Laserfiche WebLink
L1 <br />48OV, 30 L2 <br />L3 <br />120V <br />r E AT 10 <br />= IS <br />�111���LLLJJIII �E AT 80 P9 <br />F <br />PRESSURE SMMH <br />TRI <br />— <br />WARRICK CONTROLS L G HLJ <br />SERIES 16DM RELAY <br />2"PIPE THREAD <br />WITH TANK TAP <br />GROUND CONNECTOR <br />AND 2 LEVEL PROBES <br />120V, 10 <br />240V, 10, 20A <br />BACK SPIN <br />TIMER <br />r-_1 <br />TR1 <br />RUN <br />TO COMPRESSOR <br />STARTER <br />(3) O.L. <br />TR1 <br />1S RUN <br />M1 <br />1S <br />2S <br />-� 2S <br />2S <br />WATER PUMP CONTROL DIAGRAM <br />L1 <br />N <br />L1 <br />N <br />ZPA <br />CHLORINATOR CONTROL DIAGRAM <br />COMPRESSOR CONTROL DIAGRAM <br />PUMP MOTOR <br />75 HP <br />j8" <br />116.25" <br />PIPE <br />EXHAUST PIPE WITH INSULATING <br />TEMPERATURE SHIELDING <br />E.G. SET WEATHERPROOF SOUND SHIELD <br />0 0 0 HOUSING WITH SUPER CRITICAL SILENCER <br />ACCESS DOOR <br />INTEGRALLY MOUNTED WITHIN THE HOUSING <br />® WEATHERPROOF SUBBASE FUEL TANK <br />HOUSING CHANNEL BASE <br />ss. <br />(6) 3/4"x8" ANCHOR <br />BOLTS (3 PER SIDE) <br />W/5" MIN. EMBEDMENT <br />THRU CALDYN VIBRATION <br />INSULATORS #VJSD <br />132"� 8"x8" THICKENED <br />EDGE ALL AROUND <br />TYP. 5-1/2" THICK CONC. ( 112"SQ.02"THICK CONC. <br />SLAB W/W1.4xW1.4/6x6 —{ PADS AT ANCHOR <br />WWM IN CENTER I BOLTS. TYP. OF (4) <br />NOMINAL DIMENSIONS/WEIGHT: DIMENSONS ABOVE <br />TOTAL WEIGHT = 5400 LBS. <br />KOHLER#135RZD. <br />NOTES: <br />1. PROVIDE COMPLETE INSTALLATION DRAWING, UNIT WEIGHT, DIMENSIONS, <br />ANCHORAGE POINTS, CENTER OF GRAVITY, ETC. TO ENGINEER FOR REVIEW <br />AND APPROVAL. <br />2. ALL FUEL PIPING TO BE SELF CONTAINED AND INTEGRAL WITH THE <br />GENERATOR SET. ALL FUEL PIPING SHALL BE IN ACCORDANCE WITH CFC <br />SEC. 7901 AND NFPA 37 SEC. 5-7.2. <br />3. ALL EXHAUST SYSTEM SHALL BE INTEGRAL WITH THE GENERATOR SET <br />AND IN COMPLIANCE WITH NFPA 37 SEC. 6-3, NFPA 110 SEC. 5-10.5 AND <br />CMC SEC. 609.10. <br />EMERGENCY GENERATOR: <br />1. ALL CONDUIT CONNECTIONS TO THE EMERGENCY GENERATOR SHALL BE <br />THROUGH FLEXIBLE, LIQUID TIGHT, STEEL CONDUITS. <br />EMERGENCY GENERATOR TESTING: <br />1. IT IS FURTHER CLARIFIED, IN ADDITION TO ELECTRICAL SPECIFICATIONS <br />PARAGRAPHS 2.25 "ONSITE TESTING", THE FOLLOWING ADDITIONAL TESTS <br />SHALL BE CARRIED OUT: <br />0. COLD START PER NFPA 110 SECTION 5-13.2.3. <br />CHLORINATOR b. CYCLE CRANK PER NFPA 110 SECTION 5-13.2.8. <br />PUMP C. FULL LOAD TEST PER NFPA 110 SECTION 5-13.2.5. <br />d. ALL SAFETY DEVICES PER NFPA 110 SECTION 5-13.2.9. <br />1/6 HP <br />AIR COMPRESSOR <br />PUMP <br />THE COMPRESSOR UNIT <br />INCLUDES A STARTER, ADD <br />AND BLEED AIR VALVES, <br />AND LEVEL PROBES <br />TO TURN THE COMPRESSOR <br />ON AND OFF <br />$ LIGHT SWITCH — SPST <br />>Ct 120 VOLT DUPLEX WALL OUTLET <br />O JUNCTION BOX <br />EF FUSED DISCONNECT SWITCH <br />o' MANUAL MOTOR STARTER/DISCONNECT <br />MOTOR OUTLET <br />- - - CONDUIT CONCEALED IN FLOOR OR UNDERGROUND <br />SEALTITE FLEX CONNECTION <br />® DISTRIBUTION PANEL <br />LIGHTING PANEL <br />U.O.N. UNLESS OTHERWISE NOTED <br />CO CONDUIT ONLY <br />WP WEATHERPROOF <br />O GROUND ROD 3/4"o x 8'-0" LONG WITH <br />CHRISTY GROUNDWELL CONCRETE BOX <br />® ELAPSED TIME METER, NON—RESET 0-9999 HOURS <br />LEGEND <br />HCS ENGINEERING, INC. <br />CONSULTING ELECTRICAL ENGINEERS <br />4651 QUAIL LAKES DRIVE <br />STOCKTON, CA 95207 (209)478-8270 <br />PROJ.---=202.--DES.- L -ENG._ Rte_ <br />� I <br />4 <br />n�T^'TI <br />E3 <br />�� <br />o <br />Q <br />I <br />P <br />n�T^'TI <br />E3 <br />�� <br />o <br />Q <br />V <br />P <br />W <br />n�T^'TI <br />E3 <br />