H <br />HA <br />C <br />D <br />E <br />F <br />G H <br />COUNTYAPPROVAL <br />REVISION DESCRIPTION <br />APPROVED BY DATE <br />i <br />FIELD <br />PLC PANEL <br />PLC PANEL <br />FIELD <br />FROM <br />24VDC <br />POWER <br />SUPPLY <br />1762—OF4 <br />1762-11`4 <br />EXPANSION AO <br />[ <br />MODULE <br />EXPANSION <br />AI MODULE <br />YSI <br />+ — <br />Al <br />OUTPUT <br />0 (+) <br />— — — — Al <br />VFD SPEED <br />— — <br />A2 <br />IN 0 <br />(+) <br />CHANNEL 0 <br />301 <br />INPUT <br />0 (—) <br />— — — — A2 VFD SPEED <br />4-20nnA <br />CHANNEL 0 <br />G <br />G <br />IN 0(—) <br />YSC 301 <br />YSI 301 <br />G <br />+ — <br />A3 <br />1 (+) <br />— — — — A3 <br />CHEMICAL PUMP <br />YSI <br />OUTPUT <br />SPEED <br />321 <br />— _ <br />A4 <br />IN 1 <br />(+) <br />INPUT <br />CHANNEL 1 <br />1 (—) <br />— — — — A4 CHEMICAL PACING <br />4-20nnA <br />CHANNEL 1 <br />G <br />G <br />IN 1 <br />(—) <br />YSC 321 <br />O6 <br />120 VAC <br />_ <br />= <br />G <br />FROM XX <br />YSI 321 <br />I <br />3 <br />+ — <br />A5 <br />2 (+) <br />® <br />BY PASS <br />FE <br />+ <br />FIT <br />OUTPUT <br />SPARE <br />FLOW <br />371 <br />_ _ <br />371 <br />— <br />A6 <br />IN 2 <br />(+) <br />INPUT <br />CHANNEL 2 <br />2 (—) <br />G <br />G <br />4-20ni <br />CHANNEL 2 <br />IN 2(—) <br />120 VAC <br />FROM XX <br />YFI 371 <br />+ <br />A7 <br />3 (+) <br />® <br />EXCHANGER <br />FE <br />+ + <br />FIT <br />OUTPUT <br />SPARE <br />FLOW <br />372 <br />372 <br />_ <br />T <br />A8 <br />IN 3 <br />(+) <br />INPUT <br />CHANNEL 3 <br />3 (—) <br />G <br />G <br />4-20mA <br />CHANNEL 3 <br />IN 3(—) <br />YFI 372 <br />COM <br />® COM <br />COM <br />® COM <br />2 <br />NOTES THIS SHEET <br />O PROCESS VALUES WILL <br />BE PROVIDED <br />LATER; <br />TYPICAL FOR ALL. <br />NOTES: <br />Oj THIS DRAWING SHOWS AN EXAMPLE OF THE FORMAT, LEVEL OF DETAIL & <br />SPECIFIC REQUIREMENTS TO BE PROVIDED. ACTUAL DWG SHALL BE <br />DESIGNED BY SUPPLIER. <br />SCALE BAR IS ONE INCHDATE <br />AT FULL SCALE DESIGNED MB <br />JULY 2007 <br />NO SCALE <br />O IF NOT E 1~ DRAWN BD <br />HIS SHEET <br />SCA ETACCORDINGLY FILE CHECKED WPC <br />FLYJ07-007 <br />ECOLOGIC <br />Engineering <br />Rocklin, California <br />FLYING J INC. <br />333 WEST CENTER STREET <br />NORTH SALT LAKE, UT 84054 <br />FLYING J-LODI <br />CSA 31 WELL NUMBER 3 NITRATE <br />TREATMENT SYSTEM SITE IMPROVEMENTS <br />. ,.nv r er r,n! re <br />n� j ��� J� .•,Mlf.r t <br />� Should Verify <br />All i; dam!1 ,ficy 7',n Si?e Of Work <br />EXAMPLE MLC ANALOG 1/0 <br />M <br />*�ExpiCOT9,/30/07\ <br />rFfo <br />,4\QPOF fi <br />RECORD DRAWING <br />These record drawings have been prepared <br />based on information provided by others. <br />The Engineer has not verified the accuracy <br />of such information and shall not be resp— <br />onsible for any errors or omissions which <br />may be incorporated herein as a result. <br />DRAWING NUMBER I SHEET NUMBER <br />E17 21 of 22 <br />