My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU-4225
PublicWorks
>
VAULT MAPS
>
Subdivision - SU (GIS FILES)
>
SU-4177-4289
>
SU-4225
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/15/2024 12:07:43 PM
Creation date
10/15/2024 12:07:41 PM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
Page 1 of 1
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
A ♦ R ♦ C ♦ n ♦ F ♦ F ♦ G ♦ H <br />5 <br />4 <br />t <br />► <br />VA <br />COUNTY APPROVAL <br />REVISION DESCRIPTION <br />APPROVED BY DATE <br />PRESSURE SWITCH OR <br />PRESSURE GAUGE <br />WITH SNUBBER <br />DIAPHRAGM SEAL WITH <br />TEE W/ PLUG <br />RECORD DRAWING <br />CONNECTION FOR <br />OIL FILL <br />STAINLESS STEEL BOLTS <br />COMBINATION AIR VACUUM <br />BACKFLUSH <br />These record drawings have been prepared <br />1/4- STAINLESS <br />AND STAINLESS STEEL <br />DIAPHRAGM AND LOWER <br />AND AIR RELEASE VALVE _ <br />CONNECTION <br />based on information provided b others. <br />P y <br />STEEL BALL VALVE <br />HOUSING, AMETEK U.S. <br />SEE NOTE 2 <br />() <br />SCH 80 GALVANIZED STEEL <br />The Engineer has not verified the accuracy <br />GAUGE, TYPE SG., <br />NIPPELS TO MATCH AV&ARV <br />of such information and shall not be resp— <br />for or omissions which <br />1 „ CAST IRON <br />ASHCROFT, TYPE 101, <br />ECCENTRIC PLUG VALVE <br />CONNECTION <br />PVC x TUBE <br />onsible any errors <br />may be incorporated herein as a result. <br />o <br />ECCENTRIC PLUG <br />OR EQUAL <br />WITH SCREWED ENDS <br />BUSH IF <br />ADAPTOR <br />VALVE <br />1" SCH. 80 <br />PER SPECIFICATIONS <br />4"-150LB BLIND FLANGE. <br />REQD <br />SST NIPPLES <br />(SEE NOTE 1) t z <br />DRILL & TAP TO MATCH <br />i 1/4"xt" <br />AV & ARV INLET. <br />STUFFING BOX OR SEAL WALLACE <br />SST BUSHING <br />(SEE NOTE 1) <br />& TIERNAN, CAPITOL CONTROLS <br />SAFETY CHAIN <br />3/8" PE TUBING <br />1/2" SCHEDULE 40 <br />ECOMETRICS, SAF—T—FLO OR <br />1 1/4" 3000 LB. FORGED <br />3/16 TYP <br />GALVANIZED STEEL PIPE. <br />EQUAL BRONZE CORPORATION _ <br />2" <br />PVC CONDUIT <br />STEEL HALF COUPLING, L J <br />4"-150LB FLANGED OUTLET. <br />ROUTE TO NEAREST DRAIN <br />STOP <br />_ __ <br />WELD TO PIPE OR 1 1/4" <br />_ <br />SEE NOTE 1 — <br />AND SUPPORT AS <br />MALE <br />ADAPTOR (PVC) <br />TAPPED CONNECTION <br />2" & SMALLER OUTLET MAY i <br />REQUIRED <br />O <br />FLANGE FUSION <br />EPDXY <br />WHERE CAST IRON OR <br />HAVE HALF COUPLING INSTEAD <br />COATED SINGLE TAPPING <br />DUCTILE IRON <br />OF FLANGED OUTLET. <br />SADDLE <br />o = <br />U) <br />a <br />AIR GAP LARGER <br />1/2 PIPE OD <br />/ <br />COAT WITH HIGH <br />a L` <br />OF TWO PIPE <br />DIAMETERS OR 2" <br />PVC TIBALL <br />Q(PASSES <br />SOIDS EPDXY <br />w/ CHECK <br />FOR PIPE LINING <br />THROUGH CORP <br />STOP) <br />& COATING SEE <br />SPECIFICATIONS DRAIN <br />304 SST BIRD SCREEN <br />NOTES: <br />1606 MESH W/0.041 <br />1. SEE PRESSURE GAUGE SCHEDULE <br />FOR <br />WIRE DIAMETER <br />PIPE OD <br />LOCATION OF PRESSURE GAUGES. <br />VARIES SEE <br />PLANS <br />2. SEE ELECTRICAL DRAWINGS AND <br />SPECIFICATIONS <br />FOR LOCATION OF PRESSURE SWITCHES. <br />NOTES: <br />t. FLANGED OUTLET AND ECCENTRIC PLUG VALVE SHOULD BE SUITABLE FOR <br />DETAIL <br />150 PSI PRESSURE MINIMUM. INCREASE PRESSURE <br />RATING AS REQ'D TO <br />g <br />MATCH PIPING SYSTEM TEST PRESSURE. <br />NOTES: <br />LIQUID SERVICE <br />2. VALVE SIZE PER SPECIFICATIONS OR AS INDICATED <br />ON DRAWINGS. <br />1. 3/8" PE TUBING IN 2" PVC <br />CONDUIT <br />TO WITHIN 12" OF INJECTION QUILL <br />PRESSURE GAUGE OR PRESSURE <br />SWITCH <br />AIR -VACUUM AND AIR -RELEASE VALVE <br />WITH DIAPHRAGM SEAL <br />M103 <br />ASSEMBLY 3" AND SMALLER <br />CHLORINE INJECTION <br />M7, 2 <br />SCALE: NONE TYP <br />SCALE: NONE qT1O <br />SCALE: NONE TYP <br />I � <br />I I <br />I I <br />I 1 <br />I I <br />y <br />I <br />F <br />II <br />I r ----I <br />I � I <br />I � I <br />I � 1 <br />TAPPING SADDLE <br />PLAN VIEW <br />INSTALL NEW CORP STOP <br />SEE NOTE 1 <br />10" W <br />PE CL TUBING (E) <br />r <br />I <br />I <br />� <br />I <br />I <br />I <br />EXISTING VAULT <br />I <br />I <br />---------- <br />c <br />�— 2" PVC CONDUIT (E) <br />Q�pF ESS/ON <br />CLOSE CORP STOP AT <br />�Z Co <br />NOT <br />EXISTING INJECTION POINT1. <br />VC EXTENSION TO BE <br />= Exp.12-31-07 l <br />SLIP JOINT WITHOUT <br />ADHESIVE ABOVE GRADE. <br />No. C 59437 <br />CUT VAULT COVER TO <br />ALLOW OPENING AND <br />CLOSIINDAMAGE <br />PVCGC NDUITWITHOUT <br />DO NOT <br />/B [� <br />RECORD n <br />+ �d t I �!Q <br />�fgfF CIV , <br />of r" KV <br />CONNECT PVC TO CORP <br />Corrections By %moi' z� �" =' <br />STOP. <br />No Cha -Ines Ey <br />CHLORINE INJECTION <br />Date <br />CONSTRUCTION DETAIL <br />Any Person Using This Craving Should Verify <br />M712 <br />All information By inspecting The Site Of Work <br />NOT TO SCALE <br />B <br />SCALE` <br />BARTS'ONE INCH <br />AT FULL SCALE <br />DATEDRAWING <br />DESIGNED NTC <br />n <br />LOG IC <br />FLYING J <br />NUMBER <br />SHEET NUMBER <br />" <br />JULY 2007 <br />VO <br />FLYING <br />J INC. <br />-LOOT <br />AS NOTED <br />o �� 1 <br />IF NOT ONE INCH <br />DRAWN BD <br />333 WEST <br />CENTER STREET <br />CSA 31 WELL NUMBER 3 NITRATE <br />TYPICAL <br />MECHANICAL DETAILS II <br />M2 <br />FILE <br />Engineering <br />SCAON LE THIS SHEET <br />FLYJ07-007 <br />CHECKED MAG <br />Rocklin, California <br />NORTH SALT <br />LAKE, UT 84054 <br />TREATMENT SYSTEM SITE IMPROVEMENTS <br />10 OF 22 <br />5 <br />4 <br />t <br />► <br />VA <br />
The URL can be used to link to this page
Your browser does not support the video tag.