Laserfiche WebLink
111 <br />LCRS 2B CONTROL <br />PANEL <br />M••. • <br />r - • r : i . <br />GROUNDING <br />BUSHING AND 3 <br />SEALING LOCK NUT <br />OR GROUNDING E09 E07 <br />CONDUIT HUB <br />STRUT CONDUIT <br />SUPPORT <br />CONDUIT <br />STRUT STRAP <br />f" RMC <br />/4 CU STAND <br />U •• <br />I x10' COPPER <br />aJ� caROUND <br />ROUND <br />�`� GROUND ROD DETAIL <br />#10 CU STRAINM (N) <br />• � • �Y�• • • 181 <br />Ra <br />GROUNDING <br />BUSHING <br />PUMP &SENSOR CABLE/ <br />RISER CONNECTION <br />HPDE TAP &THREAD OPTION <br />SCALE: NTS <br />!••1 •��rT i- <br />• • 191 199' <br />O '• PAN! SURGE SS•. <br />,A CLI CD41FKL PX4E GFIC INTERRUPlER <br />LEVEL SE14SOR SJU &PPRESSOR <br />1••• MOUNTED <br />GROUMNG TERMINALS <br />R <br />i I I <br />CONDUIT <br />0000100001 100001 <br />480V <br />_ 480/120V <br />F�Ft <br />1RANSFO <br />120 <br />O <br />0 <br />GFlC OUTLET <br />PUMP &SENSOR CABLE/ <br />RISER CONNECTION <br />SLEEVED NIPPLE OPTION <br />SCALE: N TS <br />I]'t-• I 1 <br />r <br />1 ;" SCHEDULE 80 PVC CONDUIT <br />NOTES: <br />1. ALL DIMENSIONS ARE MINIMUM UNLESS OTHERWISE INDICATED <br />ON THE DRAWINGS. <br />2. REFER TO SPECIFICATIONS FOR TRENCH BACKFILL <br />REQUIREMENTS. <br />3. BACKFILL SAND SHALL BE CLEAN WITH NO CLAY OR ORGANIC <br />MATERIALS. IT SHALL BE 95% DRY—IN--PLACE DENSITY AS PER <br />ASTM D--1557. IT SHALL BE QUAIL HALLOW UTILITY TRENCH <br />SAND OR PECKER ISLAND FILL SAND. <br />3/4x10 FT <br />--- COPPER CLAD <br />GROLM ROD LEVEL PUMP <br />SENSCR BREAKOUT <br />BREAKOUT eox BREAKOUT BOX TO RISER <br />r4-LCRS PANEL GROUNDING s DIRECT BURIED CONDUIT <br />�qg SCALE: NTS SCALE: N TS <br />0 11/13/18 ISSUED FOR NiTIt1UC; SAN SAM JVR JVR <br />-------C--O----- ---- DATE OF ISSUE: 11l13/2018_ _— - ESS/4 DRAWING NO. <br />DESIGNED BY: SAH _ GeomLosic MODULE 213 <br />A S S O C I AT E S CONSTRUCTION DETAILS E09 <br />DRAWN BY: ___ SAM <br />* 6 12l� * 143E Spring Hili Dr, Grass Valley, California 95945 FOOTHILL SANITARY LANDFILL BREAKOUT BOX DETAILS <br />Exp. _. <br />CHECKED BY. __ __ geo-logic.com 530.272.2448 <br />C�yt� � AU 17.1254 <br />REV. NO. DATE DESCRIPTION DRAWN BY DESIGNED BY CHECKED BY APPROVED BY APPROVED BY: __ J'VR <br />rYrddrTer rrrr� <br />This drawing has not been published but rather has been prepared by Geo -Logic Associates, <br />Inc. for use <br />by the client named in the title block, solely in respect of the construction operation, <br />and maintenance of the facility named in the title block. Geo -Logic Associates, Inc. <br />shall not be liable <br />for the use of this drawing on any other facility or for any other purpose. <br />6043ce <br />b-2� <br />