ABBREI/IA TIONS <br />3W <br />3 -WIRE <br />4W <br />4 -WIRE <br />A <br />AMPERE <br />AC <br />ALTERNATING CURRENT <br />AUX <br />AUXILIARY <br />CPT <br />CONTROL POWER TRANSFORMER <br />(IN INDIVIDUAL STARTER CUBICLE) <br />DC <br />DIRECT CURRENT <br />DIA <br />DIAMETER <br />DPDT <br />DOUBLE PULL DOUBLE THROW <br />FS <br />FLOW SWITCH <br />G, EG <br />EQUIPMENT GROUND <br />GFCT <br />GROUND FAULT CURRENT TRANSFORMER <br />GF/ <br />GROUND FAULT INTERRUPTING <br />HP <br />HORSEPOWER <br />HZ <br />HERTZ <br />INST <br />INSTANTANEOUS <br />JB <br />JUNCTION BOX <br />KV <br />KILO (1000) VOLT <br />KV,4 <br />KILO (1000) VOLT AMPERES <br />LS <br />LIMIT SWITCH <br />MCC <br />MOTOR CONTROL CENTER <br />MCP <br />MOTOR CIRCUIT PROTECTOR <br />NO <br />NUMBER, NORMALLY OPEN <br />OCB <br />OIL CIRCUIT BREAKER <br />OL <br />OVERLOAD RELAY <br />P <br />POLE <br />PH, 0 <br />PHASE <br />PL <br />PILOT LIGHT <br />PRESS <br />PRESSURE <br />PRI <br />PRIMARY <br />PS <br />PRESSURE SWITCH <br />PT <br />POTENTIAL TRANSFORMER <br />PVC <br />POLYVINYL CHLORIDE <br />RECT <br />RECTIFIER <br />RCPT <br />RECEPTACLE <br />RTD <br />RESISTANCE TEMPERATURE DETECTOR <br />RTU <br />REMOTE TELEMETRY UNIT <br />RVAT <br />REDUCED VOLTAGE AUTO TRANSFORMER <br />SEC <br />SECONDARY <br />SP <br />SPARE <br />SQ <br />SQUARE <br />SS <br />SELECTOR SWITCH, STAINLESS STEEL <br />SW <br />SWITCH <br />SWBD <br />SWITCHBOARD <br />TSP <br />TWISTED SHIELDED PAIR <br />TST <br />TWISTED SHIELDED TRIAD <br />T -STAT <br />THERMOSTAT <br />TYP <br />TYPICAL <br />UG <br />UNDERGROUND <br />UPT <br />UNSHIELDED TWISTED PAIR <br />V <br />VOLTAGE, VOLTS <br />VS <br />VIBRATION SWITCH <br />WP <br />WEATHERPROOF <br />W <br />WATTS <br />XFMR <br />TRANSFORMER <br />XMTR <br />TRANSMITTER <br />SYMBOLS LEGEND: GENERAL NOTES: <br />CONDUIT RUN UNDERGROUND OR /N CONCRETE OJ JUNCTION BOX <br />1. INSTALLATION SHALL MEET ALL REQUIREMENTS OF THE LATEST EDITION OF THE <br />CONDUIT HOME RUN TO PANEL DP 1, CIRCUIT NO. 1 NATIONAL ELECTRICAL CODE (NEC) AND ALL LOCAL CODES HAVING JURISDICTION. <br />DP -1 SHORT MARKS INDICATE NO. OF POWER CONDUCTORS, ETM ELA 'SED TIME METER 2. AN EQUIPMENT GROUND/NG CONDUCTOR SIZED PER THE NEC SHALL BE PULLED <br />LONG DASH DENOTES NEUTRAL, SHORT DASH DENOTES /N ALL ELECTRICAL CONDUITS (POWER AND CONTROL) WHETHER OR NOT <br />LINE, CURVED UNE DENOTES GROUND CT CURRENT TRANSFORMER, SHOWN ON THE PLANS. <br />RATIO AND NUMBER OF CT'S AS NOTED J. ALL EQUIPMENT SHALL BE NEW, UNUSED, AND U.L. LISTED (WHERE A U.L. <br />EXPOSED CONDUIT I LISTING IS AVAILABLE FOR THAT CLASS OF EQUIPMENT). <br />CONDUIT BENDS TOWARD OBSERVER FU TD DISCONNECT SWITCH 4. ALL EQUIPMENT FURNISHED AND INSTALLED BY THE CONTRACTOR SHALL BE <br />J POLE UNLESS OTHERWISE NOTED GUARANTEED AGAINST DEFECTS /N MATERIALS AND WORKMANSHIP FOR A <br />CONDUIT BENDS AWAY FROM OBSERVER PERIOD OF ONE YEAR FROM THE DATE OF ACCEPTANCE. <br />GROUND GRID WIRE 5. THE DRAW/NGS ARE NOT INTENDED TO SHOW THE EXACT LOCATION OF CONDUIT <br />RUNS AND STUB -UPS. THESE ARE TO BE COORDINATED WITH OTHER TRADES <br />i� FLEX/BLE LIQUID - TIGHT CONDUIT CONNECTION v LJ u " HEATER TO AVOID CONFLICTS AND MAINTAIN REQUIRED CLEARANCES. THE CONTRACTOR <br />v SHALL COORDINATE CONDUIT STUB -UP LOCATIONS BASED UPON APPROVED <br />EQUIPMENT SHOP DRAWINGS. <br />INDICATES CONDUIT NUMBER CR CONT40L RELAY 6. UNLESS SHOWN OTHERWISE, ALL LIGHTING & RECEPTACLE HOMERUNS SHALL BE <br />P1 SEE CABLE AND CONDUIT SCHEDULE 3/4" CONDUIT CONTAINING (AS A MINIMUM) 2#12 AND 1 112 GND. <br />M� MOTOR STARTER CONTACTOR <br />0-0 POLE MOUNTED LIGHT FIXTURE <br />X - LIGHTING SCHEDULE DESIGNATION 51 INS; NTANEOUS AND TIME OVERCURRENT RELAY <br />120V DUPLEX RECEPTACLE, NEMA 51 TIME OVERCURRENT RELAY <br />CONFIGUR4T/ON 5-20. <br />86 LOC' -,`OUT RELAY (HAND RESET) <br />b 100AT MOLDED CASE CIRCUIT BREAKER, 3 POLE UNLESS 59 GR( IND FAULT OVERVOLTAGE RELAY <br />q <br />Inn <br />OTHERWISE NOTED: 100A - TRIP RATING /N AMPERES N <br />AT - AMPERES TRIP <br />AF - AMPERES FRAME <br />n MCP - MOTOR CIRCUIT PROTECTOR EMF_;,GENCY LIGHTING PACK <br />MEDIUM VOLTAGE STARTER <br />T O GROUND ROD <br />v <br />N.O. CONTACT PU& /BUTTON STATION <br />I F— <br />I N.C. CONTACT D D/SC 9NNECT SWITCH <br />0 0 NORMALLY OPEN - TIME DELAY <br />NORMALLY CLOSED - TIME DELAY <br />OL <br />0---0 OVERLOAD RELAY CONTACTS <br />® FUSE <br />0 0 THERMOSTAT OR MOTOR TEMP. SWITCH <br />0 <br />INDUCTION MOTOR, (NUMBER INDICATES HORSEPOWER) <br />L INDICATING LIGHT- <br />OVERLOAD RELAY <br />G -GREEN <br />R -RED <br />® FIELD TERMINATION (DEVICES) <br />EXIFTING EQUIPMENT TO BE REMOVED AND REPLACED UNDER ALTERNATE BID ITEM A' OR <br />5 MEDIUM OR HIGH VOLTAGE DR4WOUT BREAKER <br />Y <br />a FULL VOLTAGE NON -REVERSING STARTER, <br />NEMA SIZE AS INDICATED BY * <br />FLUORESCENT LIGHT FIXTURE <br />X X - LIGHT/NG SCHEDULE DESIGNATION <br />A <br />e e - cyhc a <br />INC. <br />6060 Sunrise Vista, #3450 <br />Citrus Heights, ca 95610 <br />COPYRIGHT© 2005 NORTHSTAR ENGINEERING GROUP, INC <br />W <br />O <br />CLCL <br />a <br />4 <br />in <br />z <br />Z <br />0 <br />Vl <br />W <br />x <br />N <br />z <br />o <br />L <br />a <br />Ld <br />W <br />O <br />0 <br />Z <br />a <br />W z <br />7 � <br />WO <br />J <br />O v <br />z z <br />Q W <br />cl� 0 <br />Ldz <br />W Q <br />J 1 z <br />Q W =D <br />U a o <br />� � z <br />U c� <br />O <br />LLJZO <br />W <br />cz <br />O Q <br />a <br />JOB <br />DATE: 03 08 07 <br />SCALE: <br />DRAWN: K.T. <br />DESIGN: M.B. <br />CHK D. M.B. <br />SHEET <br />NUMBER <br />E1 <br />OF 47 <br />