Laserfiche WebLink
iu# <br />0 <br />VA <br />I <br />0 <br />M <br />3" 2 <br />I B { I D I I F I I H I _ 1 I J I K <br />SYMBOL DESCRIPTION <br />A LIGHTING FIXTURE SYMBOL - TYPE & QUANTITY <br />PANELBOARD <br />O CONTROL PANEL <br />® SWITCHBOARD <br />SYMBOLS LIST <br />SYMBOL DESCRIPTION SYMBOL <br />00 FOURPLEX CONVENIENCE RECEPTACLE <br />OUTLET 20A, 125V <br />:0 DUPLEX CONVENIENCE OUTLET, <br />HALF SWITCHED <br />PLUGMOLD, SINGLE RECEPTACLE OUTLET STRIP <br />M AMMETER 250 DEGREE SCALE 20A, 125V, WALL MOUNTED AT +12" UON O <br />�M VOLT METER 250 DEGREE SCALE �• MOUNT OUTLET OR SWITCH ABOVE <br />COUNTER OR BACKSPLASH <br />© WATT HOUR METER AND SOCKET ST <br />g DUPLEX CONVENIENCE OUTLET, 20A <br />30 20A, RECEPTACLE OUTLET <br />m PHOTOCELL <br />FILE: 0309EO1.DWG - E 1 1 EDIT: 4/12/2007 6:07 AM BY LISINS:'l I PLOT: 4/12/2007 6:15 AM BY JOHN LISINSKI <br />❑H 1 <br />ALARM HORN <br />He <br />PHASE FAILURE RELAY <br />©T <br />ELASPED TIME METER <br />❑•HOA <br />HAND -OFF -AUTO SELECTOR SWITCH <br />❑•HCR <br />HAND -OFF -REMOTE SELECTOR SWITCH <br />ED LOS <br />LOCK -OFF -STOP SELECTOR SWITCH <br />❑p VS <br />VOLT METER SWITCH, 4 POSITION <br />III AS <br />AMMETER POSITION, 4 POSITION <br />[T] 11R ry <br />TRr NSFORMER <br />m <br />CONTROL POWER TRANSFORMER <br />- <br />CURRENT TRANSFORMER <br />® <br />METER & CURRENT TRANSFORMER <br />® <br />SELECTOR SWITCH <br />OL <br />OL <br />TIME DELAY RELAY <br />MANUAL MOTOR STARTERO <br />(DELAY ON DE-ENERGIZATION) <br />—I— <br />TIME DELAY RELAY <br />SAFETY DISCONNECT SWITCH <br />(DELAY ON ENERGIZATION) <br />OLATCHING <br />RELAY <br />OCONTROL <br />RELAY <br />R <br />INDUSTRIAL RELAY (MACHINE TOOL) <br />OLIMIT <br />SWITCH <br />ISR <br />INTRINSICALLY SAFE RELAY <br />IDR <br />INCUCT10N CONTROL RELAY <br />O <br />CEILING LIGHT FIXTURE <br />QI <br />BRACKET LIGHT FIXTURE <br />(Di <br />WARNING LIGHT <br />LOS & AUX CONTACT <br />POLE MOUNTED LIGHT FIXTURE <br />PVC <br />n <br />r--� <br />FLUCRESCENT LIGHT FIXTURE, SEE FIXTURE <br />�� <br />SOI <br />SCHEDULE FOR MOUNTING <br />b <br />FLOOD LIGHT <br />oQv <br />EMERGENCY <br />AMPERE SIZE SHOWN <br />LIGHT PACK <br />® <br />SMOKE DETECTOR <br />$n <br />SINGLE POLE TOGGLE SWITCH, <br />SWITCHING FIXTURES DENOTED <br />$3 <br />THREE WAY TOGGLE SWITCH <br />$T <br />THERMAL MANUAL STARTER, 1 POLE <br />$ 2T <br />THERMAL MANUAL STARTER 2 POLE <br />g DUPLEX CONVENIENCE OUTLET, 20A <br />30 20A, RECEPTACLE OUTLET <br />m PHOTOCELL <br />FILE: 0309EO1.DWG - E 1 1 EDIT: 4/12/2007 6:07 AM BY LISINS:'l I PLOT: 4/12/2007 6:15 AM BY JOHN LISINSKI <br />❑H 1 <br />ALARM HORN <br />CLOSE ON LOW LEVEL <br />EXPOSED BELOW CEILING <br />Q <br />THERMOSTAT <br />----- <br />SV <br />HQ <br />HEATER, ELECTRIC <br />CLOSE LOW PRESSURE <br />NO MARKS = 3/4"C, 2 #12 <br />® Q3 <br />CIRCUIT BREAKER OPERATING <br />HANDLE <br />ST <br />—y- <br />MOTOR, HORSEPOWER SIZE NOTED <br />-f <br />SEAL -OFF FITTING, CROUSE HINDS EYS OR EQ <br />Q <br />GROUND BUS <br />® <br />MO <br />MOTOR STARTER CONTACTOR <br />COIL <br />OL <br />OL <br />NAMEPLATE <br />MANUAL MOTOR STARTERO <br />WIRES CONNECTED <br />—I— <br />❑J <br />SAFETY DISCONNECT SWITCH <br />- NON FUSED <br />PT <br />[DJ <br />SAFETY DISCONNECT SWITCH <br />- FUSED <br />Q <br />SHIELDED, PAIR CABLE <br />SAFETY DISCONNECT SWITCH <br />WITH LOS <br />FM <br />® <br />& AUX CONTACT <br />EXISTING <br />/PEDESTAL <br />Fol <br />SAFETY DISCONNECT SWITCH <br />WITH START BUTTON, <br />FIT <br />UO <br />LOS & AUX CONTACT <br />ELECTRICAL METALLIC TUBING <br />PVC <br />n <br />CIRCUIT BREAKER <br />CATALOG NUMBER OF TYPICAL GAS <br />`ems° <br />POWER <br />INDICATION FUSE HOLDER <br />TIGHT CONDUIT SEAL <br />oQv <br />SA <br />AMPERE SIZE SHOWN <br />(R) <br />EXISTING TO BE REMOVED OR <br />EM <br />EMERGENCY LIGHT BALLAST <br />on <br />FUSE, AMPERE SIZE SHOWN <br />ELAPSED TIME METER <br />MT <br />o'_� <br />p]�.YiT:7fidiP►1 <br />WELDER OUTLET, 30 AMP, 30, 4W, 480V WITH <br />ONE MATCHING CAP. <br />TELEPHONE OUTLET, ROUTE 3/4" CONDUIT WITH <br />PULLROPE TO TELEPHONE TERMINAL CABINET. <br />JUNCTION BOX <br />FIELD CONNECTION TERMINAL BLOCK <br />SPRING WOUND TIMER <br />SOLENOID VALVE <br />CIRCUIT BREAKER SHUNT TRIP <br />CONTACT NORMALLY OPEN <br />CONTACT NORMLLY CLOSED <br />OVERLOAD DEVICE CONTACT <br />OVERLOAD DEVICE HEAT ELEMENT <br />PRESSURE TRANSDUCER <br />PUSHBUTTON <br />FLOW INDICATING METER <br />FLOW INDICATING TOTALIZER <br />LIMIT SWITCH, NORMALLY OPEN <br />LIMIT SWITCH, NORMALLY CLOSED <br />TIME DELAY CONTACT, <br />NORMALLY CLOSED TIME OPEN <br />TIME DELAY CONTACT, <br />NORMALLY OPEN TIME CLOSE <br />TIME DELAY CONTACT, <br />NORMALLY OPEN TIME OPEN <br />TIME DELAY CONTACT, <br />NORMALLY CLOSED TIME CLOSED <br />FLOAT SWITCH <br />CLOSE ON HIGH LEVEL <br />FLOAT SWITCH <br />CONDUIT RUN EXPOSED ON OR IN WALL OR <br />CLOSE ON LOW LEVEL <br />EXPOSED BELOW CEILING <br />----- <br />CONDUIT RUN EXPOSED IN ATTIC AREA <br />----- <br />CONDUIT RUN UNDERFLOOR OR UNDERGROUND <br />-- <br />DENOTES NUMBER OF #12 WIRES. <br />CLOSE LOW PRESSURE <br />NO MARKS = 3/4"C, 2 #12 <br />�- <br />DENOTES WIRE FOR GROUND FAULT <br />PUSH BUTTON, NORMALLY <br />CIRCUIT INTERRUPTER OR GROUND WIRE <br />—y- <br />CIRCUIT RUN DIRECT TO DESTINATION <br />-f <br />SEAL -OFF FITTING, CROUSE HINDS EYS OR EQ <br />Q <br />GROUND BUS <br />® <br />NEUTRAL BUS <br />PH <br />PULL BOX <br />Q <br />NAMEPLATE <br />CPT <br />WIRES CONNECTED <br />—I— <br />PANEL <br />WIRES NOT CONNECTED <br />CONTROL RELAY <br />CONDUIT CROSSING NOT CONNECTED <br />l <br />GROUND <br />CURRENT TRANSFORMER <br />LIGHTNING ARRESTER <br />SHIELDED, PAIR CABLE <br />CONDUIT & WIRE IDENTIFICATION TAG <br />�i <br />SHEET NOTE TAG <br />® <br />TYPICAL MOTOR CONTROL CENTER/ <br />SWITCHBOARD <br />EXISTING <br />/PEDESTAL <br />POTENTIAL TRANSFORMER <br />IDENTIFICATION TAG <br />0, PH <br />PHASE <br />o'_� <br />p]�.YiT:7fidiP►1 <br />WELDER OUTLET, 30 AMP, 30, 4W, 480V WITH <br />ONE MATCHING CAP. <br />TELEPHONE OUTLET, ROUTE 3/4" CONDUIT WITH <br />PULLROPE TO TELEPHONE TERMINAL CABINET. <br />JUNCTION BOX <br />FIELD CONNECTION TERMINAL BLOCK <br />SPRING WOUND TIMER <br />SOLENOID VALVE <br />CIRCUIT BREAKER SHUNT TRIP <br />CONTACT NORMALLY OPEN <br />CONTACT NORMLLY CLOSED <br />OVERLOAD DEVICE CONTACT <br />OVERLOAD DEVICE HEAT ELEMENT <br />PRESSURE TRANSDUCER <br />PUSHBUTTON <br />FLOW INDICATING METER <br />FLOW INDICATING TOTALIZER <br />LIMIT SWITCH, NORMALLY OPEN <br />LIMIT SWITCH, NORMALLY CLOSED <br />TIME DELAY CONTACT, <br />NORMALLY CLOSED TIME OPEN <br />TIME DELAY CONTACT, <br />NORMALLY OPEN TIME CLOSE <br />TIME DELAY CONTACT, <br />NORMALLY OPEN TIME OPEN <br />TIME DELAY CONTACT, <br />NORMALLY CLOSED TIME CLOSED <br />FLOAT SWITCH <br />CLOSE ON HIGH LEVEL <br />FLOAT SWITCH <br />AMPERES <br />CLOSE ON LOW LEVEL <br />NOT IN CONTRACT <br />PRESSURE SWITCH <br />AMPS INTERRUPTING CAPACITY <br />CLOSE HIGH PRESSURE <br />NAMEPLATE <br />PRESSURE SWITCH <br />BARE COPPER <br />CLOSE LOW PRESSURE <br />OVERLOAD DEVICE <br />DISCONNECT SWITCH <br />CONDUIT <br />PUSH BUTTON, NORMALLY <br />OPEN OR <br />MOMENTARILY CLOSED <br />CIRCUIT BREAKER <br />PUSH BUTTON, NORMALLY <br />CLOSED OR <br />MOMENTARILY OPEN <br />CONTROL <br />TEMPERATURE SWITCH, NORMALLY CLOSED <br />OPEN ON HIGH TEMP (CUT <br />OUT) <br />TEMPERATURE SWITCH, NORMALLY OPEN <br />CLOSE ON HIGH TEMP <br />Pte' <br />-a WHITE PILOT LIGHT, PUSH TO TEST <br />GREEN PILOT LIGHT, PUSH TO TEST <br />� RED PILOT LIGHT, PUSH TO TEST <br />WEST YOST <br />k ~-ago <br />0 <br />ASSOCIATES <br />1260 Lake Boulevard <br />Suite 240 <br />Davis, California 95616 <br />(530) 756-5905 <br />REVISIONS Consulting Engineers FAX (530) 756-5991 <br />ABBREVIATIONS <br />A <br />AMPERES <br />N.I.C. <br />NOT IN CONTRACT <br />AIC <br />AMPS INTERRUPTING CAPACITY <br />NP <br />NAMEPLATE <br />BC <br />BARE COPPER <br />OL <br />OVERLOAD DEVICE <br />C <br />CONDUIT <br />PB <br />PULLBOX <br />CB <br />CIRCUIT BREAKER <br />PB -1 <br />PUSHBUTTON 1 <br />CNTL <br />CONTROL <br />PC <br />PROGRAMMABLE CONTROLLER <br />COM <br />COMMUNICATION <br />PL -1 <br />PILOT LIGHT 1 <br />CPT <br />CONTROL POWER TRANSFORMER <br />PNL <br />PANEL <br />CR <br />CONTROL RELAY <br />POT <br />POTENTIOMETER <br />CT <br />CURRENT TRANSFORMER <br />PP, <br />SHIELDED, PAIR CABLE <br />CU <br />COPPER <br />PS <br />PRESSURE SWITCH <br />(E) <br />EXISTING <br />PT <br />POTENTIAL TRANSFORMER <br />EF <br />EXHAUST FAN <br />PTT <br />PUSH TO TEST <br />EMT <br />ELECTRICAL METALLIC TUBING <br />PVC <br />POLYVINYL CHLORIDE <br />EYS <br />CATALOG NUMBER OF TYPICAL GAS <br />PWR <br />POWER <br />TIGHT CONDUIT SEAL <br />(R) <br />EXISTING TO BE REMOVED OR <br />EM <br />EMERGENCY LIGHT BALLAST <br />RELEASED <br />ETM <br />ELAPSED TIME METER <br />MT <br />EMPTY CONDUIT WITH NYLON PULL <br />CORD <br />F <br />FUSE <br />N <br />NEUTRAL <br />(F) <br />FUTURE <br />NA <br />NON AUTOMATIC <br />FS <br />FLOAT SWITCH <br />NL <br />NIGHT LIGHT CONTINUOUSLY ON <br />FVC <br />FULL VOLTAGE CONTACTOR <br />(N) <br />NEW <br />FVNR <br />FULL VOLTAGE NON REVERSING <br />VS <br />VOLTMETER SWITCH <br />FVR <br />FULL ,VOLTAGE REVERSING <br />WP <br />WEATHERPROOF <br />G, GND <br />GROUND <br />XFMR <br />TRANSFORMER <br />GFI <br />GROUND FAULT CIRCUIT INTERRUPTER <br />XP <br />EXPLOSION PROOF <br />HPS <br />HIGH PRESSURE SODIUM <br />UG <br />UNDERGROUND <br />ICP <br />INSTRUMENTATION CONTROL PANEL <br />LON <br />UNLESS OTHERWISE NOTED <br />ISO <br />ISOLATION <br />V <br />VOLTS, VOLTAGE <br />ISR <br />INTRINSICALLY SAFE RELAY <br />VFD <br />VARIABLE FREQUENCY DRIVE <br />INST <br />INSTANTANEOUS <br />VM <br />VOL .METER <br />KV <br />KILOVOLT <br />RSC <br />RIGID STEEL CONDUIT <br />KVA <br />KILOVOLT AMPERES <br />RSC/PVC <br />RIGID STEEL PVC COATED <br />KW <br />KILOWATT <br />RVAT <br />REDUCED VOLTAGE <br />LA <br />LIGHTNING ARRESTER <br />AUTOTRANSFORMER <br />LOS <br />LOCK OFF STOP PUSH BUTTON <br />2SPD <br />TWO SPEED STARTER <br />mA <br />MILLIAMPERES <br />SS -1 <br />SELECTOR SWITCH 1 <br />MCC <br />MOTOR CONTROL CENTER <br />SWBD <br />SWITCHBOARD <br />MCP <br />MOTOR CIRCUIT PROTECTOR <br />TDD,TDE <br />TIME DELAY RELAY <br />MH <br />MANHOLE <br />TM <br />THERMAL MAGNETIC <br />MOD <br />MODULE <br />TVSS <br />TRANSIENT VOLTAGE SURGE <br />SUPPRESSOR <br />MOT <br />MOTOR OVERTEMPERATURE SENSOR <br />TWSP <br />TWISTED SHIELDED PAIR <br />MMS <br />MOTOR MOISTURE SENSOR <br />TWST <br />TWISTED SHIELDED TRIAD <br />MSB <br />MAIN SWITCHBOARD <br />TWP <br />TWISTED PAIR <br />TYP <br />TYPICAL <br />Coniact <br />David J. Arct anrJelo <br />Project <br />7_006-0309 <br />INTERFACE <br />ENGINEERING <br />8950 CAL CENLTR DR , BLiPPE 250, SACRAhIE6TO, CA 9,,826 <br />PIIONE916.288.62co PAX916.288.6250 <br />I <br />BAR IS ONE INCH t=R11111111=31111111 ON ORIGINAL DRAWING <br />IF NOT ONE INCH ON THIS SHEET, ADJUST SCALES ACCORDINGLY <br />County of San Joaquin roe MAGIM <br />010-00-07-18 <br />Flag City Pump Station & Force Main DWNG NIS <br />E1 <br />SHEET NUMM <br />ELECTRICAL 25 of 44 <br />SYMBOLS & ABBREVIATIONS INNI N <br />141 <br />10 <br />E <br />U <br />7 <br />E <br />5 <br />4 <br />3 <br />2 <br />1 <br />