My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
PW-ENCDRWY-2403198
PublicWorks
>
- PUBLIC SERVICES
>
PERMITS & DEVELOPMENT
>
Encroachment(EP)/Driveway(DW) Permits
>
2024
>
Driveway Permits
>
PW-ENCDRWY-2403001 thru PW-ENCDRWY-2403500
>
PW-ENCDRWY-2403198
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2025 8:47:37 AM
Creation date
4/7/2025 8:45:30 AM
Metadata
Fields
Template:
Permits_Development_Driveway
DocName
PW-ENCDRWY-2403198
Category07
Encroachment(EP)/Driveway(DW) Permits
Year2
2024
Location
N. Thornton Road near Capitol Ave.
Driveway Type
Commercial
Address
3500 Deer Creek Road, Palo Alto, CA 94304
Application
Tesla
Project #
PWP110005
Type
Driveway Encroachment
Text box
ID:
1
Creator:
Created:
4/7/2025 8:46 AM
Modified:
4/7/2025 8:46 AM
Text:
10/30/2024
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CCCCCCCCCCCCCCCCCM SEL 700G <br />ISLANDING <br />CONTROLLER <br />PV <br />METER <br />M BATT <br />METER <br />M SITE <br />METER <br />(FUTURE) <br />MEGAPACKCCC CCCCCC <br />C C C <br />C C <br />C C C C CCSUPERCHARGER <br />POST <br />A <br />POST <br />B <br />POST <br />C <br />POST <br />D <br />TYP. 4CCCC <br />TO DC <br />POST <br />TO CURRENT <br />TRANSFORMERS <br />CTs <br />C <br />LEGEND <br />CAT5E OR CAT6 CABLE <br />CONTROL TRANSFORMER COIL LEADS <br />·DEFAULT LEAD LENGTH IS 8FT. LEADS MAY BE <br />EXTENDED UP TO 20 METERS USING A MIN. OF <br />12AWG CU SHIELDED CONDUCTORS. <br />TESLA STANDARD IP ADDRESSES <br />BESS METER SITE METER PV METER SEL700G RELAY CPS FLEX GATEWAY <br />METER #1 192.168.90.201 192.168.90.210 192.168.90.220 192.168.90.50 192.168.XX.XXX <br />METER #2 192.168.90.202 192.168.90.211 192.168.90.221 -- <br />METER ............-- <br />METER #9 192.168.90.209 ......-- <br />METER #10 N/A 192.168.90.219 192.168.90.229 -- <br />CTs <br />FACTORY <br />INSTALLED <br />WIRING <br />COMMUNICATION DIAGRAMC <br />TESLA SIGNAL COMMUNICATION WIRES <br />·1000V RATED <br />TESLA SITE CONTROLLER #1 & #2 <br />BEES/PV SYSTEM (TSC-ESPV-1) <br />SPARE (TSC-ESPV-2) <br />CONTROLLER #1 <br />(TSC-ESPV-1) <br />LAN1 <br />CONTROLLER #2 <br />(TSC-ESPV-2) <br />LAN2 <br />C <br />LAN1 LAN2 LAN1 LAN2 <br />C <br />FACTORY INSTALLED WIRING. <br />TESLA SIGNAL WIRES ARE <br />RATED TO 1000V AND MAY RUN <br />IN SAME CONDUIT AS DC <br />CONDUCTORS <br />C <br />CC C C C C CC <br />FIELD <br />INSTALLED <br />WIRING <br /> 12-PORT SWITCH <br />CONTROLLER #3 <br />(TSC-SPR-1) <br /> 12-PORT SWITCH <br />TESLA SITE CONTROLLER #3 <br />SPR 1 (TSC-SPR-1) <br />(FUTURE) CPS <br />INVERTER <br />"IN-1.1" <br />(FUTURE) <br />CPS FLEX <br />GATEWAY <br />(FUTURE) CPS <br />INVERTER <br />"IN-2.1" <br />(FUTURE) <br />CPS FLEX <br />GATEWAY <br />(FUTURE) CPS <br />INVERTER <br />"IN-2.2"CCCCCCCCC <br />CCCCCCCCCC <br />CCCCPS FLEX GATEWAY - FLEXOM-PP <br />·ONLY ONE CPS FLEX GATEWAY IS REQUIRED <br />PER INVERTER COMMUNICATION CHAIN, TO BE <br />INSTALLED IN THE INVERTER CLOSEST TO THE <br />TESLA SITE CONTROLLER. <br />·THERE CAN BE MORE THAN ONE INVERTERS <br />COMMUNICATION CHAIN. <br />·AMOUNT OF CHAINS WILL DEPEND OF MAXIMUM <br />ALLOWED LENGTH OF COMMUNICATION WIRES <br />AND INVERTERS LOCATION. <br />·SHEILDED AND OUTDOOR RATED <br />·INSTALL IN CONDUIT SEPARATELY FROM <br />POWER CONDUCTORS IN A 1" CONDUIT <br />·METAL CONNECTORS FOR THE CAT <br />CABLES TERMINATING AT THE TESLA SITE <br />CONTROLLER ARE REQUIRED. <br />CONNECTORS AT CONTROL DEVICES ARE <br />TO BE PLASTIC. <br />·328FT MAX LENGTHRS485CPS-RS <br />RS485 <br />RS-485 CABLE <br />·RS-485 CABLE, USE BELDEN 3107A OR SIMILAR <br />·2 PAIR 22AWG, SHIELDED, UV RESISTANT AND <br />WITH DRAIN WIRE. <br />·INSTALL IN CONDUIT SEPARATELY FROM POWER <br />CONDUCTORS. <br />·1640FT MAX LENGTH FROM FARTHEST INVERTER <br />TO CPS FLEX GATEWAY <br />·FOLLOW CPS INVERTER INSTALLATION MANUAL <br />FOR CONNECTIONS SPECS. <br />MP-COMMINV-COMM <br />(FUTURE) CPS <br />INVERTER <br />"IN-3.1" <br />(FUTURE) <br />CPS FLEX <br />GATEWAY <br />(FUTURE) CPS <br />INVERTER <br />"IN-3.2"CCCCCCCCCC <br />CCCCRS485FIELD INSTALLED <br />WIRING <br />FIELD INSTALLED <br />WIRING CCCCCC <br />TO DC <br />POST <br />(FUTURE) <br />SUPERCHARGER <br />TYP. 4CC <br />TO DC <br />POST <br />C C C CCPS-RSCPS-RS <br />SPR-COMM-SP <br />FIELD INSTALLED <br />WIRING <br />SPR-COMM <br />FIELD INSTALLED <br />WIRING <br />1"12"0 <br />PROPRIETARY AND CONFIDENTIAL <br />ABCDEFGH <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />DATENO.REVISIONORIGINAL SIZE 24"X36" <br />SHEET SIZE ARCH "D" <br />3500 DEER CREEK RD. <br />PALO ALTO, CA 94304 <br />(650) 681-5000 <br />3/27/2024AARCH SITE PLAN COMMENTS10/18/2024BCIVIL AND BUILDING COMMENTS14700 THORNTON RDLODI, CA 95242, USCOMMS <br />DIAGRAM <br />E-211 <br />REV: B IFP <br />MVANDERWALPLOT DATE: 10/25/2024 9:25 a. m. <br />JB-9528024TESLA SUPERCHARGER_LODI, CAPHASE 1: 16 SUPERCHARGERSCOMMUNICATION CIRCUIT SCHEDULE <br />CIRCUIT ## OF <br />CONDUITS <br /># SPARE <br />CONDUITS SIGNAL WIRE CONDUIT <br />TYPES <br />MIN <br />CONDUIT <br />SIZE (IN) <br />MP-COMM*-1 CAT6/5E PVC 1 <br />INV-COMM*-1 CAT6/5E PVC 1 <br />SPR-COMM 1 -CAT6/5E PVC 1 <br />SPR-COMM-SP*-1 CAT6/5E PVC 1 <br />* CONDUCTORS TO BE INSTALLED UNDER SEPARATE PERMIT, <br />CONDUITS INSTALLED UNDER THIS PERMIT.
The URL can be used to link to this page
Your browser does not support the video tag.