Laserfiche WebLink
STRIPING NOTES: <br />ALL TRAFFIC SIGNS AND MARKINGS SHALL CONFORM TO THE "MANUAL ON UNIFORM <br />TRAFFIC CONTROL DEVICES (MUTCD), MUTCD CALIFORNIA SUPPLEMENT, CALTRANS <br />STANDARDS AND SAN JOAQUIN COUNTY STANDARDS" AND AS SHOWN ON THE PLANS. <br />2. THE CONTRACTOR SHALL CONTACT SAN JOAQUIN COUNTY TRAFFIC MAINTENANCE <br />DIVISION PRIOR TO STRIPING AND SIGNING OF THEIR PROJECT FOR A PRE -JOB MEETING. <br />3. REMOVE ALL EXISTING PAVEMENT MARKINGS IN CONFLICT WITH THIS PROJECT. <br />4. ALL PAVEMENT MARKING REMOVAL SHALL BE DONE BY THE CONTRACTOR USING THE <br />HYDROBLASTING METHOD. <br />5. ALL STRIPING FOR STAGE CONSTRUCTION (INSTALLATION/REMOVAL) SHALL BE THE <br />CONTRACTOR'S RESPONSIBILITY AND DONE AT NO COST TO THE DEVELOPER OR <br />ENGINEER. <br />6. ALL CAT -TRACKING OF PAVEMENT DELINEATION SHALL BE APPROVED BY S.J. <br />COUNTY TRAFFIC ENGINEERING DIVISION PRIOR TO FINAL APPLICATION OF PAINT AND <br />MARKINGS. <br />SIGNAGE NOTES: <br />1. ALL TRAFFIC DELINEATIONS (SIGNS, STRIPING AND RAISED PAVEMENT MARKERS) <br />SHALL BE RESTORED TO THEIR ORIGINAL CONDITION UPON COMPLETION OF THE WORK. <br />2. CONTRACTOR SHALL VERIFY ALL STREET NAMES WITH SAN JOAQUIN COUNTY <br />COMMUNITY DEVELOPMENT DEPARTMENT (468-0816) BEFORE ORDERING STREET SIGNS. <br />3. CONTRACTOR SHALL INSTALL A BLUE REFLECTOR 12 -INCHES FROM CENTERLINE ON <br />FIRE HYDRANT SIDE AT ALL FIRE HYDRANT LOCATIONS PER MUTCD, CALIFORNIA <br />SUPPLEMENT SECTION 38.11 AND FIGURE 3B-102. <br />4. ALL STREET SIGNS SHALL BE VISIBLE TO TRAFFIC FROM ALL DIRECTIONS. <br />STREET LIGHTING NOTES: <br />1. ALL STREET LIGHTS SHALL CONFORM TO SAN JOAQUIN COUNTY <br />SPECIFICATIONS. <br />2. SEE SAN JOAQUIN COUNTY DRAWING NUMBERS R-32, R-33, & R-34. <br />3. UNDERGROUND UTILITY TRENCHES SHALL BE PER SAN JOAQUIN COUNTY <br />DRAWING NO. R-29. <br />4. ALL STREET LIGHTS SHALL BE TYPE HPS LU100 OR TYPE HPS LU150 AS <br />NOTED. <br />INDEX: <br />�-- <br />10OW <br />HPS <br />ELECTROLIER <br />�( <br />150W <br />HPS <br />ELECTROLIER <br />0 POWER SOURCE <br />SSL— STREET LIGHT CONDUIT <br />0 SURVEY MONUMENT FRAME & COVER <br />■ BLUE REFLECTIVE MARKER <br />(SEE SIGNAGE NOTE 3 ABOVE) <br />800-227-2600 <br />48 HOURS PR/OR TO WORK OPERA)10N. <br />SCALE: ■ 1 "=50' <br />QRpFES�N,,RY C. q� <br />z <br />NO. 48717 m <br />oc E) PIRES. 9-30-2W8 <br />l_" v I� <br />lSOF C A\-\ <br />UNAUTHORIZED CHANGES AND USES: <br />THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR, OR <br />LIABLE FOR, UNAUTHORIZED CHANGES TO OR USES OF THESE PLANS. ALL <br />CHANGES TO THE PLANS MUST BE IN WRITING AND MUST BE APPROVED BY <br />THE PREPARER OF THESE PLANS. <br />e <br />z <br />n <br />Q <br />0 <br />PLEASE NOTE: <br />ELECTROLIER POWER SOURCE AND CONDUIT LOCATION <br />IS SHOWN ON SHEET 15 BY PACIFIC, GAS AND <br />ELECTRIC. <br />REVISIONS WONG ENGINEERS, INC. <br />NO. DESCRIPTION DATE BYIm <br />PLANNING ENGINEERING SURVEYING <br />4578 FEATHER RIVER DRIVE, SUITE A <br />STOCKTON, CALIFORNIA (209)476-0011 <br />(�- / DATE 07/13/07 R.C.E. 48717 <br />JOB N0: <br />3553 <br />DATE: <br />JULY 2007 <br />SCALE: <br />1"=50' <br />DRAW <br />EMW/AA/JK <br />DESIGN: <br />WE <br />CHECKED: <br />ZCW <br />LAS PALMAS ESTATES <br />SIGNING, STRIPING & <br />ELECTROLIER PLAN <br />SAN JOAQUIN COUNTY,I SHEET <br />CALIFORNIA <br />7 <br />OF FIFTEEN <br />FILE <br />