Laserfiche WebLink
GENERAL NOTES <br />1. THE CONTRACTOR AGREES THAT, IN ACCORDANCE WITH GENERALLY <br />ACCEPTED CONSTRUCTION PRACTICES, THE CONTRACTOR WILL BE REQUIRED <br />TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE <br />CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT, <br />INCLUDING SAFETY OF ALL PERSONS AND PROPERTY. THIS REQUIREMENT <br />SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL <br />WORKING FURS. THE CONTRACTOR FURTHER AGREES TO DEFEND, INDEMINIFY <br />AND HOLD OWNER, CITY, COUNTY AND ENGINEER HARMLESS FROM ANY AND <br />ALL L IABIL I TY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE <br />OF WORK ON THIS PROJECT, EXEAPTING LIABILITY ARISING FROM THE <br />SOLE NEGLIGENCE OF ENGINEER. <br />2. EXCAVATIONS SHALL BE ADEQUATELY SHORED, BRACED AND SHEETED <br />SO THAT THE EARTH WILL NOT SLIDE OR SETTLE AND SO THAT ALL <br />EXISTING IMPROVEMENTS OF ANY KIND WILL BE FULLY PROTECTED FROM <br />DAMAGE. ANY DAMAGE RESULTING FROM A LACK OF ADEQUATE SHORING, <br />BRACING AND SHEETING, SHALL BE THE RESPONSIBILITY OF THE <br />CONTRACTOR AND HE SHALL EFFECT NECESSARY REPAIRS OR <br />RECONSTRUCTION AT HIS OWN EXPENSE. WHERE THE EXCAVATION FOR A <br />CONDUIT TRENCH, AND/OR STRUCTURE IS FIVE FEET OR MORE IN DEPTH, <br />THE CONTRACTOR SHALL PROVIDE ADEQUATE SHEETING, SHORING AND <br />BRACING OR EOUI VALENT METHOD, FOR THE PROTECTION OF LIFE, OR L ME, <br />WHICH SHALL CONFORM TO THE APPLICABLE CONSTRUCTION SAFETY ORDERS <br />OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STA TE OF CALIFORNIA. <br />THE CONTRACTOR SHALL ALWAYS COAPL Y WITH OSHA REQUIREMENTS. <br />J. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN PERMITS <br />NECESSARY TO PERFORM THE WORK SHOWN /N THESE PLANS FROM THE <br />APPROPRIATE AGENCIES. <br />4. THE CONTRACTOR SHALL TAKE EFFECTIVE ACTION TO PREVENT THE <br />FORMATION OF AIRBORNE DUST NUISANCE AND SHALL BE RESPONSIBLE FOR <br />ANY DAMAGE RESULTING FROM/ HIS FAILURE TO DO SO. <br />5. THE CONTRACTOR SHALL PROVIDE FOR INGRESS AND EGRESS FOR <br />PRIVATE PROPERTY ADJACENT TO WORK THROUGHOUT THE PERIOD OF THE <br />CONSTRUCTION. <br />6. THE CONTRACTOR SHALL PROVIDE ALL LIGHTS, SIGNS, BARRICADES, <br />FLAGGERS OR OTHER DEVICES NECESSARY TO PROVIDE FOR SAFETY, <br />7. THE CONTRACTOR SHALL POST EMERGENCY TELEPHONE NIAIIBERS FOR POLICE, <br />FIRE, AMBULANCE, AND THOSE AGENCIES RESPONSIBLE FOR MAINTENANCE <br />OF UTILITIES IN THE VICINITY OF JOB SITE. <br />B. ANY EXTRA CONSTRUCTION STAKING NECESSITATED SOLELY BY THE <br />CONTRACTOR'S NEGLIGENCE WILL BE CHARGED TO THE CONTRACTOR ON A <br />TIME AND EXPENSES BASIS, AND PAID FOR BY THE CONTRACTOR. <br />9. STATIONING HEREON IS ALONG STREET CENTERLINE UNLESS OTHERWISE <br />SHOWN OR INDICATED. <br />10. ALL RETURN RADII AND CURB DATA ARE TO FACE OF CURB. <br />11. ALL QUANTITIES AND PAY ITEMS ARE AND WILL BE BASED ON HORIZONTAL <br />MEASUREMENTS. <br />12. LENGTHS OF SANITARY SEWERS AND STORM DRAINS ARE HORIZONTAL <br />DISTANCES FROM CENTER TO CENTER OF STRUCTURES, ROUNDED OFF TO THE <br />NEAREST FOOT. <br />13. EXISTING UNDERGROUND UTILITIES AND IMPROVEMENTS ARE SHOWN /N <br />THEIR APPROXIMATE LOCATIONS BASED UPON RECORD INFORMATION <br />AVAILABLE TO THE ENGINEER AT THE TIME OF THE PREPARATION OF THESE <br />PLANS. LOCATIONS MAY NOT HAVE BEEN VERIFIED IN THE FIELD AND NO <br />GUARANTEE IS MADE AS TO THE ACCURACY OR COMPLETENESS OF THE <br />INFORMATION SHOWN. THE CONTRACTOR SHALL NOTIFY UTILITY COMPANIES <br />AT LEAST (3) WORKING DAYS IN ADVANCE OF CONSTRUCTION TO FIELD <br />LOCATE UTILITIES. CALL UNDERGROUND SERVICE ALERT (U.S.A.) AT <br />800-642-2444. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO <br />DETERMINE THE EXISTENCE AND LOCATION OF THOSE UTILITIES SHOWN ON <br />THESE PLANS OR INDICATED IN THE FIELD BY LOCATING SERVICES. <br />ANY ADDITIONAL COSTS INCURRED AS A RESULT OF CONTRACTOR'S FAILURE <br />TO VERIFY LOCATIONS OF EXISTING UTILITIES PRIOR TO BEGINNING OF <br />CONSTRUCTION IN THEIR VICINITY SHALL BE BORNE BY THE CONTRACTOR <br />AND ASSUMED INCLUDED AND MERGED IN THE CONTRACT UNIT PRICE. <br />14. ALL EXISTING UTILITIES AND IMPROVEMENTS THAT BECOME DAMAGED <br />DURING CONSTRUCTION SHALL BE COMPLETELY RESTORED TO THE <br />SATISFACTION OF THE LOCAL AGENCY ENGINEER, AT THE CONTRACTOR'S <br />SOLE EXPENSE. <br />15. ANY RELOCATION OF PUBLIC UTILITIES SHALL BE CONDUCTED IN <br />ACCORDANCE WITH ANY AND ALL REQUIREMENTS OF THE UTILITY COMPANY <br />INCLUDING FEES, BONDS, PERMITS AND WORKING CONDITIONS, ETC. THIS <br />WORK SHALL BE DONE AT NO EXPENSE TO THE UTILITY COMPANY. THE <br />OWNER SHALL PAY THE COST OF ALL SUCH RELOCATIONS WORK INCLUDING <br />FEES, BONDS, PERMITS, ETC. <br />16. IF ARCHAEOLOGICAL MATERIAL ARE UNCOVERED DURING GRADING, <br />TRENCHING OR OTHER EXCA VA TION, EARTHWORK WITHIN 100 FEET OF THESE <br />MATERIALS SHALL BE STOPPED UNTIL A PROFESSIONAL ARCHAEOLOGIST WHO <br />IS CERTIFIED BY THE SOCIETY OF CALIFORNIA ARCHAEOLOGY (SCA) <br />AND/OR THE SOCIETY OF PROFESSIONAL ARCHAEOLOGY (SOPA) HAS HAD <br />AN OPPORTUNITY TO EVALUATE THE SIGNIFICANCE OF THE FIND AND <br />SUGGEST APPROPRIATE MITIGATION MEASURES IF THEY ARE DEEMED <br />NECESSARY. <br />17. RUGGERI - JENSEN - AZAR AND ASSOCIATES (RJA) DOES NOT SPECIFY NOR <br />RECOMMEND THE USE OR INSTALLATION OF ANY MATERIAL OR EQUIPMENT <br />WHICH IS MADE FROM, OR WHICH CONTAINS ASBESTOS FOR USE IN THE <br />CONSTRUCTION OF THESE IMPROVEMENT. ANY PARTY INSTALLING OR USING <br />SUCH MATERIALS OR EQUIPMENT SHALL BE SOLELY RESPONSIBLE FOR ALL <br />INJURIES, DAMAGES, OR L IAB I L /TIES, OF ANY KIND, CAUSED BY THE USE <br />OF SUCH MATERIALS OR EQUIPMENT. THE PROVISIONS OF THIS NOTE SHALL <br />APPL Y UNLESS THEY ARE EXPRESSLY WAIVED IN WRITING BY <br />RUGGERI - JENSEN - AZAR AND ASSOCIATES. <br />18, THE CONTRACTOR SHALL MEET AND FOLLOW ALL NPDES REQUIREMENTS IN <br />EFFECT AT THE TIME OF CONSTRUCTION, <br />19. SHOULD I T APPEAR THAT THE WORK TO BE DONE OR ANY MATTER RELATI VE <br />THERETO IS NOT SUFFICIENTLY DETAILED OR EXPLAINED ON THESE <br />PLANS, THE CONTRACTOR SHALL CONTACT RJA AT (925) 227-9100 FOR <br />SUCH FURTHER EXPLANATIONS AS MAY BE NECESSARY. <br />PROJECT GENERAL NOTES <br />1, ALL WORK, EXCEPT SANITARY SEWER AND WATER, SHALL CONFORM TO SAN <br />JOAQUIN COUNTY, DEPARTMENT OF PUBLIC WORKS STANDARD <br />SPECIFICATIONS AND DETAILS PER CURRENT EDITION. THE IMPROVEMENTS <br />ARE SUBJECT TO THE INSPECTION AND APPROVAL OF THE COUNTY PUBLIC <br />WORKS DIRECTOR. CONTACT COUNTY PUBLIC WORKS DEPARTMENT TWO <br />WORKING DAYS (48 HOURS) PRIOR TO THE START OF ANY WORK TO ARRANGE <br />FOR INSPECTION. <br />2. ALL SANITARY SEWER AND WATER WORK SHALL BE DONE IN ACCORDANCE <br />WITH CITY OF TRACY, DEPARTMENT OF PUBLIC WORKS STANDARDS & <br />SPECIFICATIONS, CURRENT EDITION. THE IMPROVEMENTS ARE SUBJECT TO <br />THE INSPECTION AND APPROVAL OF THE CITY PUBLIC WORKS DIRECTOR. <br />CONTACT CITY PUBLIC WORKS DEPARTMENT TWO WORKING DAYS (48 BURS) <br />PRIOR TO THE START OF ANY SANITARY SEWER AND WATER WORK TO <br />ARRANGE FOR INSPECTION. <br />J. THE CONTRACTOR SHALL OBTAIN PERMITS FROM THE CITY OF TRACY AND <br />SAN JOAQUIN COUNTY PUBLIC WORKS DEPARTMENT PRIOR TO BEGINNING <br />WORK. <br />4., IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO IMMEDIATELY NOTIFY <br />THE COUNTY OR THE CITY, AND RUGGERI-JENSEN-AZAR AND ASSOCIATES, <br />UPON DISCOVERY OF ANY CONFLICTS WITH THE PLANS, SPECIFICATIONS OR <br />FIELD CONDITIONS. ANY DEVIATIONS OR CHANGES IN THESE PLANS <br />WITHOUT OFFICIAL APPROVAL OF THE DESIGN ENGINEER SHALL ABSOLVE <br />THE DESIGN ENGINEER OF ANY AND ALL RESPONSIBILITY OF SAID <br />DEVIATION OR CHANGE. <br />5, THE CONTRACTOR SHALL NOT DESTROY ANY PERMANENT SURVEY POINTS <br />WITHOUT THE CONSENT OF THE COUNTY SURVEYOR. ANY PERMANENT <br />MONIAMIENTS OR POINTS DESTROYED SHALL BE REPLACE BY A L I CENSED <br />CIVIL ENGINEER AUTHORIZED TO DO SURVEYING, OR A LICENSED LAND <br />SURVEYOR AT THE CONTRACTOR'S EXPENSE, BEFORE ACCEPTANCE OF <br />IMPROVEMENTS BY SAN JOAQUIN COUNTY. <br />6. ALL CONSTRUCTION STAKING SHALL BE DONE BY A REGISTERED CIVIL <br />ENGINEER, AUTHORIZED TO DO SURVEYING OR A LICENSED LAND SURVEYOR. <br />7. EXISTING UTILITIES ARE PLOTTED FROM AVAILABLE RECORDS. THE <br />CONTRACTOR SHALL TAKE PRECAUTIONARY MEASURES TO PROTECT THESE <br />UTILITIES. THE CONTRACTOR SHALL NOT DO ANY EXCAVATIONS UNTIL ALL <br />UTILITY AGENCIES OF SAN JOAQUIN COUNTY AND THE CITY OF TRACY HA VE <br />BEEN NOTIFIED AND HAVE BEEN GIVEN THE OPPORTUNITY TO MARK THEIR <br />FACILITIES IN THE FIELD. <br />8. CONTRACTOR SHALL CONTROL DUST AT ALL TIMES DURING CONSTRUCTION AS <br />REQUIRED BY THE COUNTY OF SAN JOAQUIN. <br />9. PRIOR TO TRENCHING FOR ALL UTILITY PIPE, THE CONTRACTOR SHALL <br />VERIFY, IN THE FIELD, THE SIZE AND LOCATION OF THE EXISTING PIPE <br />AT THE POINT OF CONNECTION. ANY DEVIATION FROM THE PLANS SHALL <br />BE RESOLVED BY THE DESIGN ENGINEER PRIOR TO TRENCHING. CONTRACTOR <br />SHALL BE RESPONSIBLE FOR COORDINATION OF FIELD VERIFICATION. <br />DESIGN ENGINEER SHALL BE ALLOWED REASONABLE TIME FOR CONFLICT <br />RESOLUTION. <br />10. MANHOLES, VALVES, CLEANOUTS, ETC. SHALL BE BROUGHT TO FINISH GRADE <br />BY THE CONTRACTOR AFTER THE FINAL PAVING COURSE IS PLACED. WATER <br />VALVES AAIST REMAIN ACCESSIBLE AT ALL TIMES DURING CONSTRUCTION. <br />11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING THE NECESSARY <br />PUBLIC AND PRIVATE ENTITIES, WHO HAVE AN INTEREST IN THE <br />CONSTRUCTION OF THESE IMPROVEMENTS AS IT IMPACTS THEM, IN A TI MEL Y <br />MANNER TO ALLOW THEM TO SEND THE NECESSARY REPRESENTATIVES TO THE <br />JOB SITE FOR INSPECTION AND OBSERVATION PURPOSES. <br />12. THE NL#A9ER AND LOCATIONS OF CONSTRUCTION STAKES SHALL BE <br />DETERMINED BEFORE THE CONSTRUCTION BEGINS. ALL STAKING REQUESTS <br />SHOULD BE DIRECTED TO THE DESIGN ENGINEER A MINIMUM OF TWO <br />WORKING DAYS PRIOR TO ACTUAL NEED. ANY ADDITIONAL STAKING OR <br />RESTAKING WILL ONLY BE DONE AS DIRECTED AND AUTHORIZED BY THE <br />OWNER OR HIS AUTHORIZED AGENT. RESTAKING WILL BE BILLED TO THE <br />CONTRACTOR. <br />13. THE EXISTING TOPOGRAPHY AND IMPROVEMENTS SHOWN ON THESE PLANS ARE <br />BASED ON A FIELD SURVEY DATED MARCH 1993. <br />CONSTRUCTION NOTES <br />1. ALL CONSTRUCTION MATERIALS AND METHODS SHALL COMPLY WITH THE <br />ORDINANCES, SPECIFICATIONS, AND STANDARDS OF SAN JOAQUIN COUNTY <br />AND THE CITY OF TRACY (WATER AND SEWER ONLY), EXCEPT AS NOTED <br />BELOW FOR SPECIFIC UTILITIES. <br />2. TRAFFIC CONTROL, MAINTENANCE AND OPERATION SHALL COMPL Y WITH THE <br />FOLLOWING STATE STANDARD SPECIFICATION: SECTION 7-1.09 "PUBLIC <br />SAFETY', SECTION 7-108 "PUBLIC CONVENIENCE", AND SECTION 12 <br />'CONSTRUCTION AREA TRAFFIC CONTROL DEVICES'. CONTRACTOR SHALL BE <br />RESPONSIBLE FOR PROVIDING AND MAINTAINING ALL NECESSARY TRAFFIC <br />CONTROL, INCLUDING TEMPORARY STRIPING, INSTALLATION OF SEMI <br />PERMANENT TRAFFIC CONTROL DEVICES, AT ALL TIMES. <br />J. ALL TRENCH EXCAVATION OVER FIVE FEET IN DEPTH SHALL BE SHORED IN <br />ACCORDANCE WITH CAL -OSHA "CONSTRUCTION SAFETY ORDERS' CURRENT <br />EDITION. CONTRACTOR MUST HAVE VALID TRENCH SHORING PERMIT ISSUED <br />BY CAL -OSHA. <br />4. CONTRACTOR SHALL PROVIDE A MINI" OF 2 LANES, ONE IN EACH <br />DIRECTION, AT ALL TIMES ON PATTERSON PASS ROAD. <br />SANITARY SEWER <br />1. GRAVITY SANITARY SEWER PIPE AND LATERAL SHALL BE VITRIFIED CLAY <br />PIPE (VCP) PER CITY STANDARD SPECS. 207.01. <br />2. SANITARY SEWER MANHOLE SHALL CONFORM TO THE CITY OF TRACY <br />STANDARD DRAWING NO. 301. <br />J. ALL SANITARY SEWER MAINS SHALL BE TELEVISION INSPECTED, AND PASS <br />A LEAKAGE TEST PRIOR TO ACCEPTANCE BY THE CITY F TRACY. (SEE <br />NOTE NO. 10, APPENDIX 9", CITY OF TRACY DESIGN STANDARDS.) <br />4. ALL SANITARY SEWER LATERALS SHALL HAVE A CLEANOUT ONE FOOT <br />INSIDE THE RIGHT OF WAY. SANITARY SEWER CLEANOUT SHALL CONFORM <br />TO THE CITY OF TRACY STANDARD DRAWING N0, 203, <br />5. THE SANITARY SEWER FORCE MAIN (SSFM) SHALL BE CLASS 50 DUCTILE <br />IRON PIPE (DIP), AND SHALL HAVE A M/N/AAAM COVER OF 42" OVER THE <br />PIPE. <br />6. SSFM FITTINGS SHALL BE MECHANICAL JOINT AND DUCTILE IRON. <br />7. TRENCH BEDDING AND BACKFILL SHALL CONFORM TO THE DETAIL ON SHEET <br />15. <br />STORM DRAIN <br />1. ALL STORM DRAIN SHALL BE REINFORCED CONCRETE PIPE (RC:P) CLASS <br />111, UNLESS OTHERWISE NOTED ON THE PLANS. AT THE CONTRACTOR'S <br />OPTION, AN EQUIVALENT STRENGTH CAST -IN-PLACE CONCRETE PIPE MAY BE <br />USED. <br />2. CATCH BASIN SHALL BE TYPE 2 PER SAN JOAQUIN COUNTY STANDARD <br />DRAWING NO. D-14. <br />J. STORM DRAIN MANHOLES SHALL BE SADDLE TYPE MANHOLE CONFORM/NG TO <br />SAN JOAQUIN COUNTY STANDARD DRAWING NO. D-18. STORM DRAIN M!4 422, <br />129 TO J33 SHALL BE PER STORM DRA / N MANHOLE DETAIL ON SHEET 4. <br />4. FIELD INLET SHALL BE SANTA ROSA PRE -CAST DROP INLETS MODEL "2K",'1M" <br />OR '1R". USE MODEL 02K" FOR 18' SO CONNECTION, MODEL "1M" FOR <br />24' SO CONNECTION AND MODEL '1R' FOR 36' SO CONNECTION. <br />5. TRENCH BEDDING AND BACKFILL SHALL CONFORM TO THE DETAIL ON SHEET <br />14. CLASS 2 AB BEDDING SHALL BE USED IF GROUNDWATER IS ENCOUNTERED <br />DURING INSTALLATION OF THE 72' SO. <br />WATER <br />1. WATER MAIN SHALL BE DUCTILE IRON PIPE (DIP) PER CITY STANDARD <br />SPECS. 207.04 CLASS 50 AND SHALL HAVE A MINIMS COVER OF 42" OVER <br />THE PIPE. <br />2. ALL FITTINGS SHALL BE MECHANICAL JOINT DUCTILE IRON. FITTING <br />WITH VALVE SHALL BE MECHANICAL JOINT BY FLANGE. <br />J. VALVES 10" AND SMALLER SHALL BE RESI L I ENT SEATED GATE VALVE <br />CONFORMING TO THE REQUIREMENTS OF THE CITY OF TRACY STANDARD <br />SPECIFICATIONS. NO VALVE SHALL BE INSTALLED UNTIL APPROVAL FOR <br />THE PARTICULAR BRAND NAME AND MANUFACTURER'S MODEL NUMBER HAS <br />BEEN GRANTED BY THE CITY PUBLIC WORKS DIRECTOR. VALVES 12' AND <br />LARGER SHALL BE BUTTERFL Y VALVES, EPDXY LINED, CONFORMING TO <br />THE REQUIREMENTS OF THE CITY OF TRACY STANDARD SPECIFICATIONS. <br />4. TESTING OF THE PIPE SHALL BE MADE IN ACCORDANCE WITH THE <br />REQUIREMENTS OF SECTION 306.15 OF THE CITY OF TRACY STANDARD <br />SPECIFICATIONS. ALL PIPES SHALL BE TESTED AT THE PRESENCE OF THE <br />CITY PUBLIC WORKS DIRECTOR OR HIS REPRESENTATIVE. TESTING OF <br />THE PIPE SHALL BE DONE BEFORE CONNECTION TO THE EXISTING WATER <br />MA / N AND AFTER COMPACTION OF THE BASIC MATERIAL. CONTRACTOR SHALL <br />BE RESPONSIBLE FOR THE TESTING, RETESTING AND RECOMPACTIOV OF THE <br />PIPE AS REQUIRED AT HIS OWN EXPENSE TO THE SATISFACTION OF THE <br />CITY ENGINEER. <br />5. PRIOR TO DELIVERY TO THE JOB SITE, THE CONTRACTOR SHALL FURNISH <br />A COMPLETE L IST OF MATERIALS BY MANUFACTURER AND MODEL NUMBER FOR <br />APPROVAL BY THE CITY PUBLIC WORKS DIRECTOR, AND A CERTIFICATE OF <br />COMPLIANCE SHALL BE FURNISHED BY THE MANUFACTURER FOR ALL PIPE <br />FURNISHED. <br />6. ALL WATER SERVICES (DOMESTIC, FIRE, HYDRANTS, ETC.) MUST MAINTAIN <br />12 " CL EARANCE FROM OTHER UT I L I T I ES. <br />7. WATER METER BOXES SHALL BE INSTALLED FOR ALL SERVICES PER Cl TY OF <br />TRACY STANDARD DRAWINGS 403, 405, OR 406. NO WATER METERS WILL BE <br />INSTALLED AT THIS TIME. <br />B. THRUST BLOCKS SHALL BE INSTALLED AT ALL BENDS AND FITTING PER <br />CITY OF TRACY DETAIL /423. <br />9. FIRE HYDRANTS SHALL BE INSTALLED PER CITY OF TRACY DETAIL 1401. <br />10. TRENCH BEDDING AND BACKFILL SHALL CONFORM TO THE DETAIL ON SHEET 5. <br />CONCRETE <br />1. VERTICAL CURB, GUTTER AND SIDEWALK SHALL CONFORM TO SAN JOAQUIN <br />COUNTY STANDARD DRAWING NO. R-6. <br />2. WHEELCHAIR RAMPS SHALL BE CONSTRUCTED AT LOCATIONS SHOWN ON THE <br />PLANS AND SHALL CONFORM TO SAN JOAQUIN COUNTY STANDARD DRAWING NO. <br />R -10A & B. <br />3, EXISTING CURB, GUTTER AND SIDEWALK OUTSIDE THE WORK LIMITS THAT <br />ARE DAMAGED DURING CONSTRUCTION SHALL BE REPLACED BY THE <br />CONTRACTOR AT THE CONTRACTOR'S SOLE EXPENSE AND TO THE <br />SATISFACTION OF THE COUNTY. <br />4. ALL CEMENT TO BE USED SHALL BE TYPE 11 PORTLAND CEMENT CONFORMING <br />TO ASTM C150. PORTLAND CEMENT CONCRETE SHALL BE GRADE B AND HAVE <br />A 28 -DAY MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI. A COPY OF THE <br />CONCRETE TAGS SHALL BE PROVIDED TO THE CITY ENGINEER FOR EACH <br />LOAD OF CONCRETE DELIVERED TO THE PROJECT. <br />5. NEW CONCRETE CURB AND GUTTER SHALL BE TIED TO THE EXISTING <br />CONCRETE CURB AND GUTTER WITH DOWELS. THE DOWELS SHALL BE NO. 4 <br />REBARS WITH A MIN/MIAI LENGTH OF 12 INCHES. THE DOWELS ARE TO BE <br />INSERTED TO A MINIMUM OF 6 INCHES INTO THE EXISTING CONCRETE CURB. <br />6. THE EXPOSED SURFACE OF THE CURB AND GUTTER SHALL BE BROOM FINISH. <br />IMMEDIATELY UPON STRIPPING CURB FORMS AND PRIOR TO BACKFILLING, <br />ALL ROCK POCKETS OR HONEYCOMBS SHALL BE REPAIRED TO THE <br />SATISFACTION OF THE ENGINEER. <br />ASPHALT CONCRETE <br />1. AGGREGATE SUBBASE SHALL BE CLASS 2 AND SHALL CONFORM TO SECTION <br />25 OF THE "STATE OF CALIFORNIA DEPARTMENT OF TRANSPORTATION <br />STANDARD SPECIFICATIONS, JULY 1992. ' AGGREGATE BASE SHALL BE <br />CLASS 2 AND SHALL CONFORM TO SECTION 16 OF THE "STATE OF <br />CALIFORNIA DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS, <br />JULY 1992. 'ASPHALT CONCRETE SHALL BE TYPE A" 3/4' MAXIMbMI, <br />MEDIUM GRADATION AND SHALL CONFORM TO SECTION 39 OF THE STATE OF <br />CALIFORNIA, DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS, <br />JULY 1992. " <br />2. ASPHALT BINDER TO BE MIXED WITH AGGREGATES SHALL BE PAVING <br />ASPHALT AR -8000 AND SHALL CONFORM TO THE REQUIREMENTS OF SECTION <br />92, "ASPHALTS" OF THE STATE STANDARD SPECIFICATIONS. AGGREGATE <br />SHALL BE CLEAN AND FREE FROM DECOMPOSED MATER/ALS, ORGANIC <br />MATERIAL AND OTHER DELETERIOUS SUBSTANCES, AND CONFORMING TO THE <br />REQUIREMENTS OF SECTION 39-2.02, "AGGREGATE" OF THE STATE <br />STANDARD SPECIFICATIONS. <br />J. CONTRACTOR SHALL PROVIDE CONCRETE MIX DESIGN. <br />4. PRIOR TO PLACING THE NEW ASPHALT CONCRETE, A TACK COAT SHALL BE <br />APPLIED TO ALL VERTICAL SURFACES OF EXISTING PAVEMENT, CURBS, <br />GUTTERS AND CONSTRUCTION JOINTS AGAINST WHICH ADDITIONAL ASPHALT <br />CONCRETE IS TO BE PLACED. THE RATE OF APPL ICA TION SHALL BE <br />APPROXIMATELY 0. 10 GALLON PER SQUARE YARD OF SURFACE COVERED. <br />5. ASPHALT CONCRETE SHALL BE SPREAD AND COMPACTED IN ACCORDANCE WITH <br />THE REQUIREMENTS OF SECTION 39-5, "SPREADING AND COMPACTING <br />EQUIPMENT," AND SECTION 39-6, "SPREADING AND COWACTING" OF THE <br />STATE STANDARD SPECIFICATIONS. <br />6. PRIOR TO INSTALLATION OF NEW ASPHALT CONCRETE, CONTRACTOR SHALL <br />COMPACT THE BASE ROCK MATERIALS WITH A VIBRATING ROLLER OR WITH A <br />MECHANICAL TAMPER TO OBTAIN A MINI" OF 95% COMPACTION. THE <br />SURFACE OF THE FINISHED AGGREGATE BASE AT ANY POINT SHALL NOT <br />VARY MORE THAN 0.05 FOOT ABOVE OR BELOW THE GRADE ESTABLISHED ON <br />THE PLANS. THE SPREADING AND COMPACTING OF AGGREGATE BASE SHALL <br />CONFORM TO THE REQUIREMENTS OF SECTION 26-1.035, 26-1.04 AND <br />26-1.05 OF THE STATE STANDARD SPECIFICATIONS. <br />7. EXISTING PAVEMENT OUTSIDE THE WORK LIMITS DAMAGED DURING <br />CONSTRUCTION SHALL BE REPLACED BY AN EQUAL SECTION TO THE <br />SATISFACTION OF THE COUNTY. <br />8. EXISTING AC PAVEMENT SHALL BE SAWCUT ALONG THE PROPOSED EDGE OF <br />REMOVAL TO PROVIDE A NEAT CONFORM TO THE EXISTING AC PAVEMENT, <br />9. AT THE TIME OF DELIVERY OF EACH SHIPMENT OF ASPHALT, THE VENDOR <br />SUPPLYING THE MATERIAL WILL PROVIDE CERTIFIED COPIES OF TEST <br />REPORT. THE TEST REPORT SHALL CONFORM TO THE REQUIREMENTS OF <br />SECTION 92-1. 03, 'TEST REPORT"OF THE STATE STANDARD SPECIFICATIONS. <br />STREET LIGHTS <br />1. ALL STREET LIGHTS SHALL BE CONSTRUCTED TO SAN JOAQUIN COUNTY <br />STANDARD R-32, R-33 AND R-34. <br />2. LUMINAIRES SHALL BE 150 WATT, HIGH PRESSURE SODIUM FOR STREET <br />LIGHTS ON SCHULT£ ROAD, STANFORD ROAD & BERKELEY ROAD AND 250 <br />WATT FOR THE L ICHTS ON PATTERSON PASS ROAD. <br />SIGNING AND STRIPING <br />1. TRAFFIC SIGNS SHALL BE INSTALLED AT LOCATIONS SPECIFIED ON THE <br />PLANS, IN ACCORDANCE WITH THE REQUIREMENTS OF CALTRANS TRAFFIC <br />MANUAL, LATEST EDITION. <br />2, PAVEMENT STRIPING SHALL INCLUDE STOP BARS, CENTERLINE STRIPING <br />OR MARKERS, CROSSWALKS AND ALL OTHER MARKINGS REQUIRED BY THE <br />COUNTY AND AS SHOWN ON THESE PLANS. STRIPING SHALL BE DONE WITH <br />HOT APPLIED THERMOPLASTIC AND REFLECTIVE MARKERS CONFORMING TO <br />THE REQUIREMENTS OF SECTION 84 & 85 OF CAL TRANS SPECIFICATIONS. <br />J. EXISTING STRIPING PROPOSED TO BE REMOVED SHALL BE DONE BY <br />SANDBLASTING. <br />4. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING EXISTING STRIPING, <br />MARKING OR LEGENDS AS NECESSARY PRIOR TO PLACING THE NEW STRIPING, <br />MARK/NG AND LEGENDS AS SHOWN ON THE SIGNING AND STRIPING PLAN TO <br />AVOID CONFL ICTS. <br />EROSION CONTROL NOTES <br />1. EROSION AND SEDIMENT CONTROL MEASURES SHALL BE EFFECTIVE FOR <br />CONSTRUCTION DURING THE RA/NY SEASON (OCTOBER 1 TO APRIL 1). <br />2. NO STORM RUNOFF WATER SHALL BE ALLOWED TO DRAIN DIRECTL Y INTO THE <br />EXISTING UNDERGROUND STORM SYSTEM, THE CALIFORNIA AQUEDUCT OR THE <br />DELTA MENDOTA CANAL BEFORE THE ONSITE STORM DRAIN SYSTEM IS <br />INSTALLED. <br />3. AS SOON AS IS PRACTICAL AFTER THE NEW STORM SYSTEM 1S INSTALLED, <br />THE CATCH BASINS SHALL BE INSTALLED AND STRAW BALES SHALL BE <br />PLACED AROUND THE CATCH BASINS. <br />4. SHOULD THE PROPOSED ONSITE STORM SYSTEM NOT BE INSTALLED BY <br />OCTOBER 1, TEMPORARY SEDIMENT BASINS SHALL BE CONSTRUCTED AROUND <br />THE OPEN/NGS OF ANY EXISTING STORM PIPES WHICH DRAIN THE SITE. <br />5. THE NAME, ADDRESS AND 24 HOUR TELEPHONE NUAeER OF THE PERSON <br />RESPONSIBLE FOR IMPLEMENTATION OF THE EROSION AND SEDIMENTATION <br />CONTROL PLAN SHALL BE PROVIDED TO THE COUNTY. <br />6. ALL EROSION AND SEDIMENTATION CONTROL MEASURES SHALL BE <br />MAINTAINED UNTIL DISTURBED AREAS ARE STABILIZED. CHANGES TO THE <br />EROSION AND SEDIMENTATION CONTROL PLAN SHALL BE MADE TO MEET <br />FIELD CONDITIONS, BUT ONLY WITH THE APPROVAL OF OR AT THE <br />DIRECTION OF THE COUNTY PUBLIC WORKS DIRECTOR. <br />7. DURING THE RAINY SEASON SPECIFIED IN NOTE 1 ALL PAVED AREAS SHALL <br />BE KEPT CLEAR OF EARTH MATERIALS AND DEBRIS. THE SITE SHALL BE <br />MAINTAINED SO AS TO MINIMIZE SEDIMENT LADEN RUNOFF FROM ENTERING <br />ANY STORM DRAINAGE SYSTEM. <br />8. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO INSPECT AND REPAIR <br />ALL EROSION CONTROL FACILITIES AT THE END OF EACH WORK DAY DURING <br />THE RAINY SEASON. <br />9. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROTECT TEMPORARY <br />BARROW AREAS AND/OR STOCKPILES WITH APPROPRIATE EROSION CONTROL <br />MEASURES SATISFACTORY TO THE COUNTY PUBLIC WORKS DIRECTOR. <br />10. ALL EROSION CONTROL DEVICES SHALL BE REMOVED AND DISPOSED OF BY <br />THE CONTRACTOR UPON COMPLETION OF THE PROJECT. <br />11. CONTRACTOR SHALL TAKE MEASURES NECESSARY TO PROHIBIT NON -STORM <br />WATER DISCHARGES FROM ENTERING THE STORM SYSTEM OR ADJACENT <br />WATERWAY (I.E. CLEANING OF EQUIPMENT, WASHING OF STREETS AND <br />STORAGE OF EXCESS MATERIALS). <br />LIST OF CONTACTS <br />OWNER <br />DESIGN ENGINEER <br />TRAFFIC SIGNAL <br />TELEPHONE <br />STREETS -STORM DRAIN <br />TRAFFIC SIGNALS <br />GAS - ELECTRICITY <br />SANITARY SEWER <br />WATER <br />KING & LYONS <br />47775 FREMONT BLVD. <br />FREMONT, CA 94538 <br />(510) 656-1900 <br />RUGGERI-JENSEN AZAR & ASSOCS. <br />6601 OWENS DR., #155 <br />PLEASANTON, CA 94588 <br />(925) 227-9100 <br />CCS <br />6 CROW CANYON COURT <br />SAN RAMON, CA 94583-1621 <br />(925) 314-1220 <br />PACIFIC BELL <br />44 W. YOKUTS AVE. <br />STOCKTON, CA 95207 <br />(209) 474-4742 <br />SAN JOAQUIN COUNTY <br />1810 HAZEL TON AVE. <br />STOCKTON, CA. 95207 <br />(209) 468-3120 <br />PG&E <br />55 E. TENTH ST <br />TRACY, CA. 95376 <br />(209) 836-0440 <br />CITY OF TRACY <br />520 TRACY BLVD. <br />TRACY, CA. 95376 <br />(209) 831-4420 <br />CITY OF TRACY <br />520 TRACY BLVD. <br />TRACY, CA. 95376 <br />(209) 831-4420 <br />RECORD DRAWINGS <br />These Record Drawings have been prepared based <br />on information submitted by others, partially or <br />totally. While this information is believed to be <br />reliable, Ruggeri -Jensen -Azar & Associates is not <br />responsible for its accuracy, nor for errors or <br />omissions 'ch may have been incorporated into <br />these doliahmts as a result. <br />_ 44828 -3/31/02 <br />Joseph Azar RCE No. / Exp. Data <br />ro <br />m <br />L0 <br />M <br />U O <br />M <br />zO <br />0 <br />ZN <br />Z N <br />dN <br />In, <br />WLo <br />N <br />N a° <br />" X <br />4-4 � < <br />� <br />o <br />o <br />0 <br />5 2 <br />iA Lu <br />>'4 <br />N N <br />� N <br />�< <br />Z N <br />06 W <br />O uj <br />A. ohm Lo zo <br />4J C N (od <br />C0 Y <br />Q <br />W Q <br />M <br />Q a. <br />O <br />aN <br />LL <br />:3 <br />WQ <br />1 Z <br />V <br />' <br />ZW <br />� <br />WZ <br />> <br />.j <br />a. <br />a <br />Z= <br />WZ <br />O <br />>Ix <br />O <br />O W <br />SaQ <br />Q <br />c a, <br />04) <br />V) <br />Z <br />O <br />J <br />6 <br />0 <br />Z <br />Y <br />O <br />fit; wh qty <br />�S <br />m <br />a <br />0 <br />SHEET NO. <br />2 <br />OF 26 SHEETS <br />JOB NO. <br />981007 <br />