GENERAL NOTES
<br />m
<br />u
<br />ol
<br />PYC OPABS &MISS DIP /S
<br />/AD/LAM ON PYAN i PROEi2E SNT.
<br />A65 om PVC SINSLE SERVICES -4"D/A.
<br />P/PE 4 f/TT/NOS I BWBCE SERY/CES -6"D/A.
<br />6x4 1-b 16 •4 WYE
<br />PLAN
<br />ADAPTER AS REQD.
<br />4"
<br />-AOD SHADED PORT/ON
<br />FOR DOUBLE SERVICE
<br />BROOKS "NO. 1-5P OR CMR/STY'NO F-B
<br />OR EQUAL WITH CONCRETE COVER
<br />T`EXIST CURB, GUrrER ¢SIDEWALK
<br />ar-
<br />I I
<br />ELEVATION CASE 2
<br />(TYPE X CUR5, GUTTER WISIDEWALK
<br />j�
<br />l
<br />A A,PEA W/TN NO S/DEWALK)
<br />EXIST 5/0EWVALK 10
<br />i
<br />1 B.RA55 PLUG -
<br />1 — EX/ST CURB Xj GUT7ER
<br />� L _J I •. I III __
<br />T -
<br />Q "ABS c2 PVC
<br />CLEA/VD//T AG4PTOP
<br />O
<br />ALTERNATE HOUSE SERVICE TPT 4A85 O.e ~C
<br />LOCH TIOA15 - PLUG
<br />ON TEST PLUGS
<br />W/TH CAP- l SAN/TARK TEG
<br />`
<br />�'\[�
<br />�/...
<br />011
<br />_
<br />S+0.02 (Yq "PER fT. J
<br />12 6x e-4 WYE READ. FOR DOUBLE
<br />0
<br />SERVICE ONLY
<br />./
<br />/
<br />GONG TURN
<br />rEE WYE
<br />ELEVAT/ON CASE J
<br />(TYPE D+ORE"CLIRB,GUTTERf SIDEWALK)
<br />Q
<br />SINGLE DOUBLE MOUSE SERVICE
<br />IAMRALS
<br />DATE1 4/25184
<br />SCALE: AS NOTED
<br />DESIGNED
<br />DRAWN:
<br />CHECKED JX 7-9-OF
<br />PROJ. ENGR.: S.H.C.
<br />a'.
<br />BY
<br />DATE
<br />REVISIONS
<br />ADD SNORT
<br />LENGTH /F
<br />NEEDED
<br />TEE OF SAME MA7ER/4L
<br />45 SEWER MA/N
<br />10'M/N
<br />TYPE B`
<br />GEORGE S. NOLTE AND ASSOCIATES
<br />� BY: 'y"t-
<br />DATE T'20-94^ 'R.C.E. NO. 77349
<br />COUNTY -OF SAN JOAOUA
<br />DATE: 1'g�5W'Ow R.CE.
<br />1. LEAD AGENCY FOR THIS PROJECT IS THE COUNTY OF SAN JOAQUIN, AND UPON COM-
<br />PLETION, THE PROJECT WILL BE OPERATED AND MAINTAINED BY THE CITY OF STOCK -
<br />TON DEPARTMENT OF MUNICIPAL UTILITIES.
<br />ALL CONSTRUCTION AND MATERIALS SHALL BE IN CONFORMANCE TO THE CITY OF
<br />STOCKTON-STANDARD SPECIFICATIONS AS REVISED JULY 1, 1981, THE CONTRACT
<br />DOCUMENTS AND THESE CONTRACT DRAWINGS. THE CONTRACT DOCUMENTS SHALL
<br />SUPERSEDE THE CITY OF STOCKTON STANDARD SPECIFICATIONS IN THE EVENT OF CON-
<br />FLICT.
<br />.2. THE CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITION
<br />OF PREMISES ON WHICH THE WORK IS PERFORMED AND FOR SAFETY OF ALL PERSONS
<br />AND PROPERTY ON THE SITE, BOTH DURING AND OUTSIDE OF NORMAL WORKING HOURS,
<br />UNTIL SUCH WORK IS ACCEPTED BY THE LEAD AGENCY.
<br />3. FOR ALL EXCAVATIONS 5 FEET OR MORE IN DEPTH, THE CONTRACTOR SHALL OBTAIN
<br />A PERMIT FROM THE DIVISION OF INDUSTRIAL SAFETY (1800 COFFEE ROAD, BLDG-J,
<br />SUITE 55, MODESTO, CA, PHONE (209) 576-6260) PRIOR TO BEGINNING ANY EXCA-
<br />VATION. A COPY OF THIS PERMIT SHALL BE AVAILABLE AT THE CONSTRUCTION SITE.
<br />AT ALL TIMES.
<br />4. THE COUNTY OF SAN JOAQUIN AND THE CITY OF STOCKTON ARE MEMBERS OF THE UNDER-
<br />GROUND SERVICE ALERT (U.S.A.) ONE -CALL PROGRAM. THE CONTRACTOR OR ANY
<br />SUBCONTRACTOR FOR THIS CONTRACT SHALL NOTIFY MEMBERS OF U.S.A. 48 HOURS IN
<br />ADVANCE OF PERFORMING EXCAVATION WORK BY CALLING THE TOLL -FREE NUMBER
<br />800-642-2444. EXCAVATION IS DEFINED AS BEING 18 OR MORE INCHES IN DEPTH
<br />BELOW. THE EXISTING SURFACE.
<br />5. THE CONTRACTOR SHALL NOTIFY ALL UTILITY AND TRANSPORTATION COMPANIES AND
<br />AGENCIES INVOLVED IN THE CONSTRUCTION AREA OF THE PROJECT PRIOR TO BEGINNING
<br />OF WORK. SEE SEPARATE LISTING OF UTILITY TRANSPORTATION COMPANIES AND
<br />AGENCIES.
<br />6. THE TYPES, LOCATIONS, SIZES AND/OR DEPTHS OF EXISTING UNDERGROUND UTILITIES
<br />AS SHOWN ON THESE IMPROVEMENT PLANS WERE OBTAINED FROM SOURCES OF VARYING
<br />RELIABILITY. THE CONTRACTOR IS CAUTIONED THAT ONLY ACTUAL EXCAVATION WILL
<br />REVEAL THE TYPES, EXTENT, SIZES, LOCATIONS AND DEPTHS OF SUCH UNDERGROUND
<br />UTILITIES. A REASONABLE EFFORT HAS BEEN MADE TO LOCATE AND DELINEATE ALL
<br />KNOWN UNDERGROUND UTILITIES. HOWEVER, GEORGE S. NOLTE AND ASSOCIATES CAN
<br />ASSUME NO RESPONSIBILITY FOR THE COMPLETENESS OR ACCURACY OF ITS DELINEATION
<br />OF SUCH UNDERGROUND UTILITIES NOR FOR THE EXISTENCE OF OTHER BURIED OBJECTS
<br />OR UTILITIES HWICH MAY BE ENCOUNTERED BUT WHICH ARE NOT SHOWN ON THESE
<br />DRAWINGS. SEE CONSTRUCTION DOCUMENTS REGARDING UTILITY CONFLICTS.
<br />7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL EXISTING
<br />SURVEY MONUMENTS AND OTHER SURVEY MARKERS DURING CONSTRUCTION. THE CONTRACTOR
<br />SHALL NOTIFY THE SAN JOAQUIN .COUNTY DEPARTMENT OF PUBLIC WORKS OF ANY CITY,
<br />COUNTY, STATE OR U.S.G.S. MONUMENTS THAT ARE IN DANGER OF BEING DAMAGED OR
<br />REMOVED, TO PERMIT REFERENCING SUCH MONUMENTS BEFORE DISTURBANCE. ALL
<br />SUCH MONUMENTS OR MARKERS DESTROYED DURING CONSTRUCTIN SHALL BE REPLACED
<br />AT THE CONTRACTOR'S EXPENSE.
<br />-EX/STIN4 SEWER
<br />ITAPP/N6 SAOOLE
<br />PER SPECS
<br />4' LATERAL
<br />—CUT 4"O/A. HOLE INTO
<br />EX. SEWER W/APPAO✓fU
<br />iiiilo CUrT/N6 TOOL
<br />"INEOPRENE OAS.PEr
<br />EX /S T/IVG SEWff TA P
<br />N rs
<br />GEORGE S. NOLTE AND ASSOCIATES
<br />SAN JOSE • WALNUT CREEK ■ SAN DIEGO ■ SACRAMENTO
<br />(408) 287-3400 (415) 934-8060 (714) 278-9392 (916) 446-5028
<br />8. CONTRACTOR SHALL NOTIFY GEORGE S. NOLTE AND ASSOCIATES 48 HOURS PRIOR TO
<br />REQUESTING CONSTRUCTION STAKING.
<br />9. WHENEVER THE WORK AREA IS ADJACENT TO A TRAFFIC LANE AND THERE IS A PAVEMENT
<br />CUT, DITCH OR TRENCH OVER 2 INCHES DEEP, THE CONTRACTOR SHALL MAINTAIN
<br />CONTROL, WARNING AND GUIDANCE DEVICES IN ACCORDANCE WITH WORK AREA TRAFFIC
<br />CONTROL HANDBOOK PUBLISHED BY BUILDING NEWS, INC., THIRD EDITION, AND THE
<br />CONTRACT DOCUMENTS. SEE CONTRACT DOCUMENTS FOR LOCATIONS OF SPECIAL
<br />TRAFFIC REQUIREMENTS.
<br />10. PAVEMENT REPLACEMENT SHALL BE 12 INCH THICK ASPHALTIC CONCRETE FOR ALL
<br />TRENCHES WITHIN THE FOLLOWING STREETS AND FOR ALL TRENCH CROSSINGS OF THESE
<br />STREETS:
<br />FRESNO GRANT
<br />CHURCH, GARFIELD TO LINCOLN UNION
<br />CHURCH, STANISLAUS TO SIERRA NEVADA AIRPORT
<br />LINCOLN WILSON
<br />MADISON MAIN
<br />CENTER COURT
<br />EL DORADO WATERLOO
<br />SAN JOAQUIN MINER
<br />CAL IFORNLA OAK
<br />STANISLAUS PARK
<br />PAVEMENT REPLACEMENT FOR STREETS NOT INCLUDED IN THE ABOVE LIST SHALL BE
<br />7 INCH THICK ASPHALTIC CONCRETE.
<br />11. THE EXISTING SEWERAGE FACILITIES SHALL BE MAINTAINED IN OPERATING CONDITION
<br />AT ALL TIMES THROUGHOUT THE CONSTRUCTION AREA.
<br />ANY WATER ENTERING THE SANITARYSEWER SYSTEM TO BE CONSTRUCTED UNDER THESE
<br />PLANS SHALL NOT BE DISCHARGED TO THE EXISTING SYSTEM. PLUGS MUST BE
<br />INSTALLED IN EXISTING MANHOLES AS NECESSARY TO PERMIT PUMPING THE NEW
<br />SYSTEM CLEAR OF WATER AND DEBRIS PRIOR TO ACCEPTANCE. CARE SHALL BE
<br />EXERCISED IN LOCATING PLUGS TO AVOID INTERRUPTING SERVICE TO EXISTING
<br />CONNECTIONS.
<br />12. INVERT OF ALL SERVICE LATERALS ENTERING A MANHOLE WILL BE TO CROWN OF
<br />EXIT PIPE UNLESS OTHERWISE INDICATED.
<br />13. ALL SERVICE LATERALS SHALL HAVE 4.0 FEET OF COVER TO INVERT AT THE PROPERTY
<br />LINE UNLESS OTHERWISE INDICATED AND SHALL BE LOCATED AS SHOWN ON THE CON-
<br />TRACT DRAWINGS OR AS STAKED IN THE FIELD.
<br />14. THE CONTRACTOR IS ADVISED THAT AT CERTAIN LOCATIONS THE PROPOSED SEWER TRENCH
<br />IS IN CLOSE PROXIMITY TO OR IN CONFLICT WITH THE HORIZONTAL ALIGNMENT OF
<br />EXISTING GAS MAINS. SPECIAL CARE WILL BE NECESSARY IN EXCAVATING IN THESE
<br />AREAS. RELOCATION OF GAS MAINS BY PG&E CO. MAY BE REQUIRED. THE CONTRACTOR
<br />SHALL COORDINATE WITH PG&E CO. TO DETERMINE IF AND WHEN RELOCATION WILL BE
<br />MADE OR IF OTHER PROTECTIVE ACTION BY PG&E COMPANY WILL BE TAKEN.
<br />15. THE CONTRACTOR IS ADVISED THAT AT CERTAIN LOCATIONS THE PROPOSED SEWER TRENCH
<br />IS IN CLOSE PROXIMITY TO THE BASE OF EXISTING POWER POLES, WHICH MAY REQUIRE
<br />THAT THESE POWER POLES BE BRACED DURING CONSTRUCTION. THE CONTRACTOR SHALL
<br />-COORDINATE WITH PG&E CO. TO DETERMINE IF BRACING OR OTHER PROTECTIVE ACTION
<br />IS NECESSARY.
<br />THE UTILITY COMPANIES, TRANSPORTATION COMPANIES AND PUBLIC AGENCIES KNOWN
<br />TO HAVE FACILITIES IN THE PROJECT AREA ARE THE FOLLOWING:
<br />A. COUNTY OF SAN JOAQUIN, DEPARTMENT OF PUBLIC WORKS, 1810 E. RAZELTON AVE.,
<br />STOCKTON, CA 95201, AL BLEVINS, PROJECT COORDINATOR, PHONE (209) 944-2281.
<br />B. CITY OF STOCKTON, DEPARTMENT OF MUNICIPAL UTILITIES, 2500 NAVY DRIVE,
<br />STOCKTON, CA 95206, WALT NICHOLS, PROJECT COORDINATOR, PHONE (209) 466-5261.
<br />C. ATCHISON, TOPEKA AND SANTA FE RAILWAY COMPANY, 61 SANTA FE PLAZA,
<br />5200 SHEIIA STREET, LOSS ANGELES, CA 90040, Q. W. TORPIN, GENERAL
<br />MANAGER, PHONE (213) 267-5400.
<br />D. CENTRAL CALIFORNIA TRACTION COMPANY, 1645 CHEROKEE LANE, STOCKTON, CA
<br />95207, K. J. TINKER, GENERAL MANAGER, PHONE (209) 466-6927.
<br />E. SOUTMERN PACIFIC TRANSPORTATION COMPANY, P. 0. BOX 3036, BAKERSFIELD, CA
<br />93385, R. J. VINCENT, ASSISTANT REGIONAL ENGINEER, PHONE (805) 327-2645.
<br />F. STOCKTON TERMINAL AND EASTERN RAILROAD, 1330 NORTH BROADWAY AVENUE,
<br />STOCKTON, CA 95205, B. D. SCHNEIDER, PRESIDENT, PHONE (209) 446-7001.
<br />G. UNION PACIFIC RAILROAD COMPANY, 526 MISSION STREET, ROOM 500, SAN FRANCISCO,
<br />CA 94105, J. T. SMITH, DISTRICT ENGINEER, PHONE (415) 982-2100 EXT 294.
<br />H. PACIFIC GAS AND ELECTRIC COMPANY, 4040 WEST LANE, STOCKTON, CA 59204;
<br />ERNIE ONETO, GAS SUPERINTENDENT; CARL NEILSEN, ELECTRIC SUPERVISOR (209)466-2261.
<br />I. CALIFORNIA WATER SERVICE COMPANY, 1111 NORTH EL DORADO STREET, STOCKTON,
<br />CA 95202, MITCHELL R. WYMAN, GENERAL SUPERINTENDENT, PHONE (209) 446-8971
<br />OR 464-8311.
<br />J. PACIFIC BELL COMPANY 1313-C ROBINHOOD DRIVE, STOCKTON, CA 95207, PONCE
<br />CONZALEZ, PHONE (209) 474-4734.
<br />K. BIG VALLEY CABLEVISION, 4955 NORTH WEST LANE, STOCKTON, CA 95201, TERRY
<br />MAST, ENGINEERING DIRECTOR, PHONE (209) 473-1800.
<br />L. STATE OF CALIFORNIA, DEPARTMENT OF TRANSPORTATION, DISTRICT 10, P. 0. BOX
<br />2048, STOCKTON, CA 95201, R. B. SMITH, PERMIT ENGINEER, PHONE (209) 948-3849.
<br />-EAST STOCKTON SANITARY SEWER PROJECT -
<br />NORTH COLLECTION SYSTEM - SCHEDULE D
<br />DETAIL SHEET AND NOTES
<br />SHEET
<br />125
<br />OF 127 SHEETS
<br />JOB NO.
<br />2181-83-26
<br />
|