Laserfiche WebLink
WV <br />WV EV CHARGINGONLYEV CHARGINGONLYEV CHARGING <br />ONLY <br />NO <br />PARKINGSTAR STDE BROGGI RDNOPARKINGEV CHARGINGONLYPLAN VIEWCONDUIT ENTRYEV CHARGINGONLY25' <br />DRIVE AISLE <br />25' <br />DRIVE AISLE <br />12' <br />20' <br />TYP. <br />9' <br />TYP.9'5' <br />20' <br />TYP. <br />9' <br />TYP. <br />20' <br />TYP. <br />9' <br />TYP. <br />20' <br />TYP. <br />9' <br />TYP. <br />10' <br />25' <br />DRIVE AISLE <br />4' <br />26'-10" <br />DRIVE <br />AISLE <br />9' <br />5'-6" <br />11'-5" <br />9' <br />26'-9" <br />20' <br />(E) PROPERTY <br />LINE <br />(N) 4’’ WHITE PARKING <br />STRIPING, TYP. <br />(N) 4’’ WIDE WHITE STRIPING WITH 4’’ <br />WIDE WHITE CROSS STRIPING @36’’ O.C. <br />(N) ACCESSIBLE ROUTE TO <br />PEDESTRIAN ENTRANCE <br />(N) ACCESSIBLE <br />EV STALLS, <br />REF A-301 <br />(E) SIDEWALK <br />(FUTURE) PV CANOPY <br />COLUMN, TYP. <br />(FUTURE) PV CANOPY <br />ABOVE <br />PSU'S TO BE FLUSH WITH <br />ASPHALT TO BE ACCESSIBLE <br />COMPLIANT <br />25' <br />DRIVE AISLE <br />10' <br />P.U.E <br />25' <br />10' <br />P.U.E <br />27' TYP. <br />25' <br />DRIVE <br />AISLE <br />WIDTH <br />11'-5" <br />9' <br />20' <br />TYP. <br />9' <br />TYP.10' <br />(N) MCCUE BOLLARD,(TYP. 9), <br />PER STRUCTURAL <br />(E) CHAIN LINK FENCE <br />FUTURE PV <br />CANOPIES <br />ABOVE <br />(N) UTILITY BOLLARDS, <br />(TYP. 4), PER UTILITY REQUIREMENTS, <br />REF. PG&E DOC. #051122 <br />32'-8" <br />CANOPY TO <br />CANOPY <br />31'-8" <br />CANOPY TO <br />CANOPY <br />(N) ACCESSIBLE PARKING SIGN <br />MOUNTED ON REBOUNDING BOLLARD <br />10'-11" <br />4'-11" <br />29' <br />15'-9" <br />5'-6" <br />28'-10" <br />161'-7" <br />24'-8" <br />33'-5" <br />69'-1" <br />204'-6" <br />99'-2" <br />OUTLINE OF AREA OF <br />AC PAVING <br />AREA OF NO AC PAVEMENT <br />AT PHASE 1 <br />34'-10" <br />(E) PROPERTY LINE <br />(N) REMOVABLE BOLLARD,(TYP. 3), <br />PER STRUCTURAL <br />11'-5" <br />6'-6" <br />FUTURE EV CHARGE <br />STALLS AND PV CANOPY <br />FUTURE EV CHARGE <br />STALLS AND PV CANOPY <br />(N) DRIVEWAY TRANSITION <br />AS REQUIRED, REF. A-501 <br />(N) CONCRETE CURB <br />AND GUTTER, TYP., REF. CIVIL <br />43'-6"(N) PMI "PMI-1", PER <br />UTILITY DESIGN <br />XR-1 <br />SB-1 <br />PSU-2 <br />SPR-2 <br />AP-1 <br />SPR-3 PSU-1 <br />SPR-1 <br />FUTURE BATTERY ENERGY STORAGE SYSTEM <br />·BESS, GROUNDING TRANSFORMER, AND LINE <br />REACTOR EQUIPMENT PAD & ASSOCIATED CONDUIT <br />PART OF THIS PERMIT, REF. ELECTRICAL & <br />STRUCTURAL <br />·2,284.8 KWH LITHIUM BATTERY ENERGY <br />STORAGE SYSTEM "MEGAPACK 2" EQUIPMENT/WIRING <br />INSTALLATION UNDER SEPARATE PERMIT. <br />PSU-3 <br />XR-2 <br />SB-2 <br />LC-1 <br />(FUTURE) PMI <br />"PMI-2", PER <br />UTILITY DESIGN <br />IN-1.1 <br />(E) OVERHEAD ELECTRIC <br />LINE, TYP. REF. G-002 <br />FOR SITE LEGEND OF <br />EXISTING OBJECTS <br />PSU-4 <br />SPR-4 <br />CLEARANCE FROM PAD EDGE 8' ON <br />DOOR SIDES AND 3' ON NON-DOOR <br />SIDES (VERIFY WITH UTILITY <br />REQUIREMENTS) <br />CLEARANCE FROM PAD EDGE 8' ON <br />DOOR SIDES AND 3' ON NON-DOOR <br />SIDES (VERIFY WITH UTILITY <br />REQUIREMENTS) <br />(E) UTILITY LINE <br />5'-6" <br />TYP. <br />1' <br />(N) GROOVED BORDER, <br />REF. A-501 <br />(N) TRUNCATED <br />DOMES, REF. A-501 <br />5' <br />(N) GRAVEL <br />(N) GRASSY FILTER STRIP, PER CIVIL <br />FUTURE CURB TO BE FLUSHED <br />WITH SURROUNDING GRADE <br />IN-3.1 <br />IN-3.2 <br />IN-2.1 <br />IN-2.2 <br />ARCHITECTURAL SITE PLAN <br />1/16" = 1'-0" <br />N <br />S <br />EW <br />SITE LEGEND <br />ACCESSIBLE <br />(N) FULL DEPTH ASPHALT <br />PARKING SIGN, REF A-501 <br />EXISTING STANDARD STALLS <br />UTILIZED AS A RESULT OF THIS <br />PROJECT <br />0 <br />PROPOSED TESLA STALLS 16 <br />PROPOSED STANDARD STALLS 0 <br />NET STALL COUNT +16 <br />PARKING STALL SCHEDULE <br />PHASE 1 <br />VAN <br />ACCESSIBLE <br />0 1'32'16' <br />EXISTING STANDARD STALLS <br />UTILIZED AS A RESULT OF THIS <br />PROJECT <br />0 <br />PROPOSED TESLA STALLS 52 <br />PROPOSED STANDARD STALLS 0 <br />NET STALL COUNT +52 <br />PARKING STALL SCHEDULE <br />PHASE 2 <br />EV CHARGE STALL SCHEDULE <br />EV CHARGE STALLS <br />PROPOSED 16 <br />ADA EV <br />STALL TYPE <br />CAR VAN AMBULATORY <br />STALLS <br />REQUIRED <br />1 1 0 <br />STALLS <br />PROPOSED <br />1 1 2 <br />BASED ON CBC TABLE 11B-228.3.2.1 <br />CODE COMPLIANCE: <br />ALL WORK SHALL BE INSTALLED IN <br />COMPLIANCE WITH CALIFORNIA <br />BUILDING CODE. APPLICABLE CODE ARE <br />AS STATED. <br />ACCESSIBLE STALLS <br />STANDARD: 11B-812.6.2 <br />VAN: 11B-812.6.1 <br />AMBULATORY:11B-812.6.3 <br />ACCESS AISLE:11B-812.7 <br />ACCESSIBLE ROUTE: 11B-812.5 <br />ISA SIGNAGE:11B-812.8 <br />ADA SURFACE MARKINGS:11B-812.9 <br />PER CALIFORNIA ASSEMBLY BILL AB-970: <br />IF AN ELECTRIC VEHICLE CHARGING <br />STATION AND ANY ASSOCIATED <br />EQUIPMENT INTERFERE WITH, REDUCE, <br />ELIMINATE, OR IN ANY WAY IMPACT THE <br />REQUIRED PARKING SPACES FOR <br />EXISTING USES, THE CITY, COUNTY, OR <br />CITY AND COUNTY SHALL REDUCE THE <br />NUMBER OF REQUIRED PARKING <br />SPACES FOR THE EXISTING USES BY THE <br />AMOUNT NECESSARY TO ACCOMODATE <br />THE ELECTRIC VEHICLE CHARGING <br />STATION AND ANY ASSOCIATED <br />EQUIPMENT. <br />NOTES <br />SERVICE SIDE <br />(N) CHARGE POST <br />(N) UTILITY BOLLARD <br />(FUTURE) PV CANOPY <br />FOUNDATION AND COLUMN <br />(N) REBOUNDING BOLLARD <br />SIGN <br />(N) MCCUE BOLLARD <br />(N) POLE-MOUNTED LIGHT <br />FIXTURE <br />(N) REMOVABLE BOLLARD <br />EQUIPMENT TAGS <br />SPR-#SUPERCHARGER CABINET <br />XR-#TRANSFORMER (PROVIDED <br />BY UTILITY PER UTILITY <br />DESIGN) <br />PSU-#PRE ASSEMBLED <br />SUPERCHARGER UNIT <br />FUTURE PHOTOVOLTAIC <br />INVERTERIN-#.# <br />WIFI ACCESS POINTAP-# <br />FUTURE LOAD CENTERLC-#XR-#FUTURE TRANSFORMER <br />(PROVIDED BY UTILITY PER <br />UTILITY DESIGN) <br />SB-#SWITCHBOARD <br />FUTURE SWITCHBOARDSB-# <br />1"12"0 <br />PROPRIETARY AND CONFIDENTIAL <br />ABCDEFGH <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />DATENO.REVISIONORIGINAL SIZE 24"X36" <br />SHEET SIZE ARCH "D" <br />3500 DEER CREEK RD. <br />PALO ALTO, CA 94304 <br />(650) 681-5000 <br />3/27/2024AARCH SITE PLAN COMMENTS10/18/2024BCIVIL AND BUILDING COMMENTS14700 THORNTON RDLODI, CA 95242, USARCHITECTURAL <br />SITE PLAN <br />A-101 <br />REV: B IFP <br />MVANDERWALPLOT DATE: 10/25/2024 9:27 a. m. <br />JB-9528024 <br /> TESLA SUPERCHARGER_LODI, CAPHASE 1: 16 SUPERCHARGERSB <br />B <br />B <br /> Signed <br /> Date: <br />10/28/24 <br />(E) PROPERTY <br />LINE