SO <br />WAl FR SYSTE=M <br />or SS, b) The vertical clearance is less than I foot. Applies <br />to catch basins also <br />6 Water <br />8' Water <br />5 5 7 <br />2,854 <br />L . F . <br />L.F. <br />17. <br />kll work will be rcqu:red to Le inspe +o -a ty the Departaent of <br />6" Valve <br />2 <br />Each <br />public Works. Tte; shah to .i,ntitied rct le=ss ttan _A roars in <br />8 " Valve <br />10 <br />Each <br />.:d:. re at coo„ru ;ealent c' - <br />Fire Hydrant Assembly <br />3 <br />Each <br />1£. <br />it , agreed 'fat field conditions may require Changes to these <br />B l owo f f <br />2 <br />Each <br />plans. It is further agreea that the Director of Public Works <br />1" Water Service <br />34 <br />Each <br />may require Changes, alter tions or additions to these plans, <br />when, the Director deems that, to be necessary or desirable for the <br />Proper coapletion of the wort:, provided that such changes, <br />alterations or additions shall not Exceed 10% of the original <br />Under separate contract with Lockeford <br />estimate of the cost for the improvement= without prior aporosal <br />Community Services District: <br />of the surety. <br />19. <br />Fire hydrant bid shall include the following: Tee, 6" Lateral, <br />Install 1" Water Services along <br />6" Valve and complete fire hydrant assembly. <br />Jack Tone Road <br />9 <br />Each <br />20. <br />Pipet a and strer th it d f <br />"0 <br />�� <br />me Coa <br />1.'5% <br />0.25' A.G.--Type ns"^V2" Max.Agg <br />\- <br />O 6.7 A.B.- C 111 3/4" Max, Agg. 0.67' 95% R.G. Origlnaf Around <br />EFORD RANCH DRIVE <br />AT/ON /,9y-78.6/ to 20,,00.00 <br />KEY MAP <br />A. Thr q shall '_ave conpections tests taken for street subgrade, utility <br />tri ,L,� and lot fill. Any required retests will be at the contractor's <br />e.lev e. Sanitary sewer trench compaction tests shall be done by a <br />q.,alified soils testing laboratory as required by the county. <br />Cont(alior shall call for the tests and submit the results to the <br />engineer and County as soon as possible. <br />39. Import material sampling and testing shall be the responsiblitp A the <br />contractor. All re5ults.shall be sent to the Engineer and the County <br />Inspector. Approval required from J.H. Kleinfelder I, Associates. <br />40. All utilities shall be underground. Existing telephone poles to be <br />removed by Pacific Bell. Joint poles to be removed by P. G. 1 E. <br />41. Sanitary Sewers shall have laying grade established by laser control. <br />Video inspection will be required (see specifications). Deflection <br />test and air test will be required after lines are balled and flushed <br />according to the specifications. <br />42. Contractor shall install g striping with yellow raised reflective markers <br />on Lockeford Ranch Drive per Cal Trans Traffic Mclnual• Re%r to Detoi/ <br />0,- 5fofe 51'0' /Ploys A20 -H. <br />43. Thrust blocks to be constructed as required by detail. <br />30' <br />22" 5' 3 <br />1.5% <br />� °/ <br />, <br />L <br />yp g s a owe or underground utilities, unless <br />otherwise specified on plans, are as follows: Store Drain (SO) <br />RCP I C1. 1I1, Sanitary Sewer (SS) - UCP., Extra Strength <br />per ASTM Std, C-700; Water (W) - PVC, C1. 150 or greater per AWWA <br />Std. C-900. (PVC, SDR 35 nay be used for SS, with special <br />approval of the District). <br />21. Any changes to the approved Improvement Flans and specifications <br />must he prepared and certified by the "Civil Engineer" and shall <br />be approved by "Director" prior to implementation. - <br />22. The street light system shall be installed by Pacific Gas and <br />Electric Company. <br />N. All existing irrigation lines within the right of way shah be <br />removed. <br />24. Sanitary sewer services shall be marked by the curb and gutter <br />contractor with an "S" stamped on the top of curb. <br />25, Water services shall be marked by the curb and gutter Contractor <br />with a "W" stamped on the top of curb. Location of water <br />markings shall be verified in the field by the Engineer. <br />26. No materials resulting from tapping procedures may enter District <br />sewer. <br />27. Separation of water and sewer mains (including crossings) and <br />sewer laterds crossing over water mains shall meet or exceed the <br />latest standards of the State of California Department of Health <br />Services. <br />28. Each SS service to have C.D. at property line. See detail on <br />sheet 8. <br />29. Note that inspection of all underground utilities will be <br />performed by San Joaquin County Department of Public Works and <br />Lockeford Community Services District. They must be inspected <br />before backfill. Notify Inspectors 48 hours prior to requiring <br />their services. Phone (209) 727-50,;5, and (209) 468-3022. <br />30. All traffic signs and markings shall conform with San Joaquin. <br />County Standards and with the "Manual on Uniform Traffic Control <br />De v i C es" , and shall be installed by the contractor. <br />31. Install a reflective, blue marker near center line of street to <br />denote the fire hydrant location. <br />2. Material sampling and testing shall be the responsibility of the <br />contractor. All results shall be sent to the Engineer anc the <br />County Inspector. <br />ter `'a Lt a,n <br />J.-jui l iry fC "...•h w ' r ,J,E eti3O _+ e•t R/W. <br />'-A. For Water Mair: under a Ear:ita:r Se.yer Lateral Crolsirg, a v =rc- <br />ler'g'h c floss :U, ;C 97p1 lie shat! be ;.stalled dna cEntt cd <br />at the sewer cross:r,g. The ,erti_al separation s_ -hail be fC,,r <br />ro'p`es it mom. <br />.5, All off-site storm drains arm., ue c' -a -.Ed prior to +ir;ai <br />aaeptar e <br />6 Contractor f.i, dt In a yr 1 u permit + r. the ,r '6d;_F <br />count, 4,1 D <br />wino u n. iFee b, Owns:-: <br />N. ,urtractor agrees that he shiill assume s.le n .- cond.ett <br />respon i'rlxty for job citE cocditioas CIrInn the :-J"Se �f <br />construction .f th , pro]eet n lading fet of all Persons and <br />prupert , trat this rzqu rement still apply cortinucusly aria not <br />be limited to ;normal working hoe s and too' the con+ a for stall <br />defend, indemnify and hold harmle-a, the Curt/ of San acagoin, <br />its elected officials, officers., employees, and agents from any <br />and all claims, costs of litigation, damages, and attorney's <br />fees, for personal injury or 'property damage of whatever nature <br />which are claimec to have occurred during the term of this. <br />proiect, <br />'m LOC K E FO RD RANCH mm <br />SUBD1V15MN IMPROVEMENTS <br />SHEET O OF 10 <br />JOB NO. 90109 <br />FILE <br />N0. � - 968 <br />