Laserfiche WebLink
Printed on:Friday 02/14/2025 11:47 AM 29C0038/AAAY/148028Pageof9 <br />Department of Transportation - Division of Maintenance Structure Maintenance & Investigations <br />10 <br />UpstreamSide 11/08/2024X-Section Date <br />Top of Right GirderMeasured From <br /> 3.20 <br /> 4.55 <br /> 8.40 <br /> 9.00 <br /> 8.20 <br /> 5.45 <br /> 4.90 <br /> 3.35 <br /> 2.50 <br /> 0.87 <br />Vert(m) <br />Face of Seat <br />Change in slope <br />Edge of Water <br />Thalweg <br />Edge of Water <br />Change in Slope <br />Face of Seat <br />The measurements below are measured <br />from the top of the RC slab on the right <br />Face <br />Abutment 1 <br />Pier 2 <br />Bent 3 <br />Bent 4 <br />Abutment 5 <br />Location <br />CHANNEL X-SECTION <br />CommentsHoriz(m) <br /> 0.00 <br /> 4.00 <br /> 10.20 <br /> 14.60 <br /> 19.50 <br /> 26.40 <br /> 27.90 <br /> 32.90 <br /> 37.80 <br /> 41.00 <br />220 <br />227 <br />228 <br />234 <br />256 <br />Pile Cap/Footing-RC <br />Pile-RC <br />Pile-Timber <br />Pier Cap-RC <br />Slope Protection <br />2 <br />2 <br />2 <br />2 <br />2 <br />1 <br />1 <br />1 <br />16 <br />2 <br />m <br />ea. <br />ea. <br />m <br />ea. <br /> 1 <br /> 1 <br /> 1 <br /> 16 <br /> 2 <br /> 0 <br /> 0 <br /> 0 <br /> 0 <br /> 0 <br /> 0 <br /> 0 <br /> 0 <br /> 0 <br /> 0 <br />SUBSTRUCTURE ELEMENT INSPECTION RATINGS AND NOTES <br /> 0 <br /> 0 <br /> 0 <br /> 0 <br /> 0 <br />SUBSTRUCTURE <br />SUBSTRUCTURE RATING =(60)7 <br />(215) Abutment-RC <br />(220) Pile Cap/Footing-RC <br />(227) Pile-RC <br />(228) Pile-Timber <br />(234) Pier Cap-RC <br />(256) Slope Protection <br />Element DescriptionElem <br />No. <br />Env Total <br />Qty <br />Units <br />CS 1 CS 2 CS 3 CS 4 <br />Qty in each Condition StateDefect/ <br />Prot Defect <br />There were no significant defects noted. <br />The Span 1 side of Pier 2 footing is exposed horizontally up 4 feet and vertically up to 8 inches on the left side. This condition is not <br />caused by stream action and therefore does not warrant a defect at this time. (See Photo 10 dated 11/09/2022). This condition has <br />been previously reported and no significant changes were noted. <br />The pile element is included to indicate the presence of piles on this structure. The piles were not exposed for visual inspection. No <br />indication of pile distress was noted in any substructure element. <br />The pile element is included to indicate the presence of piles on this structure. The piles were not exposed for visual inspection. No <br />indication of pile distress was noted in any substructure element. <br />There were no significant defects noted. <br />There were no significant defects noted.