Laserfiche WebLink
to <br />-o- <br />r <br />R.V. PARK <br />-0-0-0 <br />CONTROL PANEL <br />8" THICK PCC SLAB PEDESTAL MOUN <br />BASE w/TOP 3" ABOVE <br />GRADE. <br />W <br />W <br />n <br />0— NOTES: <br />1. UNDERGROUND ELECTRIC SERVICE <br />PER UTILITY CO. SPECIFICATIONS <br />2. EXTERIOR OF CONTROL <br />PANEL TO BE PAINTED LIGHT <br />BUFF COLOR. (2 COATS MIN.) <br />4" GRAVEL <br />V 0 <br />0 0' <br />�'- 0 --�120 WIDE SINGLE <br />FIRE EMERGENCY ACCESS ROAD <br />4" GRAVEL <br />AlCLavllliTZ <br />NOT TO SCALE <br />ALUMINUM ACCESS DOOR <br />w HANDLE,LOCK,HASP & <br />LOCK OPEN "BILCO" OR E <br />15 0 9" D.C. <br />0TH WAYS. (TYP.) <br />3 1/2--J <br />GUIDE RAIL. <br />° <br />ELL. <br />VALVE <br />ENCLOSURE <br />E <br />WATERTIGHT N <br />COMPRESSION <br />SEAL (TYP. ALL 4" FORCE MAIN <br />LINES) <br />- GALVANIZED <br />S•T�EL CHAIN 4" GATE VALVE <br />19.00 ALARM ELEV. w/RING °. 4" CHECK <br />VALVE. <br />6" SAN. SEWER SEALING '' <br />2" DRAIN UNE w/CHECK VALVE <br />RING <br />18.75 6" INV. <br />(TYP-) <br />18.50 2nd PUMP ON <br />4"0 PVC SCHED. 80 <br />> PIPE w/FLANGES <br />° <br />17.50 FIRST PUMP ON <br />°. 6' DIAMETER WET WELL R.C.P. CL. III <br />'.. w + OR REINFORCED FIBERGLASS ON <br />CIL ' CONCRETE BASE <br />a. <br />.. w <br />Ir °.. <br />:' x <br />VV) SLIDE -AWAY QUICK <br />C3 DISCONNECT COUPLINGS. <br />15.00 BOTH PUMPS OFF ° r <br />HEAVY DUTY, NON -CLOG ° GROUT <br />SUBMERSIBLE SEWAGE PUMP. <br />STATIONARY <br />10" " ELBOW <br />zF 12.50 <br />........... <br />#4 O 12" BOTH <br />STAINLESS STEEL <br />ANCHOR BOLTS. <br />PUMP STATION SECTION <br />NOT TO SCALE <br />NO. DESCRIPTION COUNTY APPROVAL <br />APPROVED BY.• DATE PLOT DATE: 04/26/95 SCALE <br />HORIZONTAL: AS SHOWN <br />U) <br />O PLOT TIME: 17:59 <br />W FILE: 93002\MAINSSPS SURVEY <br />PLANS: F.B.: <br />CHECKED: ❑ Roger D. Rumph PROFILE: F.B.: <br />3 <br />6' HIGH CHAIN LINK FENCE <br />THE INSIDE AND OUTSIDE OF WET WELL (IF <br />CONCRETE PIPE) AND ALL VALVES AND <br />FITTINGS SHALL BE HEAVILY COATED WITH <br />COAL TAR EPDXY. <br />T.B.M. DES <br />BRASS CAP 1640' WEST OF SOUTH 99 <br />FRONTAGE ROAD, SOUTH SIDE OF FRENCH <br />CAMP ROAD, MARKED QR -30.7, U.S.G.S. <br />DATUM <br />ELECTRICAL NOTES: <br />1. All materials, equiptment, and installation work shall conform with the <br />California Administration Code, Title 24, State Building Standards, Part 3, <br />Basic Electrical Regulations, the National Electric Code, the NEMA <br />specifications, and the Division of Industrial Safety requirements. <br />2. Contractor shall furnish all equipment, materials and labor necessary to provide <br />a complete and operating electrical installation whether shown on this drawing <br />or not. Motor control equipment shall be of one manufacturer except as <br />indicated to insure compatability. <br />3. All conductors to be type THW insulation. <br />4. No conduit smaller than 3/4" shall be used. <br />5. SERVICE ENTRANCE—service entrance conduit and conductors shall be installed <br />in accordance with P.G. & E. instructions for commercial and industrial <br />installations and in conformance with local requirements. Verify location of <br />service with local P.G. & E. representatives. <br />6. Contractor to provide as—built drawings. <br />7. All wires shall be numbered and tied where possible. <br />SAN. SEWER LIFT PUMP STATION IS A PART OF THE <br />R.V. PARK AND SHALL BE PERMANENTLY OWNED, <br />OPERATED & MAINTAINED BY OWNER OF R.V. PARK. <br />CONTROL DIAGRAM <br />ELEVATION: <br />28.118' <br />LEGEND <br />HOA HAND-OFF AUTOMATIC SWITCH <br />FE-Tm-1 ELAPSED TIME METER <br />atz CONTROL RELAY <br />TD TIME DELAY <br />0c RUNNING INDICATOR UGHT (GREEN) <br />MP MERCURY PROBE <br />IA) ALARM UGHT-100 WATT INCANDESCENT <br />nn��cc (FLASHING) WITH RED GLOBE. <br />CROUSE HINDS VRB-120 <br />® SEAL FAILURE LIGHT (RED) <br />®SEWER TREATMENT PLANT CONTROL RELAY - <br />HIGH WATER IN BUFFER TANK <br />ISR INTRINSICALLY SAFE RELAY <br />450 VOLT <br />,3PH <br />Ilelam:0Inspl]I:TenzAaml <br />SHEET <br />I I <br />OF <br />L irmo ► —M 0 ► O NIM. I"G h, <br />Contractor shall furnish and install as shown on these drawings and as described <br />in these specifications one duplex submersible type sanitary sewer pumping station <br />complete, including, pumps, motors, electrical controls, quick disconnect system, wet <br />well and discharge piping. <br />PUMP AND MOTOR CONSTRUCTION: <br />Pumps shall be of the heavy duty non—clog type capable of pumping unscreened <br />sewage consisting of water, heavy sludge and spherical solids up to 3 inches in <br />diameter. <br />Each pump shall have a capacity of 175 GPM ® 35' TDH with 50% minimum <br />efficiency and 120 GPM ® 39' TDH. <br />Motors shall be 5 H.P., 3 phases 60 HZ, 480 volts. Both pumps and motors shall <br />have the capability of running dry for extended periods without damage to motor seals. <br />Pump volute, motor enclosure and seal housing shall be ASTM A-48 Class 30 cast <br />iron or better. All fasteners exposed to the pumped liquid and the motor shaft <br />on which the impeller is mounted shall be stainless steel. Impeller shall be single <br />or mulitple port enclosed type. Impeller diameter shall be trimmed to meet <br />specified system flow and head conditions. The inner seal shall operate in a sealed, <br />oil—filled chamber containing moisture sensing probes capable of detecting any <br />influx of conductive liquid past the outer seal. Pumps shall be "PACO", FLYGT" <br />or -approved equal. Replacement parts must be locally available (within a 200 <br />mile radius). <br />ELECTRICAL CONTROLS: <br />All electrical controls for the pump station shall be mounted in a NEMA 3R <br />double—door, dead—front enclosure with a padlock hasp. The controls for each <br />pump shall include a thermal circuit breaker, a rotary hand—off automatic switch, <br />a thermal magnetic motor starter with ambient compensated overload relays <br />and quick trip heaters, running lights and elapsed time meter. <br />Pump operation shall be controlled by four bulb—type liquid level sensors (Flygt <br />Model ENP -10 or equivalent): one for lead pump turn—on, one for lag pump turn—on, <br />one for both pumps turn—off, and one for high water alarm. The pumps shall operate <br />singly or in parallel. An automatic alternator shall alternate the lead—standby duty on <br />each succeeding pump cycle. A 0-10 minute adjustable delay timer shall be included in <br />the lead pump activation circuit. The pumps shall be set <br />to tum off 2.5 feet above the bottom of the wet well. The on—site alarm shall <br />include a flashing red light and horn. The alarm circuit shall include 2 spare contacts <br />for use in transmitting alarm to remote location. <br />DISCONNECT SYSTEM: <br />The design of the disconnect system shall permit the easy removal of pumping <br />units for inspection or service. The pump when lowered into place, shall be <br />automatically connected to the discharge piping. There shall be no need for <br />personnel to enter the wet well to inspect or service the pump. Pump shall be <br />securely attached to a sliding guide bracket. A minimum schedule 40 standard <br />stainless steel pipe guide rail shall be furnished and installed by the contractor. <br />The sliding guide bracket shall have non -sparking material at the point of contact <br />with the guide rail to prevent spark ignition of explosive wet well gases during <br />pump installation and removal. A cast iron discharge elbow, located on the floor <br />of the wet well, will receive the pump discharge when the pump is lowered into <br />place. The receiving edge of the discharge elbow shall be fitted with non -sparking <br />material to prevent spark ignition of explosive wet well gases during pump <br />installation and removal. The pump discharge shall be fitted with a resilient seal <br />which provides a positive hydraulic seal for maximum pump system efficiency. <br />The lower guide rail bracket shall be mounted by the pump manufacturer on a steel <br />base plate, in alignment for proper operation of the disconnect system. The base <br />assembly shall provide stable, three point support of the pumping unit during pump <br />operation. The entire quick disconnect pumping system must be listed and labeled <br />by underwriter's laboratory (UL) as suitable for operation in Class 1, Group D, <br />Division 1 located as defined in Section 501-8 of the National Electric Code. <br />DISCHARGE PIPING: <br />The discharge piping for each pump shall include cast iron discharge elbow, <br />schedule 80 PVC and flanged fittings, 175 PSI flanged check valve with spring assist, <br />especially designed to handle raw sewage, 125 PSI flanged gate valve and flexible coupling. <br />WET WELL: <br />The wet well shall be constructed of 6 feet diameter Class III reinforced concrete <br />pipe (R.C.P.) with PCC base, fully lined with coal tar epoxy or reinforced fiberglass <br />on a PCC base. <br />TESTING: <br />The entire installation shall be tested in the presence of the owner. Panel and circuits <br />shall be tested for shorts and ground with mains and disconnect from feeders. Each <br />individual circuit shall be tested at the panel with all equipment connected for proper <br />operation. The actual flow rates shall be measured for all phases of operation. The <br />actual flow rates shall be within 10% of the specified design. flow rates when tested <br />at the design head. <br />OPERATION AND MAINTENANCE: <br />Contractor shall furnish the owner three (3) bound sets of 0 & M manuals <br />including complete wiring diagram, exploded view of all electrical components, pump <br />equipment and pump curve, all part numbers and one laminated wire schematic in <br />pocket on panel door. He shall also provide the owner the name, address <br />and phone number of the nearest local distributors for parts. <br />WARRANTY' <br />All material including pumps, valves, electrical controls, etc. shall be warranted for <br />a minimum one-year period from the date of final acceptance by the Owner. <br />ASSOCIATES, INC. <br />P.O.Box see <br />San Andreas, Ca. 95249 <br />Ph. (209) 754-3588 <br />FRENCH CAMP GOLF & R. V. PARK <br />MAIN SANITARY SEWER PUMP STATION <br />DATE: 4L/Z7 195 <br />/ RCE NO: 12741 <br />EXP. DATE: 3/31/94 <br />DESIGN ENGIN R <br />