PW-ENCDRWY-2403198
PublicWorks
>
- PUBLIC SERVICES
>
PERMITS & DEVELOPMENT
>
Encroachment(EP)/Driveway(DW) Permits
>
2024
>
Driveway Permits
>
PW-ENCDRWY-2403001 thru PW-ENCDRWY-2403500
>
PW-ENCDRWY-2403198
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2025 8:47:37 AM
Creation date
4/7/2025 8:45:30 AM
Metadata
Fields
Template:
Permits_Development_Driveway
DocName
PW-ENCDRWY-2403198
Category07
Encroachment(EP)/Driveway(DW) Permits
Year2
2024
Location
N. Thornton Road near Capitol Ave.
Driveway Type
Commercial
Address
3500 Deer Creek Road, Palo Alto, CA 94304
Application
Tesla
Project #
PWP110005
Type
Driveway Encroachment
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
WV <br />WV EV CHARGINGONLYEV CHARGINGONLYEV CHARGING <br />ONLY <br />NO <br />PARKINGSTAR STNOPARKINGEV CHARGINGONLYPLAN VIEWCONDUIT ENTRYEV CHARGINGONLY11111313 <br />(10.74) <br />(12.73) <br />(12.31) <br />(13.23)(13.14) <br />(12.78)(12.62) <br />(12.26) <br />(11.31) EG <br />(11.24) EG <br />(13.11)(13.12) <br />11.50 FG <br />(11.71) BC <br />(11.80) EG <br />11.50 FG <br />(12.96) <br />(12.91)ADA PARKING AREA MAX SLOPE 48:1 <br />(N) ADA PATH, TYP., MAX 5% <br />LONGITUDINAL GRADE, <br />MAX 2% CROSS GRADE <br />(N) PRE-ASSEMBLED UNIT, (TYP. 4), <br />MIN CROSS-SLOPE 1%, <br />MAX CROSS-SLOPE 2%, <br />MAX LONGITUDINAL SLOPE 5% <br />LIMITS OF GRADING <br />(EARTH DISTURBANCE) ± <br />35000SF <br />(N) EQUIPMENT PAD, TYP., MIN SLOPE 1% IN ALL <br />DIRECTIONS, MAX SLOPE 2% IN ALL DIRECTIONS <br />(E) PROPERTY LINE <br />(N) CONCRETE CURB AND GUTTER, <br /> PER ARCHITECTURAL <br />(N) PRE-ASSEMBLED UNIT, TO BE <br />FLUSHED WITH SURROUNDING <br />GRADE (TYP. 4) <br />(N) EQUIPMENT PAD, TO BE FLUSHED WITH <br />SURROUNDING GRADE TYP. <br />FUTURE PV CANOPY <br />COLUMN TYP. <br />FUTURE PRE-ASSEMBLED SUPERCHARGER UNIT, <br />TO BE FLUSHED WITH SURROUNDING GRADE TYP. <br />FUTRE PRE-ASSEMBLED <br />SUPERCHARGER UNIT, <br />MIN CROSS-SLOPE 1%, <br />MAX CROSS-SLOPE 2%, <br />MAX LONGITUDINAL SLOPE 5% <br />TEMPORARY EDGE OF ASPHALT. EXTEND <br />BASE ROCK MIN. 2' BEYOND EDGE OF <br />PAVEMENT. <br />FUTURE PV CANOPY OUTLINE TYP. <br />(N) PV CANOPY OUTLINE <br />(N) PV CANOPY <br />COLUMN, TYP1.02%1.00%1.14%0.94%1.29%1.41%89.68'13.07 FG <br />13.76 FG <br />14.67 FG <br />14.63 FG <br />14.55 FG <br />14.55 FG <br />14.55 FG 14.55 FG <br />14.56 FG 14.56 FG14.45 FG14.51 FG <br />14.55 FG <br />14.58 FG <br />14.55 FG <br />14.58 FG <br />14.63 FG <br />14.66 FG <br />14.66 FG 14.58 FG 14.58 FG <br />14.55 FG <br />14.35 FG <br />14.32 FG <br />14.55 FG <br />13.79 FG <br />13.90 FG <br />13.79 FG <br />13.90 FG <br />12.56 FG <br />12.67 FG <br />12.67 FG <br />12.56 FG <br />1313 <br />12 <br />11 <br />14 <br />14 <br />14 <br />13.49 FG 13.30 FG <br />13.21 FG <br />13.64 FG <br />13.90 FG <br />14.12 FG 14.02 FG <br />13.53 FG <br />13.45 FG <br />13.38 FG <br />13.76 FG <br />13.45 FG <br />13.48 FG <br />13.61 FG <br />FUTURE CURB TO BE FLUSHED WITH SURROUNDING GRADE <br />(N) RIP RAP5.00'5.00'(N) GRSSY FILTER STRIP, REF C-502 <br />(N) RAIN GARDEN, REF C-502 <br />200.00'EXCESS RUNOFF WILL OUTFLOW FROM THIS POINT TO <br />EXISTING INFRASTRUCTURE <br />(E) CURB AND GUTTER <br />1211.92 FG 12.11 FG11.92 FG <br />10.97 FG10.97 FG <br />10.82 FG <br />10.82 FG <br />12.56 FG <br />12.56 FG <br />9.82 BP <br />9.82 BP <br />9.92 BP <br />9.82 BP <br />1.62%1.73%1.73%1.29%1.48%1.42%1.00%1.29%1.00%1.16%1.20%1.20%4.03%1.37% <br />12.11 FG <br />13(13.11) EG (13.12) EG <br />(11.76) EG <br />GRADING PLAN <br />1" = 20'-0" <br />0 20'40'10'5' <br />SITE LEGEND <br />(N) FIXED BOLLARD <br />(N) CONCRETE CURB <br />(N) REBOUNDING BOLLARD <br />SIGN <br />(N) FULL DEPTH ASPHALT <br />(N) REMOVABLE BOLLARD <br />(N) REBOUNDING BOLLARD <br />(N) UTILITY BOLLARD <br />(N) CRADLE POINT <br />REPEATER, REF. <br />SINGLE LINE DIAGRAM <br />(N) POLE-MOUNTED LIGHT <br />FIXTURE <br />(E) ELEVATION <br />(E) BACK OF CURB <br />ELEVATION <br />(E) TOP OF CURB <br />ELEVATION <br />(N) FINISHED GRADE <br />ELEVATION <br />(N) BACK OF CURB <br />ELEVATION <br />(N) TOP OF CURB <br />ELEVATION <br />(E) MAJOR CONTOUR LINE <br />(E) MINOR CONTOUR LINE <br />XX <br />xx <br />xx <br />XX <br />(N) MAJOR CONTOUR LINE <br />(N) MINOR CONTOUR LINE <br />(N) ADA PARKING AREA <br />(XX.XX) <br />(XX.XX)BC <br />(XX.XX)TC <br />XX.XX FG <br />XX.XX BC <br />XX.XX TC <br />X.X%SURFACE SLOPE (%) <br />PROPERTY LINE <br />(N) SUPERCHARGER POST <br />(E) FLOW LINE ELEVATION(XX.XX)FL <br />(N) BOTTOM OF PIT <br />ELEVATIONXX.XX BP <br />N <br />S <br />EW <br />(N) TOP OF FOUNDATION <br />ELEVATION <br />XX.XX TF <br />(N) CONCRETE PAVING <br />1"12"0 <br />PROPRIETARY AND CONFIDENTIAL <br />ABCDEFGH <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />DATENO.REVISIONORIGINAL SIZE 24"X36" <br />SHEET SIZE ARCH "D" <br />3500 DEER CREEK RD. <br />PALO ALTO, CA 94304 <br />(650) 681-5000 <br />3/27/2024AARCH SITE PLAN COMMENTS10/3/2024BAHJ COMMENTS, LAYOUT UPDATE14700 THORNTON RDLODI, CA 95242, USGRADING <br />PLAN <br />C-101 <br />REV: B IFP <br />IFAVEROTORRESPLOT DATE: 11/5/2024 1:47 PM <br />JB-9528024 <br /> TESLA SUPERCHARGER_LODI, CAPHASE 1: 16 SUPERCHARGERSIMPORTANT NOTE <br />ALL EXISTING AND PROPOSED <br />LOCATIONS ARE BASED OFF THE <br />SURVEYOR'S ESTABLISHED <br />BENCHMARK AND CONTROL <br />EARTHWORK VOLUME <br />Total Cut: 866 CuYd <br />Total Fill: 1026 CuYd <br />Net: 160 CuYd Fill <br />B <br />11/05/2024
The URL can be used to link to this page
Your browser does not support the video tag.