My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU-4227
PublicWorks
>
VAULT MAPS
>
Subdivision - SU (GIS FILES)
>
SU-4177-4289
>
SU-4227
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/15/2024 12:07:50 PM
Creation date
10/15/2024 12:07:48 PM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
Page 1 of 1
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
E4O <br />b ♦ L <br />#3 HOOPS (TYP OF 1) <br />3/4" AB W/15" B <br />MIN EMBED — 18"0 WELL CASING <br />REINSTALL EXISTING <br />PUMP MOUNTING <br />PLATE <br />4" GRAVEL <br />FILL TUBE <br />A <br />3" CASING VENT ---- <br />SCALE: 1/2"=1'-0" <br />Q <br />u <br />LOCATE AND REPAIR <br />4" GRAVEL FILL <br />TUBE W/WATER TIGHT <br />WELDS <br />EG <br />EXISTING 4" GRAVEL <br />FILL TUBE <br />WELL REPAIR NOTES: <br />1. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE MOST STRINGENT REQUIREMENTS OF THE SAN JOAQUIN <br />COUNTY WELL STANDARDS, THE CALIFORNIA WELL STANDARDS, AND AWWA A100. ALL APPLICABLE WELL WORK SHALL <br />BE PERFORMED UNDER PERMIT FROM THE SAN JOAQUIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT. <br />2. CONTRACTOR SHALL REMOVE AND WASTE EXISTING CONCRETE WELL PEDESTAL AND SHALL EXCAVATE AROUND <br />EXISTING 30—IN DIAMETER CONDUCTOR CASING TO ENCOUNTER COMPETENT ANNULAR SEAL MATERIAL AS DETERMINED <br />BY THE ENGINEER. EXISTING COMPETENT ANNULAR SEAL SHALL BE SCARIFIED PRIOR TO PLACEMENT OF NEW <br />CONCRETE PEDESTAL. <br />3. WELL CASING, GRAVEL FILL TUBE, AND SOUNDING TUBE SHALL BE VISUALLY INSPECTED BY THE CONTRACTOR AND <br />ALL VISIBLE DEFECTS REPAIRED. EXISTING WELDS SHALL BE REPAIRED TO ACHIEVE A WATER TIGHT SEAL. <br />4. NEW CONCRETE PEDESTAL SHALL BE POURED IN PLACE UPON EXPOSED COMPETENT ANNULAR SEAL MATERIAL IN <br />ONE PLACEMENT. <br />5. EXISTING PUMPING EQUIPMENT SHALL BE CHLORINATED PRIOR TO INSTALLATION ACCORDING TO AWWA C654-03. <br />EXISTING AND NEW EQUIPMENT SHALL BE INSTALLED ACCORDING TO THESE DRAWINGS AND THE CONTRACT <br />DOCUMENTS INCLUDING INSTALLATION OF HIGH PRESSURE SWITCH AND PRE—LUBE WATER SOLENOID VALVE, AS SHOWN <br />ON E14. <br />6. AFTER INSTALLATION OF ALL PERMANENT EQUIPMENT IN THE WELL, THE WELL SHALL BE CHLORINATED ACCORDING <br />TO SECTION 4.5 OF AWWA C954-03 EXCEPT THAT A MINIMUM CHLORINE DOSE OF 100 MG/L SHALL BE ACHIEVED <br />AND SODIUM HYPOCHLORITE OR PRE—MIXED GRANULAR CALCIUM HYPOCHLORITE SHALL BE USED. CHLORINATED <br />WATER SHALL BE DE—CHLORINATED AND DISCHARGED TO THE SAN JOAQUIN COUNTY CSA 31 STORM DRAIN SYSTEM. <br />CONTRACTOR SHALL PUMP THE WELL UNTIL A TOTAL RESIDUAL CHLORINE CONCENTRATION OF 0.05 MG/L OR LESS IS <br />ACHIEVED. CONTRACTOR SHALL PROVIDE ALL NECESSARY MANPOWER, MATERIALS AND EQUIPMENT TO CHLORINATE, <br />DECHLORINATE, AND PURGE WELL INCLUDING BUT NOT LIMITED TO CHEMICALS, PIPING, VALVES, AND FITTINGS. <br />7. RAISE PUMP TO DISCHARGE AT EXISTING ELEVATION OF BAG FILTER INFLUENT PIPING. <br />8. INSTALL ELECTRICAL PER DRAWING E14 INCLUDING HIGH PRESSURE CUT—OFF SWITCH ON DISCHARGE HEAD AND <br />SOLENOID VALVE AND ON EXISTING PRE—LUBE SUPPLY PIPE. <br />SECTION <br />SCALE: 1/2"=1'-0" <br />E <br />42"BORING <br />18"0 WELL CASING <br />30"OCONDUCTOR CASING <br />A <br />HIGH PRESSURE <br />LOCKOUT SWITCH <br />CONNECT ON EXISTING <br />h" PORT ON DISCHARGE <br />HEAD <br />PROVIDE RESTRAINING <br />THROUGH BOLTS SIMILAR <br />TO DETAIL M490. COUPLING <br />GLAND SHALL NOT BE <br />RESTRAINED <br />\ �X10" FLANGE <br />EXISTING WELL <br />DISCHARGE <br />HEAD <br />HIGH PRESSURE SWITCH DETAIL <br />SCALE:NTS <br />RECORD DRAWING <br />These record drawings have been prepared <br />based on information provided by others. <br />The Engineer has not verified the accuracy <br />of such information and shall not be resp— <br />onsible for any errors or omissions which <br />may be incorporated herein as a result. <br />CUT EXISTING WELL CASING <br />BELOW EXISTING SOUNDING <br />TUBE, INSTALL 18" CASING TO <br />%" ABOVE PEDESTAL PLATE W/ <br />18"0 x 03125" COPPER BEARING <br />STEEL <br />EG <br />W <br />, ," <br />G A H <br />COUNTY APPROVAL <br />REVISION DESCRIPTION APPROVED BY DATE <br />NEW 3"CASING VENT W/16 <br />MESH SCREEN CAP CONNECT <br />TO EXISTING SOUNDING TUBE <br />RELOCATE 3"0 <br />SOUNDING TUBE > <br />#4 Q 8" OC EW � <br />F <br />C <br />LOCATE EXISTING 30"0 1 <br />CONDUCTOR CASING, CUT It <br />STRAIGHT AND EXTEND TO 12"t <br />fff��� ABOVE THE LAND SURFACE. <br />4000 PSI CONC I FILL ANNULAR SPACE <br />C4 WITH CEMENT GROUT. <br />#4 VERTICAL BARS <br />(TYP OF 4) —LOCATE COMPETENT ANNULAR <br />EXISTING 42"BORING / I SEAL MATERIAL, SCARIFY AND <br />POUR NEW PUMP PEDESTAL <br />EXIST INNER 30"0 CONDUCTOR CASING <br />ANNULAR SEAL <br />—18"0 WELL CASING <br />SECTION r <br />SCALE: 1 /2"= 1'-0" <br />RECORD,PRA CI N G <br />Correc` ons�� <br />No Cha. g:; Feu <br />Dal <br />Any Person Using This Drawing Should Verity <br />All information By inspecting The Site Of Work <br />Ezp.12-31-07 <br />No. C 59437 <br />SCALE BAR IS ONE INCH DATE <br />AT FULL SCALE DESIGNED NTC DRAWING NUMBER SHEET NUMBER <br />Q��, JULY 2007 E :L I FLYING J INC. FLYING WELL HEAD REPAIR DETAILS <br />AS SHOWN IF NOT ONE INCH DRAWN WEG 333 WEST CENTER STREET CSA 31 WELL NUMBER 3 NITRATE <br />SCA E THIS SHEET ACCORDINGLY FILE CHECKED JOB Engineering NORTH SALT LAKE, UT 84054 PLAN AND SECTIONS C5 OF <br />FLYJ07-007 Rocklin, California TREATMENT SYSTEM SITE IMPROVEMENTS 8 22 <br />I` <br />a <br />1� <br />IL <br />11 <br />3" <br />C <br />q <br />81-01, <br />SCALE: 1/2"=1'-0" <br />Q <br />u <br />LOCATE AND REPAIR <br />4" GRAVEL FILL <br />TUBE W/WATER TIGHT <br />WELDS <br />EG <br />EXISTING 4" GRAVEL <br />FILL TUBE <br />WELL REPAIR NOTES: <br />1. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE MOST STRINGENT REQUIREMENTS OF THE SAN JOAQUIN <br />COUNTY WELL STANDARDS, THE CALIFORNIA WELL STANDARDS, AND AWWA A100. ALL APPLICABLE WELL WORK SHALL <br />BE PERFORMED UNDER PERMIT FROM THE SAN JOAQUIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT. <br />2. CONTRACTOR SHALL REMOVE AND WASTE EXISTING CONCRETE WELL PEDESTAL AND SHALL EXCAVATE AROUND <br />EXISTING 30—IN DIAMETER CONDUCTOR CASING TO ENCOUNTER COMPETENT ANNULAR SEAL MATERIAL AS DETERMINED <br />BY THE ENGINEER. EXISTING COMPETENT ANNULAR SEAL SHALL BE SCARIFIED PRIOR TO PLACEMENT OF NEW <br />CONCRETE PEDESTAL. <br />3. WELL CASING, GRAVEL FILL TUBE, AND SOUNDING TUBE SHALL BE VISUALLY INSPECTED BY THE CONTRACTOR AND <br />ALL VISIBLE DEFECTS REPAIRED. EXISTING WELDS SHALL BE REPAIRED TO ACHIEVE A WATER TIGHT SEAL. <br />4. NEW CONCRETE PEDESTAL SHALL BE POURED IN PLACE UPON EXPOSED COMPETENT ANNULAR SEAL MATERIAL IN <br />ONE PLACEMENT. <br />5. EXISTING PUMPING EQUIPMENT SHALL BE CHLORINATED PRIOR TO INSTALLATION ACCORDING TO AWWA C654-03. <br />EXISTING AND NEW EQUIPMENT SHALL BE INSTALLED ACCORDING TO THESE DRAWINGS AND THE CONTRACT <br />DOCUMENTS INCLUDING INSTALLATION OF HIGH PRESSURE SWITCH AND PRE—LUBE WATER SOLENOID VALVE, AS SHOWN <br />ON E14. <br />6. AFTER INSTALLATION OF ALL PERMANENT EQUIPMENT IN THE WELL, THE WELL SHALL BE CHLORINATED ACCORDING <br />TO SECTION 4.5 OF AWWA C954-03 EXCEPT THAT A MINIMUM CHLORINE DOSE OF 100 MG/L SHALL BE ACHIEVED <br />AND SODIUM HYPOCHLORITE OR PRE—MIXED GRANULAR CALCIUM HYPOCHLORITE SHALL BE USED. CHLORINATED <br />WATER SHALL BE DE—CHLORINATED AND DISCHARGED TO THE SAN JOAQUIN COUNTY CSA 31 STORM DRAIN SYSTEM. <br />CONTRACTOR SHALL PUMP THE WELL UNTIL A TOTAL RESIDUAL CHLORINE CONCENTRATION OF 0.05 MG/L OR LESS IS <br />ACHIEVED. CONTRACTOR SHALL PROVIDE ALL NECESSARY MANPOWER, MATERIALS AND EQUIPMENT TO CHLORINATE, <br />DECHLORINATE, AND PURGE WELL INCLUDING BUT NOT LIMITED TO CHEMICALS, PIPING, VALVES, AND FITTINGS. <br />7. RAISE PUMP TO DISCHARGE AT EXISTING ELEVATION OF BAG FILTER INFLUENT PIPING. <br />8. INSTALL ELECTRICAL PER DRAWING E14 INCLUDING HIGH PRESSURE CUT—OFF SWITCH ON DISCHARGE HEAD AND <br />SOLENOID VALVE AND ON EXISTING PRE—LUBE SUPPLY PIPE. <br />SECTION <br />SCALE: 1/2"=1'-0" <br />E <br />42"BORING <br />18"0 WELL CASING <br />30"OCONDUCTOR CASING <br />A <br />HIGH PRESSURE <br />LOCKOUT SWITCH <br />CONNECT ON EXISTING <br />h" PORT ON DISCHARGE <br />HEAD <br />PROVIDE RESTRAINING <br />THROUGH BOLTS SIMILAR <br />TO DETAIL M490. COUPLING <br />GLAND SHALL NOT BE <br />RESTRAINED <br />\ �X10" FLANGE <br />EXISTING WELL <br />DISCHARGE <br />HEAD <br />HIGH PRESSURE SWITCH DETAIL <br />SCALE:NTS <br />RECORD DRAWING <br />These record drawings have been prepared <br />based on information provided by others. <br />The Engineer has not verified the accuracy <br />of such information and shall not be resp— <br />onsible for any errors or omissions which <br />may be incorporated herein as a result. <br />CUT EXISTING WELL CASING <br />BELOW EXISTING SOUNDING <br />TUBE, INSTALL 18" CASING TO <br />%" ABOVE PEDESTAL PLATE W/ <br />18"0 x 03125" COPPER BEARING <br />STEEL <br />EG <br />W <br />, ," <br />G A H <br />COUNTY APPROVAL <br />REVISION DESCRIPTION APPROVED BY DATE <br />NEW 3"CASING VENT W/16 <br />MESH SCREEN CAP CONNECT <br />TO EXISTING SOUNDING TUBE <br />RELOCATE 3"0 <br />SOUNDING TUBE > <br />#4 Q 8" OC EW � <br />F <br />C <br />LOCATE EXISTING 30"0 1 <br />CONDUCTOR CASING, CUT It <br />STRAIGHT AND EXTEND TO 12"t <br />fff��� ABOVE THE LAND SURFACE. <br />4000 PSI CONC I FILL ANNULAR SPACE <br />C4 WITH CEMENT GROUT. <br />#4 VERTICAL BARS <br />(TYP OF 4) —LOCATE COMPETENT ANNULAR <br />EXISTING 42"BORING / I SEAL MATERIAL, SCARIFY AND <br />POUR NEW PUMP PEDESTAL <br />EXIST INNER 30"0 CONDUCTOR CASING <br />ANNULAR SEAL <br />—18"0 WELL CASING <br />SECTION r <br />SCALE: 1 /2"= 1'-0" <br />RECORD,PRA CI N G <br />Correc` ons�� <br />No Cha. g:; Feu <br />Dal <br />Any Person Using This Drawing Should Verity <br />All information By inspecting The Site Of Work <br />Ezp.12-31-07 <br />No. C 59437 <br />SCALE BAR IS ONE INCH DATE <br />AT FULL SCALE DESIGNED NTC DRAWING NUMBER SHEET NUMBER <br />Q��, JULY 2007 E :L I FLYING J INC. FLYING WELL HEAD REPAIR DETAILS <br />AS SHOWN IF NOT ONE INCH DRAWN WEG 333 WEST CENTER STREET CSA 31 WELL NUMBER 3 NITRATE <br />SCA E THIS SHEET ACCORDINGLY FILE CHECKED JOB Engineering NORTH SALT LAKE, UT 84054 PLAN AND SECTIONS C5 OF <br />FLYJ07-007 Rocklin, California TREATMENT SYSTEM SITE IMPROVEMENTS 8 22 <br />I` <br />a <br />1� <br />IL <br />11 <br />
The URL can be used to link to this page
Your browser does not support the video tag.