N. Thornton Road near Capitol Ave.
Driveway Type
Commercial
Address
3500 Deer Creek Road, Palo Alto, CA 94304
Application
Tesla
Project #
PWP110005
Type
Driveway Encroachment
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
A501.1105 BOLLARD MOUNTED ACCESSIBLE EV SIGN DETAIL RB <br />REBOUNDING BOLLARD MOUNTED EV SIGN <br />NTS <br />REBOUNDING BOLLARD <br />PRE-ASSEMBLED WITH <br />PRE-CAST SUPERCHARGER <br />FOUNDATION, PER <br />STRUCTURAL <br />3' <br />NOTE: SIGNAGE MUST BE <br />PLACED WITHIN THE <br />PROJECTED HEAD END OF THE <br />PARKING SPACE <br />IN CALIFORNIA, ISA SIGNAGE <br />PER CBC 11B-812.8 <br />60" MIN. - NOT LOCATED IN CIRCULATION PATHS80" MIN. - TO BOTTOM OF ANY SIGNFREESTANDING IN CIRCULATION PATHSBOLTED OR <br />WELDED CAP <br />ACCESSIBLE <br />SIGN & <br />DESIGNED FOR <br />DISABLED <br />ACCESS - USE <br />LAST SIGN PER <br />PLAN & PER B/- <br />2" X 2" SQUARE POWDER <br />COATED GRAY HSS TUBE <br />SIGN POST, ONLY <br />REQUIRED WHEN SIGNS <br />ARE REQUIRED <br />3/8" DIA. ALUMINUM <br />SECURITY PIN BOLT <br />RIVET W/ 3/4" DIA. DOME <br />HEAD FLANGE & .330" <br />GRIP LENGTH <br />MOUNTING OPTIONS: <br />1.SIGN CAN BE INSTALLED ON WALL USING ANCHOR <br />SYSTEM MATCHING WALL TYPE. <br />2.SIGN CAN BE POLE MOUNTED PER <br />SPECIFICATIONS IN POLE MOUNTED SIGN DETAILS. <br />SIGN MATERIAL: ALUMINUM <br />A501.1119 TESLA EV STALL PARKING SIGN - VAN ACCESSIBLE RA <br />TESLA EV STALL PARKING SIGN - VAN ACCESSIBLE <br />NTS <br />12"12"12"12"12"12"12" <br />18" <br />1/2" RADIUS SIGN <br />CORNER <br />WHITE SYMBOL <br />WHITE TEXT AT VAN <br />ACCESSIBLE STALL ONLY <br />VAN <br />ACCESSIBLE <br />DESIGNED FOR <br />DISABILITY ACCESS - <br />USE LAST <br />WHITE TEXT <br />6" <br />SOLID FEDERAL BLUE <br />#15090 IN FED <br />STANDARD 595C <br />BACKGROUND PAINT <br />60" MIN <br />A.F.F. <br />SIGN TO HAVE <br />REFLECTIVE FINISH <br />4" WHITE <br />BORDER AT <br />AISLE AND <br />PARKING, <br />TYP. <br />18' <br />MIN <br />EV CHARGING <br />ONLY <br />VAN ACCESSIBLE <br />12' MIN <br />CODE COMPLIANCE: <br />STALL SPECIFICATIONS PER CBC 11B-812.6 <br />SURFACE MARKINGS PER CBC 11B-812.9 <br />ACCESS AISLE PER CBC11B-812.7 <br />A501.1114 EV CHARGE ACCESSIBLE STALLS - VAN & STANDARD RA <br />NO <br />PARKING <br />5' MIN <br />36" <br />MAX <br />EV CHARGE ACCESSIBLE STALLS - VAN & STANDARD <br />NTS <br />EV CHARGING <br />ONLY <br />STD ACCESSIBLE <br />9' MIN <br />4" WHITE 45° LINES AT 36" <br />O.C. MAX. TYP. MATCH <br />EXISTING ANGLE <br />ORIENTATION WHERE <br />APPLICABLE <br />SIGN PER <br />PLAN, TYP. <br />NOTES: <br />MAX.SLOPE 1:48 AT STALL AND AISLE IN ALL DIRECTIONS,TYP. <br />ALL DIMS ARE TO CENTERLINE OF STRIPING <br />WHITE LETTERING 12" MIN <br />HEIGHT, TYP. <br />C <br />A501.208 WALKWAY PAVEMENT DETAIL RB <br />WALKWAY PAVEMENT DETAIL <br />NTS <br />4" MIN. THICK <br />CONCRETE W/ 6x6 <br />WWF-W1.4/1.4 @ MID <br />SLAB <br />PER PLAN <br />COMPACTED <br />SUBGRADE <br />4" MIN. AGGREGATE <br />SUBBASE COMPACT TO <br />95% STANDARD <br />PROCTOR DENSITY <br />1/2" <br />FLUSH LEVEL CONNECTION <br />@NEW OR EXISTING PAVED <br />SURFACES <br />1/2" <br />@TURF <br />E <br />TOP VIEW <br />BOTTOM VIEW <br />CONCRETE SURFACES: ANCHOR WITH (4) <br />MANUFACTURER PROVIDED CONCRETE ANCHORS <br />LANDSCAPE AREAS: ANCHOR WITH (4) MIN. 12" <br />LONG J-HOOK REBAR ANCHORS <br />3'-6" <br />NTS <br />2'-4" <br />Ø0.5" <br />ANCHOR <br />HOLE <br />(TYP.) <br />11" <br />8.73" <br />S501.1364 TRASH BIN DETAIL RA <br />(E) CONCRETE <br />SLAB OR <br />LANDSCAPE <br />FRONT <br />VIEW <br />TRASH & RECYCLING BIN DETAIL <br />NOTE: <br />TRASH & RECYCLING BINS TO BE PROVIDED <br />BY TESLA <br />RECYCLE <br />ONLY USE BLUE BIN W/ <br />"RECYCLE" TEXT & <br />SYMBOLS IN <br />LOCATIONS INDICATED <br />ON SITE PLAN (IF ANY) <br />G <br />4" <br />4" WHITE <br />BORDER AT <br />PARKING <br />(TYP) <br />18' <br />MIN. <br />MAX.SLOPE 1:48 AT <br />STALL IN ALL <br />DIRECTIONS,TYP. <br />10' MIN <br />WHITE LETTERING <br />12" MIN HEIGHT <br />NOTE: <br />ALL DIMS ARE TO <br />CENTERLINE OF <br />STRIPING <br />CODE COMPLIANCE: <br />STALL SPECIFICATIONS PER CBC 11B-812.6.3 <br />ADA SURFACE MARKINGS PER CBC 11B-812.9 <br />A501.1121 EV CHARGE STALL STRIPING - AMBULATORY ACCESSIBLE RB <br />EV CHARGING <br />ONLY <br />EV CHARGE ACCESSIBLE STALL - AMBULATORY <br />NTSD <br />COUNTY OF SAN JOAQUIN - COMMERCIAL TYPE GUTTER & DRIVEWAY <br />NTSF <br />B <br />A <br />NOTE: TACTILE WARNING SURFACE TILE WITH <br />TRUNCATED DOMES AND BEVELED EDGES, <br />CONFORMING TO ADA & CBC REQUIREMENTS. <br />COLOR YELLOW AND APPROXIMATE 33538 OF SAE <br />AMSSTD-595A. SURFACE APPLIED TO (E) PAVING <br />WITH ADHESIVE, PERIMETER FASTENERS, AND <br />CAULK PER MANUFACTURERS INSTRUCTIONS. <br />2.3"-2.4" <br />2.3"-2.4" <br />.9"-.92" <br />.45" <br />- <br />.47" <br />.2" <br /> .135" <br />12 <br />CROSS SECTION, TYP. <br />TILE JOINT FLUSH <br />TRANSITION <br />2.3"-2.4" <br />A501.1103 TRUNCATED DOMES DETAIL RA <br />TACTILE SURFACE TILE W/ TRUNCATED DOMES <br />NTS <br />- <br />- <br />.65" MIN <br />H <br />1"12"0 <br />PROPRIETARY AND CONFIDENTIAL <br />ABCDEFGH <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />DATENO.REVISIONORIGINAL SIZE 24"X36" <br />SHEET SIZE ARCH "D" <br />3500 DEER CREEK RD. <br />PALO ALTO, CA 94304 <br />(650) 681-5000 <br />3/27/2024AARCH SITE PLAN COMMENTS10/18/2024BCIVIL AND BUILDING COMMENTS14700 THORNTON RDLODI, CA 95242, USDETAILS <br />A-501 <br />REV: B IFP <br />MVANDERWALPLOT DATE: 10/25/2024 9:28 a. m. <br />JB-9528024 <br /> TESLA SUPERCHARGER_LODI, CAPHASE 1: 16 SUPERCHARGERSB <br /> Signed <br /> Date: <br />10/28/24