Laserfiche WebLink
Printed on:Tuesday 05/30/2023 08:30 AM 29C0048/AAAO/102092Pageof66 <br />Department of Transportation - Division of Maintenance Structure Maintenance & Investigations <br />OTHER WORK RECOMMENDATIONS - NONE <br />JOINT/APPR/RAIL WORK RECOMMENDATIONS <br />SUPERSTRUCTURE WORK RECOMMENDATIONS - NONE <br />SUBSTRUCTURE WORK RECOMMENDATIONS - NONE <br />Work By <br />Action <br />Est CostRec Date LOCAL AGENCY <br />Appr. Roadway-Repair <br />01/12/2015 <br />Str Target ROUTINE <br />Repair the AC approach roadway at both abutments. <br />Dist Target <br />EA Status PROPOSED <br />Photo 1 <br />Map View <br />OTHER PHOTOGRAPHS <br />DECK WORK RECOMMENDATIONS <br />Work By <br />Action <br />Est Cost Rec Date LOCAL AGENCY <br />Deck-Patch spalls <br />01/10/2019 <br />Str Target ROUTINE <br />Repair the delaminated areas of the polyester concrete overlay in the northbound lanes. <br />Dist Target <br />EA Status PROPOSED <br />234 Pier Cap-RC 2 70 m 70 0 0 <br />SUBSTRUCTURE ELEMENT INSPECTION RATINGS AND NOTES <br /> 0 <br />SUBSTRUCTURE <br />SUBSTRUCTURE RATING =(60)7 <br />WORK RECOMMENDATIONS <br />(227) Pile-RC <br />(234) Pier Cap-RC <br />Element DescriptionElem <br />No. <br />Env Total <br />Qty <br />Units <br />CS 1 CS 2 CS 3 CS 4 <br />Qty in each Condition StateDefect/ <br />Prot Defect <br />5 piles from the 1971 structure are exposed at Bent 4. The 4 right piles on the right portion of the structure and the interior pile on the <br />left portion of the structure are exposed as follows: <br />Pile 4: 16 inches <br />Pile 10: 6 inches <br />Pile 11: 6 inches <br />Pile 12: 12 inches <br />Pile 13: 7 inches <br />There were no significant defects noted.