A65 OR PVC
<br />P/PE � F/TT/NGS
<br />G " x 4 " REDUCING
<br />BUSHING
<br />ASS OR -YC UNLESS D/P. OR
<br />SHR /S /ND/GATED ON PLAN AND
<br />PROF/LE SJ/T. SINGLE SERV/CES-
<br />4 "O/A. , DOU41LE SE,tV/CES - G'D/A
<br />tx G Nx 4°-WYE
<br />4DAPTER AS RE00 v
<br />400 SHADED PORT/ON
<br />{ FOR DOUCLE SERVICE
<br />L�
<br />D/ A A/
<br />OROOKS k''C -5POR:-:R:5Tv -9
<br />r2� �OR E04,4_ h -� JJ�J."E-E =C✓ER
<br />RB G--DER l5,OEWA,K
<br />ELEVATION CASE 2
<br />(TYPE A'CURB, GUTTER W/5/DEWALK
<br />AND AREAS WITHNO SIDEWALK)
<br />EX/5T 5/DEWALK
<br />1
<br />I BRASS PLUG
<br />-'ER
<br />- J
<br />I
<br />4 'AB5 OR PVC CLEANOUT 404 n-_R
<br />N
<br />,O
<br />.V
<br />ALTERNATE HOUSE SER✓K'E 4 155 OR PVC SAWTARY TEE
<br />LOCAT/ONS -PLUG WITH CAP-
<br />ON TEST PLU09
<br />S-0.02 i�4 "FER FT/
<br />l2WYE REQD FOR GOUDLE
<br />SERVICE ONLY
<br />\LONG TURN
<br />TEE WYE
<br />ELEVATION CASE I
<br />(TYPE D"OR' "CURD, CUTTER J 5/DEWALK)
<br />SINGLE f DOUBLE HOUSE SERVICE
<br />LATERALS
<br />DATE
<br />SCALE NOTED
<br />DESIGNED C. S. RARXIR
<br />DRAWN: L.A. MAL/N
<br />CHECKED:0 73UNATE7
<br />PROD. ENGR.:R.A. Nf/N[N
<br />ADD SHORT
<br />LENGTH /F
<br />NEEOED—
<br />TEE OF SAME MATER/4L
<br />AS SEWER MAIN
<br />IO�MrN
<br />OROP�
<br />TTYPE A�
<br />\\/
<br />N O
<br />• TYPE B"
<br />APPROVALl GEORGE S. NOLTE AND ASSOCIATES
<br />DATE BY: 1 dkwdk .-�
<br />DATE: 31 21" 94 R. C.E 317/7
<br />BY: t
<br />DATES D•84 R.C.E.
<br />GENERAL NOTES
<br />1. LEAD AGENCY FOR THIS PROJECT IS THE COUNTY OF SAN JOAQUIN, AND UPON COM-
<br />PLETION, THE PROJECT WILL BE OPERATED AND MAINTAINED BY THE CITY OF STOCK -
<br />.TON DEPARTMENT OF MUNICIPAL UTILITIES.
<br />ALL CONSTRUCTION AND MATERIALS. SHALL BE IN CONFORMANCE TO THE CITY OF
<br />STOCKTON STANDARD SPECIFICATIONS AS REVISED JULY 1, 1981, THE CONTRACT
<br />DOCUMENTS AND THESE CONTRACT DRAWINGS. THE CONTRACT DOCUMENTS SHALL
<br />SUPERSEDE THE CITY OF STOCKTON STANDARD SPECIFICATIONS IN THE EVENT OF CON-
<br />FLICT.
<br />2. THE CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITION
<br />OF PREMISES ON WHICH THE WORK IS PERFORMED AND FOR SAFETY OF ALL PERSONS
<br />AND PROPERTY ON THE SITE, BOTH DURING AND OUTSIDE OF NORMAL WORKING HOURS,
<br />UNTIL SUCH WORK IS ACCEPTED BY THE LEAD AGENCY.
<br />3. FOR ALL EXCAVATIONS 5 FEET OR MORE IN DEPTH, THE CONTRACTOR SHALL OBTAIN
<br />A PERMIT FROM THE DIVISION OF INDUSTRIAL SAFETY (1800 COFFEE ROAD, BLDG-J,
<br />SUITE 55, MODESTO, CA, PHONE (209) 576-6260 PRIOR TO BEGINNING ANY EXCA-
<br />VATION. A COPY OF THIS PERMIT SHALL BE AVAILABLE AT THE CONSTRUCTION SITE
<br />AT ALL TIMES.
<br />4. THE COUNTY OF SAN JOAQUIN AND THE CITY OF STOCKTON ARE MEMBERS OF THE UNDER-
<br />GROUND SERVICE ALERT (U.S.A.) ONE -CALL PROGRAM. THE CONTRACTOR OR ANY
<br />SUBCONTRACTOR FOR THIS CONTRACT SHALL NOTIFY MEMBERS OF U.S.A. 48 HOURS IN
<br />ADVANCE OF PERFORMING EXCAVATION WORK BY CALLING THE TOLL -FREE NUMBER
<br />800-642-2444. EXCAVATION IS DEFINED AS BEING 18 OR MORE INCHES IN DEPTH
<br />BELOW THE EXISTING SURFACE.
<br />5. THE CONTRACTOR SHALL NOTIFY ALL UTILITY AND TRANSPORTATION COMPANIES AND
<br />AGENCIES INVOLVED IN THE CONSTRUCTION AREA OF THE PROJECT PRIOR TO BEGINNING
<br />OF WORK. SEE SEPARATE LISTING OF UTILITY TRANSPORTATION COMPANIES AND
<br />AGENCIES.
<br />6. THE TYPES, LOCATIONS, SIZES AND/OR DEPTHS OF EXISTING UNDERGROUND UTILITIES
<br />AS SHOWN ON THESE IMPROVEMENT PLANS WERE OBTAINED FROM SOURCES OF VARYING
<br />RELIABILITY. THE CONTRACTOR IS CAUTIONED THAT ONLY ACTUAL EXCAVATION WILL
<br />REVEAL THE TYPES, EXTENT, SIZES, LOCATIONS AND DEPTHS OF SUCH UNDERGROUND
<br />UTILITIES. A REASONABLE EFFORT HAS BEEN MADE TO LOCATE AND DELINEATE ALL
<br />KNOWN UNDERGROUND UTILITIES. HOWEVER, GEORGE S. NOLTE AND ASSOCIATES CAN
<br />ASSUME NO RESPONSIBILITY FOR THE COMPLETENESS OR ACCURACY OF ITS DELINEATION
<br />OF SUCH UNDERGROUND UTILITIES NOR FOR THE EXISTENCE OF OTHER BURIED OBJECTS
<br />OR UTILITIES WHICH MAY BE ENCOUNTERED BUT WHICH ARE NOT SHOWN ON THESE
<br />DRAWINGS. SEE CONSTRUCTION DOCUMENTS REGARDING UTILITY CONFLICTS.
<br />7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL EXISTING
<br />SURVEY MONUMENTS AND OTHER SURVEY MARKERS DURING CONSTRUCTION.. THE CONTRACTOR
<br />SHALL NOTIFY THE SAN JOAQUIN COUNTY DEPARTMENT OF PUBLIC WORKS OF ANY CITY,
<br />COUNTY, STATE OR U.S.G.S. MONUMENTS THAT ARE IN DANGER OF BEING DAMAGED OR
<br />REMOVED, TO PERMIT REFERENCING SUCH MONUMENTS BEFORE DISTURBANCE. ALL
<br />SUCH MONUMENTS OR MARKERS DESTROYED DURING CONSTRUCTIN SHALL BE REPLACED
<br />AT THE CONTRACTOR'S EXPENSE.
<br />8. CONTRACTOR SHALL NOTIFY GEORGE S. NOLTE AND ASSOCIATES 48 HOURS PRIOR TO
<br />REQUESTING CONSTRUCTION STAKING.
<br />9. WHENEVER THE WORK AREA IS ADJACENT TO A TRAFFIC LANE AND THERE IS A PAVEMENT
<br />CUT, DITCH OR TRENCH OVER 2 INCHES DEEP, THE CONTRACTOR SHALL MADITAIN
<br />CONTROL, WARNING AND GUIDANCE DEVICES IN ACCORDANCE WITH WORK AREA TRAFFIC
<br />CONTROL HANDBOOK PUBLISHED BY BUILDING NEWS, INC., THIRD EDITION, AND THE
<br />CONTRACT DOCUMENTS. SEE CONTRACT DOCUMENTS FOR LOCATIONS OF SPECIAL
<br />TRAFFIC REQUIREMENTS.
<br />10. PAVEMENT REPLACEMENT SHALL BE 12 INCH THICK ASPHALTIC CONCRETE FOR ALL
<br />TRENCHES WITHIN THE FOLLOWING STREETS AND FOR ALL TRENCH CROSSINGS OF THESE
<br />STREETS:
<br />FRESNO GRANT FREMONT
<br />CHURCH, GARFIELD TO LING LN UNION WASHINGTON
<br />CHURCH, STANISLAUS TO SIERRA NEVADA AIRPORT CARDINAL
<br />LINCOLN WILSON FILBERT
<br />MADISON MAIN ROUTE 4
<br />CENTER COURT
<br />EL DORADO WATERLOO
<br />SAN JOAQUIN MINER
<br />CALIFORNIA OAK
<br />STANISLAUS PARK
<br />PAVEMENT REPLACEMENT FOR STREETS NOT INCLUDED IN THE ABOVE LIST SMALL BE
<br />7 INCH THICK ASPHALTIC CONCRETE.
<br />11. THE EXISTING SEWERAGE FACILITIES SHALL BE MAINTAINED IN OPERATING CONDITION
<br />AT ALL TIMES THROUGHOUT THE CONSTRUCTION AREA.
<br />ANY WATER ENTERING THE SANITARY SEWER SYSTEM TO BE CONSTRUCTED UNDER THESE
<br />PLANS SHALL NOT BE DISCHARGED TO THE EXISTING SYSTEM. PLUGS MUST BE
<br />INSTALLED IN EXISTING MANHOLES AS NECESSARY TO PERMIT PUMPING THE NEW
<br />SYSTEM CLEAR OF WATER AND DEBRIS PRIOR TO ACCEPTANCE. CARE SHALL BE
<br />EXERCISED IN LOCATING PLUGS TO AVOID INTERRUPTING SERVICE TO EXISTING
<br />CONNECTIONS.
<br />12.. INVERT OF ALL SERVICE LATERALS ENTERING A MANHOLE WILL BE TO CROWN OF
<br />EXIT PIPE UNLESS OTHERWISE INDICATED.
<br />13. ALL SERVICE LATERALS SHALL HAVE 4.0 FEET OF COVER TO INVERT AT THE PROPERTY
<br />LINE UNLESS OTHERWISE INDICATED AND SHALL BE LOCATED AS SHOWN ON THE CON-
<br />TRACT DRAWINGS OR AS STAKED IN THE FIELD.
<br />m
<br />14. THE CONTRACTOR IS ADVISED THAT AT CERTAIN LOCATIONS THE PROPOSED
<br />SEWER TRENCH IS IN CLOSE PROXIMITY TO OR IN CONFLICT WITH THE
<br />HORIZONTAL ALIGNMENT OF EXISTING GAS MAINS. SPECIAL CARE IN
<br />EXCAVATING WILL BE NECESSARY IN THESE AREAS. RELOCATION OF GAS
<br />MAINS BY PG&E COMPANY MAY BE REQUIRED. THE CONTRACTOR SHALL
<br />COORDINATE WITH PG&E COMPANY TO DETERMINE IF AND WHEN RELOCATION
<br />WILL BE MADE OR IF OTHER PROTECTIVE ACTION BY PG&E COMPANY WILL
<br />BE TAKEN.
<br />15. THE CONTRACTOR IS ADVISED THAT AT CERTAIN LOCATIONS THE PROPOSED
<br />SEWER TRENCH IS IN CLOSE PROXIMITY TO THE BASE OF EXISTING POWER
<br />POLES, WHICH MAY REQUIRE THAT THESE POWER POLES BE BRACED DURING
<br />CONSTRUCTION. THE CONTRACTOR SHALL COORDINATE WITH PG&E COMPANY
<br />TO DETERMINE IF BRACING OR OTHER PROTECTIVE ACTION IS NECESSARY.
<br />0
<br />THE UTILITY COMPANIES, TRANSPORTATION COMPANIES AND PUBLIC AGENCIES KNOWN
<br />TO HAVE FACILITIES IN THE PROJECT AREA ARE THE FOLLOWING:
<br />A. COUNTY OF SAN JOAQUIN, DEPARTMENT OF PUBLIC WORKS, 1810 E. HAZELTON AVE.,
<br />STOCKTON, CA 95201, AL BLEVINS, PROJECT COORDINATOR, PHONE (209) 944-2281.
<br />B. CITY OF STOCKTON. DEPARTMENT OF MUNICIPAL UTILITIES, 2500 NAVY DRIVE,
<br />STOCKTON, CA 95206, WALT NICHOLS, PROJECT COORDINATOR, PHONE (209) 466-5261
<br />C. ATCHISON, TOPEKA AND SANTA FE RAILWAY COMPANY, 01 SANTA FE PLAZA,
<br />5200 SHEILA STREET, LOS ANGELES, CA 90040, Q. W. TORPIN, GENERAL
<br />MANAGER, PHONE (213) 267-54DO.
<br />D. CENTRAL CALIFORNIA TRACTION COMPANY, 1645 CHEROKEE LANE, STOCKTON, CA
<br />95207, K. J. TINKER, GENERAL MANAGER, PHONE (209) 466-6927.
<br />E. SOUTHERN PACIFIC TRANSPORTATION COMPANY, P. 0. BOX 3036, BAKERSFIELD, CA
<br />93385, R. J. VINCENT, A;SISTANT REGIONAL ENGINEER, PHONE (805) 327-2645.
<br />F. STOCKTON TERMINAL AND EASTERN RAILROAD, 1330 NORTH BROADWAY AVENUE,
<br />STOCKTON, CA 95205, B. D. SCHNEIDER, PRESIDENT, PHONE (209) 446-7001.
<br />GEORGE S. NOLTE AND ASSOCIATES
<br />SAN JOSE ■ WALNUT CREEK ■ SAN DIEGO ■ SACRAMENTO
<br />408) 287-3400 (415) 934-8060 -14, 2-8-9392 916� 446-5028
<br />/STING SEWER
<br />-TARRING 540OZE OR CONNECTER
<br />RER SRfCS
<br />CAT ERAL
<br />'CUT AWI /NTO
<br />EK. SEWEA' W/,4RRAyYEO
<br />CUTT/N6 TOOL
<br />OASKfT
<br />EX/57-/N6 SEWER rAP
<br />NTS
<br />EXIST. MANHOLE
<br />'" MAX. <_ 8" d
<br />4'MAX. > 8" o
<br />,'. I I
<br />� BREAK OUT OPEN/NG FOR
<br />T/E-IN DRY PACK CAV/Ty
<br />W/ /: / MIX.
<br />W
<br />TYP/CAL JOINT
<br />CHIP OUT NEW CHANNEL TO
<br />EX/ST/N6 FLOW CHANNEL.
<br />SMOOTH ALL AREAS W/T//
<br />NON - SHRINK EPDXY GROUT.
<br />EXIST/1V6 MANHOLE rIE- IN
<br />PLAN VIEW
<br />NTS
<br />G. UNION PACIFIC RAILROAD COMPANY, 526 MISSION STREET, ROOM 500, SAN FRANCISCO,
<br />CA 94105, J. T. SMITH, DISTRICT ENGINEER, PHONE (415) 982-21DO EXT 294.
<br />H. PACIFIC GAS AND ELECTRIC COMPANY, 4040 WEST LANE, STOCKTON. CA 59204;
<br />ERNIE ONETO, GAS SUPERINTENDENT; CARL NEILSEN, ELECTRIC SUPERVISOR (209)466-2261.
<br />I. CALIFORNIA WATER SERVICE COMPANY, 1111 NORTH EL DORADO STREET, STOCKTON,
<br />CA 95202, MITCHELL R. WYMAN, GENERAL SUPERINTENDENT, PHONE (209) 446-8971
<br />OR 464-8311.
<br />J. PACIFIC BELL COMPANY 1313-C ROBINHOOD DRIVE, STOCKTON, CA 95207, PONCE
<br />GONZALEZ, PHONE (209) 474-4734.
<br />K. BIG VALLEY CABLEVISION, 4955 NORTH WEST LAKE, STOCKTON, CA 95201, TERRY
<br />MAST, ENGINEERING DIRECTOR, PHONE (209) 473-1800.
<br />L. STATE OF CALIFORNIA, DEPARTMENT OF TRANSPORTATION, DISTRICT 10, P. 0. BOX
<br />2048, STOCKTON, CA 95201, R. B. SMITH, PERMIT ENGINEER, PHONE (209) 948-3849.
<br />-EAST STOCKTON SANITARY SEWER PROJECT -
<br />SOUTH COLLECTION SYSTEM -SCHEDULE E
<br />GENERAL NOTES AND DETAIL SHEET 2 OF 2
<br />SHEET
<br />148
<br />OF 151 SHEETS
<br />JOB NO.
<br />REVISIONS
<br />
|