My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU-3392
PublicWorks
>
VAULT MAPS
>
Subdivision - SU (GIS FILES)
>
SU-3222-3451
>
SU-3392
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/15/2024 10:31:27 AM
Creation date
10/15/2024 10:31:21 AM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
Page 1 of 1
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
B <br />d D D ► THRUST BLOCK AREA IS BASED ON THE SIZE OF <br />THE BRANCH LINE. �5 <br />I'll <br />1 1/4- SQUARE PATTERN <br />„SANITARY' OR < 1/8' HIGH m Y , i VAM <br />"STORM" AS <br />APPROPRIATE 1 1/2' 0 - 3 HOLES m Z „ "B.. s = " •.B•," <br />(1 1/2" LETTERS) EQUALLY SPACED Z ` I '' .apADJUST BOX TO GRADE <br />A • A a F PER COUNTYWIDE STANDARDS 3' AC APRON 2-1/2' TYP. <br />14-1/4" TYP FLOWLINE1'x 1 1/4,OC1QO� ° J.� :'A„ "A.,11-11T,OF DITCH,PRY HOLE OQ ❑ O O . � 1' MIN. 1' MIN FINISHED GRADE <br />Fr <br />SU a o 0 0 oOo 0 0 <br />TYPICAL THRUST BLOCK TYPICAL THRUST BLOCK TYPICAL THRUST BLOCK <br />3g8..R 334" R ❑❑ ❑❑ ❑❑ ❑ o c <br />A A QQ Q O BEND TEE OUTLET DEAD END 1Y 7_1/2, $ 9" 9" 5 MAX EDGE OF PVMT <br />3' R O O ❑ _ ti Y AL50 SEE NOTE m <br />M NU O O O ❑ PICK HOLE 45' MAX. <br />(TYP. FOR ALL <br />B ANGLES <br />1/7• PATTERN LETTERS 3/4„ 1/2" <br />STEEL BAR ® 4" 1` DIAMETER PLAN VIEW <br />1" VENT HOL MACHINED <br />COVER LIF Xi b FRAME I--1, 17/37" <br />-1 20" I SEATING <br />MACHINED HOLES 30 5-1/2" 1"--I r1 1/4" -{ �3/4" 1/8" SURFACES 1' MIN. - <br />SEATING --{ 1' ��2 1/8" PLAN SECTION C -C ,y T <br />SURFACES , --�- 3 3/8` .,t 3 1/ TYPICALTHRSE ION THRU <br />27, SECTION B -B i 1/4" f <br />25 51T -"I 1-1 3/8" 2" --{ �--5/8" NOTES <br />' ST <br />25 1 2" MACHINED 18 1/4" 1. ALL THRUST BLOCKS SHALL <br />1/q _T ING SURFACES - 22 1/4' -� BE <br />CSOIL, <br />�/2^�1 f 1 1/4" SECTION A -A 2. RESTRAINT SYSTEM FOR <br />VERTICAL PIPE BENDS SHALL <br />DIAMETER I BE APPROVED BY THE <br />NOTES: AGENCY. <br />SECTION A -A 21 1 2 4 RIBS 0 90' SPACING 1. FRAME & GRATE SHALL BE MANUFACTURED OF CAST IRON CONFORMING 3 FOR PIPES THRUST ESLARGER THANTRAINT 12' <br />NOTES: 32 3/B" TO ASTM A-48-30. SHALL BE DESIGNED ON A <br />2. FRAME AND GRATE SHALL BE HS20-44 RATED. CASE BY CASE BASIS AND <br />1. FRAME AND COVER SHALL BE MANUFACTURED OF CAST IRON NOTES: SECTION A -A 3. FRAME SHALL WEIGH APPROX: 65 LBS. SHALL BE APPROVED BY THE <br />CONFORMING TO ASTM A -48 -CLASS 30. 4. GRATE SHALL WEIGH APPROX. 78 LBS. AGENCY. <br />THRUST BLOCK <br />AREA REQUIRED <br />FITTINGS <br />ALLUWAULt <br />LBS. <br />PER SO777 <br />6" LINE OR SMALLER <br />"A" <br />'•B" <br />22 1 7 <br />1'-6" <br />1'-6" <br />45' <br />2'-0" <br />2'-0" <br />90 <br />3'-0" <br />2'-6" <br />TEE OUTLET <br />'-6" <br />2'-0" <br />DEAD END <br />2'-6" <br />2'-0" <br />8" LINE <br />22 112' <br />90 <br />TEE OUTLET <br />_ <br />6'-Q" <br />DEAD END <br />- <br />10" LIN <br />22 1/7 <br />31-01, <br />2•-0" <br />4 <br />-s"'-0" <br />4'-0"31-61, <br />DEAD N <br />4'_U" <br />3'-6" <br />12" LIN <br />22 1 <br />3'-0" <br />3'-0" <br />45 <br />il 4--0" 11 <br />4'-0" <br />90, <br />T-0" 1 <br />4r_ U? <br />TEE OUTLET <br />5'-0" 1 <br />4'-0" <br />DEAD END <br />5'-0" 1 <br />4'-0" <br />6 ONCRETE COLLAR NOT <br />PLAN <br />II <br />CURB & GUTTER <br />INSTALLATION <br />F tos3/8 <br />m <br />2'-O" MIN. <br />© <br />5' MAX. <br />(U <br />NOTES: <br />17' DIA. <br />MIN. <br />S`0.01 FT/,F7 MIN. <br />1. VALVE BOX AND LID SHALL BE CHRISTY NO. G5 OR AS APPROVED BY THE AGENCY. <br />6" <br />2. ALL LIDS SHALL HAVE MACHINED SEATING SURFACES. <br />12" <br />® VALVE BOX RISERS SHALL BE AS MANUFACTURED FOR THE VALVE BOX SUPPLIED. <br />VALVE BOX RISER TO BE ONE CONTINUOUS PIECE AND CENTERED ON VALVE. <br />SHOULD BE RISER OR W 0, CLASS 100 PVC. <br />SEE NOTE 5. <br />3" <br />4. FOR BLOWOFF INSTALLATION, REFER TO DRAWING NO. CW -W6. <br />CLASS'B" <br />5. ALTERNATIVE VALVE BOX AND RISERS MAY BE USED WHERE APPROVED BY THE AGENCY. <br />REQUIRED WHEN VALVE BOX IS LOCATED IN CONCRETE <br />CONCRETE <br />TYPICAL SECTION <br />2. FRAME AND COVER SHALL BE HS20-44 RATED. 1. FRAME AND COVER SHALL BE MANUFACTURED OF CAST IRON 5, GRATE SHALL BE CHAINED TO FRAME WITH 18" OF 1/4" HEAT-TREATED CHAIN . C <br />CONFORMING TO ASTM A -48 -CLASS 30 6. MAY BE USED IN RIGHT OF WAY WHERE APPROVED BY GOVERNING AGENCY. 4. CONCRETE SHALL BE CLASS B. SIDEWALK AREA. NOTES <br />3. FRAME SHALL WEIGH APPROX. 22 LBS. 2. FRAME AND COVER SHALL BE HS20-44 RATED. m VALVE STEM EXTENSIONS MAY BE USED TO COMPLY WITH 5' MAX. DISTANCE FROM 1❑, GRATE AND FRAME SHALL CONFORM 70 IMPROVEMENT STANDARD N0. CW -M7. <br />COVER SHALL WEIGH APPROX. 7 LBS. 3. FRAME SHALL WEIGH 140 LBS. MINIMUM; 7. COUNTRY OF ORIGIN AND MANUFACTURER SHALL BE CAST INTO FRAME AND GRATE. GRADE TO NUT. m18" PIPE BARREL SHALL BE CLASS III R.C.P., OR CLASS 2 NON -REINFORCED <br />4. FRAME AND COVER SHALL BE COATED WITH BITUMINOUS MATERIAL COVER SHALL WEIGH 130 LBS. MINIMUM. ® 1/4" X 6" U BOLT CAST INTO GRATE AND FRAME B. TRACE WIRE SHALL BE INSTALLED. CONCRETE PIPE AS A MINIMUM. <br />CONFORMING TO A.W.W.A. C203. 4. FRAME AND COVER SHALL BE COATED WITH BITUMINOUS MATERIAL <br />CONFORMING TO A.W.W.A. C203. 3. CATCH BASIN MAY BE USED WHERE APPROVED BY THE AGENCY. <br />5. COUNTRY OF ORIGIN AND MANUFACTURER SHALL BE CAST INTO <br />FRAME AND COVER. Q 5. COUNTRY OF ORIGIN AND MANUFACTURER SHALL BE CAST INTO FRAME AND COVER. CATCH BASIN ASSY TO BE SET 0.5' BELOW FLOWLINE Of DITCH. <br />1 SURVEY MONUMENT 2 MAINTENANCE HOLE4 THRUST BLOCKS <br />1 6 FRAME AND COVER 3 18" STORM DRAIN INLET _ 5 VALVE BOX DETAILS 6 18W STORM DRAIN <br />16 FRAME AND COVER 16 FRAME AND GRATE 16 1 6 16 INLET CATCH BASIN <br />4'x4'-4" CONIC. PAD -I <br />HYDRANT <br />A GROUT SMOOTH ALL EDGES OF PIPE OPENING 30' MIN PUMPER OUTLET FACING STREET <br />MAINTENANCE HOLE <br />FRAME & COVER. ADJUST TO GRADE <br />PER COUNTYWIDE STANDARDS <br />P. L. TOP OF CURB 10 I 7' MIN, <br />�5 REBARS (TYPICAL) <br />16" MIN. 4" MAX. 7 PAVEMENT <br />- <br />fLOWUNE OF 20" MAX. STANDARD <br />❑7 GUTTER -2 - EXPANSION b -1 8 VALVE BOX <br />IXPANSION a <br />JOINT r.. INSTALL GRADE RINGS AS REQUIRED <br />8" MIN JOINT _ _ " FOR GRADE (GROUT IN PLACE) <br />12' MAX. 12" MAXIMUM. <br />---1�- " iAe;.• rGh!Y sft ? T" + ' 4"CLEARANCE HYDRANT " 1--24" MIN-� PRECAST REINFORCED CONCENTRIC <br />COUPLING, UP Of CUTEER CATCHBASIN ASSEMBLY 70 BE SET MECHANICAL JOINT 7c ,, <br />E: <br />ANGLEMETEBY OWNER 1" BELOW FLOW UNE OF GUTTER ❑5 iv R�, CONCRETE CONE <br />2 oE€�o�ER PLAN s <br />.. 30" MIN. rl <br />© '"• ® '`�" rc <br />SERVICE 900 MIN. A I 3' OPENING (SEE NOTE NO 3) SIDEWALK �Y MIN ./-ppENHAT �ING 24" THRUST BLOCK �,� <br />_-,.II 1/ -�'1I '` II Sti o Q ALL JOINTS SHALL BE SET <br />SADDLE ° rc 5 ON FULL MORTARED BED AND <br />BANDED WITH MORTAR ON <br />PLAN VIEW BOTH INTERIOR AND EXTERIOR <br />i 4' DIA. 1/2 DIA t N CONCRETE BLOCK THRUST 4 SURFACES. <br />Q ©/ STANDARD STORM DRNN MANHOLE BOLT• <br />REFER TO STANDARD DRAWING SECTION GATE VALVE BLOCK ` h <br />3 DIA NO. D-17. 4' DIA. BOSS TO HOLD <br />OR SQ GROUT TO FOUNDATI GRATE IN PLACE z GRATE �' ` HAND FINISH SLOPES <br />CORPORATION STOP D%l 2 <br />2" PIPE - 24" DIA. CONIC. lY DIA `�+ W' • I <br />WATER MAIN 3" PIPE (SEE NOTE MIN. <br />N0. 5) S- .01 MIN. ._...( 25 1/Y > MAX <br />,r I ' <br />7 <br />NOTES .,'k " .u'aF�D 6 4. <br />NOTES: BOSS ONC . E 1 C <br />33" 1. HYDRANT MODEL TO BE APPROVED BY WATERLOO-MORADA FIRE DISTRICT. I`- 5'- 10" <br />28 1" DIA. MIN. UNE TO EACH LOT. CUSS "B" CONCRETE a 3" 2. SEE STANDARDS FOR LOCATION OF HYDRANT. NOTES: <br />SERVICE PIPE TO 8E CONTINUOUS (NO JOINTS) BETWEEN MAIN AND ANGLE METER STOP. 8• 8' SECTION 3. HYDRANTS SHALL BE CLEAN AND FREE OF CONCRETE. UNDISTURBED EARTH <br />90' COMP. x COMP. ELL., 'JAMES JONES' J-2610 W/J-2806 ' ' 4. HYDRANTS SHALL BE PAINTED YELLOW, IN ACCORDANCE WITH AGENCY STANDARDS. 1. FOR PIPES 33' DIAMETER AND SMALLER. <br />INSERTS MAY BE USED WHERE APPROVED BY AGENCY. 6" DIA. PVC PIPE (AWWA C-900 WITH CIP EQUIVALENT O.D.) <br />METERS SHALL BE FURNISHED BY THE DEVELOPER. I I I 86 FIRE HYDRANT LATERALS GREATER THAN 100 LF, SHALL HAVE A GATE VALVE INSTALLED Q ECCENTRIC REINFORCED CONCRETE CONE MAY BE USED ON APPROVAL OF AGENCY <br />GATE VALVE IS REQUIRED PRIOR TO ANY POINT OF CONNECTION. 5 MIN. -+j I'�5' MIN. �'I NEAR THE FIRE HYDRANT AS APPROVED BY THE AGENCY. PRECAST REINFORCED CONCRETE MAINTENANCE HOLE UNIT SHALL CONFORM <br />5. THE LOCATION OF THE SERVICE SADDLE SHALL BE A MIN. OF 24" FROM ANOTHER PLAN OF FRAME © BREAK AWAY SPOOL WITH HOLLOW BREAK -OFF BOLTS WITH NUT ON BOTTOM AT © TO A.S.T.M. C-478 <br />SERVICE SADDLE, BELL, SPIGOT, OR OTHER FITTING. SECTION A -A SECTION A -A CONNECTION TO HYDRANT. <br />© METER BOX MAY BE PLACED ADJACENT TO PROPERTY OR EASEMENT LINE WITH++ ++ NOTES: ® EXPANSION JOINT MATERIAL WHERE HYDRANT IS PLACED IN CONCRETE. ® CONSTRUCT FLEXIBLE PIPE JOINT AT 2 FEET MAXIMUM FROM BASE <br />PRIOR APPROVAL OF THE AGENCY. PIPES LARGER THAN PIPES 24 TO 36 DIA. OF MAINTENANCE HOLE FOR RIGID PIPE. (EXCEPT CAST -IN-PLACE). <br />® METER BOX PER AGENCY STANDARDS. ALL BOXES LOCATED IN DRIVEWAY AREAS TO 36" DIA. 1. 2 canis COATSOFS ALL B H DIPWITH <br />PED <br />HAVE TRAFFIC COVERS. A ©INTERIOR COATING WHERE REQUIRED BY AGENCY. <br />B. APPURTENANCES PER AGENCY REQUIREMENTS MINIMUM OF 180 OR GALVANIZED. <br />9. LOCATOR WIRE WHERE REQUIRED BY AGENCY2. GRATE, FRAME AND SIDE INLET SHALL CONFORM TO © RUBBER RING WATERSTOP OR ADAPTER REQUIRED FOR <br />NOTES: SOUTH BAY FOUNDRY A-645 FRAME WITH EITHER A-390 PVC PIPE INSTALLATIONS. <br />1. THE FOUNDATON SHALL BE A MINIMUM OF 5' FOR 44" O.D. PIPE AND SMALLER. RMTED OR A -390-M FABRICATED STEEL GRATE. <br />2. FOR PIPE LARGER THAN 4C O.D., THE FOUNDATION SHALL EXTEND A MINIMUM 3. GRATE SHALL BE CHAINED TO FRAME. 7. FOR UNPAVED AREAS LEAVE MAINTENANCE HOLE ABOVE GROUND AS REQUIRED BY AGENCY <br />OF rs BEYOND EACH SIDE OF THE PIPE. 4. GRATE SHALL BE DEPRESSED 1" BELOW GUTTER <br />3. OPENING TO BE 3' LONG X (I.D. OF PIPE) WIDE, UP TO 38^ I.D. PIPE. PROFILE GRADE. <br />5 <br />FOR PIPES LARGER THAN 36" I.D., OPENING TO BE 36" DIAMETER OR SQUARE. . 24" PIPE BARREL SHALL BE CLASS II R.C.P. OR <br />CUSS 2 OR 3NON-REINFORCED CONCRETE' PIPE, <br />V <br />8 SADDLE -TYPE MANHOLE FOR 9 TYPE 1 10 FIRE HYDRANT ASSEMBLY 1 1 TYPE 1 MAINTENANCE HOLE <br />0 7 WATER SERVICE INSTALLATION 16 PIPE 24W DIA. AND LARGER 16 CURB INLET CATCH BASIN 1 6 QS) <br />16 <br />N <br />REVISION DATE DESCRIPTION APPROVED DATE COMPUTED: MJBpFEsS/py IMPROVEMENT PLANS FOR DATE:10/28/1999 <br />- CELLA BARB <br />�Q DRAWN BY: RAE/RDF/RHK �� R 9 ql BLACK OAK ESTATES SCALE: LB <br />- ASSOCIATES ~ Z z / z a / HORIZONTAL NTS OF <br />o_ DESIGN BY: SRB NO. C 047099 �ii VERTICAL: NONE <br />ENGNEERNG•PLA/WING. LANDSCAPE NtCNIWURE. WATER RESWRCES. SURVEYING 1% EXP. 12/31/99 STANDARD DETAILS <br />*sp CIV1�- �a�P CADFILE: STD-DET.DWG 28 <br />PROJ. ENGR. SRB 777 CAMPUS COMMONS ROAD SUITE 200 SACRAMENTO, CA 95825 gTFCFCAU COUNTY OF SAN JOAQUIN CALIFORNIA JOB NO: 530084.01 <br />PHONE (916) 565-7446 FAX (916) 565-7452 <br />0 <br />PRINTED: THUR 10/28/1999 14:11:05 <br />
The URL can be used to link to this page
Your browser does not support the video tag.