My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU1343-SU1344
PublicWorks
>
VAULT MAPS
>
Subdivision - SU
>
SU1164 - SU1380
>
SU1343-SU1344
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2024 12:06:38 PM
Creation date
12/12/2024 12:05:14 PM
Metadata
Fields
Template:
Subdivision - SU
Subdivision
Water Line Extension in County Service Area No. 12
Sheet #
2
Supplemental fields
Cross Ref
SU1343-SU1344
Date
5/2/1960
Document Relationships
County Service Area No. 12
(Message)
Path:
\VAULT MAPS\*CARD CATALOG*\CO - CQ
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
GENERAL NOTES: <br />I. ALL IMPROVEMENTS SHALL BE CONSTRUCTED IN STRICT ACCORDANCE WITH THE <br />IMPROVEMENT SPECIFICATIONS AND DRAWINGS AND THE APPROVED SET OF PLANS. <br />2. AS BUILT PLANS TO BE FILED WITH THE DEPARTMENT OF PUBLIC WORKS UPON <br />COMPLETING CONSTRUCTION. <br />3. THE CONTRACTOR SHALL BE IN RECEIPT OF APPROVED PLANS PRIOR TO THE <br />BEGINNING OF CONSTRUCTION. <br />4. THE CONTRACTOR SHALL NOTIFY THE COUNTY ENGINEER 24 HOURS IN ADVANCE <br />OF PERFORMING ANY WORK REQUIRED IN THESE PLANS. <br />5. THE CONTRACTOR SHALL CONTACT ALL APPLICABLE UTILITY COMPANIES RE- <br />GARDING THE EXISTENCE AND LOCATION OF FACILITIES IN THE CONSTRUCTION <br />AREA. CALL U.S.A. AT LEAST 48 HOURS PRIOR TO EXCAVATING IN THIS AREA, <br />PHONE 800-642-2444. <br />6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTION OF EXISTING IMPROVE- <br />MENTS AND UTILITIES FROM DAMAGE. ANY DAMAGE TO EXISTING FACILITIES <br />SHALL BE REPAIRED BY CONTRACTOR AT CONTRACTOR `S EXPENSE. <br />7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL EXISTING <br />AND OTHER SURVEY MARKERS DURING CONSTRUCTION. ALL SUCH MARKERS <br />DESTROYED DURING CONSTRUCTION SHALL BE REPLACED AT CONTRACTOR'S EXPENSE. <br />8. THE CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ANY CURRENTLY APPLICABLE <br />SAFETY LAW OF ANY JURISDICTIONAL BODY. FOR INFORMATION REGARDING THIS <br />PROVISION, THE CONTRACTOR IS DIRECTED TO CONTACT STATE OF CALIFORNIA, <br />INDUSTRIAL SAFETY DEPARTMENT, SACRAMENTO, PHONE 916-445-5818. <br />9. CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY <br />FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS <br />PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS <br />REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL <br />WORKING HOURS; AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND <br />HOLD THE OWNER AND ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL <br />OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, <br />EXCEPTING FOR LIABILITY ARISING FROM THE NEGLIGENCE OF THE OWNER OR THE <br />ENGINEER. <br />� V <br />R/W <br />R/ W <br />�ilsfa// 8" Vex/uG <br />7fao 8fao 9"0 <br />FOR EXISTING WATER LINE PLAN <br />SEE SHEET 16 OF 39 OF THE <br />"THORNTON WATER PROJECT." <br />ILE NAME DRAWER <br />W _ 50 <br />GENERAL NOTES: <br />10. PRIOR TO ANY CORRECTIVE ACTION BY THE CONTRACTOR WHICH <br />IS NECESSARY <br />DUE TO STAKING ERROR, THE CONTRACTOR SHALL NOTIFY THE. <br />ENGINEER FOR <br />RESTAKING AND VERIFICATION OF PREVIOUS STAKING. SHOULD ANY CORRECTIVE <br />WORK BE DONE PRIOR TO NOTIFICATION, ..THE ENGINEER ASSUMES <br />NO LIABILITIES <br />FOR THE COSTS INCURRED FOR THIS WORK. <br />I I. CONTRACTOR SHALL SECURE ANY AND ALL PERMITS REQUIRED FOR THE PER- <br />FORMANCE OF ALL WORK SHOWN IN THESE PLANS. <br />12. WATER LINE SHALL BE ASBESTOS CEMENT PIPE (ACP) CLASS 150, <br />AWWA STANDARD C-400. <br />13. WATER LINE SHALL HAVE A MINIMUM COVER OF 4 FEET FROM <br />EXISTING EDGE OF <br />PAVEMENT OF GALT ROAD. <br />to -too 11+00 <br />EX/ST/�✓trr G`.b 6E OF' /�.9!/E/6/Erl/T <br />NOWELL ROAD <br />G <br />p�oa l+oe <br />0 <br />NOWELL <br />12+Oo t3+00 <br />( formerly GALT ROAD) <br />VICINITY MAP <br />THESE PLANS AND SPECIFICATIONS HAVE BEEN REVIEWED AND <br />APPROVED BY THE FOLLOWING DEPARTMENTS* <br />DEPARTMENT BY DATE <br />E__ i <br />1 <br />en <br />i <br />3 <br />M � <br />� Q <br />� <br />� <br />y <br />!/NDER�.POu.�/D TE'tFP�Yon/� CAacS`5 <br />Is+oo <br />lu <br />s <br />o <br />� <br />@ Qo <br />3M <br />Q •* srr > <br />h mQ m c y M� �� a hI Wx o �e <br />lb <br />4 Q Q� @AQ <br />R/ W <br />W r W <br />�iypE�q�RouNA 7'EGE�NON6 CRBCE'x it" <br />Z+oo 340 4+0o S+aO 4*00 <br />�.C/STiA/�r B17�E aF Pi4VEill�Nr �h <br />(formerly <br />R/ W <br />-30' -I _ so' <br />M 0 <br />� <br />M <br />o <br />n � <br />n <br />W <br />Q <br />o <br />3 <br />Z <br />GALT ROAD) WATER LINE EXTENSION IN <br />COUNTY SERVICE AREA N0. 12 <br />PREPARED AT THE REQUEST OF <br />H. K. PicKRELL. DEPARTMENT OF PUBLIC WORKS <br />FLYNN—L_.UND <br />ENGINEERING ---SURVEYING <br />234 WEST HARDING WAY <br />STOCKTON, CALIFORNIA <br />(209) 465-0243 <br />SAN JOAQUIN COUNTY CALIFORNIA <br />8o SCALE 1" = 40� ( 1 SHEET N0. <br />G,�i"�:� a,�- 3- _ --__-�-__ .� APPROVED BY- DATc � ._,�___._.....__.-. <br />[DESIGNED BY C.W.F.- .-. `-.�• �d 8_ <br />CJv7 _� DRAWN BY� J. D. L. —__ [ OF 2 SHEETS <br />CHARLES W. FL- N J06 NO, <br />TRACED BY 1 DIRECTOR OF P LIC WORKS <br />PE. C-24692 �— - CHECKED BY SAN JOAQUIN COUNTY 80 "2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.